• 제목/요약/키워드: charging-discharging

검색결과 466건 처리시간 0.026초

ESS 배터리 충방전 시스템을 위한 8kW급 LLC 절연형 컨버터 설계 (8kW LLC Isolated Converter Design for ESS Battery Charge/Discharge System)

  • 김진우;백승훈;조영훈;구태근
    • 전력전자학회논문지
    • /
    • 제23권3호
    • /
    • pp.161-167
    • /
    • 2018
  • In battery-operated systems, an isolated converter is used to interface the utility grid with the system to increase stability when charging and discharging batteries. Systems such as vehicle-to-grids (V2Gs), on-board chargers, and energy storage systems (ESSs) have recently become popular, and the roles of isolated converters have become important considerations in fabricating such devices. A fixed-frequency LLC converter, which is a type of isolated converter, presents the advantages of high efficiency and high power density by performing zero-voltage switching (ZVS) over wide frequency ranges. However, the magnetizing inductance of the LLC converter should be designed to enable ZVS in all switching devices. Therefore, in this study, the operating characteristics of the LLC circuit are analyzed, and an optimal design method for ZVS operation is established. Moreover, an 8 kW LLC high-efficiency and high-power-density resonant converter is designed and tested for ESS application. The LLC converter achieves 98% efficiency at rated power.

진공 스위치를 이용한 Crowbar 시스템의 개발 (Development of the Crowbar System Using a Vacuum Switch)

  • 이태호;허창수;이홍식
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권12호
    • /
    • pp.584-590
    • /
    • 2002
  • Crowbar system is usually applied to a pulsed power system in which a capacitor bank is discharged into a load. This provides a free wheeling path for the load current and prevents the capacitor from recharging due to a reverse voltage. Usually diodes have been used as a crowbar switch, but it is not a practical system because the cost of the diodes goes up enormously with increasing the system voltage and current. This paper presents a novel protection scheme of a charging and discharging system of a 300 kJ capacitor bank using a low-cost crowbar system which consists of a crowbar switch and resistors. Triggered vacuum switch(TVS) was used for a crowbar switch, and Rogowski coil was used to determine a trigger time of TVS. When this crowbar system is applied to our pulsed power system which consists of capacitor bank($123muF$), inductor() for forming a pulse, load resistor$(100 m\Omega)$, and a closing switch, instantaneous reversal voltage of capacitor bank could be limited less than 1.8 ㎸ until capacitor bank was charred to 17 ㎸.

자전연소합성법을 이용한 리튬이차전지용 양극활물질 LiCoO2의 제조 및 특성 (Synthesis and Characteristics of LiCoO2 Powders Prepared by SHS Process)

  • 류명한;이종현;원창환
    • 한국세라믹학회지
    • /
    • 제41권5호
    • /
    • pp.388-394
    • /
    • 2004
  • 균일하게 혼합된 LiNO$_3$와 Co 금속분말을 알곤 분위기 하에서 SHS 공정으로 리튬이차전지용 양극활물질인 LiCoO$_2$분말을 합성하였다. 여러 가지 반응변수에 따라 제조된 분말의 특성과 전기화학적 특성평가를 수행하였는데, 반응온도 및 속도와 제조된 분말의 입도는 각각 Li/Co 몰비와 시료의 냉각속도 변화로 제어 가능하였다. Li/Co 몰비가 1.05일 때 최대방전용량인 145 mAh/g을 나타냈으며, 10회 충ㆍ방전 실험 후 6.4%의 낮은 용량감소를 갖는 비교적 안정된 cycling 특성을 보였다.

FPGA를 이용한 압전소자 작동기용 단일칩 제어기 설계 (Single-Chip Controller Design for Piezoelectric Actuators using FPGA)

  • 윤민호;박정근;강태삼
    • 제어로봇시스템학회논문지
    • /
    • 제22권7호
    • /
    • pp.513-518
    • /
    • 2016
  • The piezoelectric actuating device is known for its large power density and simple structure. It can generate a larger force than a conventional actuator and has also wide bandwidth with fast response in a compact size. To control the piezoelectric actuator, we need an analog signal conditioning circuit as well as digital microcontrollers. Conventional microcontrollers are not equipped with an analog part and need digital-to-analog converters, which makes the system bulky compared with the small size of piezoelectric devices. To overcome these weaknesses, we are developing a single-chip controller that can handle analog and digital signals simultaneously using mixed-signal FPGA technology. This gives more flexibility than traditional fixed-function microcontrollers, and the control speed can be increased greatly due to the parallel processing characteristics of the FPGA. In this paper, we developed a floating-point multiplier, PWM generator, 80-kHz power control loop, and 1-kHz position feedback control loop using a single mixed-signal FPGA. It takes only 50 ns for single floating-point multiplication. The PWM generator gives two outputs to control the charging and discharging of the high-voltage output capacitor. Through experimentation and simulation, it is demonstrated that the designed control loops work properly in a real environment.

연료전지용 커패시터 충.방전을 위한 양방향 DC-DC 컨버터 제어기 설계 (The Controller Design of Bi-directional DC-DC Converter for a Fuel Cell Energy Storage System)

  • 김승민;양승대;최주엽;안진웅;이상철;이동하
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.222-228
    • /
    • 2012
  • This paper presents a design and simulation of bi-directional DC/DC boost converter for a fuel cell system. In this paper, we analyze the equivalent model of both a boost converter and a buck converter. Also we propose the controller of bi-directional DC-DC converter, which has buck mode of charging a capacitor and boost mode of discharging a capacitor. In order to design a controller, we draw bode plots of the control-to-output transfer function using specific parameters and incorporate 3pole-2zero compensator in a closed loop. As a result, it has increased PM(Phase Margin) for better dynamic performance. The proposed bi-directional DC-DC converter's 3pole-2zero compensation method has been verified with computer simulation and simulation results obtained demonstrates the validity of the proposed control scheme.

  • PDF

Building Smart Microgrid Test-Bed를 이용한 전력사용량 패턴 최적화방안 연구 (A Study on the Optimization of Power Consumption Pattern using Building Smart Microgrid Test-Bed)

  • 이상우;강진규;이동하
    • 한국태양에너지학회 논문집
    • /
    • 제34권4호
    • /
    • pp.1-7
    • /
    • 2014
  • The microgrid system is the combination of photovoltaic(PV) array, load, and battery energy storage system. The control strategies were defined as multi-modes of operation, including rest operation without use of battery, power charging, and power discharging, which enables grid connected mode or islanded mode. Photovoltaic power is a problem of the uniformity of power quality because the power generated from solar light is very sensitive to variation of insolation and duration of sunshine. As a solution to the above problem, energy storage system(ESS) is considered generally. There fore, in this study, we did basic research activities about optimization method of the amount of energy used, using a smart microgrid test-bed constructed in building. First, we analyzed the daily, monthly and period energy pattern amount of power energy used, and analyzed PV power generation level which is built on the roof. Utilizing building energy pattern analysis data, we was studied an efficient method of employing the ESS about building power consumption pattern and PV generation.

Parallel Load Techinques Application for Transcranial Magnetic Stimulation

  • Choi, Sun-Seob;Kim, Whi-Young
    • Journal of Magnetics
    • /
    • 제17권1호
    • /
    • pp.27-32
    • /
    • 2012
  • Transcranial magnetic stimulation requires an electric field composed of dozens of V/m to achieve stimulation. The stimulation system is composed of a stimulation coil to form the electric field by charging and discharging a capacitor in order to save energy, thus requiring high-pressure kV. In particular, it is charged and discharged in capacitor to discharge through stimulation coil within a short period of time (hundreds of seconds) to generate current of numerous kA. A pulse-type magnetic field is formed, and eddy currents within the human body are triggered to achieve stimulation. Numerous pulse forms must be generated to initiate eddy currents for stimulating nerves. This study achieved high internal pressure, a high number of repetitions, and rapid switching of elements, and it implemented numerous control techniques via introduction of the half-bridge parallel load method. In addition it applied a quick, accurate, high-efficiency charge/discharge method for transcranial magnetic stimulation to substitute an inexpensive, readily available, commercial frequency condenser for a previously used, expensive, high-frequency condenser. Furthermore, the pulse repetition rate was altered to control energy density, and grafts compact, one-chip processor with simulation to stably control circuit motion and conduct research on motion and output characteristics.

수용성 전해질을 이용한 이산화망간 2차 전지에 대한 고찰 (Survey on rechargeable battery of MnO2-Zn using aqueous solution)

  • 박석준;신희성;김영철;오창섭
    • 에너지공학
    • /
    • 제25권4호
    • /
    • pp.245-250
    • /
    • 2016
  • 이산화망간은 전지의 활성물질로서 우수한 특성을 가지고 있고 가격도 저렴한 재료로서 각종 1차전지에 사용되어왔다. 그러나 이산화망간을 이용한 2차 전지에 대한 연구는 그렇게 많지 않다. 최근 이산화망간의 충전가역성에 관하여 황산아연을 전해질로 하는 이산화망간 아연전지가 재충전이 가능하다는 보고가 있다. 여기서는 이산화망간이 황산아연수용액 중에서 가역적으로 충전방전이 가능한 것을 토대로 2차전지로서의 가능성에 대해 서술한다.

계통연계형 풍력, 태양광 및 축전지 하이브리드 시스템의 출력제어 및 동특성 해석 (Power Control and Dynamic Performance Analysis of a Grid-Interactive Wind/PV/BESS Hybrid System)

  • 김슬기;전진홍;조창희;안종보
    • 전기학회논문지
    • /
    • 제56권2호
    • /
    • pp.317-324
    • /
    • 2007
  • Most conventional hybrid systems using renewable energy sources have been applied for stand-alone operation, but Utility-interface may be an useful and viable option for hybrid systems. Grid-connected operation may have benefits such as reduced losses in power system distribution, utility support in demand side management, and peak load shaving. This paper addresses power control and dynamic performance of a grid-connected PV/wind/BESS hybrid system. At all times the PV way and the wind turbine are individually controlled to generate the maximum energy from given weather conditions. The battery energy storage system (BESS) charges or discharges the battery depending on energy gap between grid invertger generation and production from the PV and wind system. The BESS should be also controlled without too frequently repeated shifts in operation mode, charging or discharging. The grid inverter regulates the generated power injection into the grid. Different control schemes of the grid inverter are presented for different operation modes, which include normal operation, power dispatching, and power smoothing. Simulation results demonstrate that the effectiveness of the proposed power control schemes for the grid-interactive hybrid system.

SMES 와 DVR을 이용한 전력계통품질 안정화 시스템 모델링 (Modeling of Power Quality Stabilization using SMES and DVR)

  • 박성열;정희열;김아롱;김재호;박민원;유인근;김석호;김해종;성기철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.2251-2252
    • /
    • 2008
  • Recently, voltage sag from sudden increasing loads is also one of the major problems inside the utility network. In order to compensate the voltage sag problem, power compensation device systems could be a good solution method. In case of voltage sag, an energy source is needed to overcome the energy loss caused by the voltage sag. Superconducting Magnetic Energy Storage (SMES) is a very promising source of this energy due to its fast response of charging and discharging time. Before constructing the power electronic delivering system for the SMES, it is necessary to simulate the system to understand its behavior. Nowadays, a lot of devices have been developed to compensate voltage sag such as Dynamic Voltage Restorer (DVR), Distribution Static Compensator (D-STATCOM) and Uninterruptible Power Supply (UPS). In this paper, focus is given only on DVR system which will be simulated by using PSCAD/EMTDC software.

  • PDF