• Title/Summary/Keyword: chair

Search Result 948, Processing Time 0.029 seconds

The Crystal and Molecular Structure of P-Aminobenzaldehyde Cyclohexylthiosemicarbazone (P-Aminobenzaldehyde Cyclohexylthiosemicarbazone의 결정 및 분자구조)

  • Chung Hoe Koo;Chong Hee Kim;Young Ja Park
    • Journal of the Korean Chemical Society
    • /
    • v.25 no.6
    • /
    • pp.343-350
    • /
    • 1981
  • The crystal and molecular structure of P-aminobenzaldehyde cyclohexylthiosemicarbazone, C14H20N4S, has been determined from 2712 integrated intensities measured on a computer controlled four circle diffractometer with monochromated $CuK_{\alpha}$, X-ray radiation. The crystals are monoclinic, space group C2/c with eight molecules in a unit cell of dimensions, a = 12.488(2), b = 12.276(4), c = 19.997(6)${\AA}$ and ${\beta}=103.55(3)^{\circ}$. The structure was solved by Patterson and Fourier method and refined by a full-matrix least squares method to a final R value of 0.058 for all reflections. The C(8)-S bond is trans to N(2)-N(3) and C(8)-N(1) is cis to N(2)-N(3) bond. The cyclohexane ring has chair conformation and makes an angle of $40.7^{\circ}$ with the benzene ring. The molecules are linked by N(2)H…S hydrogen bonds into dimer-like units which are held together by $N-H{\ldots}N$ hydrogen bonds. Sulfur accepts second rather weak hydrogen bond from N(4). An intramolecular hydrogen bond exists between N(1) and N(3) atoms.

  • PDF

Electroencephalographic brain frequency in athletes differs during visualization of a state of rest versus a state of exercise performance: a pilot study

  • Berk, Lee;Mali, Deeti;Bains, Gurinder;Madane, Bhagwant;Bradburn, Jessica;Acharya, Ruchi;Kumar, Ranjani;Juneja, Savleen;Desai, Nikita;Lee, Jinhyun;Lohman, Everett
    • Physical Therapy Rehabilitation Science
    • /
    • v.4 no.1
    • /
    • pp.28-31
    • /
    • 2015
  • Objective: Psychomotor imagery has been widely used to improve motor performance and motor learning. Recent research suggests that during visualization, changes occur in neurophysiological networks that make physical practice more effective in configuring functional networks for skillful behaviors. The aim of our pilot study was to determine if there was change and to what extent there was differentiation in modulation in electroencephalography (EEG) frequencies between visualizing a state of rest and a state of exercise performance and to identify the preponderant frequency. Design: Quasi-experimental design uncontrolled before and after study. Methods: EEG brain wave activity was recorded from 0-40 Hz from nine cerebral cortical scalp regions F3, Fz, F4, C3, Cz, C4, P3, POz, and P4 with a wireless telemetric EEG system. The subjects, while sitting on a chair with eyes closed, were asked to visualize themselves in a state of routine rest/relaxation and after a period of time in a state of their routine exercise performance. Results: The gamma frequency, 31-40 Hz, (${\gamma}$) was the predominant wave band in differentiation between visualizing a state of rest versus visualizing a state of exercise performance. Conclusions: We suggest these preliminarily findings show the EEG electrocortical activity for athletes is differentially modulated during visualization of exercise performance in comparison to rest with a predominant ${\gamma}$ wave band frequency observed during the state of exercise. Further controlled experimental studies will be performed to elaborate these observations and delineate the significance to optimization of psychomotor exercise performance.

Research on Classification of Sitting Posture with a IMU (하나의 IMU를 이용한 앉은 자세 분류 연구)

  • Kim, Yeon-Wook;Cho, Woo-Hyeong;Jeon, Yu-Yong;Lee, Sangmin
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.11 no.3
    • /
    • pp.261-270
    • /
    • 2017
  • Bad sitting postures are known to cause for a variety of diseases or physical deformation. However, it is not easy to fit right sitting posture for long periods of time. Therefore, methods of distinguishing and inducing good sitting posture have been constantly proposed. Proposed methods were image processing, using pressure sensor attached to the chair, and using the IMU (Internal Measurement Unit). The method of using IMU has advantages of simple hardware configuration and free of various constraints in measurement. In this paper, we researched on distinguishing sitting postures with a small amount of data using just one IMU. Feature extraction method was used to find data which contribution is the least for classification. Machine learning algorithms were used to find the best position to classify and we found best machine learning algorithm. Used feature extraction method was PCA(Principal Component Analysis). Used Machine learning models were five : SVM(Support Vector Machine), KNN(K Nearest Neighbor), K-means (K-means Algorithm) GMM (Gaussian Mixture Model), and HMM (Hidden Marcov Model). As a result of research, back neck is suitable position for classification because classification rate of it was highest in every model. It was confirmed that Yaw data which is one of the IMU data has the smallest contribution to classification rate using PCA and there was no changes in classification rate after removal it. SVM, KNN are suitable for classification because their classification rate are higher than the others.

Development and Evaluation of Rollator for Elderly Farmers

  • Lee, Kyung Suk;Kim, Kyung Ran;Kim, Hyo Cher;Chae, Hye Seon;Kim, Sung Woo;Seo, Min Tae
    • Journal of the Ergonomics Society of Korea
    • /
    • v.33 no.6
    • /
    • pp.487-497
    • /
    • 2014
  • Objective: This study aims to develop and evaluate a multi-purpose rollator, which may be used as a seat, as a traditional walker, or as a storage basket for elderly farmers. Background: The rollators on the market are not user-friendly designed and seen inconvenient for elderly farmers to use, although they are sold at considerably high price. Since they lack enough space to load stuffs and are not durable or stable enough, they do not seem to be suitable for elderly farmers to use in rural areas. Method: Two types of methods were used in this study. First, the survey consisted of 19 questions was conducted among elderly farmers in rural areas, after using the developed rollator, to evaluate the usability of the rollator developed in this study. Second, EMG experiment was conducted to compare the existing rollator and developed rollator quantitatively. Through this experiment, we tried to verify the differences of muscle responses, when using the traditional and the developed ones, which have their own brake system, in the ramp. Results: The developed rollator was highly evaluated in most of the questions in the usability survey, except for the 'Weight' category in which the opinions were divided into three different types (Worse: 31%, Similar: 30%, Better: 36%). The result of EMG experiment showed that the existing rollator (7.4%MVC) demands more muscle strength than the developed rollator (5.5%MVC) does. By statistically analyzing the results of upper limb and lower limb respectively, we found out that all the muscles except deltoid in upper limb showed statistically significant differences in muscle activity when using the existing and the developed rollator. However, there was no statistical difference in lower limb muscles. Conclusion: The developed rollator in this study has maximized the functionality of the brake system, the storage and the chair, which were pointed out as the weaknesses of existing rollators. Furthermore, the developed rollator is designed to be more user-friendly, safe, durable, and effective for elderly farmers to use in rural areas, where roads are rough and bumpy. Application: We expect that the emergency brake system developed in this study would be utilized for other convenience equipment, such as strollers and carts, and that it would be able to develop and produce more secure and reliable equipment in the future.

Development of Individually Adapted Electromagnetic Therapy System in Incontinence (환자 맞춤형 전자기장 요실금 치료 시스템 개발)

  • Noh, Si-Cheol;Kang, Kyu-Hong;Lee, Jeong-Seok;Min, Kwon-Sik;Kwon, Jang-Woo;Choi, Heung-Ho
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.45 no.4
    • /
    • pp.51-59
    • /
    • 2008
  • Incontinence is the urination disorder as the leakage of urine without her own volition and the woman's representative disease which reduce the life quality. The electromagnetic therapy has high possibility of development cause it has no needs of operant exercise, no arousing of shame and impossibility of infection. But, it has improvement points such as uniformity of the treatment protocol, patient dependance and absent of patient monitoring system. With these demands, the system which stimulate the pelvic flaw muscle with electromagnetic and monitoring the patient status during the therapy is proposed, in this study. And individually adapted electromagnetic therapy system for incontinence patient is also suggested. The proposed system consisted of electromagnetic generation device, cooling device, treating chair, patient monitoring device with pulsation and control software. The simulation for high power system and evaluation confirm was performed. With the development of control software, the convenience of using and maintenance are ensured and the patient adapted therapy protocol is applied. The developed patient adapted electromagnetic therapy system with monitoring device is regarded as the patient affinitive treating method by reducing the riskiness, improving the efficiency with patterned protocol and pre/post therapy. These results, in this study, can bring the safe and organized treatment method to incontinence patients and can lead the variable study for electromagnetic therapy in incontinence.

Preliminary study on absorption characteristic of a human body according to the amount of clothing worn for developing standard test dummy (표준더미 개발을 위한 착의량에 따른 인체의 흡음특성 기초연구)

  • Kim, Yong-Hee;Lee, Sung-Chan
    • The Journal of the Acoustical Society of Korea
    • /
    • v.36 no.4
    • /
    • pp.254-260
    • /
    • 2017
  • The purpose of this study is to evaluate the sound absorption characteristics of a human body according to the amount of clothing worn by using reverberation method measurement method for developing standard test dummy, which can be used for testing absorption of occupied audience chair. Test method was based on the previous study (Conti et al., 2004), each experiment is conducted in the reverberation room and a subject wearing clothes is standing in that chamber. In this experiment, the sound absorption area of each frequency band according to the wearing of various material clothing was measured. As a result of measurements, the average sound absorption area of the whole frequency band was $0.25m^2-0.48m^2$ in case of a subject not wearing outer clothes, and $0.38m^2-0.98m^2$ in case of wearing of outerwear. Polyester tops by showing the maximum value, the highest characteristics in the 800 Hz to 1 kHz band among the rest of fiber materials. The outer jacket made of the wool and cotton materials show a higher absorption area as the frequency increases to the higher frequency band. The change of the sound absorption area according to the clothing amount was divided by the thermal resistance (clo) of the worn clothes and the weight per body surface area.

Study on the Relationship between Family Support and Functional Recovery in Cerebrovascular Accident Patients with Rehabilitation Treatment of Oriental Medicine (한방재활치료를 받은 뇌졸중 환자가 지각한 가족지지와 기능회복에 관한 연구)

  • Kim, Kwang-Joo;Lee, Hyang-Yeon
    • Journal of East-West Nursing Research
    • /
    • v.2 no.1
    • /
    • pp.22-36
    • /
    • 1997
  • Functional recovery of cerebrovascular accident (CVA) patients were studied by examining functional independence measure (FIM) to evaluate the functional state of the patients at admission to and at discharge from the hospital and its relationship with the family support. Study subjects consisted of 129 CVA patients, who were admitted and received rehabilitation treatment at K Medical Center of Oriental Medicine from August 3 to December 18, 1997. The results were as follows: 1) Total FIM score was $72.37{\pm}25.16$ at admission and $101.67{\pm}22.13$ at discharge. The difference of average score was 29.30, which was statistically significant by paired t-test. 2) The largest difference between FIM scores at admission and at clischarge was observed in items of walking and wheel-chair riding, and the smallest clifference in items of social interaction. 3) The recovery was faster with motor function than with cognitive function, because the difference of FIM scores at admission and at discharge was much larger with motor function. 4) Recovery was better in groups under age 49 than in groups above age 70. Functional recorvery was prominent especially in groups with normal sensory state and speech functions, and groups without urinary incontinence. Recovery was less significantly in patients with paraplegic patients hospitalized longer than 2 months, patients with family all the time, and patients with CVA over 11 days. 5) We could not find any relationship between functional recovery and family support. FIM scores were lower in groups of old age(r=-0.325), long stayed in hospital (r=-0.426), and long period of time after the onset of disease(r= -0.339) with a reciprocal correlation between FIM scores and these parameters. 6) Stepwise multiple regression analysis was done to evaluate factors to affect the recovery from CVA. FIM score at admission could explain 51.2 % of the functional recovery. Important factors were periods of hospitalization, state of sensory function, age, and education (listed in decreasing order of importance). In total, they could explain 64.89% of the functional recovery. These results indicate that functional recovery of CVA patients, who were admitted to oriental medicine hospital for rehabilitation treatment, could be estimated by measuring FIM scores. Recovery was significantly better at discharge from the hospital than at admission and motor function recovery rate was much faster than that of cognitive function. 2. Recommendation Based on these results, we recommend following further studies. 1) Comparative study of recovery of motor function and of sensory function would be necessary by measuring FIM scores once a week to evaluate the recovery of CVA patients. 2) It would be interesting to see whether there is any difference of functional recovery between patients treated with either western medicine or oriental medicine. 3) Psychological factors affecting the recovery of CVA patients need to be studied.

  • PDF

THE STUDY ON SHEAR BOND STRENGTHS OF VARIOUS ONE-BOTTLE DENTIN ADHESIVES (수종의 One-bottle 상아질 결합제의 전단 결합 강도에 관한 연구)

  • Oh, So-Hee;Kim, Jong-Soo;Kwon, Soon-Won
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.4
    • /
    • pp.553-565
    • /
    • 2001
  • One-bottle adhesive system was recently developed in order to simplify the clinical skills and save chair time after continuous improvements on dentin bonding agents. To test the shear bond strength of a new "one-bottle adhesive" system to bovine dentin various commercially available one-bottle adhesives(Prime & Bond $2.1^{(R)}$, One Coat $Bond^{(R)}$, Syntac $Sprint^{(R)}$, Single $Bond^{(R)}$) were included for comparison. And we observe the interfacial morphology by scanning electron microscope. The results were as follows; 1. Group II (One Coat $Bond^{(R)}$) showed higher shear bond strength than group I (Prime & Bond $2.1^{(R)}$), group III(Syntac $Sprint^{(R)}$), and group IV(Single $Bond^{(R)}$), but no statistically significant difference was founded between groups(p>.05). 2. Relating reverse-cone shape resin tags were observed in samples of all groups under SEM. We could observed hybrid layer, resin tag and many lateral branches in every group. But, we observed in group III rare lateral branched than other three groups, and discontinuous hybrid layer.

  • PDF

Barrier Free Accessibility to Trains for All

  • Rentzsch, Manfred;Seliger, Denis;Meissner, Thomas;Wessner, Claudia
    • International Journal of Railway
    • /
    • v.1 no.4
    • /
    • pp.143-148
    • /
    • 2008
  • This paper is the output of a collaborative European project concerning the barrier free accessibility for disabled persons to regional and long distance trains in Europe. Disabled people represent around 13% of the population in Europe. This is approximately 63 million people. The range of disabilities includes people with reduced mobility including wheel chair users, viewing and hearing impaired people and other forms of impairment. Improving accessibility aims at contributing to the provision of public transport services to all citizens in an equitable way. The purpose of the project was to analyse and to evaluate the existing solutions at selected European railways for all required modules at the entrance (doors, information and safety solutions), to derive a design concept, to develop a mock-up in meeting the needs of rail travellers with the above mentioned impairments and to test it with user groups. The project also aims at deriving components for the determination of standards. The EUPAX Design Mock-up test was performed to verify the advantages of the layout of the train segment including the different modules such as access area (including the access door, gaps between platform and train as well as boarding aid devices), entrance vestibule, information systems inside and outside the train, emergency facilities, toilet with all conveniences and the additional test arrangements regarding push buttons, steps and emergency equipment. For this purpose a questionnaire was developed for the assessment of the EUPAX segment and the additional test arrangements. With the help of this questionnaire it was possible to execute a quantitative and qualitative evaluation. During three test phases 67 experts and handicapped persons from 6 countries have evaluated the Industrial Design mock-up based on this questionnaire. The test group covered persons from North (Denmark) to the South (Italy) and from the West (Spain) to the Middle of Europe (Germany). This is especially important for the generalization (harmonisation) of the results for all European countries. According to COST 335 the information for people with reduced mobility should be clear, concise, accurate and timely. So that all information can be received from persons, they must be transferred on at least two of the three possible ways (acoustical, visual, tactile), a so called "2-sense-principle". Based on the results ergonomic specifications/ solutions for the ergonomic design of the access area, the acoustic, visual and tactile information and the emergency devices including the emergency communication system were developed, related to the benefiting passenger groups.

  • PDF

Design and Control of Hybrid a Powered Wheelchair for the Elderly (고령자를 위한 하이브리드형 전동 휠체어의 설계 및 제어)

  • Yoon, Tae-Su;Ann, Sung-Jo;Kim, Sang-Min;Han, Young-Bin;Kim, Jung-Yup
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.12
    • /
    • pp.1067-1076
    • /
    • 2016
  • This paper describes the development of a hybrid-powered wheelchair (HPW) for the elderly. The proposed HPW has novel mechanical and control features compared with conventional powered wheelchairs. An ergonomic back-braking mechanism was designed in order to stop the wheels easily. In terms of control features, the HPW remarkably reduces the muscle power required by combining various assistive functions, such as wheel torque assistance, friction/inertia compensation, gravity compensation, and the one-hand driving algorithm. For wheel torque assistance, strain gauges were attached to the hand-rim in order to measure the wheel torque applied by a human. Gyroscopes and an accelerometer were attached to the wheel and chair respectively for friction and inertia compensation. An inclinometer was attached for gravity compensation and the one-hand driving algorithm was included for patients who can only use one hand. The one-hand driving algorithm controls the angular velocity of the uncontrolled wheel by using a gyroscope and pressure sensors attached to the bottom of the seat. Finally, the performance of the proposed motion assisted algorithm was verified through various experiments.