• Title/Summary/Keyword: characteristic X-ray image

Search Result 68, Processing Time 0.027 seconds

The Characteristic Curves of Commercial Medical X-ray Films (상용 의학용 X-ray 필름의 특성곡선)

  • Heo, Hoon;Jeong, Yeon-Tae;Lee, Jae-Sung
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.19 no.2
    • /
    • pp.12-21
    • /
    • 2001
  • For the purpose of determining characteristics of widely used commercial medical x-ray films, which are used for obtaining the Linac-grams for radiational treatment of cancers, we placed several commercial x-ray films at a fixed distance form the linear accelerator. After varying the exposed amount of radiation step by step, we could obtain a continually increasing density image for each film whose densities were determined by microdensitometer readings. The characteristic curves of the films were obtained by plotting the densities vs. the exposed radiation amounts, and their ${\gamma}$ values were determined. These values can be used to suggest a minimum necessary amount of exposed radiation to get a useful Linac-gram. The measured ${\gamma}$ values of the characteristic curves of the Kodak-DVP/RA-1 film were 1.73 when used 6MV x-ray, 1.70 when used 15MV of intensity. For the Konica-AX film, ${\gamma}$ values were 1.29 and 1.18 respectively. The result suggests that the effective conditions for high resolution of a L-gram be 6 MV of x-ray intensity and about 3 rad of exposed dose on a Kodak-DVP/RA-1 film.

  • PDF

X-선 발생장치 정류방식에 따른 출력특성에 관한 연구

  • Na, Gil-Ju;Baek, Su-Ung;Yang, Hyeon-Hun;Park, Gye-Chun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.126-126
    • /
    • 2009
  • X-ray high-voltage generator is the most important part that can decide the radiation exposure dose affecting a patient or operator according to the characteristic. If decrease of X-ray radiation exposure dose and output characteristic of high-voltage generator is unstable, a patient or operator must be exposed to more radiation. This study measures and analyzes the exposure dose reproducibility and output characteristic according to a change of tube current on the various rectification methods of diagnostic X-ray equipment. It can find that quality bastardize and output is increased if voltage of X-ray tube is increased. Exposure dose reproducibility according to output of X-ray equipment is extremely excellent in inverter type, and is stable in order of following three-phase, a single-phase and condenser method. This study can find that the reply incidence of high-voltage generator is generated due to difference in rectification method, noise occurs in X-ray due to that, quality of an image is decreased due to that, and medical diagnosis can be failed due to that.

  • PDF

3D Coordinates Acquisition by using Multi-view X-ray Images (다시점 X선 영상을 이용한 3차원 좌표 획득)

  • Yi, Sooyeong;Rhi, Jaeyoung;Kim, Soonchul;Lee, Jeonggyu
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.10
    • /
    • pp.886-890
    • /
    • 2013
  • In this paper, a 3D coordinates acquisition method for a mechanical assembly is developed by using multiview X-ray images. The multi-view X-ray images of an object are obtained by a rotary table. From the rotation transformation, it is possible to obtain the 3D coordinates of corresponding edge points on multi-view X-ray images by triangulation. The edge detection algorithm in this paper is based on the attenuation characteristic of the X-ray. The 3D coordinates of the object points are represented on a graphic display, which is used for the inspection of a mechanical assembly.

Development of X-ray PIV Technique and its Application to Blood Flow (X-ray PIV 기법의 개발과 혈액 유동에의 적용연구)

  • Kim, Guk Bae;Lee, Sang Joon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.11 s.242
    • /
    • pp.1182-1188
    • /
    • 2005
  • An x-ray PIV (Particle Image Velocimetry) technique was developed to measure quantitative information on flows inside opaque conduits and on opaque-fluid flows. At first, the developed x-ray PIV technique was applied to flow in an opaque Teflon tube. To acquire x-ray images suitable for PIV velocity field measurements, refraction-based edge enhancement mechanism was employed using detectable tracer particles. The optimal distance between with the sample and detector was experimentally determined. The resulting amassed velocity field data were in reasonable agreement with the theoretical prediction. The x-ray PIV technique was also applied to blood flow in a microchannel. The flow pattern of blood was visualifed by enhancing the diffraction/interference -bas ed characteristic s of blood cells on synchrotron x-rays without any contrast agent or tracer particles. That is, the flow-pattern image of blood was achieved by optimizing the sample (blood) to detector distance and the sample thickness. Quantitative velocity field information was obtained by applying PIV algorithm to the enhanced x-ray flow images. The measured velocity field data show a typical flow structure of flow in a macro-scale channel.

Studies on the Characteristics of Medical X-ray Films Using the High Energy Radiation (고에너지 방사선을 이용한 의학용 x-ray 필름 특성연구)

  • Lee, Jae-Sung;Heo, Hoon
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.20 no.2
    • /
    • pp.153-160
    • /
    • 2002
  • Two different commercial brand X-ray films are used for examining possible differences caused by different target distances when the patients are examined with highenergy X-rays. 6MV- and 15MV X-rays are tested at four different target distances. The films on which the radiation amounts are gradually increased using H$_2$O phantoms are developed by an automatic developing machine to be analysed in the image densities. Characteristic curves have similar shapes for different conditions but for the 130cm target distance. ${\gamma}$ values and average image densities per the illuminated radiation are used to analyse the differences.

  • PDF

Extraction of Intestinal Obstruction in X-Ray Images Using PCM (PCM 클러스터링을 이용한 X-Ray 영상에서 장폐색 추출)

  • Kim, Kwang Baek;Woo, Young Woon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.12
    • /
    • pp.1618-1624
    • /
    • 2020
  • Intestinal obstruction diagnosis method based on X-ray can affect objective diagnosis because it includes subjective factors of the examiner. Therefore, in this paper, a detection method of Intestinal Obstruction from X-Ray image using Hough transform and PCM is proposed. The proposed method uses Hough transform to detect straight lines from the extracted ROI of the intestinal obstruction X-Ray image and bowel obstruction is extracted by using air fluid level's morphological characteristic detected by the straight lines. Then, ROI is quantized by applying PCM clustering algorithm to the extracted ROI. From the quantized ROI, cluster group that includes bowel obstruction's characteristic is selected and small bowel regions are extracted by using object search from the selected cluster group. The proposed method of using PCM is applied to 30 X-Ray images of intestinal obstruction patients and setting the initial cluster number of PCM to 4 showed excellent performance in detection and the TPR was 81.47%.

Acquisition of Monochromatic X-ray Using Multilayer Mirror (다층박막 거울을 이용한 단색 엑스선 획득)

  • Chon, Kwon-Su
    • Journal of radiological science and technology
    • /
    • v.33 no.3
    • /
    • pp.179-184
    • /
    • 2010
  • A hard X-ray microscope system for obtaining images of nano-spatial resolution has been widely studied and requires monochromatic X-ray. A multilayer mirror of 84% reflectivity was designed to acquire tungsten characteristic X-ray of 8.4 keV from the white beam generated from an X-ray tube, and the C/W multilayer mirror of $50{\times}50\;mm$ size and 5.65 nm d-spacing was fabricated by the ion-beam sputtering system. The C/W multilayer had a uniformity of 99.5%, and the structure of the multilayer mirror was verified by a TEM image. The obtainable x-ray reflectivity for the C/W multilayer mirror at 8.4 keV was estimated from measuring the X-ray reflectivity using the copper characteristic X-ray of 8.05 keV. Monochromatic X-ray of 8.4 keV was generated by combining a X-ray tube, and the reflectivity and monochromaticity were 77.1% and 0.21 keV, respectively. Monochromatic X-ray generated from the combination of an X-ray tube and an C/W multilayer mirror has enough potential to use X-ray source for hard X-ray microscope system of laboratory size. If the C/W multilayer mirror of d-spacing of a few nanometers can be fabricated, monochromatic X-ray corresponded to 17.5 keV, molybdenum characteristic X-ray, can be obtained and applied to mammography in the medical application.

Image Analysis for Detection of Defects of BGA by Using X-ray Imaging

  • Sumimoto, Tetsuhiro;Maruyama, Toshinori;Azuma, Yoshiru;Goto, Sachiko;Mondou, Munehiro;furukwa, Noboru;Okada, Saburo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.87.5-87
    • /
    • 2002
  • . A high peak power demand at substations will result under This paper deals with the detection of defects at BGA solder joints in PC boards by using X-ray Imaging. . To improve a cost performance and reliability of PC boards, an inspection of BGA is required in the surface mount process. . Contents 2 We attempt to detect the characteristic of the solder bridges based on an image analysis.

  • PDF

The Characteristic of Temperature and Dose Distribution of intra oral X-ray Tube (강내형 X선 튜브 온도 및 선량 분포 특성)

  • Cho, Sungho;Lee, Rena
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.5
    • /
    • pp.262-266
    • /
    • 2013
  • A new concept of periapical radiography, intra oral x-ray tube and detector system is introduced. It is new system that a miniature x-ray tube is inserted into mouse and it acquired digital image using external detector. In this study, we have investigated temperature and dose distribution of insertional x-ray tube for periapical radiography. To analyze temperature characteristic of x-ray tube, we attached the thermocouple to surface of x-ray tube and we measured the temperature according to distance. Also, we measured the dose distribution of a miniature x-ray tube according to distance. As a result, temperature was constant to $27^{\circ}C$ over 2mm without cooling system, dose distribution of x-ray tube was 3.14 and 1.84mGy in 3 and 5cm, respectively. Therefore, the proposed x-ray system works in lower dose than conventional dental x-ray system. Thus, it is considered that new concept of system will have a significant effect on medical imaging technology.

X-ray Image Processing for the Korea Red Ginseng Inner Hole Detection ( I ) - Preprocessing technique for inner hole detection - (홍삼 내공검출을 위한 X-선 영상처리기술(I) - 내공검출에 적합한 전처리기법 -)

  • 손재룡;최규홍;이강진;최동수;김기영
    • Journal of Biosystems Engineering
    • /
    • v.27 no.4
    • /
    • pp.341-348
    • /
    • 2002
  • Quality evaluation of red ginsengs is determined by outer shape and inner qualities. Especially, the inner qualities are main grading criteria. Currently, red ginsengs are classified into 3-grades; heaven, earth and good. The best heaven grade must not include inner holes and sponge tissues. This study was conducted to develop a red ginseng sorting system using x-ray image processing technique. Because of lens characteristic, gray values of the central region in the x-ray image are higher and gradually decreased towards the edge regions. This difference of gray values gives trouble in segmentation and detection of inner holes in red ginseng image, so preprocessing technique is necessary. The preprocessing was done by subtracting source image from an empty background image. But, simple subtraction was not quite appropriate because of too small contrast between inner holes and sound part. Scaled subtraction images were obtained by multiplying all gray values by some numbers. However this method could not help to set threshold value because the gray values of root part are generally lower than body part when red ginseng is exposed to the x-ray. To determine threshold value for detecting inner holes, an algorithm was developed by increasing overall gray values of less clear images.