An Experimental Investigation for Hydraulic Characteristics of Solid and Perforated-wall Caissons of a Mixed Type Breakwater

혼성방파제의 무공 및 유공 케이슨의 수리특성에 관한 실험

  • 서경덕 (한국해양연구소 해양공학연구실) ;
  • 오영민 (한국해양연구소 해양공학연구실) ;
  • 전인식 (한국해양연구소 해양공학연구실) ;
  • 이달수 (한국해양연구소 해양공학연구실)
  • Published : 1992.12.01

Abstract

Hydraulic experiments were carried out to investigate the hydraulic characteristics of solid and perforated-wall caissons of a mixed type breakwater for regular waves of various heights and periods. It was found that a perforated-wall caisson is more advantageous than a solid caisson for such hydraulic characteristics as reflection. transmission, and runup at the front face of the caissons and that the experimental results agree reasonably well with existing theoretical or empirical relationships. Especially the reflection coefficient of a perforated-wall caisson. mainly governed by the resonance in the wave chamber, was found to be minimum when the width of the wave chamber is approximately a quarter of the wave length in the wave chamber.

혼성방파제의 무공 및 유공 케이슨의 수리특성을 비교하기 위하여 파고 및 주기가 다른 여러 규칙파를 대상으로 수리실험을 실시하였다. 반사율, 전달률, 케이슨 전면에서의 쳐올림 높이 등 수리특성 면에서 모두 유공케이슨이 무공케이슨보다 유리한 것으로 나타났으며, 본 실험 결과가 기존의 이론식 또는 경험식들과 대체로 잘 일치함을 보였다. 특히, 유공케이슨의 반사율은 유수실 내에서의 공진현상과 밀접한 관계가 있어서 유수실의 폭이 유수실 내에서의 파장의 약 1/4 정도가 될 때 반사율이 최소가 됨을 알 수 있었다.