• 제목/요약/키워드: chemical cartridge

검색결과 72건 처리시간 0.031초

UPLC를 활용한 데리스 추출물 함유 유기농자재 중 Rotenone과 Deguelin 정량분석 (Quantitative Analysis of Rotenone and Deguelin in Biopesticides Containing Derris Extract by Ultra performance Liquid Chromatography)

  • 임성진;김진효;최근형;박병준
    • 한국환경농학회지
    • /
    • 제34권1호
    • /
    • pp.52-56
    • /
    • 2015
  • BACKGROUND: Three commercial biopesticides containing derris extract, which is permitted as a commercial biopesticide substances by the Environmentally-friendly Agriculture Promotion Act, have been marketed in Korea. But, the quantitative analytical method of active substances for crop protection in biopesticides containing derris extract has not known. METHODS AND RESULTS: Solid phase extraction (SPE) cartridge clean-up method for the quantitative analysis of rotenone and deguelin in biopesticides containing derris extract was developed and validated by ultra-performance liquid chromatography (UPLC). The clean-up method was established using hydrophilic lipophilic balance (HLB) SPE cartridges for the bioactive substances in biopesticides containing derris extract, and the eluate was analyzed to quantify the rotenone and deguelin by the UPLC. LOQ and recovery rates of rotenone and deguelin were 0.085 and 0.044 mg/L, 95.7 and 93.3%, respectively. The content of rotenone and deguelin in three biopesticides containing derris extract were analyzed by the developed method, the results showed 0.001-0.236 and

Development and Validation of an Analytical Method for Tridemorph Determination in Tea Samples by Liquid Chromatograph-Electrospray Ionization-Tandem Mass Spectrometry

  • Do, Jung-Ah;Park, Hyejin;Kwon, Ji-Eun;Cho, Yoon-Jae;Chang, Moon-Ik;Oh, Jae-Ho;Hwang, In-Gyun
    • 한국식품위생안전성학회지
    • /
    • 제29권4호
    • /
    • pp.292-298
    • /
    • 2014
  • 차 중에 있는 살균제 tridemorph의 잔류량을 검사하기 위해 LC-ESI-MS/MS를 이용한 정확하고 감도가 좋은 분석방법을 개발하였다. Tridemorph 잔류물은 샘플을 수화한 후 acetonitrile로 추출하고, NaCl을 이용한 액-액 분배, $NH_2$ 카트리지 정제를 거쳐 기기분석을 수행하였다. 직선성은 $0.02{\sim}1.0{\mu}gmL^{-1}$ 범위에서 상관계수($r^2$) 0.9999로 높은 직선성을 보였다. 0.02와 $0.05mgkg^{-1}$ 처리수준으로 회수율을 실험한 결과는 75.0~84.7% 이었으며, 상대표준편차는 10% 미만이었다. 분석방법의 검출한계와 정량한계는 각각 0.01와 $0.02mgL^{-1}$ 이었다. 이러한 결과들을 통해 확립된 분석법은 차 중 tridemorph의 잔류량 분석에 적합함을 확인할 수 있었다.

Development and Interlaboratory Validation of an Analytical Method for the Determination of Saflufenacil in Agricultural Products by HPLC-UVD and LC-MS

  • Do, Jung-Ah;Park, Hyejin;Kwon, Ji-Eun;Oh, Jae-Ho;Cho, Yoon-Jae;Chang, Moon-Ik;Choi, Won-Jo;Lee, Hyun-Sook;Hong, Jin-Hwan
    • 한국식품위생안전성학회지
    • /
    • 제29권4호
    • /
    • pp.285-291
    • /
    • 2014
  • 농산물 중에 있는 제초제 saflufenacil의 잔류량을 검사하기 위해 HPLC-UVD와 LC-MS를 이용한 정확하고 감도가 좋은 분석방법을 개발하였다. Saflufenacil 잔류물은 acetone 추출, dichloromethane을 이용한 액-액 분배, silica와 carbon 카트리지 정제를 거쳐 기기분석을 수행하였다. 검량선 작성을 위해 $0.1{\sim}5.0{\mu}gmL^{-1}$ 범위로 표준품을 만들어 실험한 결과 상관계수($r^2$)는 0.999로 높은 직선성을 보였다. $0.02{\sim}0.5mgkg^{-1}$ 처리수준으로 회수율을 실험한 결과는 80.5~110.2% 이었으며, 상대표준편차는 10% 미만이었다. 분석방법의 검출한계와 정량한계는 각각 0.005와 $0.02mgL^{-1}$ 이었다. 확립된 시험법으로 본청, 부산지방식품의 약품안전청과 경인지방식품의약품안전청에서 실험실간 검증을 실시한 결과 만족스런 결과를 얻었다. 이러한 결과들을 통해 확립된 시험법은 농산물 중 saflufenacil의 잔류량 분석에 적합함을 확인할 수 있었다.

Characterization of depth filter media for gas turbine intake air cleaning

  • Park, Young Ok;Hasolli, Naim;Choi, Ho Kyung;Rhee, Young Woo
    • 한국입자에어로졸학회지
    • /
    • 제5권4호
    • /
    • pp.159-170
    • /
    • 2009
  • A depth filter medium was newly designed in order to achieve high collection of dust and low pressure drop in this work. Multilayer depth filter media consist of an upstream layer of highly porous structure which allows particles to pass through and to follow by one or more downstream layers to hold the particles inside the media. For each filter media, flat sheet and pleated module were made of newly developed depth filter media and filter media of commercial products. Commercial depth filter cartridge for gas turbine air intake cleaning were used as reference for filtration area and pleat geometry of pleated modules. This work attempts to evaluate and compare the newly developed depth filter medium and two commercial filter media in terms of filtration parameters such as air permeability, initial pressure drop, particle retention and pressure drop variation with dust loading. According to the close examination the newly developed depth filter showed better performance compared to the commercial depth filter media.

  • PDF

바이오 응용을 위한 공압 디스펜싱 시스템의 반복 정밀도 연구 (Repeatability Study of a Pneumatic Dispensing System for Bio-Applications)

  • 이상민;최인호;김준원
    • 센서학회지
    • /
    • 제21권1호
    • /
    • pp.53-58
    • /
    • 2012
  • Biological and chemical assays(e.g., clinical tests for medical diagnosis) are needed to handle small liquid volume with high accuracy and high reliability. Many micro-dispensing systems using various actuation methods have been developed and applied. In this research, we confirm repeatability of the cartridge-type dispensing system with various measuring methods for guarantee of an acceptable reliability. We systematically examine the dispensed volume variation and dispense rate during 500,000 shots of sequential actuation. Using the same method, we confirm the repeatability of dispensed volume while varying operating conditions and design parameter(i.e., outlet size) of the dispensing system. Also, we examine the consistency of the dispensed volume of droplet while varying the operating pressures. Furthermore, we repeatedly measure differences between an actual dispensed volume and a target volume. According to our results, it is expected that the stable and reliable performance of our dispensing system can effectively be used in various applications containing bio-solutions.

Method for Evaluating Metabolic Functions of Drugs in Bioartificial Liver

  • Park, Yueng-Guen;Hiroo Iwata;Seiji Satoh;Takehiko Uesugi;Ryu, Hwa-Won
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제8권5호
    • /
    • pp.279-285
    • /
    • 2003
  • Lidocaine and galactose loading tests were performed on a bioartificial liver (BAL), an extracorporeal medical device incorporating living hepatocytes in a cartridge without a transport barrier across the membranes. The concentration changes were analyzed using pharmacokinetic equations to evaluate the efficacy and limitation of the proposed method. Lidocaine and galactose were found to be suitable drugs for a quantitative evaluation of the BAL functions, as they did not interact with the plasma proteins or blood vessels, making their concentrations easy to determine. The drug concentration changes after drug loading were easily analyzed using pharmacokinetic equations, and the BAL functions quantitatively expressed by pharmacokinetic parameters, such as the clearance (CL) and galactose elimination capacity (GEC). In addition, these two drugs have already been used in clinical tests to evaluate human liver functions over long periods, and lidocaine CL values and GEC values reported for a normal human liver. Thus, a comparison of the CL and GEC values for the BAL and a natural liver revealed what proportion of normal liver functions could be replaced by the BAL.

Development and Validation of Analytical Methods for Picoxystrobin Determination in Agricultural Products by GC-ECD and GC-MS

  • Do, Jung-Ah;Lee, Min-Hye;Park, Hyejin;Kang, Il-Hyun;Kwon, Kisung;Oh, Jae-Ho
    • 한국식품위생안전성학회지
    • /
    • 제27권4호
    • /
    • pp.332-338
    • /
    • 2012
  • 농산물 중에 있는 Picoxystrobin 잔류량을 검사하기 위해 가스크로마토그래프-전자포획검출기와 가스크로마토그래프-질량분석기를 이용한 간단하고 감도가 좋은 분석방법을 개발하였다. Picoxystrobin 잔류물은 acetonitrile 추출, 포화식염수를 이용한 액-액 분배, florisil 카트리지 정제 과정을 거쳐 기기분석을 수행하였다. 개발된 방법으로 Picoxystrobin 잔류허용기준이 설정된 식품인 고추와 사과 외 대표 농산물 시료 현미, 대두, 버섯, 감귤을 대상으로 농약을 0.02, 0.05, 0.5 mg/kg 농도로 처리하여 회수율을 시험한 결과는 64.0~98.3%이었으며, 상대표준편차는 10% 미만이었다. 검량선 작성을 위해 0.1~5 mg/L 범위로 표준품을 만들어 실험한 결과 상관계수($r^2$)는 0.999로 높은 직선성을 보였으며, 분석방법의 검출한계와 정량한계는 각각 0.005와 0.02 mg/kg이었다. 또한 확인시험을 위하여 질량분석기를 사용하였으며, 145와 335를 특성이온으로 선정하였다.

노후 분말소화기의 폭발사고 원인과 예방대책에 관한 분석 (Analysis of the Precautionary Measures and Causes on Explosion Accidents of a Old Dry Chemical Powder Extinguisher)

  • 이의평
    • 한국화재소방학회논문지
    • /
    • 제26권3호
    • /
    • pp.91-99
    • /
    • 2012
  • 분말소화기를 조작하거나 해체하는 과정 중에 아주 드물게 사상자가 발생하는 경우가 있다. 부식된 분말소화기는 조작 중 또는 해체(폐기)과정 중에 폭발하면 로켓과 같이 위쪽으로 솟아오르면서 소화기 조작자나 해체과정 중인 사람의 머리나 가슴, 목 부위 등을 쳐서 사상사고를 발생하게 한다. 이 논문에서는 분말소화기파열사고사례를 알아본 후, 파열사고의 원인과 파열로 인한 반동력, 예방대책에 대해 알아보았다. 소화기 파열사고의 예방대책으로 훈련이나 교육에 부식된 소화기의 사용 자제, 부식된 소화기에 대한 위험성 교육 및 홍보, 기설치 가압식분말소화기에 파열위험성 표시, 내용연수 표시 의무화, 일정기간 경과 소화기에 대한 수압검사 제도의 도입 검토, 폐소화기 회수시스템 구축, 폐소화기의 재활용시스템 구축, 노후소화기관련 상담창구 운영 등을 제안하였다.

열 장 흐름 분획장치의 제작과 효율성에 관한 연구 (A Study of Construction and Efficacy of Thermal Field-Flow Fractionation)

  • 이대운;허욱환;전선주;이인호
    • 대한화학회지
    • /
    • 제36권3호
    • /
    • pp.419-427
    • /
    • 1992
  • 본 연구에서는 열 장 흐름 분획장치를 제작하고 이를 이용하여 폴리스티렌의 머무름과 선택성을 조사하였으며 최적 분리조건을 결정하였다. 열 장 흐름 분획장치의 채널 부분은 열전도도가 좋은 구리판을 윗벽과 아랫벽으로 하여 그 사이에 Mylar spacer를 끼워 제작하였다. 구리판 표면은 이상적인 유선형 흐름이 이루어지도록 매끈하고 굴곡이 없도록 세공하였으며, Mylar spacer는 채널을 형성하도록 잘라낸 후 거친 부분을 사포로 갈아내었다. 윗 구리판은 히터를 넣어 온도를 높였고 아래 구리판은 수도물을 이용하여 온도를 낮추어 온도 구배를 주었다. 폴리스티렌의 머무름은 분자량과 채널에 가해준 온도차가 커지면 증가하였고, 일정한 온도차에서 차가운 벽의 온도를 20∼$45^{\circ}C$로 높히면 감소하였다. 시료의 선택성은 크기 배제 크로마토그래피보다 훨씬 좋았으며, 머무름이 큰 용질일수록 선택성이 좋았다. 이론단의 높이는 유속과 비례하였으며, 이로부터 폴리스티렌의 다분산도를 측정할 수 있었다.

  • PDF

LC/ESI-MS/MS를 이용한 식육(소, 돼지)중 잔류 phoxim 분석 (Analysis of Phoxim Residue in Animal Food Production (Cattle and Pig) by LC/ESI-MS/MS)

  • 박미선;이진주;명승운
    • 대한화학회지
    • /
    • 제55권4호
    • /
    • pp.626-632
    • /
    • 2011
  • 폭심(phoxim)은 널리 사용되고 있는 구충제인 동물용의약품이다. 본 논문에서는 소와 돼지 근육에 잔류하는 폭심을 분석하기 위해서, 실리카 고체상과 아세토니트릴을 사용하여 추출/정제하였다. 분석을 위해서 LC/ESI-MS/MS 방법이 사용되었다. HPLC에서 $C_{18}$ 컬럼($2.1{\times}100\;mm$, $3.5\;{\mu}m$)이 사용되었으며, 이동상으로는 0.1% formic acid와 물이 사용되었다. 소(0.0048~2.0 mg/kg)와 돼지(0.0055~2.0 mg/kg)에 소량첨가하여 얻은 검정곡선은 좋은 직선성($r^2$=0.995)을 나타내었다. 소와 돼지의 매트릭스에 대해서 0.0048~0.2 mg/kg범위에서 68.2~106.9%의 정확도를 나타내었으며, LOD는 0.0014~0.0017 mg/kg, LOQ는 0.0048~0.0055 mg/kg범위에 있었으며, 11.2%의 상대표준편차를 나타내었다.