• 제목/요약/키워드: charge detector

검색결과 198건 처리시간 0.023초

고속동작과 빠른 Acquisition 특성을 가지는 Charge Pump PLL의 최적설계에 관한 연구 (A Study on the Optimum Design of Charge Pump PLL for High Speed and Fast Acquisition)

  • 우영신;성만영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 B
    • /
    • pp.718-720
    • /
    • 1999
  • This paper describes a charge pump PLL architecture which achieves high frequency operation and fast acquisition. This architecture employs multi-phase frequency detector comprised of precharge type phase frequency detector and conventional phase frequency detector. Operation frequency is increased by using precharge type phase frequency detector when the phase difference is small and acquisition time is shortened by using conventional phase frequency detector and increased charge pump current when the phase difference is large. By virtue of this multi-phase frequency detector structure, the maximum operating frequency of 694MHz at 3.0V and faster acquisition were achieved by simulation.

  • PDF

Signal Shapes from a Closed-ended Coaxial HPGe Detector

  • Park, H. D.
    • Nuclear Engineering and Technology
    • /
    • 제29권6호
    • /
    • pp.451-458
    • /
    • 1997
  • Signal shapes from a closed-ended coaxial HPGe detector are investigated by numerical methods. The detector used in this study has a volume of 72 ㎤ with relative efficiency of 15%. The electric field and potential distributions in the detector are determined by solving the Poisson equation at the depletion and operating bias. Hence the time dependent signal shapes induced on the electrode are obtained from the energy balance consideration and tv solving the equation of motion for the charge carriers. For various initial positions of a charge carrier pair, the collection times of induced charge vary in the range of 70 - 404 nsec.

  • PDF

ANALYSIS OF CHARGE COLLECTION EFFICIENCY FOR A PLANAR CdZnTe DETECTOR

  • Kim, Kyung-O;Kim, Jong-Kyung;Ha, Jang-Ho;Kim, Soon-Young
    • Nuclear Engineering and Technology
    • /
    • 제41권5호
    • /
    • pp.723-728
    • /
    • 2009
  • The response property of the CZT detector ($5{\times}5{\times}5\;mm^3$), widely used in photon spectroscopy, was evaluated by considering the charge collection efficiency, which depends on the interaction position of incident radiation, A quantitative analysis of the energy spectra obtained from the CZT detector was also performed to investigate the tail effect at the low energy side of the full energy peak. The collection efficiency of electrons and holes to the two electrodes (i.e., cathode and anode) was calculated from the Hecht equation, and radiation transport analysis was performed by two Monte Carlo codes, Geant4 and MCNPX. The radiation source was assumed to be 59.5 keV gamma rays emitted from a $^{241}Am$ source into the cathode surface of this detector, and the detector was assumed to be biased to 500 V between the two electrodes. Through the comparison of the results between the Geant4 calculation considering the charge collection efficiency and the ideal case from MCNPX, an pronounced difference of 4 keV was found in the full energy peak position. The tail effect at the low energy side of the full energy peak was confirmed to be caused by the collection efficiency of electrons and holes. In more detail, it was shown that the tail height caused by the charge collection efficiency went up to 1000 times the pulse height in the same energy bin at the calculation without considering the charge collection efficiency. It is, therefore, apparent that research considering the charge collection efficiency is necessary in order to properly analyze the characteristics of CZT detectors.

experiment and its upgrade with the large silicon charge detector

  • Lee, Jik;Nam, Ji-Woo;Park, Il-Hung;Yang, Jong-Man;Lee, Hye-Young;Na, Go-Woon;Jeon, Jin-A;Suh, Jung-Eun;Lim, Sun-In;Lee, Moo-Hyun;Seo, Eun-Suk
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 2011년도 한국우주과학회보 제20권1호
    • /
    • pp.20.2-20.2
    • /
    • 2011
  • The NASA Antarctica balloon experiment CREAM has successfully collected the data of energetic cosmic rays during flights in past years. We will present the recent analysis results of the CREAM experiment. We will also report on the launch and recovery process of the latest flight. The silicon charge detector of the CREAM has played the key role in the precision measurement of the charge constitution of energetic cosmic rays. We proposed the upgrade of the CREAM experiment with the installment of a new large silicon charge detector on top of the CREAM instrument. The charge measurement of the large silicon detector with no material in front is expected to improve the accuracy of the CREAM charge measurement drastically when combined with the measurement of the existing double layer silicon detector. We will present the fabrication of the large silicon detector and its performance in the radiation source test as well as in the beam test.

  • PDF

Evaluation of a Fabricated Charge Sensitive Amplifier for a Semiconductor Radiation Detector

  • Kim, Han-Soo;Ha, Jang-Ho;Park, Se-Hwan;Lee, Jae-Hyung;Lee, Cheol-Ho
    • Journal of Radiation Protection and Research
    • /
    • 제35권2호
    • /
    • pp.81-84
    • /
    • 2010
  • A CSA(Charge Sensitive Amplifier) was designed and fabricated for application in a radiation detection system based on a semiconductor detector such as Si, SiC, CdZnTe and etc.. A fabricated hybrid.type CSA was evaluated by comparison with a commercially available CSA. A comparison was performed by using calculation of ENC (Equivalent Noise Charge) and by using energy resolutions of fabricated radiation detectors based on Si. In energy resolution comparison, a fabricated CSA showed almost the same performance compared with a commercial one. In this study, feasibility of a fabricated CSA was discussed.

Comparison of Flocculati on-Spectrophotometry and Streaming Current Detector Method to the Control of Flocculants for the Removal of Humic Acid

  • Sang-Kyu Kam;Lee
    • 한국환경과학회지
    • /
    • 제1권2호
    • /
    • pp.137-144
    • /
    • 1992
  • Flocculation-spectrophotometry and streaming current detector( SCD ) method were investigated and compared in order to determine the optimum dosages of synthetic cationic polymers of different charge density and molecular mass for the removal of humic acid. The optimum dosage for each of the polymers was determined with the dosage at which the lowest absorbance of humic acid was shown for the formal. and was determined with the dosage required during charge neutralization of humic acid for the latter It was in good agreement between both methods and there is a strong inverse correlation between the optimum dosage and charge density of the polymers, with highly charged polymer giving the lowest optimum dosage, pointing out the importance the charge neutralization. By flocculation-spectrophotometry, it was found that the absorbance of humid acid with the amount of each of the polymers dosed, changes sharply for polymers of high charge density, but changes rather broadly for polymers of low and middle charge density, Both methods showed that a stoichiometric correlation exists between the optimum dosage of each of the cationic polymers and the negatively charged humic acid.

  • PDF

Comparison of Flocculation-Spectrophotometry and Streaming Current Detector Method to the Control of Flocculants for the Removal of Humic Acid

  • Kam Sang-Kyu;An Lee-Sun;Lee Min-Gyu
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • 제1권2호
    • /
    • pp.137-144
    • /
    • 1997
  • Flocculation-spectrophotometry and streaming current detector(SCD) method were investigated and compared in order to determine the optimum dosages of synthetic cationic polymers of different charge density and molecular mass for the removal of humic acid. The optimum dosage for each of the polymers was determined with the dosage at which the lowest absorbance of humic acid was shown for the former and was determined with the dosage required during charge neutralization of humic acid for the latter. It was in good agreement between both methods and there is a strong inverse correlation between the optimum dosage and charge density of the polymers, with highly charged polymer giving the lowest optimum dosage, pointing out the importance the charge neutralization. By flocculation-spectrophotometry, it was found that the absorbance of humic acid with the amount of each of the polymers dosed, changes sharply for polymers of high charge density, but changes rather broadly for polymers of low and middle charge density. Both methods showed that a stoichiometric correlation exists between the optimum dosage of each of the cationic polymers and the negatively charged humic acid.

  • PDF

2-5 Gb/s 클럭-데이터 복원기를 위한 위상 비교기 설계 연구 (A Design Study of Phase Detectors for the 2.5 Gb/s Clock and Data Recovery Circuit)

  • 이영미;우동식;유상대;김강욱
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2002년도 종합학술발표회 논문집 Vol.12 No.1
    • /
    • pp.394-397
    • /
    • 2002
  • A design study of phase detectors for the 2.5 Gb/s CDR circuit using a standard 0.18-${\mu}{\textrm}{m}$ CMOS process has been performed. The targeted CDR is based on the phase-locked loop and thus it consists of a phase detector, a charge pump, a LPF, and a VCO. For high frequency operation of 2.5 Gb/s, phase detector and charge pump, which accurately compare phase errors to reduce clock jitter, are critical for designing a reliable CDR circuit. As a phase detector, the Hogge phase detector is selected but two transistors are added to improve the performance of the D-F/F. The charge pump was also designed to be placed indirectly input and output.

  • PDF

낙동강 하류 원수의 응집제 주입 자동화를 위한 Streaming Current Detector (SCD)와 Charge Analyzing System (CAS)의 평가 (Evaluation of Streaming Current Detector (SCD) and Charge Analyzing System (CAS) for automation of coagulant dosage determination)

  • 김상구;손희종;이정규;염훈식;유평종
    • 대한환경공학회지
    • /
    • 제39권4호
    • /
    • pp.201-207
    • /
    • 2017
  • 본 연구에서는 낙동강 하류원수에 대한 응집제 주입율 자동화를 위해 stream current detector (SCD)와 charge analyzing system (CAS)의 적용성 비교 평가하였다. SCD 시스템을 이용한 경우, 원수 pH가 9.3에서 5.7로 낮아지면 pH 9.3에서 설정된 유동 전하값을 응집제 주입율로 사용할 수 없었고, pH 5.7에 맞는 유동 전하값의 재설정이 필요하였다. 원수의 pH 변화에 따른 SCD의 유동 전하값의 재설정을 하지 않을 경우, 후단의 모래여과 처리수 탁도가 증가하는 현상을 보였다. CAS 시스템의 경우는 원수 pH의 범위가 6.0~9.3의 범위일 때 polydadmac을 전하 중화제로 사용하는 것이 가능하였고, 고탁도 원수에도 poly-dadmac이 양호한 전하중화제로 평가되었다. 그러나 pH 5~11의 범위에서 polydadmac의 전하량은 거의 변화하지 않은 반면, 응집제로 사용되는 alum의 전하량은 6배 정도 차이가 발생하고, pH에 적합한 응집제 요구량을 보였다. 따라서 원수의 pH가 높은 경우는 전하 적정제로 정수장에서 사용하는 응집제를 직접 이용하는 것이 효율적이었다.

Signal Generation Due to Alpha Particle in Hydrogenated Amorphous Silicon Radiation Detectors

  • Kim, Ho-Kyung;Gyuseong Cho
    • Nuclear Engineering and Technology
    • /
    • 제28권4호
    • /
    • pp.397-404
    • /
    • 1996
  • The hydrogenated amorphous silicon (a-Si : H) holds good promise for radiation detection from its inherent merits over crystalline counterpart. For the application to alpha spectroscopy, the induced charge collection in a-Si : H pin detector diodes ons simulated based on a relevant non-uniform charge generation model. The simulation was peformed for the initial energy and the range of incident alpha particles, detector thickness and the operational parameters such as the applied reverse bias voltage and shaping time. From the simulation, the total charge collection was strongly affected by hole collection as expected. To get a reasonable signal generation, therefore, the hole collection should be seriously considered for detector operational parameters such as shaping time and reverse voltage etc. For the spectroscopy of alpha particle from common alpha sources, the amorphous silicon should have about 70${\mu}{\textrm}{m}$ thickness.

  • PDF