• Title/Summary/Keyword: chamber sensitivity

Search Result 153, Processing Time 0.029 seconds

Embryotoxicity of Bisphenol A in Daphnia magna (물벼룩에 있어 bisphenol A의 embryo독성)

  • Hwang Gab-Soo
    • Environmental Analysis Health and Toxicology
    • /
    • v.21 no.1 s.52
    • /
    • pp.81-86
    • /
    • 2006
  • Embryotoxicity tests were performed in Daphnia magna to assess aquatic ecotoxicity of bisphenol A, a well known industrial compound showing estrogen-like activity in vivo, and to examine their effectiveness in the toxicological assessment. The whole embryonic developmental period was classified into 6 stages and developmental abnormality was checked to evaluate the embryotoxicity. In the present study, bisphenol A showed the ability to interfere with embryonic development, suggesting its antiecdysteroidal activity. The rates of mortality, delayed development, deformity and immobility all showed good concentration-response relationship, demonstrating their possibility as useful toxicological indices in daphnid embryotoxicity tests that have been rarely performed so far. It seemed favorable to the test sensitivity that embryos are removed from maternal daphnids around 7 hr after deposition from the ovaries to the brood chamber. These results suggest that daphnid embryotoxicity tests can be one of useful tools available for the assessment of ecotoxicity of various chemicals in the aquatic environment.

Detecting Characteristics of Catalytic Combustible Gas Sensor (접촉연소식 가스 센서의 검지특성)

  • 박찬원;원창섭;유영한;안형근;한득영
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.10
    • /
    • pp.865-870
    • /
    • 2000
  • In this paper, catalytic combustible gas sensor was fabricated and tested under flammable gases such as CH$_4$and $C_4$H$_{10}$by using Pt coil as a heater and/or temperature sensing element. Fine $Al_2$O$_3$powder was used for a bead and Pt, Pd noble metal powder for a catalyst. Resistance variation of Pt wire was traced by the changes of the gas concentrations in a chamber. Output voltage was then monitored to obtain the gas concentration from the resistance variation. In this experiment, MgO was used to protect cracks in the based and TiO$_2$to increase the sensitivity of the sensors. Water glass was also added to enhance the selectivity to the combustible gases.s.

  • PDF

Combustion of Nano-scale Aluminum and Liquid Water for Pressure Sensitivity (물을 산화제로 하는 나노 알루미늄 분말 연소의 압력 민감도 실험)

  • Lee, Sang-Hyup;Lim, Ji-Hwan;Yoon, Woong-Sup
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.05a
    • /
    • pp.476-482
    • /
    • 2010
  • 알루미늄은 많은 이점에도 불구하고 표면의 높은 용융점을 가지는 산화 피막 효과로 인해 원활하게 점화와 연소 반응이 일어나지 못하는 단점이 있다. 그런데 산화피막을 제거하는 방법은 매우 복잡하며 용이하지 않으므로 본 연구에서는 연소율은 압력에 비례한다는 원리를 이용하여 접근하였다. 연소 속도의 압력에 따른 민감도를 알기 위해 압력 용기를 설계하였고 아르곤 가스를 이용하여 80nm의 알루미늄 분말과 산화제인 증류수의 혼합물을 3, 5, 10 기압의 압력 조건에 따른 연소속도의 변화를 측정하고 해외의 연구와 비교 분석하였다.

  • PDF

A Study on Unsteady Responses of Flames - Calculation of Flame Transfer Function in a Subscale Combustor (화염의 비정상 응답 특성 연구-화염 전달 함수 산출)

  • Sohn, Chae Hoon;Guillaume, Jourdain;Kim, Young Jun
    • 한국연소학회:학술대회논문집
    • /
    • 2015.12a
    • /
    • pp.107-108
    • /
    • 2015
  • The acoustic optimization of a swirl coaxial jet injector mounted upstream a combustion chamber is investigated to tackle combustion instabilities. The least damped modes are extracted with the help of the dynamic mode decomposition (DMD). The sensitivity of the heat release perturbation to the velocity perturbation for the second longitudinal mode is investigated by combining the Crocco's equation and the inhomogeneous wave equation and computing the flame transfer function (FTF). DMD and FTF results agree in terms of the optimized injector length.

  • PDF

LDL Cholesterol Testing Device using Serial Reflected Face-to-Face Mirror System

  • Choi, Min-Seong;Yoo, Jae-Chern
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.4
    • /
    • pp.296-299
    • /
    • 2013
  • A low density lipoprotein (LDL) cholesterol testing device, structured with serial reflected face-to-face mirror (SRM) allowing spectrophotometry measurements, is presented. The spectrophotometry has been employed to measure the amount of light that a sample absorbs, but it generally should have had path length longer than 10 mm to secure enough sensitivity. Such requirement of path length has often been problematic in implementing a thin type of lab on a disc (LOD). We developed the SRM system which was implemented in a detection chamber with 1.4mm thickness, providing path length longer than 10mm, and thus straightforwardly being applicable to LOD as thin as a compact disc. The experimental results show that the SRM system gives not only a much thinner design compared to the conventional spectrophotometry-based LOD but also a comparable performance to already commercialized spectrometers.

Improved Self Plasma-Optical Emission Spectroscopy for In-situ Plasma Process Monitoring (실시간 플라즈마공정 모니터링을 위한 Self Plasma-Optical Emission Spectroscopy 성능 향상)

  • Jo, Kyung Jae;Hong, Sang Jeen
    • Journal of the Semiconductor & Display Technology
    • /
    • v.16 no.2
    • /
    • pp.75-78
    • /
    • 2017
  • We reports improved monitoring performance of Self plasma-optical emission spectroscopy (SP-OES) by augmenting a by-pass tube to a conventional straight (or single) tube type self plasma reactor. SP-OES has been used as a tool for the monitoring of plasma chemistry indirectly in plasma process system. The benefits of SP-OES are low cost and easy installation, but some semiconductor industries who adopted commercialized SP-OES product experiencing less sensitivity and slow sensor response. OH out-gas chemistry monitoring was performed to have a direct comparison of a conventional single type tube and a by-pass type tube, and fluid dynamic simulation on the improved hardware design was also followed. It is observed faster pumping out of OH from the chamber in the by-pass type SP-OES.

  • PDF

Characteristic as a Resonance Frequency of $SF_6$ Gas (SF6 가스중의 공진주파수에 따른 신호특성)

  • Lee, Y.H.;Lee, H.D.;Park, J.N.;Shin, Y.S.;Park, J.S.;Seo, J.M.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1867-1869
    • /
    • 2003
  • In this paper, chamber(Circuit breaker compartment of C-GIS) made of stainless steel with 4 mm width is used. Artificial defect was made on enclosure or HV conductor of chamber and $SF_6$ gas was injected into it according to pressure. In this experiment, Acoustic emission sensors of different types was used to compare sensitivity to detect acoustic signal occurred by Partial discharge(PD) of according to types and resonance frequency in $SF_6$ gas atmosphere. Sensors used in tests was R6I, R15I and 2/4/6 Pre-Amplifier connected with R6IU without pre. amp. In case of R6IU, gain was adjusted with 40 dB like other sensors and operated by differential mode. Post amplifier(post. amp) and band pass filter(BPF) were developed Gain of post. amp. is 60 dB and BPF has band width of $50{\sim}300$ kHz. Also, envelope circuit developed reduces frequency of AE sensor. As a result, in $SF_6$ atmosphere, R6IU and R6I had resonance frequency of 60 Hz was better than R15I. Also, R6IU was better than R6I because of type property of pre.amp. had differential mode.

  • PDF

Numerical Study on Dynamic Characteristics of Pintle Nozzle for Variant Thrust: Part 2 (가변 추력용 핀틀 노즐의 동적 특성에 관한 수치적 연구: Part 2)

  • Heo, Jun-Young;Kim, Ki-Wan;Sung, Hong-Gye;Yang, June-Seo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.123-128
    • /
    • 2012
  • According to the sequence of pintle operation, the performance characteristics of pintle nozzles are analyzed. The pintle movement was simulated using unsteady numerical techniques, the response lag and sensitivity at the chamber and nozzle are estimated for movable pintle. Three operation sequences of the pintle are considered for evaluating whether the rate of the chamber pressure increase and the operation sequence will have any significant impact towards the rocket performance. Three operation sequencies are as following; the pintle moves toward the nozzle throat, it turns instantly (case 1), stops at the nozzle throat for some time(0.5sec) (case 2), and stops at the nozzle throat (case 3). As a result, the dynamic characteristics according to the operation sequence and pintle shape were analyzed to take account the rocket performance.

  • PDF

Improvement of detection sensitivity of impurities on Si wafer surface using synchrotron radiation (방사광을 이용한 Si 웨이퍼 표면불순물 검출감도 향상)

  • 김흥락;김광일;강성건;김동수;윤화식;류근걸;김영주
    • Journal of the Korean Vacuum Society
    • /
    • v.8 no.1
    • /
    • pp.13-19
    • /
    • 1999
  • Total reflection X-ray fluorescence spectroscopy using synchrotron radiation source called as TRSFA was explored to achieve high sensitivities to impurity metals on Si wafer surface. It consists of monochromating part to select a specific wavelength, slit part to shield direct beam and to control monochromated beam, and main chamber to dectect fluorescent X-ray counts of impurities on si wafer. Monochromated X-ray of 10.90 KeV was selected and the optimum total reflection condition on silicon wafer was obtained through tuning the dead time and fluorescent X-ray count of Si and Fe. TRSFA system could increase the sensitivity as high as 50 times in comparision with TRXFA using normal X-ray source. But the trend was varied since the surface conditions of Si wafers and, therefore, the reflectivities were different. Furthemore, there seems to be a promising path to reaching a detection limit useful to the next generation metal impurities control, because Fe impurity below to the $5\times10^{9}\textrm{atomas/cm}^2$ can be detectable through the developed TRSFA system.

  • PDF

Fabrication and Characterization of TFT Gas Sensor with ZnO Nanorods Grown by Hydrothermal Synthesis (수열합성법으로 성장시킨 ZnO 나노 로드기반 TFT 가스 센서 제조 및 특성평가)

  • Jeong, Jun-Kyo;Yun, Ho-Jin;Yang, Seung-Dong;Park, Jeong-Hyun;Kim, Hyo-Jin;Lee, Ga-Won
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.4
    • /
    • pp.229-234
    • /
    • 2017
  • In this study, we fabricated a TFT gas sensor with ZnO nanorods grown by hydrothermal synthesis. The suggested devices were compared with the conventional ZnO film-type TFTs in terms of the gas-response properties and the electrical transfer characteristics. The ZnO seed layer is formed by atomic-layer deposition (ALD), and the precursors for the nanorods are zinc nitrate hexahydrate ($Zn(NO_3)_2{\cdot}6H_2O$) and hexamethylenetetramine ($(CH_2)6N_4$). When 15 ppm of NO gas was supplied in a gas chamber at $150^{\circ}C$ to analyze the sensing capability of the suggested devices, the sensitivity (S) was 4.5, showing that the nanorod-type devices respond sensitively to the external environment. These results can be explained by X-ray photoelectron spectroscopy (XPS) analysis, which showed that the oxygen deficiency of ZnO nanorods is higher than that of ZnO film, and confirms that the ZnO nanorod-type TFTs are advantageous for the fabrication of high-performance gas sensors.