• 제목/요약/키워드: charging circuit

검색결과 284건 처리시간 0.022초

비접촉 충전을 위한 ZVS 다중공진 포워드 컨버터의 설계에 관한 연구 (A Study on the Design of ZVS Multi-Resonant Forward Converter for Non-contact Charging)

  • 김영길;김진우;박진홍;이종규;이성백
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2000년도 학술대회논문집
    • /
    • pp.70-76
    • /
    • 2000
  • In the charge system, a contact type-convenient-charging method is insufficient because of the contact failure around moist environment and troublesome question to put in and pull out. For the solution of this problem, an electromagnetically coupled non-contact charger for the rechargeable cell is proposed using ZVS multi-resonant forward converter with synchronous rectifier. In this paper coupling coefficient(k), leaking inductance, coupling inductance and resonant frequency are observed for the air gap. By using the observed value, this circuit is designed and implemented. This proposed circuit is simulated by the PSPICE and experimented. The stress of a main switch and the output power are measured.

  • PDF

고성능 무선충전 시스템 개발 (Developed high performance wireless charging system)

  • 조철희;진아비;장해용;김동희
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 전력전자학술대회
    • /
    • pp.368-369
    • /
    • 2018
  • In this paper, a wireless charging system for drones is developed. The system is consists of PFC(Power Factor Correction), Full-Bridge inverter, S-S(Series-Series) resonant circuit and Full-Bridge rectifier. The parameters of the S-S resonant circuit is designed and calculated. According to these parameters and the switching devices, the system model without PFC is setted up with thermal module devices in PSIM. When output voltage is setted to 50[V] and input voltage is changed from 100[V] to 380[V], The efficiency of the system model is measured by simulation.

  • PDF

형광등용 인버터 시스템의 고조파 저감에 관한 연구 (A study on reducing the harmonics in inverter system for fluorescent lamp)

  • 박찬근;김종윤;전내석;박정환;이성근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.1199-1201
    • /
    • 2000
  • This paper proposes a harmonics reducing circuit for fluorescent lamp inverters using hybrid type smoothing circuit with pumping and smoothing capacitors. A waveform of full-wave rectification used as a direct current power supply at fluorescent lamp inverters contains a lot of harmonic wave from inrush current which is generated near the maximum of input voltage with purse shape when voltage smoothing capacitor is charged. Therefore, in order to suppress inrush current which will result in harmonic wave. this paper proposes a method to control abrupt charging current by use of charging voltage at pumping capacitor. The suppression of harmonics generation at lamp current is confirmed through simulations.

  • PDF

전기자동차 무선 충전용 수신패드 식별코일의 형상 설계 및 운용 방안 (Receiving Pad Identification Coil for Wireless Charging of Electric Vehicle)

  • 심동현;조현우;허훈;이주아;손원진;이병국
    • 전력전자학회논문지
    • /
    • 제27권6호
    • /
    • pp.455-463
    • /
    • 2022
  • This study proposes a receiving pad identification coil for wireless charging of electric vehicles. The proposed coil identifies the shape of the receiving pad through magnetic coupling with the receiving pad. Therefore, the shape of the coil is designed to show the different magnetic properties of each receiving pad. The accuracy of this design is verified through finite element method simulation. Furthermore, the operation method of the secondary pad identification circuit is described, and the appropriate magnitude and length of the pulse voltage applied to this circuit for receiving pad identification are derived through simulation. The performance of the proposed identification coil set is verified by the experimental results.

CDI시스템의 출력발생향상을 위한 실험적 연구 (Experimental Research to Improve the Output Characteristic of CDI System)

  • 전병실;김종규
    • 대한전기학회논문지
    • /
    • 제31권11호
    • /
    • pp.146-154
    • /
    • 1982
  • This paper proposes a new circuit for the CDI system to have a constant ignition power at the engine speed range of 500 to 7500 rpm and the battery voltage range of 12 to 16 volts in the 4-cylinder automobile. The proposed CDI system has a closed-loop with a PWM DC-DC converter controlled by the error signal between capacitor voltage and reference voltage. In order to decrease the capacitor charging time, the primary winding of ignition coil is made to be shorted during capacitor charging. An experimental suystem is fabricated and the results obtained thereof are found to be satisfactory.

전자혈압강하기의 전기적 특성 분석 (An Electrical Characteristics Analysis of Electronic Blood Pressure Depressor)

  • 이권순;서진호;이진우
    • 동력기계공학회지
    • /
    • 제10권1호
    • /
    • pp.83-89
    • /
    • 2006
  • Recently, the seriousness of high blood pressure was appeared as the most frequent disease of a the whole sickness in the world. However, the treatment of this disease is uncertain and produces an adverse reaction of a medicine therapy. Also, the patients are burdened with a fee for medical treatment. Therefore, in this paper, we studied effectively and financially to execute the treatment of high blood pressure using the Chinese medicine theorem that is recently arousing the great interest of the people. The main theories in this paper are blood vessel theory and acupuncture, respectively. Especially, the composed circuit systems are classified the blood pressure depressor part and the meridian points discrimination part, respectively. The blood pressure depressor part is composed generally of low-frequency generation circuit, charging-discharging circuit, and micro-computer circuit. Finally, this research have the advantage of discrimination parts such as regular voltage generating circuit, stimulus circuit, amplifying circuit, and alarm circuit.

  • PDF

SOC 및 SOH 추정을 위한 파라미터 추정기법에 관한 연구 (A Study on the Parameters Estimation for SOC and SOH of the Battery)

  • 박성준;송광석;박성미
    • 한국산업융합학회 논문집
    • /
    • 제23권5호
    • /
    • pp.853-863
    • /
    • 2020
  • As the battery ages, the internal resistance of the battery increases, so the loss due to the internal resistance increases at the same charging current, causing the battery temperature to rise, which further accelerates battery aging. Therefore, it is necessary to optimize the charging conditions according to the aging of the battery or the current charge amount, and to accurately estimate this, estimation of the parameters of the equivalent circuit is most important. This paper proposes a new measurement technique that can measure the internal resistance of a battery by analyzing a specific high frequency voltage and current applied to the battery. In addition, in order to test the validity of the proposed measurement technique, the current charging amount was estimated based on the measured internal resistance, and the terminal voltage of the constant current charging mode was automatically set and operated. As a result, good results were obtained regardless of the battery voltage. If this equipment is installed in the charging device, it is believed that it will be of great help in the stability management of the aging reusable battery.

모듈레이터의 지령충전을 위한 고전압 반도체 스위치 개발 (Development of a High Voltage Semiconductor Switch for the Command Charging o)

  • 박성수;이경태;김상희;조무현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 F
    • /
    • pp.2067-2069
    • /
    • 1998
  • A prototype semiconductor switch for the command resonant charging system has been developed for a line type modulator, which charges parallel pulse forming network(PFN) up to voltage of 5 kV at repetition rates of 60 Hz. A phase controlled power supply provides charging of the 4.7 ${\mu}s$ filter capacitor bank to voltage up to 5 kV. A solid state module of series stack array of sixe matched SCRs(1.6 kV, 50 A) is used as a command charging switch to initiate the resonant charging cycle. Both resistive and RC snubber network are used across each stage of the switch assembly in order to ensure proper voltage division during both steady state and transient condition. A master trigger signal is generated to trigger circuits which are transmitted through pulse transformer to each of the 6 series switch stages. A pulse transformer is required for high voltage trigger or power isolation. This paper will discuss trigger method, protection scheme, circuit simulation, and test result.

  • PDF

이중 주파수 전원의 용량성 결합 플라즈마 식각장비에서 전극하전에 의한 입사이온 에너지분포 변화연구 (Electrode Charging Effect on Ion Energy Distribution of Dual-Frequency Driven Capacitively Coupled Plasma Etcher)

  • 최명선;장윤창;이석환;김곤호
    • 반도체디스플레이기술학회지
    • /
    • 제13권3호
    • /
    • pp.39-43
    • /
    • 2014
  • The effect of electrode charging on the ion energy distribution (IED) was investigated in the dual-frequency capacitively coupled plasma source which was powered of 100 MHz RF at the top electrode and 400 kHz bias on the bottom electrode. The charging property was analyzed with the distortion of the measured current and voltage waveforms. The capacitance and the resistance of electrode sheath can change the property of ion and electron charging on the electrode so it is sensitive to the plasma density which is controlled by the main power. The ion energy distribution was estimated by equivalent circuit model, being compared with the measured distribution obtained from the ion energy analyzer. Results show that the low frequency bias power changes effectively the low energy population of ion in the energy distribution.

저누설 다이오드를 사용한 저전력 압전발전기의 효율 개선에 관한 연구 (Energy Conversion Efficiency Improvement of Piezoelectric Micropower Generator Adopting Low Leakage Diodes)

  • 김혜중;강성묵;김호성
    • 전기학회논문지
    • /
    • 제56권5호
    • /
    • pp.938-943
    • /
    • 2007
  • In this paper, we show that, in case of piezoelectric micropower generator, just replacing Schottky diodes in the bridge rectifier with ultra-low reverse leakage current diodes improves the mechanical-to-electrical energy conversion efficiency by more than 100%. Experimental and PSPICE simulation results show that, due to the ultra-low leakage current, the charging speed of the circuit employing PAD1 is higher than that of the circuit employing Schottky diodes and the saturation voltage of the circuit employing PAD1 is also higher. This study suggests that , when the internal impedance of source is very large (a few tens of $M{\Omega}$) such that maximum charging current is a few microamperes or less, in order to realize literally the energy scavenging system, ultra-low reverse leakage current diodes should be used for efficient energy conversion. Since low-level vibration is ubiquitous in the environment ranging from human movement to large infrastructures and the mechanical-to-electrical energy conversion efficiency is much more critical for use of these vibrations, we believe that the improvement in the efficiency using ultra-low leakage diodes, as found in this work, will widen greatly the application of piezoelectric micropower generator.