• 제목/요약/키워드: chamber type

검색결과 1,052건 처리시간 0.027초

철도 차량 정비 작업자를 위한 일회용 부직포 작업복의 온열적 성능 평가 (Evaluation of the Thermal Properties of Disposable Coveralls for Railroad Carriage Maintenance Workers)

  • 최정화;이주영;김소영
    • 한국의류학회지
    • /
    • 제28권8호
    • /
    • pp.1175-1185
    • /
    • 2004
  • This study evaluated thermo-physiological and subjective properties of improved disposable coveralls for railroad carriage maintenance through climatic chamber trials and a filed study. Subjects wore five kinds of disposable coveralls (Type A: a disposable coverall on the market, Type B: a coverall with an improved hood and size-adjustable design, Type C: a coverall with a portable hood, Type D: a coverall with small holes for ventilation, Type E: a sleeveless coverall, Type F: a separated type of coverall with half sleeves) The air temperature in the climatic chamber was set in 9$^{\circ}C$ and 30$^{\circ}C$ For each condition, subjects simulated the railroad work for 120min. and rectal temperature, skin temperatures, clothing microclimate and subjective sensations were measured. The results of chamber trials showed rectal temperature and clothing microclimate did not display significant differences by clothing type. In 30$^{\circ}C$ air temperature, mean skin temperature was higher in Type E and Type F than in Type A(p<0.05) but between the improved coveralls(B-F), we could not find any significant difference. In the case of thermal comfort, the most preferred types were Type B and Type C in 9$^{\circ}C$ and Type F in 30$^{\circ}C$. All subjects felt more comfortable in the improved coveralls than in coveralls of the market (Type A). In field study, workers preferred Type B, Type C and Type F to Type A but the most favorite type differed by the specific type of work. Especially, workers were dissatisfied that Type D tore easily due to lots of small holes around the armpits and Type I did not protect workers' shoulder and arms from oil contamination. According to the climatic chamber trials and field study, the most effective coveralls were Type B and Type C for winter and Type F for summer.

미나리 작업자를 위한 작업복 개발에 관한 연구 (Development the protective clothing for a dropworts cropping workers)

  • 최정화;백윤정
    • 한국의류학회지
    • /
    • 제24권8호
    • /
    • pp.1266-1275
    • /
    • 2000
  • This study was to research the actual condition of a dropworts working environment and to develope the clothing to reduce the work road. The actual conditions of working environment, working position and clothing were surveyed. Experiments were performed in the chamber and in the field. In the chamber, rectal temperature, 11 points skin temperatures(forehead, chest, abdomen, upperarm, forearm, dorsum manus, palm, thigh, calf, dorsum pedis and pelma), heart rates, microclimates inside clothing on the chest and subjective sensations were measured for comparing between 2 different types o garments. In the field, rectal temperature, abodomen skin temperature, 3 points microclimates inside clothing(chest, back and thigh), heart rates, the volume of EMG and subjective sensations were measured. The results were as follows; 1. There were no significant differences in rectal temperature between a old type protective clothing and a new type both in the chamber and the field. 2. Subjects wearing a old type clothing responded \"a little cold\", \"a little uncomfortable\" and subjects wearing a new type protective clothing responded \"normal\", \"comfortable\" both in the chamber and the field. 3. In the field test results, abodemen skin temperature in a old type clothing was higher and microtemperatures inside clothing of chest, back and thigh in a new type protective clothing were higher. 4. The volume of EMG was lower in the new type protective clothing than in the old one.protective clothing than in the old one.

  • PDF

공기챔버 위치에 따른 폰툰형 초대형 구조물 유탄성응답 해석 (Hydroelastic Analysis of Pontoon Type VLFS Considering the Location and Shape of OWC Chamber)

  • 홍사영;경조현;김병완
    • 한국해양공학회지
    • /
    • 제22권1호
    • /
    • pp.22-29
    • /
    • 2008
  • A numerical investigation is made on the effects of the location and shape of the front wall of an OWC(Oscillating Water Column) chamber on the hydroelastic response of a VLFS. Most of the studies on the effects of an OWC chamber on the response of a VLFS have assumed the location of the OWC chamber to be at the front of the VLFS. In the present study, an OWC-chamber is introduced at an arbitrary position in relation to a VLFS to determine the influence of the location and shape of the OWC chamber on the hydroelastic response of the VLFS. A finite element method is adopted as a numerical scheme for the fluid domain. or the finite element method, combined with a mode superposition method, is applied in order to consider the change of mass and stiffness The OWC chamber in a piecewise constant manner. or the facilitated anefficient analysis of The hydroelastic response of the VLFS, as well as the easy modeling of different shape and material properties for the structure. Reduction of hydroelastic response of the VLFS is investigated for various locations and front wall shapes of the owe chamber.

스파크 점화기관의 연소실 형상에 따른 공진현상 해석에 관한 연구 (A Study on the Presure Resonance with Combustion Chamber Geometry for a Spark Ignition Engine)

  • 박경석;장석형
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.890-895
    • /
    • 2001
  • Pressure resonance frequency that is caused in the combustion chamber can be interpreted to acoustic analysis. Until now the pressure resonance has been assumed and calculated to a disc type combustion chamber that neglected the combustion chamber height because the knock occurs near the TDC(top dead center). In this research FEM(fine element method) has been used to calculate the pressure resonance frequency inside the experimental engine combustion. The reduce error of the resonance frequency obtained by FEM has decreased about 50% compared to the calculation of Draper's equation. Due to the asymmetry in the shape of the combustion chamber that was neglected in Draper's equation we could find out that a new resonance frequency could be generated. To make the experimental results equal we could know that the speed of sound that satisfies Draper's equation was selected 13% higher than all the pent-roof type combustion considered.

  • PDF

Analysis of the experimental cooling performance of a high-power light-emitting diode package with a modified crevice-type vapor chamber heat pipe

  • Kim, Jong-Soo;Bae, Jae-Young;Kim, Eun-Pil
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제39권8호
    • /
    • pp.801-806
    • /
    • 2015
  • The experimental analysis of a crevice-type vapor chamber heat pipe (CVCHP) is investigated. The heat source of the CVCHP is a high-power light-emitting diode (LED). The CVCHP, which exhibits a bubble pumping effect, is used for heat dissipation in a high-heat-flux system. The working fluid is R-141b, and its charging ratio was set at 60 vol.% of the vapor chamber in a heat pipe. The total thermal conductivity of the falling-liquid-film-type model, which was a modified model, was 24% larger than that of the conventional model in the LED package. Flow visualization results indicated that bubbles grew larger as they combined. These combined bubbles pushed the working fluid to the top, partially wetting the heat-transfer area. The thermal resistance between the vapor chamber and tube in the modified design decreased by approximately 32%. The overall results demonstrated the better heat dissipation upon cooling of the high-power LED package.

고선량률(HDR) 근접치료의 동위원소 Ir-192에 대한 측정방법에 관한 고찰 (A Study on Calibration Procedures for Ir-192 High Dose Rate Brachytherapy Sources)

  • 백태성;이승욱;나수경
    • 대한방사선치료학회지
    • /
    • 제19권1호
    • /
    • pp.19-26
    • /
    • 2007
  • 목 적: Ir-192 고선량율 근접치료(HDR Brachytherapy)선원에 대한 다양한 측정절차의 효율을 서로 비교할 것이며, 측정 장비의 추가 구입 없이 대안으로 새롭게 만든 PMMA (polymethylmethacrylateplastics: $C_5H_8O_2$) plate phantom에 대한임상에서의 적합성과 유용성을 알아 보았다. 대상 및 방법: 세 가지 형태(Well type chamber, Source calibration jig, PMMA plate phantom)의 측정 시스템을 이용하여 측정값을 비교하였다. Source calibration jig와 PMMA plate phantom을 사용 했을 때에는 Farmer type chamber를 이용하여 측정하였으며, 각각 5회씩 측정하여 제조업체의 측정치와 비교하였다. 또한 새로운 선원을 교환 할 때마다 제조업체로부터 선원과 함께 제공되는 제조업체의 측정치를 본 연구의 측정치와 비교하여 방사능의 정확도를 평가 하였다. 결 과: Well type chamber, Source calibration jig, PMMA plate phantom를 사용한 Ir-192 선원의 측정결과 제조업체 측정치와의 상대오차에 대한 RMS (Root Mean Square)값은 Well type chamber에서 0.6%, Source calibration jig에서 1.57%, PMMA plate phantom에서는 2.1%를 나타내었다. 또한 평균 오차에 대한 편차는 Well type chamber에서 $-0.2{\pm}0.5%$, Source calibration jig에서 $0.97{\pm}1.23%$, PMMA plate phantom에서는 $-0.89{\pm}1.87%$를 나타내었다. 결 론: 본 연구를 통해 실험한 세 가지 형태(Well type chamber, Source calibration jig, PMMA plate phantom)의 측정 시스템의 결과에서 나타난 것처럼, Well type chamber를 이용한 측정결과가 가장 우수하게 나타났다. 또한 측정 장비를 구입하지 않고 대안으로 새롭게 만든 PMMA plate phantom의 결과 권고안 ${\pm}5%$를 초과하지 않으므로 임상에서 유용하게 사용 할 수 있을 것이라 생각되어진다.

  • PDF

Changes in ruminal fermentable characteristics and nutrient degradabilities of corn flake according to chamber type in Hanwoo: chamber type for corn flake in the rumen of Hanwoo

  • Ahn, Jun-Sang;Shin, Jong-Suh;Chung, Ki-Yong;Lim, Hwan;Choi, Jang-Gun;Kim, Ji-Hyung;Kwon, Eung-Gi;Park, Byung-Ki
    • 농업과학연구
    • /
    • 제45권4호
    • /
    • pp.695-706
    • /
    • 2018
  • This study was conducted to investigate the effect of a steam chamber type on the ruminal fermentable characteristics and nutrient degradabilities of corn flakes in Hanwoo. Three Hanwoo equipped with a ruminal fistula were used as experimental animals. There were two treatments: Corn flake using a steam chamber (CFSC, 1.0 atm - $100^{\circ}C$ 96 min) or corn flake using a pressurized steam chamber (CFPSC, 1.5 atm - $111^{\circ}C$ 12 min), respectively. In the in vitro trial, the ruminal pH was significantly lower in the CFPSC than in the CFSC (p < 0.01). The ammonia concentration was increased by 14.1% in the CFPSC compared to the CFSC (p < 0.05). The concentration of acetic acid was higher in the CFSC than in the CFPSC (p < 0.01). The concentrations of propionate, butyrate and total-VFA at 24 and 48 h were higher in the CFPSC than in the CFSC (p < 0.05). In the in situ trial, the degradability of dry matter was significantly higher in the CFSC than in the CFSC (p < 0.01). In addition, the degradabilities of starch and crude protein were significantly higher in the CFSC than in the CFSC (p < 0.01). Thus, the present results indicate that the pressurized steam chamber could be recommended to improve the feed value of corn flake according to the increase in the starch degradability and volatile fatty acid production.

내장형 무선 카메라를 이용한 In-Line type 스퍼터링 시스템 내부의 실시간 모니터링 (Real time monitoring of In-Line type sputtering system using an in-vacuo wireless camera)

  • 최지성;도우리;홍광기;주정훈
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2009년도 추계학술대회 초록집
    • /
    • pp.243-244
    • /
    • 2009
  • 진공 chamber 내부 plasma를 외부에서 view port를 통한 확인 및 촬영보다 효율을 높이기 위하여 chamber 내부에 무선 camera (IVC : internal vacuum camera)를 삽입하여 더 세밀하게 plasma를 촬영하였고 view port로 확인이 불가능한 부분을 촬영 및 녹화하였다. 외부 view port로 확인할 수 없는 원거리 플라즈마 소스 (remote plasma source, RPS)와 in-line type의 chamber에서 동적 (dynamic) 증착이 이루어지는 substrate에 camera를 부착하여 이동 중 target 위쪽에 방전된 plasma, ICP (inductively coupled plasma) antenna를 진공 중 chamber 내부에서 촬영 및 녹화하였다.

  • PDF

음향 챔버형 마이크로폰 검교정기의 검교정 주파수 한계와 모드 특성을 이용한 개선 방법에 관한 연구 (A study on calibration frequency limit of acoustic chamber type microphone calibrator and improvement method using mode shape)

  • 김차영;신금재;문원규
    • 한국음향학회지
    • /
    • 제41권1호
    • /
    • pp.1-8
    • /
    • 2022
  • 본 논문은 마이크로폰 검교정을 위한 음향 챔버형 검교정기의 고주파 검교정 한계가 나타나는 원인을 밝히고 이를 향상시키는 방법을 제시한다. 상용 유한요소 해석 프로그램을 활용하여 고유 주파수 해석과 주파수 영역 해석을 통해 음향 챔버형 검교정기의 검교정 주파수 한계를 분석하였고, 이를 바탕으로 약 2 Hz 부터 6.4 kHz 까지 1 dB 수준 이내로 정교하게 검교정할 수 있는 음향 챔버형 검교정기를 설계 및 제작하고 실험을 통해 그 성능을 검증하였다. 본 연구를 통해 제안된 음향 챔버형 검교정기는 넓은 주파수 범위에서 다수의 마이크로폰을 동시에 검교정 할 수 있는 이점을 가지고 있어 다수의 마이크로폰을 위한 간편한 검교정에 유용하게 사용될 수 있다.

직접분사식 2행정 디젤기관의 연소실 형상에 따른 화염 특성 -소기압력 및 소기온도의 영향을 중심으로- (The Flame Characteristics by Combustion Chamber Shape in 2 Stroke D.I. Diesel Engine -The Influence of Scavenging Pressure and Scavenging Temperature-)

  • 최익수;방중철
    • 한국자동차공학회논문집
    • /
    • 제11권1호
    • /
    • pp.55-63
    • /
    • 2003
  • In a diesel engine, air-fuel mixture formation and ignition delay period have great influence on the performance of engine. Their main factors are combustion chamber shape, fuel injection system. air volume, air flow and so on. So, the combustion process in the cylinder is complex because of many factors which have direct and indirect effects on it. In this study, we take into consideration of scavenging pressure and scavenging temperature that are hewn as the main factor to the combustion process of two-stroke D.1. diesel engine. It is taken a picture of the combustion flame process for combustion chamber of re-entrant type and cylindrical type. So, it is applied to the basis data of combustion chamber design from an image analysis.