• 제목/요약/키워드: charge detector

검색결과 198건 처리시간 0.021초

Preliminary Research of CZT Based PET System Development in KAERI

  • Jo, Woo Jin;Jeong, Manhee;Kim, Han Soo;Kim, Sang Yeol;Ha, Jang Ho
    • Journal of Radiation Protection and Research
    • /
    • 제41권2호
    • /
    • pp.81-86
    • /
    • 2016
  • Background: For positron emission tomography (PET) application, cadmium zinc telluride (CZT) has been investigated by several institutes to replace detectors from a conventional system using photomultipliers or Silicon-photomultipliers (SiPMs). The spatial and energy resolution in using CZT can be superior to current scintillator-based state-of-the-art PET detectors. CZT has been under development for several years at the Korea Atomic Energy Research Institute (KAERI) to provide a high performance gamma ray detection, which needs a single crystallinity, a good uniformity, a high stopping power, and a wide band gap. Materials and Methods: Before applying our own grown CZT detectors in the prototype PET system, we investigated preliminary research with a developed discrete type data acquisition (DAQ) system for coincident events at 128 anode pixels and two common cathodes of two CZT detectors from Redlen. Each detector has a $19.4{\times}19.4{\times}6mm^3$ volume size with a 2.2 mm anode pixel pitch. Discrete amplifiers consist of a preamplifier with a gain of $8mV{\cdot}fC^{-1}$ and noise of 55 equivalent noise charge (ENC), a $CR-RC^4$ shaping amplifier with a $5{\mu}s$ peak time, and an analog-to-digital converter (ADC) driver. The DAQ system has 65 mega-sample per second flash ADC, a self and external trigger, and a USB 3.0 interface. Results and Discussion: Characteristics such as the current-to-voltage curve, energy resolution, and electron mobility life-time products for CZT detectors are investigated. In addition, preliminary results of gamma ray imaging using 511 keV of a $^{22}Na$ gamma ray source were obtained. Conclusion: In this study, the DAQ system with a CZT radiation sensor was successfully developed and a PET image was acquired by two sets of the developed DAQ system.

$HgI_2$ 방사선 검출기의 누설전류 저감에 관한 연구 (Study on the dark current reduction of $HgI_2$ radiation detector)

  • 신정욱;강상식;김진영;김경진;박성광;조흥래;이형원;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 추계학술대회 논문집 Vol.17
    • /
    • pp.456-459
    • /
    • 2004
  • Analog film/screen systems have been being changed to a digital x-ray imaging device using direct conversion materials. Photocoductors for a direct detection flat-panel imager require high x-ray absorption, ionization and charge collection, low leakage current and large area deposition. In this work, $HgI_2$ films with excellent properties for x-ray detector were deposited by screen printing method. The thickness of $HgI_2$ film was about $150\;{\mu}m$. The passivation layer is fabricated using a-Se and parlyene, the both fabrication $HgI_2$ film were compared for analyzing the leakage current reduction. We measured electrical properties-leakage current, photosensitivity, SNR though I-V measurement, As the result, $HgI_2$ film using a-Se passivation layer had the greater

  • PDF

High Performance of SWIR HgCdTe Photovoltaic Detector Passivated by ZnS

  • ;안세영;서상희;김진상
    • 센서학회지
    • /
    • 제13권2호
    • /
    • pp.128-132
    • /
    • 2004
  • Short wave infrared (SWIR) photovoltaic devices have been fabricated from metal organic vapour phase epitaxy (MOVPE) grown n- on p- HgCdTe films on GaAs substrates. The MOVPE grown films were processed into mesa type discrete devices with wet chemical etching employed for meas delineation and ZnS surface passivatlon. ZnS was thermally evaporated from effusion cell in an ultra high vacuum (UHV) chamber. The main features of the ZnS deposited from effusion cell in UHV chamber are low fixed surface charge density, and small hysteresis. It was found that a negative flat band voltage with -0.6 V has been obtained for Metal Insulator Semiconductor (MIS) capacitor which was evaporated at $910^{\circ}C$ for 90 min. Current-Voltage (I-V) and temperature dependence of the I-V characteristics were measured in the temperature range 80 - 300 K. The Zero bias dynamic resistance-area product ($R_{0}A$) was about $7500{\Omega}-cm^{2}$ at room temperature. The physical mechanisms that dominate dark current properties in the HgCdTe photodiodes are examined by the dependence of the $R_{0}A$ product upon reciprocal temperature. From theoretical considerations and known current expressions for thermal and tunnelling process, the device is shown to be diffusion limited up to 180 K and g-r limited at temperature below this.

마이크로파 전력전송시스템의 프로토타입 설계 및 구현 (A Design and Implementation of a Prototype Microwave Power Transmission System)

  • 박민우;박진우;백승진;구자경;임종식;안달
    • 한국산학기술학회논문지
    • /
    • 제10권9호
    • /
    • pp.2227-2235
    • /
    • 2009
  • 본 논문에서는 마이크로파를 이용하는 무선 전력전송시스템의 간단한 구성과 측정한 동작 특성을 제시한다. 마이크로파 전력전송시스템은 건물 안, 회의실과 같은 좁은 공간내에서 저전력을 이동 단말 기기에 공급하는 것을 목표로 한다. 실험실 수준에서 프로토타입 시스템의 제작 및 측정이 용이하도록 각 구성 회로 소자들을 직접 설계 및 제작, 측정하였는데, 마이크로파 발진기, 고출력증폭기, 마이크로스트립 패치 안테나, 저역통과여파기, 검파 및 정류회로이다. 마이크로파 무선전력전송 시스템은 중심주파수 2.4GHz에서 고정 전력 29.3dBm을 생성하여 전송하고, 수신측 패치 안테나를 수신한 전력을 정류기를 통해서 DC 전력으로 변환한다. 두 안테나간 이격 거리에 따라 측정되는 DC 전압값의 차이를 제시하고, 각 거리별로 수신측에 전달되는 DC전력량이 서로 다름을 측정값으로 제시한다.

A novel approach in voltage transient technique for the measurement of electron mobility and mobility-lifetime product in CdZnTe detectors

  • Yucel, H.;Birgul, O.;Uyar, E.;Cubukcu, S.
    • Nuclear Engineering and Technology
    • /
    • 제51권3호
    • /
    • pp.731-737
    • /
    • 2019
  • In this study, a new measurement method based on voltage transients in CdZnTe detectors response to low energy photon irradiations is applied to measure the electron mobility (${\mu}_e$) and electron mobility-lifetime product $({\mu}{\tau})_e$ in a CdZnTe detector. In the proposed method, the pulse rise times are derived from low energy photon response to 59.5 keV($^{241}Am$), 88 keV($^{109}Cd$) and 122 keV($^{57}Co$) ${\gamma}-rays$ for the irradiation of the cathode surface at each detector for different bias voltages. The electron $({\mu}{\tau})_e$ product was then determined by measuring the variation in the photopeak amplitude as a function of bias voltage at a given photon energy using a pulse-height analyzer. The $({\mu}{\tau})_e$ values were found to be $(9.6{\pm}1.4){\times}10^{-3}cm^2V^{-1}$ for $1000mm^3$, $(8.4{\pm}1.6){\times}10^{-3}cm^2V^{-1}$ for $1687.5mm^3$ and $(7.6{\pm}1.1){\times}10^{-3}cm^2V^{-1}$ for $2250mm^3$ CdZnTe detectors. Those results were then compared with the literature $({\mu}{\tau})_e$ values for CdZnTe detectors. The present results indicate that, the electron mobility ${\mu}_e$ and electron $({\mu}{\tau})_e$ values in CdZnTe detectors can be measured easily by applying voltage transients response to low energy photons, utilizing a fast signal acquisition and data reduction and evaluation.

Multi-channel analyzer based on a novel pulse fitting analysis method

  • Wang, Qingshan;Zhang, Xiongjie;Meng, Xiangting;Wang, Bao;Wang, Dongyang;Zhou, Pengfei;Wang, Renbo;Tang, Bin
    • Nuclear Engineering and Technology
    • /
    • 제54권6호
    • /
    • pp.2023-2030
    • /
    • 2022
  • A novel pulse fitting analysis (PFA) method is presented for the acquisition of nuclear spectra. The charging process of the feedback capacitor in the resistive feedback charge-sensitive preamplifier is equivalent to the impulsive pulse, and its impulse response function (IRF) can be obtained by non-linear fitting of the falling edge of the nuclear pulse. The integral of the IRF excluding the baseline represents the energy deposition of the particles in the detector. In addition, since the non-linear fitting process in PFA method is difficult to achieve in the conventional architecture of spectroscopy system, a new multi-channel analyzer (MCA) based on Zynq SoC is proposed, which transmits all the data of nuclear pulses from the programmable logic (PL) to the processing system (PS) by high-speed AXI-Stream in order to implement PFA method with precision. The linearity of new MCA has been tested. The spectrum of 137Cs was obtained using LaBr3(Ce) scintillator detector, and was compared with commercial MCA by ORTEC. The results of tests indicate that the MCA based on PFA method has the same performance as the commercial MCA based on pulse height analysis (PHA) method and excellent linearity for γ-rays with different energies, which infers that PFA method is an effective and promising method for the acquisition of spectra. Furthermore, it provides a new solution for nuclear pulse processing algorithms involving regression and iterative processes.

Gamma/neutron classification with SiPM CLYC detectors using frequency-domain analysis for embedded real-time applications

  • Ivan Rene Morales;Maria Liz Crespo;Mladen Bogovac;Andres Cicuttin;Kalliopi Kanaki;Sergio Carrato
    • Nuclear Engineering and Technology
    • /
    • 제56권2호
    • /
    • pp.745-752
    • /
    • 2024
  • A method for gamma/neutron event classification based on frequency-domain analysis for mixed radiation environments is proposed. In contrast to the traditional charge comparison method for pulse-shape discrimination, which requires baseline removal and pulse alignment, our method does not need any preprocessing of the digitized data, apart from removing saturated traces in sporadic pile-up scenarios. It also features the identification of neutron events in the detector's full energy range with a single device, from thermal neutrons to fast neutrons, including low-energy pulses, and still provides a superior figure-of-merit for classification. The proposed frequency-domain analysis consists of computing the fast Fourier transform of a triggered trace and integrating it through a simplified version of the transform magnitude components that distinguish the neutron features from those of the gamma photons. Owing to this simplification, the proposed method may be easily ported to a real-time embedded deployment based on Field-Programmable Gate Arrays or Digital Signal Processors. We target an off-the-shelf detector based on a small CLYC (Cs2LiYCl6:Ce) crystal coupled to a silicon photomultiplier with an integrated bias and preamplifier, aiming at lightweight embedded mixed radiation monitors and dosimeter applications.

Fractional-N PLL (Phase-Locked Loop) 주파수 합성기 설계 (Fractional-N PLL Frequency Synthesizer Design)

  • 김선철;원희석;김영식
    • 대한전자공학회논문지TC
    • /
    • 제42권7호
    • /
    • pp.35-40
    • /
    • 2005
  • 본 논문에서는 900MHz 대역 중저속 무선 통신용 칩에 이용되는 3차 ${\Delta}{\sum}$ modulator를 사용한 Fractional-N PLL 주파수 합성기를 설계 및 제작하였다 우수한 위상노이즈 특성을 얻기 위해 노이즈 특성이 좋은LC VCO를 사용하였다. 그리고 고착시간을 줄이기 위해서 Charge Pump의 펌핑 전류를 주파수 천이 값에 따라 조절할 수 있도록 제작하였고 PFD의 참조 주파수를 3MHz까지 높였다. 또한 참조 주파수를 높이는 동시에 PLL의 최소 주파수 천이 간격을 10KHz까지 줄일 수 있도록 하기위하여 36/37 Fractional-N 분주기를 제작하였다. Fractional Spur를 줄이기 위해서 3차 ${\Delta}{\sum}$ modulator를 사용하였다. 그리고 VCO, Divider by 8 Prescaler, PFD, 및 Charge Pump는 0.25um CMOS공정으로 제작되었으며, 루프 필터는 외부 컴포넌트를 이용한 3차RC 필터로 제작되었다. 그리고 Fractional-N 분주기와 3차 ${\Delta}{\sum}$ modulator는 VHDL 코드로 작성되었으며 Xilinx Spartan2E을 사용한 FPGA 보드로 구현되었다. 측정결과 PLL의 출력 전력은 약 -11dBm이고, 위상노이즈는 100kHz offset 주파수에서 -77.75dBc/Hz이다. 최소 주파수 간격은 10kHz이고, 최대 주파수 천이는 10MHz이고, 최대 주파수 변이 조건에서 고착시간은 약 800us이다.

3차원 유한요소해석을 이용한 기체전자증폭기의 1차 전자수집효율의 계산 (Calculation of Primary Electron Collection Efficiency in Gas Electron Multipliers Based on 3D Finite Element Analysis)

  • 김호경;조민국;정민호;손철순;황성진;고종수;조효성
    • Journal of Radiation Protection and Research
    • /
    • 제30권2호
    • /
    • pp.69-75
    • /
    • 2005
  • 기체전자증폭기(GEM, gas electron multiplier)는 동박이 양면으로 도포된 절연기관에 미세구멍배열을 형성한 박막으로 기존의 기체형 방사선 검출기의 미약한 방사선 신호를 증폭하기 위해 널리 사용되어지고 있다. 미세구멍 내부에 강한 전기장을 형성함으로써 이 내부로 유입되는 전자에 충분한 에너지를 전달, 전자사태를 유도하는 원리를 이용한다. 따라서 GEM의 특성은 GEM을 포함한 방사선 검출기에 인가되는 전압 즉, 전기장의 분포에 의해 결정된다. 따라서 올바르지 못한 전기장의 분포에 대해서는 신호 전자가 수집전극으로 향하지 못하고, GEM의 상 하단의 전극으로 이동, 신호의 손실을 초래할 수도 있다. 본 논문에서는 GEM의 가장 중요한 성능 지표 중 하나인 1차 전자수집효율(primary electron collection efficiency)을 계산하였다. 방사선에 의해 발생된 전자는 전기력선을 따라서만 움직인다는 가정 하에, GEM의 단위 구조에 대해 표류전극에서의 전기력선의 수에 대한 수집전극에서의 전기력선의 수의 비로 전자수집효율을 계산하였다. 전기력선의 계산은 3차원 유한요소법을 이용하여 계산하였다. 본 논문에서 사용한 방법은 가장 이상적인 상황으로 국한되지만, GEM의 설계 및 최적 운전변수 도출에 유용하게 사용될 수 있을 것이다.

고속 영상 검지기 시스템 개발에 관한 연구 (A Study On Development of Fast Image Detector System)

  • 김병철;하동문;김용득
    • 전자공학회논문지SC
    • /
    • 제41권1호
    • /
    • pp.25-32
    • /
    • 2004
  • 교통 분야에서도 역시 영상을 이용한 시스템의 개발이 주요 이슈가 되고 있다. 이는 영상을 이용한 시스템의 경우 설치비용이 기존 시스템들에 비해 엄청나게 저렴하다는 것과 설치하는 기간 중에도 교통의 흐름을 거의 방해하지 않고 설치가 가능하다는 장점을 가지고 있기 때문이다. 본 연구에서는 임베디드 시스템 환경에서 영상 검지기 시스템의 구현을 제안하였다. 전체 시스템은 호스트 컨트롤러 보드부분과 영상처리 보드 부분으로 나뉜다. 호스트 컨트롤러 보드 부분은 전체 시스템의 제어와 외부와의 인터페이스, 그리고 OSD(On Screen Display) 부분을 담당하게 된다. 영상처리 보드 부분은 알고리즘의 적용, 마우스 신호의 베어를 담당하고 있다 그리고 안정적인 호스트 컨트롤러의 보드의 운영을 위해 uC/OS-II 를 호스트 컨트롤러 보드에 포팅하였다.