• Title/Summary/Keyword: charge-coupled device(CCD)

Search Result 181, Processing Time 0.026 seconds

Real-Time Moving Object Tracking System using Advanced Block Based Image Processing (개선된 블록기반 영상처리기법에 의한 실시간 이동물체 추적시스템)

  • Kim, Dohwan;Cheoi, Kyung-Joo;Lee, Yillbyung
    • Korean Journal of Cognitive Science
    • /
    • v.16 no.4
    • /
    • pp.333-349
    • /
    • 2005
  • In this paper, we propose a real tine moving object tracking system based on block-based image processing technique and human visual processing. The system has two nun features. First, to take advantage of the merit of the biological mechanism of human retina, the system has two cameras, a CCD(Charge-Coupled Device) camera equipped with wide angle lens for more wide scope vision and a Pan-Tilt-Zoon tamers. Second, the system divides the input image into a numbers of blocks and processes coarsely to reduce the rate of tracking error and the processing time. Tn an experiment, the system showed satisfactory performances coping with almost every noisy image, detecting moving objects very int and controlling the Pan-Tilt-Zoom camera precisely.

  • PDF

A Stereo Image Recognition-Based Method for measuring the volume of 3D Object (스테레오 영상 인식에 기반한 3D 물체의 부피계측방법)

  • Jeong, Yun-Su;Lee, Hae-Won;Kim, Jin-Seok;Won, Jong-Un
    • The KIPS Transactions:PartB
    • /
    • v.9B no.2
    • /
    • pp.237-244
    • /
    • 2002
  • In this paper, we propose a stereo image recognition-based method for measuring the volume of the rectangular parallelepiped. The method measures the volume from two images captured with two CCD (charge coupled device) cameras by sequential processes such as ROI (region of interest) extraction, feature extraction, and stereo matching-based vortex recognition. The proposed method makes it possible to measure the volume of the 3D object at high speed because only a few features are used in the process of stereo matching. From experimental results, it is demonstrated that this method is very effective for measuring the volume of the rectangular parallelepiped at high speed.

MTF Measuring Equipment of Optical System for LCD Substrate Inspection (LCD 기판 검사 광학계의 MTF 측정장치 제작)

  • Hong, Sung-Mok;Kim, Hee-Nam;Jo, Jae-Heung;Lee, Yun-Woo;Lee, Hoi-Youn;Yang, Ho-Soon;Lee, In-Won;Jung, Jin-Ho
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.1
    • /
    • pp.37-43
    • /
    • 2007
  • We developed the equipment to measure the MTF(modulation transfer function) of an optical system for automatically inspecting the surface condition of an LCD substrate. We have made an object generator with USAF(United States Air Force) targets of three bar patterns and an integrating sphere, and an image analyzer with a 2 dimensional CCD(charge coupled device) and a relay lens. The MTF of the lens under test was obtained by correcting the measured CTF(contrast transfer function) which is the ratio of the contrast in the image of the USAF target to the contrast in the object. We have measured an optical system of F/13.65 (2.6x), the MTF are 30.6 % tangential plane and 26.1 % sagittal plane at 62.5 1p/mm.

Noise Reduction Method in consideration of bandwidth of Low Pass Filter (저역통과 필터의 대역폭을 고려한 잡음 제거 방법)

  • Yang, Jeong-Ju;Jang, Won-Woo;Kwak, Boo-Dong;Kang, Bong-Soon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.157-159
    • /
    • 2010
  • Most digital cameras apply a Charge Coupled Device(CCD) Sensor or a Complementary Metal Oxide Semiconductor(COMS) Sensor. And the images captured these sensors include unwanted noises. In this paper, we proposed a method of the Noise Reduction(NR) about noise reduction or recovery in the image. The proposed NR method is related to Bandwidth of the Low Pass Filter(LPF). For improvement of NR, we were changing the filter coefficient of the LPF. The results of simulations with various filter coefficients, [1 2 1] in the LPF and [-1 2 -1] in the High Pass Filter(HPF) have ideal frequency bandwidth and high performance. We proposed a filter coefficient [1 2 1] and [-1 2 -1] in the LPF and the HPF respectively.

  • PDF

Sensitivity Improvement Method for Color Capture Device At Low Illumination Conditions (Color Capture Device의 저조도 감도 향상 방안)

  • Kim, Il-Do;Jun, Jae-Sung;Choi, Byung-Sun;Park, Sahng-Gyu
    • Proceedings of the IEEK Conference
    • /
    • 2007.07a
    • /
    • pp.235-236
    • /
    • 2007
  • CCD(Charge-Coupled Device) 혹은 CMOS (Complementary Metal Oxide Semiconductor)와 같은 소자를 이용하여 빛을 전기적 신호인 Image로 재구성하는 촬상소자(Color Capture Device)는 촬영환경이 어두워지면 Dynamic Range가 작아지고, Noise가 상대적으로 심해진다[1][2]. 본 논문에서는 촬영 환경이 어두울 때, Resolution을 Preserving하는 Pixel Pitch가 큰 촬상 소자와 Motion Blur를 억제하는 Exposure Time이 긴 촬상 소자의 조합을 신호처리로 구현하여, 신호의 Power를 향상시켜 Dynamic Range를 키우고 Noise의 Boost-up을 억제하여 SNR(Signal to Noise Ratio)을 향상시키는 방식으로, 촬상 장치의 감도를 향상시켜 화질을 개선하는 방법을 제안한다.

  • PDF

Dosimetric Characteristic of Digital CCD Video Camera for Radiation Therapy

  • Young Woo. Vahc;Kim, Tae Hong.;Won Kyun. Chung;Ohyun Kwon;Park, Kyung Ran.;Lee, Yong Ha.
    • Progress in Medical Physics
    • /
    • v.11 no.2
    • /
    • pp.147-155
    • /
    • 2000
  • Patient dose verification is one of the most important parts in quality assurance of the treatment delivery for radiation therapy. The dose distributions may be meaningfully improved by modulating two dimensional intensity profile of the individual high energy radiation beams In this study, a new method is presented for the pre-treatment dosimetric verification of these two dimensional distributions of beam intensity by means of a charge coupled device video camera-based fluoroscopic device (henceforth called as CCD-VCFD) as a radiation detecter with a custom-made software for dose calculation from fluorescence signals. This system of dosimeter (CCD-VCFD) could reproduce three dimensional (3D) relative dose distribution from the digitized fluoroscopic signals for small (1.0$\times$1.0 cm$^2$ square, ø 1.0 cm circular ) and large (30$\times$30cm$^2$) field sizes used in intensity modulated radiation therapy (IMRT). For the small beam sizes of photon and electron, the calculations are performed In absolute beam fluence profiles which are usually used for calculation of the patient dose distribution. The good linearity with respect to the absorbed dose, independence of dose rate, and three dimensional profiles of small beams using the CCD-VCFD were demonstrated by relative measurements in high energy Photon (15 MV) and electron (9 MeV) beams. These measurements of beam profiles with CCD-VCFD show good agreement with those with other dosimeters such as utramicro-cylindrical (UC) ionization chamber and radiographic film. The study of the radiation dosimetric technique using CCD-VCFD may provide a fast and accurate pre-treatment verification tool for the small beam used in stereotactic radiosurgery (SRS) and can be used for verification of dose distribution from dynamic multi-leaf collimation system (DMLC).

  • PDF

Development of Automatic Hole Position Measurement System using the CCD-camera (CCD-카메라를 이용한 홀 변위 자동측정시스템 개발)

  • 김병규;최재영;강희준;노영식
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.127-130
    • /
    • 2004
  • For the quality control of the industrial products, an automatic hole measuring system has been developed. The measurement device allows X-Y movement due to contact forces between a hole and its own circular cone and the device is attached to an industrial robot. Its measurement accuracy is about 0.04mm. This movement of the plate is measured by two LVDT sensor system. But this system using the LVDT sensors is restricted by high cost and precision of measurement and correspondence of environment so particularly, a vision system with CCD-Camera is discussed in this paper for the above mentioned purpose. The device consists of two of two links jointed with hinge pins basically and, they guarantee free movement of the touch prove attached on the second link in the same plane. These links are returned to home position by the spring plungers automatically after each process for the next one. On the surface of the touch prove, it has a circular white mark for camera recognition. The system detect and notify the center coordinate of capture mark image through the image processing. Its measuring accuracy has been proved to be about $\pm$0.01mm through the repeated implementation over 200 times. This technique will shows the advantage of touch-indirect image capture idea using cone-shaped touch prove in various symmetrical shaped holes particulary, like tapped holes, chamfered holes, etc As a result, we attained our object in a view of the accuracy, economical efficiency, and functionality

  • PDF

A Study on the design of Database for photograph of Road Facilities (도로시설물 관리를 위한 Photo Database 설계에 관한 연구)

  • 엄우학;정동훈;김정현;김병국
    • Spatial Information Research
    • /
    • v.11 no.1
    • /
    • pp.33-40
    • /
    • 2003
  • For effective management of information about establishment and repair of road and road facilities, we built GPS-Van mapping system that CCD Cameras, GPS receivers and INS are integrated and using it surveyed test area. Suggested a scheme that possible put acquired data into photo database systematically. Prototype of road facilities management system using the database shows us that extraction of qualitative information and management are possible through relation attribute information. And it raise cognitive faculty of user about objects using field photographs.

  • PDF

Development of Autometic Tomato Grade System with Using a Color Image Processing (칼라 영상을 이용한 토마토 자동 선별시스템의 개발)

  • 이지훈;최연호;김우현;윤경섭;권우현
    • Proceedings of the IEEK Conference
    • /
    • 2003.07c
    • /
    • pp.2529-2532
    • /
    • 2003
  • The quality of agricultural products is represented a degree of freshness and a special qualify that has a close relation to commercial value. To grade tomatoes, it used to nondestructive equipment of a charge-coupled device(CCD) camera and near-infrared(NIR) spectrum analysis method. The NIR spectrum analysis method is used to determine internal qualities such as a brix and an acidity. The CCD camera is used to measure external qualities like color and a size of tomatoes. This paper explaines the structure and movement of the automatic grade system and applies the algorithm for deformed tomtatoes and characteristics of tomatoes through image processing to the grade system.

  • PDF

Development of Automatic Cucumber Grade System with Using a Color Image processing (컬러 영상처리를 이용한 오이 자동 선별 제어 시스템 개발)

  • Son, Hyun-Woo;Cho, Nae-Su;Kwon, Woo-Hyen;Lim, Sung-Woon;Choi, Yon-Ho;Kim, Woo-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.453-455
    • /
    • 2004
  • The quality of agricultural products is represented a degree of freshness and a special quality related to a commercial value. To grade cucumber, the charge-coupled device(CCD) camera is only used to measure external qualities like color. size and degree of bended cucumber The processed area of the image replaces the weigh of cucumber. That means there is no longer used the weighing beams. The system consists of Image processing system and distributing system. This paper explains the structure and movement of the automatic grade system and applies the algorithm for deformed cucumber and characteristics of cucumber through image processing to the grade system.

  • PDF