• Title/Summary/Keyword: characteristics of thermal temperature

Search Result 3,551, Processing Time 0.03 seconds

Thermal expansion and Shrinkage of concrete and Steel bar (고층에서의 콘크리트와 철근의 팽창 및 수축)

  • 오창희;김화중
    • Fire Science and Engineering
    • /
    • v.2 no.1
    • /
    • pp.11-20
    • /
    • 1988
  • The success of analyzing the behavior of reinforced concrete structures at elevated temperature greatly depends on how accurately certain thermal properties, especially thermal expansion, specific heat and density thermal conductivity can be determined in a wide temperature range. In this Paper, in order to Predict the behavior of reinforced concrete structure in fire hazards thermal expansion characteristics of normal concrete are formulated through experimental investigation.

  • PDF

The Fabrication of Pt Micro Heater Using Aluminum Oxide as Medium Layer and Its Thermal Characteristics (알루미늄산화막을 매개층으로 이용한 백금 미세발열체의 제작과 발열특성)

  • 노상수;정귀상
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.331-334
    • /
    • 1997
  • The electrical and physical charateristics of aluminum oxide and Pt thin films on it, deposited by reactive sputtering and DC magnetron sputtering, respectively, were analysed with increasing annealing temperature(400~80$0^{\circ}C$) by four point probe, SEM and XRD. Under $600^{\circ}C$ of annealing temperature, aluminum oxide had the properties of improving Pt adhesion to SiO$_2$and insulation without chemical reaction to Pt thin films and the resistivity of Pt thin finns was improved. But these properties of aluminum oxide and Pt thin finns on it were degraded over $700^{\circ}C$ of annealing temperature because aluminum oxide was changed into metal aluminum and then reacted to Pt thin films deposited on it. The thermal characteristics of Pt micro heater were analysed with Pt-RTD integrated on the same substrate. In the analysis of properties of Pt micro heater. active area was smaller size, Pt micro heater had better thermal characteristics. Temperature of Pt micro heater fabricated on membrane was up to 34$0^{\circ}C$ with 1.2watts of the heating power due to reduction of the external thermal loss.

  • PDF

A Numerical Study on the Heat Transfer Characteristics of a Metal Hydride Reactor with Embedded Heat Pipes (내부에 히트파이프를 삽입한 메탈 하이드라이드 반응기의 열전달 특성에 대한 수치해석 연구)

  • Park, Young-Hark;Boo, Joon-Hong
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2346-2351
    • /
    • 2008
  • This study deals with heat pipes inserted into the metal hydride(MH) reactor to increase the effective thermal conductivity of the system and thus to enhance the thermal control characteristics. A numerical analysis was conducted to predict the effect of inserted heat pipes on the heat transfer characteristics of MH, which inherently has extremely low thermal conductivity. The numerical model was a cylindrical container of O.D. 76.3 mm and length 1 m, which is partially filled with about 60% of MH material. The heat pipe was made of copper-water combination, which is suitable for operation temperature range between $10^{\circ}C$ and $80^{\circ}C$. Both inner -and outer- heat pipes were considered in the model. Less than two hours of transient time is of concern when decreasing or increasing the temperature for absorption and discharge of hydrogen gas. FLUENT, a commercial software, was employed to predict the transient as well as steady-state temperature distribution of the MH reactor system. The numerical results were compared and analyzed from the view point of temperature uniformity and transient time up to the specified maximum or minimum temperatures.

  • PDF

Heat kTransfer Modeling and Characteristics Analysis of Impulsed Magnetizing Fisture (임펄스 착자요크의 열전달 모델링 및 특성 해석)

  • 백수현;김필수
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.3
    • /
    • pp.381-387
    • /
    • 1994
  • In this paper, we found the improved SPICE heat transfer modeling of impulsed magnetizing fixture system and investigated temperature characteristics using the proposed model. As the detailed thermal characteristics of magnetizing fixture can be obtained, the efficient design of the impulsed magnetizing fixture which produce desired magnet will be possible using our heat transfer modeling. The knowledge of the temperature of the magnetizing fixture is very important of forecast the characteristics of the magnetizing fixture which produce desired magnet will be possible using our heat transfer modeling. The knowledge of the temperature of the magnetizing fixture is very important to forecast the characteristics of the magnetizing circuits under different conditions. The capacitor voltage was not raised above 810[V] to protect the magnetizing fixture from excessive heating. The purpose of this work is to compute the temperature increasing for different magnetizing conditions. The method uses multi-lumped model with equivalent thermal resistance and thermal capacitance. The reliable results are obtained by using iron core fixture (stator magnet of air cleaner DC motor) coupled to a low-voltage magnetizer(charging voltage : 1000[V], capacitor : 3825[$\mu$F]. The modeling and experimental results are in close aggrement.

  • PDF

Numerical Analysis on Heat Transfer Characteristics of a Heat Pipe Type Solar Thermal Receiver According to Internal Geometry Variation (고온 히트파이프식 태양열 흡수기의 내부형상 변화에 따른 열전달 특성의 수치해석)

  • Park, Young-Hark;Boo, Joon-Hong;Kang, Yong-Heack
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.165-168
    • /
    • 2008
  • A numerical analysis was conducted to predict the heat transfer characteristics of a solar receiver which is subject to very high heat fluxes and temperatures for solar thermal applications. The concentration ratio of the solar receiver ranges 1000 and the concentrated heat is required to be transported to a certain distance for specific applications. This study deals with a solar receiver according to internal geometry variation incorporating high-temperature heat pipe. The isothermal characteristics in the receiver section is of major concern. The diameter of the solar thermal receiver was 120 mm and the length was 400 mm and the angle of receiver end wall set $90^{\circ},\;60^{\circ},\;45^{\circ},\;30^{\circ}$. And the diameter of the heat pipe was 12.7 mm, 48 axial channels of the same dimensions were attached to the outer wall of the receiver with even spacing in the circumferential direction. The channels are changed to high-temperature sodium heat pipes. Commercial softwares were employed to deal with the radiative heat transfer inside the receiver cavity and the convection heat transfer along the channels. The numerical results are compared and analyzed from the view point of high-temperature solar receiver.

  • PDF

Thermal Buckling Characteristics for Thermal Protection System Panel Using Ritz Method (리츠 법을 이용한 열방어 시스템 패널의 열 좌굴 특성 연구)

  • Lee, Heesoo;Kim, Yongha;Park, Jungsun
    • Journal of Aerospace System Engineering
    • /
    • v.13 no.1
    • /
    • pp.18-28
    • /
    • 2019
  • High speed vehicles are subjected to high thermal loadings due to aerodynamic heating during ascent and reentry. Since a thermal protection system panel is mechanically constrained, it may cause thermal buckling under excessive thermal loadings. The thermal buckling could disturb the field of flow and make aerodynamic characteristics unstable. It is thus necessary to design the thermal protection system panel to prevent thermal buckling. This study defines the analytical model of temperature distribution using the finite difference method for the thermal protection system panel with large temperature differences inside and outside. This paper proposes the approximate model of the thermal buckling characteristics for the thermal protection system panel through the use of the Ritz method. The validity of the present method was verified by comparing the results of the finite element analysis. Furthermore, this research performs the parametric analysis of the thermal buckling characteristics for the thermal protection system panel by using the approximate model.

Characteristics Analysis of Magnetizing Circuit and Fixture considering Temperature Characteristic (온도특성을 고려한 착자회로 및 요크의 특성 해석)

  • Baek, Soo-Hyun;Maeng, In-Jae;Kim, Pill-Soo;Kim, Cherl-Jin
    • Proceedings of the KIEE Conference
    • /
    • 1993.11a
    • /
    • pp.82-84
    • /
    • 1993
  • A method for simulating general characteristics and temperature characteristics of magnetizing fixture coil of the capacitor discharge impulse magnetizer-magnetizing fixture system using SPICE is presented. This method has been developed which can aid the design, understanding and inexpensive, time-saving of magnetizing circuit. As the detailed characteristics of magnetizing circuit can be obtained, the efficient design of the magnetizing circuit which produce desired magnet will be possible using our SPICE modeling. Especially, The knowledge of the temperature of the magnetizing fixture is very important to forecast the characteristics of the magnetizing circuits tinder different conditions. The capacitor voltage was not raised above 810[V] to protect the magnetizing fixture from excessive heating. The temperature estimation method uses multi-lumped model with equivalent thermal resistance and thermal capacitance.

  • PDF

Thermal Characteristics Evaluation of Concentrated Hybrid Panel with cooling system on PV module (PV모듈의 냉각장치를 적용한 집속형 복합패널의 집열 특성 평가)

  • Seo, Yu-Jin;Huh, Chang-Su
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.3
    • /
    • pp.47-52
    • /
    • 2005
  • Normally if sunlight is directed on a solar cell without any increasing in temperature, the amount of absorption energy per unit area of each cell is increasing. In a silicon solar cell. however, cell conversion efficiency decreases with the increase of temperature. Therefore, to maintain cell conversion efficiency under normal condition, it is necessary to keep the cell at operating temperature. We tried to design and make new hybrid panel with cooling system to prevent increasing of temperature on cell, collect and use thermal energy more effectively. We compared performance of this new hybrid panel with current thermal panel. We also evaluated conversion efficiency, thermal capacity and confirmed cooling effects from thermal absorption efficiency.

Performance and Thermal-Flow Characteristics in a Planar Type Solid oxide Fuel Cell with Single Channel and Multi-Channel (단일채널 및 다채널을 포함한 평판형 고체산화물연료전지의 열유동 해석 및 성능평가)

  • Ahn, Hyo-Jung;Cha, Suk-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.12
    • /
    • pp.1033-1041
    • /
    • 2007
  • This paper studied the characteristics of performance and temperature in a unit cell of a planar type SOFC under various conditions by employing computational fluid dynamics (CFD). In order to derive thermal stress distribution and performance characteristics, the 3-D model simulation for a single channel was performed in various conditions which include interconnect materials $(LaCrO_3/AISI430)$, gas flow direction (co-flow/counter-flow) and inlet temperature (923 K/1173 K). From these results of a single channel, the most effective conditions were applied to the unit stack with multi-channel and the temperature distribution is displayed. Considering both thermal stress and performance, the best combination is 923 K inlet temperature, counter-flow and interconnector of stainless steel. As the end results, flow, thermal and current density distributions were found in the model with multi-channel applied to the best combination and were concentrated in the middle of channels than in the edge.

An Experimental Investigation on the Operating Characteristics of a Reversible Loop Heat Pipe (가역 루프 히트파이프의 작동특성에 관한 실험적 연구)

  • Kim Bong-Hun;Choi Joon-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.3
    • /
    • pp.231-239
    • /
    • 2006
  • An experimental investigation of a Reversible Loop Heat Pipe (RLHP) was conducted to determine the operating limits and performance characteristics as functions of the thermophysical parameters, the heat input, and the cooling intensity. Variations in both temperature and heat transport capacity were measured and analyzed in order to accurately evaluate the transient operating characteristics. In addition, the maximum heat transport as a function of the mean evaporator temperature, the ratio of heat transport to heater input power as a function of the mean evaporator temperature, and the overall thermal resistance as a function of the overall heat transport capacity were examined as well. Results indicated that the cooling intensity played an important role on the operating characteristics and performance limitation. The maximum heat transports corresponding to cooling intensity $72W/^{\circ}C$ and $290W/^{\circ}C$ were 446 W and 924 W, respectively. Also, observation of the startup characteristics indicated that the mean evaporator temperature should be maintained between $40^{\circ}C$ and $60^{\circ}C$, and overall thermal resistance were measured as $0.02^{\circ}C/W$.