• 제목/요약/키워드: charge/discharge capacity

검색결과 478건 처리시간 0.023초

전력계통 주파수조정을 위한 SOC 기반의 배터리 에너지저장장치 제어전략 (SOC-based Control Strategy of Battery Energy Storage System for Power System Frequency Regulation)

  • 윤준영;유가람;국경수;노도환;장병훈
    • 전기학회논문지
    • /
    • 제63권5호
    • /
    • pp.622-628
    • /
    • 2014
  • This paper presents the SOC-based control strategy of BESS(Battery Energy Storage System) for providing power system frequency regulation in the bulk power systems. As the life cycle of BESS would be shortened by frequent changes of charge and discharge required for frequency regulation in a steady state, the proposed algorithm operates BESS within a range of SOC where its life cycle can be maximized. However, during a transient period of which occurrence frequency is low, BESS would be controlled to use its full capacity in a wider range of SOC. In addition, each output of multiple BESS is proportionally determined by its SOC so that the balance in SOC of multiple BESS can be managed. The effectiveness of the proposed control strategy is verified through various case studies employing a test system. Moreover, the control result of BESS with the measured frequency from a real system shows SOC of BESS can be maintained within a specific range although the frequency deviation is biased.

리튬-공기전지용 탄소/망간산화물 복합구조 공기극의 전기화학적 특성 (Electrochemical Properties of Carbon/Manganese Oxide Composite Air Cathode for Lithium-Air Batteries)

  • 이선영;차은희;모선일;주재백;조원일
    • 전기화학회지
    • /
    • 제15권3호
    • /
    • pp.198-205
    • /
    • 2012
  • 리튬-공기전지 공기극으로서 탄소 상에 직접 수열합성법으로 망간산화물을 생성한 탄소지지 망간산화물 촉매를 합성하였다. 각 수열합성 조건에 따라서 만들어진 복합체에 대한 XRD, FE-SEM 분석을 통하여, 복합체의 결정구조, 형태, 크기 등을 확인하였는데 특히, 수열합성 온도 및 시간이 각각 $170^{\circ}C$, 12시간인 조건에서 만들어진 산화망간은 길이가 40-50 nm인 막대 모양을 갖는 것으로 나타났다. 합성된 복합체를 사용하여 만든 공기극과 리튬금속을 음극으로 하는 코인셀 형태의 리튬-공기전지를 만들어 전기화학적 특성을 조사한 결과 초기 방전 용량이 3,852 mAh/g으로 높았고 충 방전 횟수가 4회 정도 발현되었다.

스핀코팅법에 의한 리튬 2차전지용 산화물 양전극 LiCoO2 박막의 구조 및 전기화학적 특성에 대한 연구 (Structural and Electrochemical Properties of Spin Coated LiCoO2 Cathode Thin Film in Lithium Secondary Batteries)

  • 강성구;유기천
    • 대한화학회지
    • /
    • 제50권3호
    • /
    • pp.243-246
    • /
    • 2006
  • 박막은 Pt/Ti/SiO2/Si 기판 위에 구연산 졸을 이용하여 spin coating에 의해 제작하였다. 기판위에 코팅된 구연산 졸을 380oC에서 15분간 건조시킨 후 750oC에서 10분간 열처리하여 박막을 얻었다. 얻어진 박막은 X-선 회절분석 결과 R3m의 결정구조를 가짐을 알수 있었고, 전기화학적 특성의 측정결과 1차 방전용량은 0.35Ah/cm2-m로 측정되었다.

리튬이온이차전지 음극활물질로써 주석을 첨가한 열분해탄소의 합성과 특성평가 (Synthesis and Characterization of Tin-Pyrolyzed Carbon Composites as Anode Material for Lithium Ion Secondary Batteries)

  • 황윤주;박상호;김애란;;;서은경;남기석
    • 에너지공학
    • /
    • 제19권1호
    • /
    • pp.16-20
    • /
    • 2010
  • 본 연구에서는 바이오매스로 커피원두를 이용하여 합성한 카본재료에 도전재로 주석을 이용하였다. 주석을 첨가하는 방법에 따라 단순 혼합, 화학적인 방법을 이용하여 혼합체를 만들어 시료를 합성하였다. 시료에 대한 XRD를 이용하여 주석과 탄소가 혼합된 구조를 가지고 있음을 확인하였고 SEM을 통한 합성된 시료구입자크기($12{\sim}85\;{\mu}m$)와 형태를 확인하였다. 충 방전 테스트를 실시하여 15사이클에서 카본블랙을 사용했을 때(105 mAh/g)보다 주석을 화학적으로 혼합을 시킨 시료의 경우(191 mAh/g)가 방전용량이 더 높게 나타나는 것을 볼 수 있었고, 주석을 단순 혼합을 실시한 경우에서는 카본블랙과 비슷한 용량(131 mAh/g)을 보였다.

충방전 과정중 구조가 안정한 Zr이 도핑된 LiCoO2 분말 (Structural Stability During Charge-Discharge Cycles in Zr-doped LiCoO2 Powders)

  • 김선혜;심광보;안재평;김창삼
    • 한국세라믹학회지
    • /
    • 제45권3호
    • /
    • pp.167-171
    • /
    • 2008
  • Zirconium-doped $Li_{1.1}Co_{1-x}Zr_xO_2(0{\leq}x{\leq}0.05)$ powders as cathode materials for lithium ion batteries were synthesized using an ultrasonic spray pyrolysis method. Cyclic voltammetry and cyclic stability tests were performed, and the changes of microstructure were observed. The solubility limit of zirconium into $Li_{1.1}CoO_2$ was less than 5 mol%, and monoclinic $Li_2ZrO_3$ phase was formed above the limit. The Zr-doping suppressed the grain growth and increased the lattice parameters of the hexagonal $LiCoO_2$ phase. The Zr-dopiong of 1mol% resulted in the best cyclic performance in the range of $3.0{\sim}4.3V$ at 1C rate (140 mA/g); the initial discharge capacity decreased from 158 mAh/g to 60 mAh/g in the undoped powder, while from 154 mAh/g to 135 mAh/g in the Zr-doped powder of 1 mol% after 30 cycles. The excellent cycle stability of Zr-doped powder was due to the low polarization during chargedischarge processes which resulted from the delayed collapse of the crystal structure of the active materials with Zr-doping.

주석-니켈 나노입자 복합체의 리튬 이차전지 음전극 특성 (Anode Properties of Sn-Ni Nanoparticle Composites for Rechargeable Lithium Batteries)

  • 김광만;강근영;최민규;이영기
    • Korean Chemical Engineering Research
    • /
    • 제49권6호
    • /
    • pp.846-850
    • /
    • 2011
  • 주석과 니켈 나노입자를 함량별로 혼합하여 습식법으로 리튬 이차전지용 복합체 음전극을 제조하고 그 물성과 전기화학적 특성을 조사하였다. 이 음전극은 초기 방전시 최대 700 mAh $g^{-1}$의 우수한 방전용량을 나타내었지만 사이클 특성은 심각한 열화를 보였다. 이것은 나노입자간 단순혼합만으로는 전극판의 기공성과 Ni 성분이 충방전에 따르는 Sn성분의 팽창/수축에 대한 기계적 완충제 역할이 충분하지 않았기 때문이며, 차후 이를 보완하는 나노구조체 Sn-Ni 음전극의 설계와 시험이 필요하다.

Organic Solvents Containing Zwitterion as Electrolyte for Li Ion Cells

  • Krishnan, Jegatha Nambi;Kim, Hyung-Sun;Lee, Jae-Kyun;Cho, Byung-Won;Roh, Eun-Joo;Lee, Sang-Gi
    • Bulletin of the Korean Chemical Society
    • /
    • 제29권9호
    • /
    • pp.1705-1710
    • /
    • 2008
  • Imidazolium based zwitterions, 1,2-dimethylimidazolium-3-n-propanesulfonate (DMIm-3S) and 1-Butylimidazolium-3-n-butanesulphonate (BIm-4S), were synthesized, and utilized them as additive for Li ion cell comprising of graphite anode and $LiCoO_2$ cathode. The use of 10 wt% of DMIm-3S in 1 M $LiPF_6$, EC-EMCDMC (1:1:1 (v/v)) resulted in the increased high rate charge-discharge performance. The low temperature performance of the Li ion cells at about −20 ${^{\circ}C}$ was also enhanced by these zwitterion additives. The DMIm- 3S additive resulted in the better capacity retention by the Li-ion cells even after 120 cycles with 100% depth of discharge (DOD) at 1 C rate in room temperature. Surface morphology of both graphite and $LiCoO_2$ electrode before and after 300 cycles was studied by scanning electron microscopy. An analogous study was performed using liquid electrolyte without any additive.

HFC32/HFC125 혼합냉매의 히트펌프 성능 평가 (Performance of HFC32/HFC125 Mixtures for Heat Pumps)

  • 김욱진;강동규;이요한;정동수
    • 설비공학논문집
    • /
    • 제23권12호
    • /
    • pp.791-798
    • /
    • 2011
  • In this study, performance of R410A(50%R32/50%R125) and HFC32/HFC125 mixture is measured to examine the effect of composition shift of R410A used for various air-conditioners and heat pumps. The composition of HFC32/HFC125 mixture varies from the reference composition of R410A ${\pm}10%$ with 5% interval. Tests carried out in a heat pump bench tester at the evaporation and condensation temperatures of $7/45^{\circ}C$ and $-7/41^{\circ}C$ for summer and winter conditions, respectively. Test results show that both the coefficient of performance (COP) and compressor power of the HFC32/HFC125 mixture have the maximum difference of 2.0% as compared to those of R410A. Compressor discharge temperatures of HFC32/HFC125 mixture are increased up to $6.7^{\circ}C$ as compared to that of R410A. The amount of charge for HFC32/HFC125 mixture vary within 5.6% as compared to that of R410A. Overall, performance of R410A is not appreciably affected by the composition shift of ${\pm}10%$ of R32 under both air-conditioning and heat pumping conditions.

증발기와 응축기 온도변화에 따른 R22 대체냉매 R290 및 R1270의 성능평가 (Performance of R290 and R1270 as Alternative Refrigerants of R22 According to Temperature Variations of Evaporator and Condenser)

  • 백인철;박기정;심윤보;정동수
    • 설비공학논문집
    • /
    • 제18권10호
    • /
    • pp.761-767
    • /
    • 2006
  • In this study, performance of 2 pure hydrocarbons R290 and R1270 was measured in an attempt to substitute R22 under 3 different temperature conditions. They were tested in a refrigerating bench tester with a hermetic rotary compressor. The test bench provided about 3.5 kW capacity and water and water/glycol mixture were employed as the secondary heat transfer fluids. All tests were conducted under the same external conditions resulting in the average saturation temperatures of $7/45^{\circ}C$ and $-7/41^{\circ}C$ and $-21/28^{\circ}C$ in the evaporator and condenser, respectively. Test results show that the coefficient of performance (COP) of these refrigerants is up to 11.54% higher than that of R22 in all temperature conditions. Compressor discharge temperatures were reduced by $14{\sim}31^{\circ}C$ with these fluids. There was no problem with mineral oil since the mixtures were mainly composed of hydrocarbons. The amount of charge was reduced up to 58% as compared to R22. Overall, these fluids provide good performance with reasonable energy savings without any environmental problem and thus can be used as long term alternatives for residential air-conditioning and heat pumping application.

증발기와 응축기 온도변화에 따른 R22 대체냉매의 성능평가 (Performance Evaluation of R22 Alternative Refrigerants According to Temperature Variations of Evaporator and Condenser)

  • 백인철;심윤보;정동수
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.58-63
    • /
    • 2006
  • In this study, performance of 2 pure hydrocarbons and 3 mixtures was measured in an attempt to substitute R22 under 3 different temperature conditions. The mixtures were composed of R1270(propylene), R290(propane) and R152a. They were tested in a refrigerating bench tester with a hermetic rotary compressor The test bench provided about 3.5 kW capacity and water and water/glycol mixture were employed as the secondary heat transfer fluids. All tests were conducted under the same external conditions resulting in the average saturation temperatures of $7^{\circ}C/45^{\circ}C$ and $-7^{\circ}C/41^{\circ}C$ and $-21^{\circ}C/28^{\circ}C$ in the evaporator and condenser, respectively. Test results show that the coefficient of performance (COP) of these refrigerants is up to 11.54% higher than that of R22 in all temperature conditions. Compressor discharge temperatures were reduced by $14{\sim}31^{\circ}C$ with these fluids. There was no problem with mineral oil since the mixtures were mainly composed of hydrocarbons. The amount of charge was reduced up to 58% as compared to R22. Overall, these fluids provide good performance with reasonable energy savings without any environmental problem and thus can be used as long term alternatives for residential air-conditioning and heat pumping application.

  • PDF