• Title/Summary/Keyword: charge-coupled device(CCD)

검색결과 181건 처리시간 0.029초

ANALYSIS OF THE IMAGE SENSOR CONTROL METHOD

  • Park, Jong-Euk;Kong, Jong-Pil;Heo, Haeng-Pal;Kim, Young-Sun;Yong, Sang-Soon
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2007년도 Proceedings of ISRS 2007
    • /
    • pp.464-467
    • /
    • 2007
  • All image data acquisition systems for example the digital camera and digital camcorder, use the image sensor to convert the image data (light) into electronic data. These image sensors are used in satellite camera for high quality and resolution image data. There are two kinds of image sensors, the one is the CCD (charge coupled device) detector sensor and the other is the CMOS (complementary metal-oxide semiconductor) image sensor. The CCD sensor control system has more complex than the CMOS sensor control system. For the high quality image data on CCD sensor, the precise timing control signal and the several voltage sources are needed in the control system. In this paper, the comparison of the CCD with CMOS sensor, the CCD sensor characteristic, and the control system will be described.

  • PDF

줌 렌즈 CCD 카메라를 이용한 3차원 복원 정확도 평가 (Evaluation for 3-D Reconstruction Accuracy Using Zoom-lens CCD Camera)

  • 김성삼;정상용;박홍기;유환희
    • 한국GIS학회:학술대회논문집
    • /
    • 한국GIS학회 2003년도 공동 춘계학술대회 논문집
    • /
    • pp.369-376
    • /
    • 2003
  • 최근 고해상력을 가진 줌 렌즈 CCD(Charge Coupled Device) 카메라가 출시되면서 디지털 영상을 쉽게 취득할 수 있게 되어 일상적인 활용에서부터 컴퓨터 시각(computer vision)이나 사진측량과 같은 전문적인 분야에 이르기까지 다양하게 응용할 수 있는 계기가 마련되고 있다. 현재 상용되고 있는 일반 줌 렌즈 CCD 카메라는 영상을 취득하는 데 많은 장점을 갖고 있으나 실제 영상 취득과정에서 다양한 줌의 이동으로 인하여 표정요소계산 및 카메라 렌즈 오차검정에 상당한 어려움이 발생하여 이에 대한 연구가 진행되어오고 있다. 본 연구에서는 기존에 비측량용 카메라에서 취득된 영상을 해석하는 기법으로 사진측량 분야에서 사용되어온 DLT(Direct Linear Transformation) 모델식과 컴퓨터 시각(computer vision)분야에서 카메라 검정 및 3차원 복원에 사용되고 있는 Tsai 모델식을 도입ㆍ적용하여 표정요소계산 및 3차원 복원정확도를 비교 분석하였다. 그 결과 Tsai 모델식에 의한 결과가 DLT 모델식에 의한 결과보다 정확도 및 안정성면에서 향상된 결과를 보여주고 있어서 Tsai 모델식에 대한 사용이 기대된다.

  • PDF

CCD Signal Processing for Optimal Non-Uniformity Correction

  • Kong, Jong-Pil;Lee, Song-Jae
    • 대한원격탐사학회지
    • /
    • 제26권6호
    • /
    • pp.645-652
    • /
    • 2010
  • The performance of the payload Electro-Optical System (EOS) in satellite system is affected by various factors, such as optics design, camera electronics design, and the characteristics of the CCD (Charge Coupled Device) used, etc. Of these factors, the camera electronics design is somewhat unique in that its operational parameters can be adjusted even after the satellite launch. In this paper, the effect of video gain on the non-uniformity correction performance is addressed. And a new optimal non-uniformity correction scheme is proposed and analyzed using the data from real camera electronics unit based on a TDI (Time Delayed Integration) type of CCD. The test results show that the performance of the conventional non-uniformity correction scheme is affected significantly when the video gain is added. On the other hand, in our proposed scheme, the performance is not dependent on the video gain. The insensitivity of the non-uniformity performance on the video-gain is mainly due to the fact that the correction is performed after the dark signal is subtracted from system response.

CCD 카메라 영상을 이용한 스마트 화재 영상 인식 시스템 (Smart Fire Image Recognition System using Charge-Coupled Device Camera Image)

  • 김장원
    • 한국화재소방학회논문지
    • /
    • 제27권6호
    • /
    • pp.77-82
    • /
    • 2013
  • 본 연구에서는 유무선 TCP/IP 기능과 Pan/Tilt 기능을 갖는 Charge-Coupled Device (CCD) 카메라를 이용하여 화재발생 위치를 추적하고, 스마트 모바일 통신 기능을 탑재한 안드로이드 시스템에 실시간으로 정보를 전달하여 원거리에서 화재를 인식하고 재난을 제어할 수 있는 스마트 화재 인식 시스템을 제안하였다. 제안한 방법을 구현하기 위하여 첫째, 입력영상을 hue saturation intensity (HSI) 변환하여 주변 밝기와 잡영상들을 제거하여 순수한 화염만을 분할하는 알고리즘을 제안하였다. 둘째, Pan/Tilt 기능으로 화재가 발생한 위치를 정확하게 추적하여 적절하게 화재 인식을 할 수 있도록 하였다. 셋째, 모바일 기능을 탑재한 안드로이드 통신시스템으로 화재상황을 원격지에서도 확인할 수 있는 스마트한 화재 인식 시스템을 구현할 수 있도록 하였다. 제안한 방법을 확인하기 위하여 10개의 화재 동영상을 입력하고 실험을 수행한 결과 10개의 동영상에서 화재영역을 분할하고 화재 위치를 모두 추적하였다.

휴대용 단말 기반 의료용 무선 방사선 모니터링 시스템 개발 (Development of a Portable Device Based Wireless Medical Radiation Monitoring System)

  • 박혜민;홍현승;김정호;주관식
    • Journal of Radiation Protection and Research
    • /
    • 제39권3호
    • /
    • pp.150-158
    • /
    • 2014
  • 각 의료기관 내 방사선 관련 종사자나 방사선 치료환자들은 진단 및 치료 시 필연적으로 의료상 피폭을 수반하게 된다. 국제방사선방호위원회(ICRP) 권고나 국제원자력기구(IAEA)의 기준에 따라 기준선량 제약치를 적용 및 권고 받고 있지만 1차 피폭대상자인 종사자나 환자들의 피폭최적관리를 위해서는 잠재적인 피폭대상자들에게 기존의 피폭관리 시스템보다 직접적이고 가용성이 높은 측정 및 분석 방법이 필요하다. 따라서 본 연구에서는 기존에 구비된 휴대용 단말과 연동하여 원거리에서 실시간으로 방사선 모니터링이 가능한 시스템을 개발하였다. 모니터링 시스템은 검출부, 영상부, 통신부 세 부분으로 구성되었다. 검출부는 시스템의 소형화를 위해 실리콘 광증배소자(silicon photomultiplier) 기반 섬광검출기를 설계하였으며, 영상부는 무선 CCD (charge-coupled device)카메라 모듈을 사용하여 검출부와 함께 Bluetooth 통신모듈을 통해 휴대용 단말로 측정된 방사선 정보와 영상이 전송된다. 제작된 시스템은 성능 평가를 위해 진단용 X-ray 발생장치와 $^{137}Cs$, $^{22}Na$, $^{60}Co$, $^{204}Tl$, $^{90}Sr$ 선원을 사용하였다. 측정결과를 통해 개발된 시스템은 gamma, beta, X-ray에 대해서 검출 반응성을 확인하였고, 방사선 세기에 따른 응답 선형성과 MCNPX 전산코드를 이용한 측정 거리에 따른 시스템의 검출 정확도 평가 시 3% 내외의 오차범위를 확인하였다. 본 연구의 결과는 방사선 검출 시스템 구성의 비용절감 효과와 개인피폭정도관리에 기여할 것으로 기대한다.

이물질 검출을 위한 X-Ray 비파괴검사 장비 개발 (Development of X-ray Non-destructive Testing (NDT) Equipment for the Detection of Alien Substances)

  • 유영태;오준호;김진우
    • 한국기계가공학회지
    • /
    • 제18권8호
    • /
    • pp.60-66
    • /
    • 2019
  • This study aims to develop and manufacture a device for inspecting impurities in a sealed aluminum container using an X-ray technique. Two X-ray oscillators and detectors are used to detect the entire sample. The stage for sample movement was fabricated using two high-voltage generators and X-ray detectors arranged diagonally. In addition, the high-voltage generator is composed of a vacuum tube, a high-voltage generator, and circulating oil for cooling. It includes a control unit for controlling other equipment, a power supply unit, and a video output unit; the most important part of the X-ray is the X-ray generation part. In this study, a flat panel was used along with the aim of developing the detector part. In particular, the development of the scintillator introduced in this study is a primary focus. The developed scintillator can be combined with a lens and can then be assembled with a charge coupled device (CCD) sensor.

CCD 카메라를 이용한 전자빔 조사량의 예측 (Estimation of Electron Dose Rate using CCD Camera)

  • 김진규;김영민;김윤중;이상희;홍기민;오상호
    • Applied Microscopy
    • /
    • 제39권1호
    • /
    • pp.79-83
    • /
    • 2009
  • We report a useful method to estimate the electron dose rate which may be a decisive factor to characterize sample properties. Even though most mircoscopes have their own exposure meters, there are several practical concerns when such exposure meters are used to measure the electron dose rate: 1) Specimen should be avoided within the entire area of exposure meter; 2) beam current has to be always recorded whenever the operation mode is changed; 3) the electron dose rate can not be calculated for the beam current beyond the detectable range. To overcome these limitations, we suggest a useful method which utilize a CCD (charge coupled device) camera which is now a popular detector to obtain the final electron micrographs. We have evaluated the CCD sensitivity using the linear relationship between electron current on the exposure meter and counter ratio on the CCD camera which are built in KBSI-HVEM (high voltage electron microscope). Applying the new method, we obtained the CCD sensitivity which are approximately 0.039 counts/$e^-$ and 1.37 counts/$e^-$ for the Top-TV and the HV-GIF CCD cameras, respectively.

광삼각법을 이용한 비접촉 3차원 족형 측정 시스템 설계 (Development of a Noncontact Three Dimensional Foot Form Measurement System with Optical Triangulation)

  • 박인덕;안형회;송강석;이희만;김시경
    • 제어로봇시스템학회논문지
    • /
    • 제9권5호
    • /
    • pp.368-373
    • /
    • 2003
  • This paper presents a cost-effective 3D foot scanner system that provides the 3-dimensional point cloud foot data to design the custom footwear. To measure the 3-dimensional point cloud data of the foot, a CCD camera, a Non-Gaussian laser line projector and optical triangulation method are employed. Furthermore, the integrated system employs a measurement base, a frame grabber, a CCD moving cart, a stepping motor and a computer. The measurement result is saved as 3D dxf format and it could be converted to 2D essential data fer a shoe design. The experimental results demonstrate that the proposed system have the decent resolution of 1mm which is enough for last and shoe design.

퍼지제어를 이용한 카메라가 장착된 이동로봇의 경로제어 (Fuzzy Navigation Control of Mobile Robot equipped with CCD Camera)

  • 조정태;이석원;남부희
    • 산업기술연구
    • /
    • 제20권B호
    • /
    • pp.195-200
    • /
    • 2000
  • This paper describes the path planning method in an unknown environment for an autonomous mobile robot equipped with CCD(Charge-Coupled Device) camera. The mobile robot moves along the guideline. The CCD camera is used for the detection of the existence of a guideline. The wavelet transform is used to find the edge of guideline. It is possible for us to do image processing more easily and rapidly by using wavelet transform. We make a fuzzy control rule using image data as an input then determined the position and the navigation of the mobile robot. The center value of guideline is the input of fuzzy logic controller and the steering angle of the mobile robot is the fuzzy controller output. Some actual experiments show that the mobile robot effectively moves to target position by means of the applied fuzzy control.

  • PDF

영상 센서별 제어시스템 특성 분석

  • 박종억;공종필;김영선;용상순
    • 천문학회보
    • /
    • 제37권2호
    • /
    • pp.225.1-225.1
    • /
    • 2012
  • 본 논문에서는 다양한 정보 획득을 목적으로 설계되는 카메라의 핵심 부품인 영상센서의 종류별 동작 특성에 대해 분석하였다. 카메라의 영상센서는 기본적으로 카메라 광학계 설계에 영향을 받으며, 운용의 편이성, 획득 영상의 품질 및 사용되는 환경에 따라 적당한 영상센서가 선택되어 사용된다. 용도에 따라 탑재체에 할당된 무게 및 크기가 제한되므로, 적당한 광학계의 크기와 목표 영상 획득을 위해 센서의 화소면 크기가 결정된다. 가시광선 영역에서는 CCD(Charge Coupled Device), CMOS(complementary metal-oxide semiconductor) 및 NMOS 등의 종류별 영상센서가 사용될 수 있으며, 충분한 광량 확보를 위해서는 넓은 크기의 화소를 보유한 센서가 필요하지만, 이 경우 광학계의 크기와 무게가 증가하여 한정된 자원이 허락된 탑재체 설계에 부담이 된다. 제어단 설계시 빛의 수광 능력이 좋은 CCD 영상 센서를 사용할 경우 좀 더 복잡하고 비교적 높은 소비전력이 요구되는 전자부가 설계되며, 상대적으로 간단한 제어단이 요구되는 CMOS 센서의 경우, 빛의 수광 능력이 CCD에 비해 떨어진다는 단점이 있다. 이 논문에서는 두 가지 영상 센서의 특성 분석을 통해 영상 시스템 설계시 영상 센서 선택에 필요한 고려 사항에 대해 분석하였고, 효율적인 영상 시스템 설계 방안에 대해 서술하였다.

  • PDF