• Title/Summary/Keyword: charging factor

Search Result 128, Processing Time 0.021 seconds

Battery Charging System for PHEV and EV using Single Phase AC/DC PWM Buck Converter

  • Lee, Jung-Hyo;Jung, Doo-Yong;Park, Sang-Hoon;Lee, Taek-Kie;Kim, Young-Ryul;Won, Chung-Yuen
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.5
    • /
    • pp.736-744
    • /
    • 2012
  • In this paper, a battery charging system for Plug-in Hybrid Electric Vehicle (PHEV) and Electric Vehicle (EV), and operation algorithm of charging system are introduced. Also, the proposed charging system uses commercial electricity in order to charge the battery of parked PHEV and 48V battery charging system with power factor controllable single phase converter for PHEV is investigated in this paper. This research verifies the power factor control of input and the converter output controlled by the charge control algorithm through simulation and experiment.

An Empirical Study on Revenue Creation Factor in Internet Industry (인터넷산업의 유료화를 통한 수익 창출 요인에 관한 실증적 연구)

  • Lee Dong-Cheol;Kim Min-Cheol;Kang Gil-Bong
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.27 no.4
    • /
    • pp.105-109
    • /
    • 2004
  • The purpose of this paper is to examine the empirical analysis for charging factors and the evaluation models of internet site. Thus this is to analyze the revenue creation factors affecting the customer satisfaction of tourism information sites in the Internet. Based on the regression model applied to a customer survey, this study shows that among the characteristics of the site, technical factor and community factor have the most significant effect on charging factor and customer satisfaction.

A Study on the Development of the Charging-Discharging System with High Power Factor and High Efficiency (고역율, 고효율 충.방전기 개발에 관한 연구)

  • Kim, Eun-Soo;Joe, Kee-Yeon;Byun, Young-Bok
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.568-572
    • /
    • 1994
  • This paper presents equipment for charging and discharging with high power factor aid high efficiency. This equipment is consisted of $3{\phi}$SPWM AC/DC converter for improving input current waveform and input power factor, and bidirectional DC/DC converter for electric isolation in the DC link Part. Therefore, Input power factor and the total efficiency in the proposed system can be increased more than in the conventional phase-controlled thyristor Charging - Discharging System.

  • PDF

Charging-Discharging System with High Power Factor, High Efficiency (고역률, 고효율 충.방전기)

  • Kim, Eun-Soo;Joe, Kee-Yeon;Byun, Young-Bok;Koo, Heun-Hoi
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.371-375
    • /
    • 1995
  • This paper presents equipment for charging and discharging with high power factor and high efficiency. This equipment is consisted of $3{\phi}$ SPWM AC/DC converter for improving input current waveform and input power factor, and bidirectional DC/DC converter for electric isolation in the DC link Part. Therefore, Input power factor and the total efficiency in the proposed system can be increased more than in the conventional phase-controlled thyristor charging-discharging System.

  • PDF

Buck-Type Charging Method for Loss Reduction of Multi-Function Inverter (다기능 인버터의 손실저감을 위한 Buck-Type 충전기법)

  • Kim, Dong-Hee;Woo, Dong-Gyun;Lee, Byoung-Kuk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.8
    • /
    • pp.1523-1528
    • /
    • 2011
  • This paper proposes buck-type charging method using motor inductance, 3-phase inverter and bi-directional converter without an additional charger in plug-in hybrid electric vehicles. The proposed system has advantages over the conventional system such as high charging efficiency, high power factor, and low total harmonic distortion. The validity of each methods are verified by theoretical analysis and simulation.

Development of High Voltage and High Energy Density Capacitor for Pulsed Power Application (펄스파워용 고전압 고에너지밀도 커패시터 개발)

  • 이병윤;정진교;이우영;박경엽;이수휘;김영광
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.5
    • /
    • pp.203-210
    • /
    • 2003
  • This paper describes high voltage and high energy density capacitor developed for pulsed power applications. The rated voltage of the developed capacitor is DC 22 [kV], the capacitance is 206 [$\mu$F] and the energy density is about 0.7 [kJ/kg]. Polypropylene film and kraft paper were used as the dielectrics. The ratio of the thickness of each dielectric material which consists of the composite dielectric structure, stacking factor and the termination method were determined by the charging and discharging tests on model capacitors. In terms of energy density, the developed capacitor has higher energy density compared with the products of foreign leading companies. In addition, it has been proved that the life expectancy can be more over 2000 shots through the charging and discharging test. The voltage reversal factor was 20%. This capacitor can be used as numerous discharge applications such as military, medical, industrial fields.

Design of a Rechargeable Battery Wireless Charging System

  • Kim, Dae-Hyun;Yeo, Tae-Dong
    • Journal of electromagnetic engineering and science
    • /
    • v.16 no.4
    • /
    • pp.210-213
    • /
    • 2016
  • This paper presents a wireless power charging system for rechargeable batteries. Recently, misalignment between transmitting coil and receiving coils has been a significant factor to wireless power charging systems, which are prone to lateral and angular misalignment. Unfortunately, the batteries can be easily rolled because of the shape, and coils are often misaligned while charging devices, in practical situations. This paper presents the wireless power battery charging system. In order to solve the angular misalignment, two perpendicular coil having structure of 'plus (+)' shape was proposed. To validate the results, the proposed wireless power charging system was implemented at 6.78 MHz using loosely coupled resonant coils, and the system was verified as being robust to misalignment.

Robust and Unity Input Power Factor Control Scheme for Electric Vehicle Battery Charger (전기차 배터리 충전기용 강인한 단위 입력 역률 제어장치)

  • Nguyen, Cong-Long;Lee, Hong-Hee
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.2
    • /
    • pp.182-192
    • /
    • 2015
  • This study develops a digital control scheme with power factor correction for a front-end converter in an electric vehicle battery charger. The front-end converter acts as the boost-type switching-mode rectifier. The converter assumes the two roles of the battery charger, which include power factor control and robust charging performance. The proposed control scheme consists of a charging control algorithm and a grid current control algorithm. The scheme aims to obtain unity input power factor and robust performance. Based on the linear average model of the converter, a constant-current constant-voltage charging control algorithm that passes through only one proportional-integral controller and a current feed-forward path is proposed. In the current control algorithm, we utilized a second band pass filter, a single-phase phase-locked loop technique, and a duty-ratio feed-forward term to control the grid current to be in phase with the grid voltage and achieve pure sinusoidal waveform. Simulations and experiments were conducted to verify the effectiveness of the proposed control scheme, both simulations and experiments.

Small Punch Test of TRIP Steel Charged with Hydrogen under Different Electrolyte Condition (다른 전해질분위기에서 수소주입시킨 TRIP강의 SP시험)

  • Kim, Kwang-Sig;Yoo, Kwang-Hyun;Park, Jae-Woo;Kang, Kae-Myung
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.1
    • /
    • pp.64-70
    • /
    • 2015
  • In order to evaluate the degree of hydrogen embrittlement of TRIP steels charged with hydrogen according to varying the current density and the charging time under acid and alkaline electrolyte conditions were tested by small punch test. The results of SP test showed that the degree of hydrogen embrittlement at acid electrolyte condition was more effective factor compared to that of alkaline electrolyte condition. Therefore, all of the charging time and the charging current density were at the condition of acid electrolyte appeared as the main factor of the degree of hydrogen embrittlement in the condition of acid electrolyte. But, it was considered that the charging time compared to the charging current density at the condition of alkaline electrolyte was more effective factor to raise the degree of hydrogen embrittlement.

Zero Torque Control of Switched Reluctance Motor for Integral Charging (충전기 겸용 스위치드 릴럭턴스 전동기의 제로토크제어)

  • Rashidi, A.;Namazi, M.M;Saghaian, S.M.;Lee, D.H.;Ahn, J.W.
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.2
    • /
    • pp.328-338
    • /
    • 2017
  • In this paper, a zero torque control scheme adopting current sharing function (CSF) used in integrated Switched Reluctance Motor (SRM) drive with DC battery charger is proposed. The proposed control scheme is able to achieve the keeping position (KP), zero torque (ZT) and power factor correction (PFC) at the same time with a simple novel current sharing function algorithm. The proposed CSF makes the proper reference for each phase windings of SRM to satisfy the total charging current of the battery with zero torque output to hold still position with power factor correction, and the copper loss minimization during of battery charging is also achieved during this process. Based on these, CSFs can be used without any recalculation of the optimal current at every sampling time. In this proposed integrated battery charger system, the cost effective, volume and weight reduction and power enlargement is realized by function multiplexing of the motor winding and asymmetric SR converter. By using the phase winding as large inductors for charging process, and taking the asymmetric SR converter as an interleaved converter with boost mode operation, the EV can be charged effectively and successfully with minimum integral system. In this integral system, there is a position sliding mode controller used to overcome any uncertainty such as mutual inductance or DC offset current sensor. Power factor correction and voltage adaption are obtained with three-phase buck type converter (or current source rectifier) that is cascaded with conventional SRM, one for wide input and output voltage range. The practicability is validated by the simulation and experimental results by using a laboratory 3-hp SRM setup based on TI TMS320F28335 platform.