• Title/Summary/Keyword: channeling effect

Search Result 33, Processing Time 0.025 seconds

The Influence of Information Asymmetry of Telecommunication Service Websites on Intention for Continuous Usage (통신서비스 웹사이트 정보불균형이 지속이용의도에 미치는 영향)

  • Han, Moon Seung;Lee, John Hearn
    • Journal of Information Technology Services
    • /
    • v.14 no.3
    • /
    • pp.131-146
    • /
    • 2015
  • The communications market can be characterized for its overflow of users, oligopoly business structure, 24/7 open service, incomplete sales, and operation of core platform function. These characteristics have lead users to continuously make complaints and suffer inconveniences, and thus the concept of user protection has come to receive attention. This study aims to propose solutions through communication channeling between businesses and users, based on website construction from the viewpoint of user protection. In particular, a research model was developed to display how the information symmetry of websites can be influential on the satisfaction, reliability, and continuous intention for using communication services. Total of 14 hypotheses were set to measure a significant degree of variables corelation and eight hypotheses were accepted finally. The analysis results showed that information symmetry of telecommunication service websites had a positive effect on intention for continuous usage. Through the research results, it is expected that communication service businesses will be able to consider important factors when constructing websites. Furthermore, the results are expected to be utilized as for ensuring users' continued usage of their communication services.

Improvement of ESD Protection Performance of High Voltage Operating EDNMOS Device with Double Polarity Source (DPS) Structure (DPS(Double Polarity Source) 구조를 갖는 고전압 동작용 EDNMOS 소자의 정전기 보호 성능 개선)

  • Seo, Yong-Jin;Yang, Jun-Won
    • Journal of Satellite, Information and Communications
    • /
    • v.9 no.2
    • /
    • pp.12-17
    • /
    • 2014
  • In this paper, modified EDNMOS device with DPS (double polarity source) structure are suggested to realize stable and robust ESD (electrostatic discharge) protection performance of high voltage operating microchip. This DPS structure inserts the P+ diffusion layer on N+ source side, which in intended to block lateral extension of the electron rich region from N+ source side. Based on our simulation results, the inserted P+ diffusion layer effectively prevents the formation of deep electron channeling induced by high electron injection. As a result, our proposed DPS_EDNMOS devices could overcome the double snapback effect of conventional Std_EDNMOS device.

A Study on the Mass Transfer of Extraction Process by Use of Hollow Fiber Membrane Module (실관막 모듈을 이용한 추출공정의 물질전달에 관한 연구)

  • Kim, Young-Il;Jin, Do-Won;Kim, Jong-Hyun;Choi, Dai-Ung;Park, Dong-Won
    • Applied Chemistry for Engineering
    • /
    • v.7 no.5
    • /
    • pp.977-984
    • /
    • 1996
  • Liquid-liquid extractions by use of hollow fiber membrane module are fast because of the large surface area per volume. In these membranes, the extractant and feed can be contacted at high speed and two flows are completely independent, so there are no problems with loading and channeling. In this paper, it was investigated the selectivities of extractants for extraction of heavy metals from aqueous solution into organic extractants by using the hollow fiber membrane. To identify the effect of distribution ratio on mass transfer in the membrane, we also compared the distribution ratio with mass transfer coefficient. From these experiments for the system with high distribution ratio, effect of the distribution ratio on mass transfer was weak compare with the low distribution ratio system in the hollow fiber membrane.

  • PDF

A Study on Non-proportionality of Phoswich Detector Using Monte Carlo Simulation (몬테칼로 전산모사를 이용한 Phoswich 계측기의 비선형성 연구)

  • Kim, Jae-Cheon;Kim, Jong-Kyung;Kim, Soon-Young;Kim, Yong-Kyun;Lee, Woo-Gyo
    • Journal of Radiation Protection and Research
    • /
    • v.29 no.4
    • /
    • pp.263-268
    • /
    • 2004
  • Using the Monte Carlo simulation, a study on the lion-proportionality of the prototype phoswich detector with $2'{\times}2'$ CSI(Tl) and plastic scintillator, which was made by KAERI, has been carried. The defector response functions (DRFs) calculated by simulations were compared with the experimental measurement on the $^{137}Cs\;and\;^{60}Co$. To precisely simulate the DRF for the phoswich, the CSI(Tl) non-proportionality was calculated using the electron response and the simplified electron cascade sequence for treating the photoelectric absorption event. The resulting DRFs of $^{137}Cs\;and\;^{60}Co$ sources obtained by simulations were compared with experiments for verification. For $^{137}Cs$, gamma-ray responses simulated by MCNP5 are generally good agreement with the measured ones. But the DRF of $^{60}Co$ does not match well with the results of experiment in the energy region below second peak due to the coincidence effect of two gamma-rays (1.17 MeV and 1.33 MeV). Through the analysis of the non-proportionality of CsI(Tl) in the prototype phoswich, the improved DRFs considering non-proportionality were produced and the simulation results were verified using the experimental measurements. However, to more precisely reproduce the DRF for the phoswich, further studies in relation to the electron channeling effect and the Doppler broadening effect of a scintillator are still needed as well as considering that effect of the transfer contribution.

Impact of the Aerodynamic Characteristics of Twin Buildings on Wind Responses (트윈 빌딩의 공력 특성이 풍응답에 미치는 영향 평가)

  • Kim, Bub-Ryur
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.33 no.1
    • /
    • pp.1-7
    • /
    • 2020
  • The wind responses of twin buildings are determined by the characteristics of wind loads and the dynamic characteristics of the structural systems of the buildings. In this study, the characteristics of wind pressure that influence wind responses were identified for two different spacings between the twin buildings using a wind tunnel test and the proper orthogonal decomposition (POD) method. Structural dynamic characteristics were also identified using 3D structural system modeling. The double modal transformation method was utilized to evaluate the characteristics of wind pressure for across-wind and along-wind conditions and the effect of the dynamic characteristics of each structure on the wind responses. The channeling and vortex effects were identified through the POD method. Across-wind loads were significantly affected by the spacings between the twin buildings, whereas along-wind loads were minimally affected. Similarly, while using the double modal transformation method, a significant difference was noticed in case of the cross-participation coefficients in the across-wind direction condition for the different spacings between the buildings; however, the along-wind direction condition showed negligible difference. Therefore, the spacing between the two buildings plays a more important role in across-wind responses compared to along-wind responses.

A Study of Adsorption Characteristics of Uranium ion Using Amidoximated PP-g-AN Fibrous ion-exchanger in Brine Water (AOPP-g-AN 섬유이온교환체를 이용한 간수로부터 우라늄 이온 흡착특성에 관한 연구)

  • 황택성;최재은;이재천
    • Polymer(Korea)
    • /
    • v.26 no.1
    • /
    • pp.121-127
    • /
    • 2002
  • We investigated uranium adsorption and adsorption process characteristics in brine water, changing column bed height packed with amidoximated polypropylene-g- acrylonitrile (AOPP-g-AN) fibrous ion-exchanger. Swelling ratios of AOPP-g-AN in fibrous ion-exchanger were 8.54g/g $H_2O_2$ and 8.87 g/g for $H_2O_2$ solvent respectively. Ion exchange capacity increased with degree of graft and showed the maximum, 3.99 meq/g at 100% degree of graft. In batch process, uranium adsorption had reached an initial equilibrium in 10 min with the adsorption rate of 9.5 mg/min. Finial adsorption capacity was 3.95 meq/g, and pH effect could not be observed. In continuous process, adsorption capacity depended on various packing ratios and showed the maximum, 3.92 meq/g at L/D=1. In L/D<2, breakthrough curve was shown two step by channeling flow and ununiform adsorption. Breakthrough time and adsorption capacity were 26 min and 3.63 meq/g, respectively, in brine water adsorption. When compared with actual brine water and model solution, there was no significant difference of adsorption characteristics.

Simulation study of ion-implanted 4H-SiC p-n diodes (이온주입 공정을 이용한 4H-SiC p-n diode에 관한 시뮬레이션 연구)

  • Lee, Jae-Sang;Bahng, Wook;Kim, Sang-Cheol;Kim, Nam-Kyun;Koo, Sang-Mo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.131-131
    • /
    • 2008
  • Silicon carbide (SiC) has attracted significant attention for high frequency, high temperature and high power devices due to its superior properties such as the large band gap, high breakdown electric field, high saturation velocity and high thermal conductivity. We performed Al ion implantation processes on n-type 4H-SiC substrate using a SILVACO ATHENA numerical simulator. The ion implantation model used a Monte-Carlo method. We studied the effect of channeling by Al implantation simulation in both 0 off-axis and 8 off-axis n-type 4H-SiC substrate. We have investigated the Al distribution in 4H-SiC through the variation of the implantation energies and the corresponding ratio of the doses. The implantation energies controlled 40, 60, 80, 100 and 120 keV and the implantation doses varied from $2\times10^{14}$ to $1\times10^{15}cm^{-2}$. In the simulation results, the Al ion distribution was deeper as increasing implantation energy and the doping level increased as increasing implantation doses. After the post-implantation annealing, the electrical properties of Al-implanted p-n junction diode were investigated by SILV ACO ATLAS numerical simulator.

  • PDF

Assessment of Potential Utility of Subcritical Water for Remediation of Crude Oil Contaminated Soil (원유오염토양의 아임계수를 통한 정화 가능성 평가)

  • Jeong, Yeon-Jae;Jo, Young-Tae;Islam, Mohammad Nazrul;Park, Seong-Jae;Jung, Sun-Kook;Park, Jeong-Hun
    • Journal of Soil and Groundwater Environment
    • /
    • v.22 no.6
    • /
    • pp.48-56
    • /
    • 2017
  • Although various methods have been investigated for treatment of crude oil contaminated soil, more researches are still required to preserve soil environment. This study investigated the potential utility of subcritical water in remediation of crude oil contaminated soil under various experimental conditions including temperature ($150-300^{\circ}C$), flow rate (1.0-2.0 mL/min) and extraction time (60-120 min). The removal rate of crude oil gradually increased with increasing temperature and time. After treatment at $200^{\circ}C$ and $300^{\circ}C$ for 60 min, the remaining concentration of crude oil met the Kuwait standard clean-up level (10,000 mg/kg) and the Korean standard level (2,000 mg/kg), respectively. The removal efficiency of crude oil increased from 77.8% to 88.4% with increasing extraction time from 60 to 120 min at $250^{\circ}C$. A decreasing rate of oil removal was observed as flow rate increased, possibly due to channeling flow occurred within the soil body at higher flow rate condition. Overall, the results revealed that subcritical water extraction process could be feasible for remediation of crude oil contaminated soil, and the relative effect of parameters on the oil removal was in the order of temperature > time > flow rate.

A Study on the Flux and Heat Transfer of Direct Contact Type Module Applied for a Pilot Scale Membrane Distillation Process (파일럿 규모 막 증발 공정 적용을 위한 직접 접촉식 모듈의 투과유속 및 열에너지 이동에 관한 연구)

  • Kim, Seung Hwan;Kim, Se Woon;Lee, Dong Woo;Cho, Jin Woo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.3
    • /
    • pp.229-236
    • /
    • 2017
  • In this study, a direct contact membrane module was manufactured to be used in a pilot scale membrane distillation process to treat $3m^3/day$ of the digestate produced from anaerobic digestion of livestock manure. In order to investigate the performance of the membrane module, permeate flux was measured with and without spacer inside the module under various condition of temperature difference and cross flow velocity (CFV) through the membrane surfaces. Flux recovery rate after chemical cleaning was also investigated by applying three different cleaning methods. Additionally, thermal energy consumption was theoretically simulated based on actual pilot plant operation conditions. As results, we observed flux of the module with spacer was almost similar to the theoretically predicted value because the installation of spacer reduced the channeling effect inside the module. Under the same operating condition, the permeate flux also increased with increasing temperature difference and CFV. As a result of chemical in-line cleaning using NaOCl and citric acid for the fouled membranes, the recovery rate was 83.7% compared to the initial flux when NaOCl was used alone, and 87% recovery rate was observed when only citric acid was used. However, in the case of using only citric acid, the permeate flux was decreased at a rapid rate. It seemed that a cleaning by NaOCl was more effective to recover the flux of membrane contaminated by the organic matter as compared to a cleaning by citric acid. The total heat energy consumption increased with increasing CFV and temperature difference across the membrane. Thus, further studies should be intensively conducted to obtain a high permeate flux while keeping the energy consumption to a minimum for a practical application of membrane distillation process to treat wastewater.

Evaluating Wind Load and Wind-induced Response of a Twin Building using Proper Orthogonal Decomposition (트윈 빌딩의 적합 직교 분해 기법을 이용한 풍하중 및 풍응답 평가)

  • Kim, Bub-Ryur
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.31 no.6
    • /
    • pp.309-314
    • /
    • 2018
  • The wind load and structural characteristics of a twin building are more complex than those of conventional high-rise buildings. The pressure load due to wind on a twin building was therefore measured via wind tunnel experiments to analyze such characteristics. The wind pressure pattern was then deduced from measured data using proper orthogonal decomposition. Channeling and vortex shedding were observed in the first and second modes, respectively. The along-wind loads on the two buildings featured a positive correlation and the cross-wind loads featured no correlation. Such a correlation affected the wind-induced displacement. The structural member connecting the two buildings had an insignificant effect on the positive correlation, but it notably reduced the wind-induced displacement with a negative correlation.