• Title/Summary/Keyword: chamber width

Search Result 158, Processing Time 0.027 seconds

Effects of Plant Growth Regulators on Seed Germination and Seedling Growth of Mountain Mulberry Seeds (Morus bombycis Koidz) (식물생장조절물질이 산뽕나무 종자의 발아 및 유묘생장에 미치는 영향)

  • Song, Min-Jeong;Kim, Kyung-Hoon;Hur, Young-Jin
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.19 no.1
    • /
    • pp.101-109
    • /
    • 2016
  • This is the fundamental research on restoring damaged vegetation areas in the vicinity of DMZ using local native plant species. This research is aimed at identifying effective plant growth regulators (PGR) for seed germination and seedling growth of mountain mulberry, and developing effective methods for managing its germination and growth. Mountain mulberry seeds were collected from the regions in the DMZ vicinity, and tests with seven treatments using four PGRs including $GA_3$, kinetin, ABA and NAA, were conducted. The germination rate was calculated in two different ways of both in a growth chamber and in a greenhouse after seven days observation, and the growth characters such as leaf width/length, seedling width/length and fresh/dry weight, have been surveyed in a greenhouse for three months. Although in the growth chamber the highest germination rate was shown at a group with the kinetin treatment, it was not significantly different to that of the control group. Groups with ABA or NAA presented relatively low germination rates. As for the greenhouse test, the germination rates of all groups ranged 20~30% without significant difference each other, the reason of which might be due to low absorption by the effect of a soil drench method used in this study. The entire growth characters with the treatments of $2.15mg{\cdot}L^{-1}$ of kinetin and $10mg{\cdot}L^{-1}$ of $GA_3$ were significantly different to the control. NAA treatment only showed better growth of seedling width compared to the control. Consequently, the most effective PGRs for the germination and growth of mountain mulberry near the DMZ was kinetin. Further research on examining the most effective concentration of them was needed.

A Study On The Gas-Flow In the Four-Stroke Engine At Compression Stroke (사행정기관의 압축행정시의 가스유동에 관한 연구)

  • 이기명
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.17 no.4
    • /
    • pp.3970-3979
    • /
    • 1975
  • On account of the development of the high speed internal combustion engines, several methods for increasing burning velocity has been investigated lately. Installation of a squash area on a cylinder head is one of the simple and practical method to induce the strong tubulant flow of air-fuel mixtureinto a combustion chamber. In this study, a four-stroke engine used for agricultural purpose was tested as an experimental model. A mathematical model of the squash velocity was derived, and also, several characteristics of the squash phenomena during the motoring of the engine used as a modelwere investigated. The results obtained were as follows: (1) Mathematical model of squash velocity was established and cheked (2) Squaash velocity and engine speed were found to be proportional to the squash area while they were inversely proportional to the squash width. (3) Squash velocity and crank angle at which the squash velocity become its peak were influenced by the magnitude of squash clearance: increase of squash clearance made squash velocity reduced acd made the peak of the squash velocity for from the top dead center and (4) When the squash area is divided in small areas baving unit width along the squash section, squash velocity at each unit width was proportional to the magnitude of the squash distance covered by the unit width.

  • PDF

An Experimental Investigation for Hydraulic Characteristics of Solid and Perforated-wall Caissons of a Mixed Type Breakwater (혼성방파제의 무공 및 유공 케이슨의 수리특성에 관한 실험)

  • 서경덕;오영민;전인식;이달수
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.4 no.4
    • /
    • pp.243-249
    • /
    • 1992
  • Hydraulic experiments were carried out to investigate the hydraulic characteristics of solid and perforated-wall caissons of a mixed type breakwater for regular waves of various heights and periods. It was found that a perforated-wall caisson is more advantageous than a solid caisson for such hydraulic characteristics as reflection. transmission, and runup at the front face of the caissons and that the experimental results agree reasonably well with existing theoretical or empirical relationships. Especially the reflection coefficient of a perforated-wall caisson. mainly governed by the resonance in the wave chamber, was found to be minimum when the width of the wave chamber is approximately a quarter of the wave length in the wave chamber.

  • PDF

The Micro-Actuator Development of using the Bubble (기포를 이용한 마이크로 액츄에이터 개발)

  • 최종필;반준호;전병희;장인배;김헌영;김병희
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2003.10a
    • /
    • pp.381-385
    • /
    • 2003
  • This paper presents the fabrication possibility of the micro actuator which uses a micro-thermal bubble, generated by a micro-heater under pulse heating. The micro-actuator is consist of three plate. The lower plate includes the channel and chamber are fabricated on high processability silicon wafer by the DRIE(Deep Reactive ion Etching) process. The middle plate includes the chamber and diaphragm, and the upper plate is the micro-heater. The micro-heater designed non-uniform width and results in periodic generation of stable single bubbles in D.I water. The single bubble appears precisely on the narrow part of the micro-heater and control is recorded.

  • PDF

A Study on the Behaviour of Ultra-High Pressure Diesel Spray by Electronic Hydraulic Fuel Injection System(II) (전자유압식 분사계에 의한 초고압 디젤분무의 거동에 관한 연구(II))

  • 장세호;안수길
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.5
    • /
    • pp.182-190
    • /
    • 1998
  • Behaviour of ultra-high pressure diesel spray in a constant-volume pressure chamber was studied with injection pressure ranging from 20 to 160㎫. Sprays were observed by the right angle scattering method. As a result, the spray tip penetration is first proportional to a time, and after that, it is proportional to 0.52 of the time during at the time of injection pressure and back pressure increase. An empirical correlation was made for the parameters of injection pressure, air-fuel density ratio, spray tip distance, spray angle, jet angle of spray and max. spray width.

  • PDF

Wave Reflection from Partially Perforated Wall Caisson Breakwater

  • K. D. Suh;Park, W. S.;Lee, D. S.
    • Proceedings of the Korean Society of Coastal and Ocean Engineers Conference
    • /
    • 1996.10a
    • /
    • pp.176-183
    • /
    • 1996
  • In order to reduce wave reflection from a breakwater, a perforated wall caisson is often used. A conventional perforated wall caisson breakwater for which the water depth inside the wave chamber is the same as that on the rubble mound berm has less weight than a vertical solid caisson with the same width and moreover the weight is concentrated on the rear side of the caisson. (omitted)

  • PDF

An experimental study on the liquid rocket combustion chamber cooling (액체로켓 연소실 냉각에 관한 실험적 연구)

  • Kim, B.H.;Park, H.H.;Jeong, Y.G.;Kim, Y.
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.5 no.2
    • /
    • pp.1-7
    • /
    • 2001
  • To protect combustion chamber from high temperature combustion gas, regenerative cooling is used for most liquid rocket engine. Although regenerative cooling is the most effective way to protect the chamber from high heat flux, realization of this system requires detail analysis, manufacturing technique and high cost. To demonstrate the possibility of applying regenerative cooling to a real rocket engine, the hot fire test has been carried out for the sub-scale liquid rocket with the water cooling system. The main purpose of the test is to identify the problem area of design, safety and cost effective manufacturing technique. The coolant passage was 3 mm in width and wall thickness was 1 mm with stainless steel. Maximum combustion time and pressure were 60 seconds and 400 psi, respectively. The flow rate of coolant was reduced gradually from 2 kg/s to 0.12 kg/s throughout firing test, combustion chamber was visually examined and no dwfect was observed.

  • PDF

Estimation of Optimal Slit Length of Perforated Wall below Still Water Level: Single Chamber Condition (정수면 아래 최적 유공부 길이 산정 : 유공 1실 조건)

  • Kim, Young Taek;Lee, Jong In
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.4
    • /
    • pp.327-334
    • /
    • 2013
  • In this study, the optimal slit length of perforated wall with single chamber below the still water level (SWL) is studied through the two dimensional test. The relationship between the reflection coefficient and the shape of structures such as chamber width(B) and slit length(S) are investigated by applying the various wave conditions. The random waves were used for the test by using Bretschneider-Mitsuyasu frequency spectrum. Minimum reflection coefficient is obtained at $B/L_s{\approx}0.15$ condition, this result is different from the regular wave condition. Also the minimum reflection coefficients are measured at $S/H_s{\approx}2.5$. This means that the optimal slit length below the still water level is 2.5 times of the incident wave height.

Characteristic as a Resonance Frequency of $SF_6$ Gas (SF6 가스중의 공진주파수에 따른 신호특성)

  • Lee, Y.H.;Lee, H.D.;Park, J.N.;Shin, Y.S.;Park, J.S.;Seo, J.M.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1867-1869
    • /
    • 2003
  • In this paper, chamber(Circuit breaker compartment of C-GIS) made of stainless steel with 4 mm width is used. Artificial defect was made on enclosure or HV conductor of chamber and $SF_6$ gas was injected into it according to pressure. In this experiment, Acoustic emission sensors of different types was used to compare sensitivity to detect acoustic signal occurred by Partial discharge(PD) of according to types and resonance frequency in $SF_6$ gas atmosphere. Sensors used in tests was R6I, R15I and 2/4/6 Pre-Amplifier connected with R6IU without pre. amp. In case of R6IU, gain was adjusted with 40 dB like other sensors and operated by differential mode. Post amplifier(post. amp) and band pass filter(BPF) were developed Gain of post. amp. is 60 dB and BPF has band width of $50{\sim}300$ kHz. Also, envelope circuit developed reduces frequency of AE sensor. As a result, in $SF_6$ atmosphere, R6IU and R6I had resonance frequency of 60 Hz was better than R15I. Also, R6IU was better than R6I because of type property of pre.amp. had differential mode.

  • PDF

A Study on the Representations of an Bell Chamber in Namhansansung (남한산성 종(鐘)과 종각(鐘閣) 복원을 위한 연구)

  • Lee, Jin-Hyang;Kim, Dae-Ho;Lee, Jae-Keun
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.28 no.4
    • /
    • pp.120-126
    • /
    • 2010
  • As the importance of an historical area is getting increased in these days, the reconstruction of an bell chamber in Namhansansung has significant historial, educational and cultural meaning. The purpose of this study, as a study on an bell chamber in Namhansansung, is to assume an original location of the bell chamber and identify the size and shape of the original bell chamber through literature study, site inspection, and analysis on old maps. In addition, this study could provide useful information when new bell chamber is constructed. According to the literature study, site inspections(5 times) and analysis on old maps, the original bell chamber is assumed to locate near current Oroji tea house at the rotary, where was in the area of Hanggung. With regard to the traffic system, it is assume that there was an old road along with the current local road No.342 connecting the South Gate with North Gate and a Y or T shape intersection connecting the site of old bell chamber with the north. In addition, there was a government office street from the old bell chamber to Hanggung. The shape of old bell chamber is assumed to have Paljak or Woojingak roof. Samo roof was not found in all the five maps. Regarding the direction of bell chamber, three maps indicate that it faces the East and two maps show that it faces the South. Therefore, it is assumed that the length and width of the roof have similar size. However, a new bell chamber should face the East, which is the same direction with Hanggung. As there is a record which states that a bell in the Cheonheoungsa, Seonggeosan, Cheonan was used as a Namhansansung's bell when the Cheonheoungsa was closed, this study suggests that new Namansansung's bell should be built, considering histroical value and artistry of Cheonheoungsa's bell. This study is a basic research for the reconstruction of Namhansansung in 2009. However, as reconstruction of historical assets should be based on thorough historical evidences. Therefore, more detail researches by a indicator analysis are left for the topic of future studies.