• Title/Summary/Keyword: ceramic resin

Search Result 412, Processing Time 0.025 seconds

Effects of ion-exchange for NOM removal in water treatment with ceramic membranes ultrafiltration

  • Kabsch-Korbutowicz, Malgorzata;Urbanowska, Agnieszka
    • Membrane and Water Treatment
    • /
    • v.3 no.4
    • /
    • pp.211-219
    • /
    • 2012
  • To enhance the efficiency of water treatment and reduce the extent of membrane fouling, the membrane separation process is frequently preceded by other physico-chemical processes. One of them might be ion exchange. The aim of this work was to compare the efficiency of natural organic matter removal achieved with various anion-exchange resins, and to verify their potential use in water treatment prior to the ultrafiltration process involving a ceramic membrane. The use of ion exchange prior to ceramic membrane ultrafiltration enhanced final water quality. The most effective was MIEX, which removed significant amounts of the VHA, SHA and CHA fractions. Separation of uncharged fractions was poor with all the resins examined. Water pretreatment involving an ion-exchange resin failed to reduce membrane fouling, which was higher than that observed in unpretreated water. This finding is to be attributed to the uncharged NOM fractions and small resin particles that persisted in the water.

Curing Behavior by Rotation Rheometer of Acrylic High-Solid Coatings (아크릴계 하이솔리드 도료의 Rotation Rheometer에 의한 경화거동 연구)

  • Yang, In-Mo;Jung, Choong-Ho;Kim, Tae-Ok;Park, Hong-Soo;Park, Eun-Kyung
    • Journal of the Korean Applied Science and Technology
    • /
    • v.18 no.1
    • /
    • pp.40-48
    • /
    • 2001
  • Curing reaction was carried out with the acrylic resin (ACR) [n-butyl acrylate/atyrene/2-hydroxyethyl methacrylate/acetoacetoxyethyl methacrylate (AAEM)] synthesized before and a curing agent, hexamethoxymethylmelamine (HMMM). With rotational rheometer, the effect of catalysts on curing rate of acrylic resin/melamine was examined. Among the four catalysts used, p-toluene sulfonic acid showed the highest reactivity, and the optimum amount of catalyst was 0.5 phr. It was observed that in the ACR/HMMM curing reaction, gelation point was lowered with the increasing the amount of AAEM and HMMM in the ACR.

EFFECT OF SURFACE TREATMENTS OF ZIRCONIA CERAMIC ON THE BOND STRENGTH OF RESIN CEMENTS (Zirconia ceramic의 표면처리 방법이 레진시멘트의 결합강도에 미치는 영향)

  • Kim, Chang-Hun;Jeon, Young-Chan;Jeong, Chang-Mo;Lim, Jang-Seop
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.4
    • /
    • pp.386-396
    • /
    • 2004
  • Statement of problem: It is not clear how to make a stable bonding between zirconia ceramic and resin cement. And the study about surface treatment of zirconia ceramic or bonding resin cement are not enough. Purpose: To measure and compare the shear bond strength of some resin cements on zirconia ceramic after different surface treatments. Material and method: 48 ceramic discs were made of 3 ceramic materials, zirconia ceramics (Zi-Ceram), heat-pressed ceramics (IPS Empress 2) and slip cast alumina ceramics (In-Ceram). According to the surface treatments of ceramic specimens and resin cements, specimens were classified into 6 groups and each group was composed of 8 specimens. For the surface treatment of Zi-Ceram group (test group), sandblasting and diamond bur preparation were applied and Superbond C&B and Panavia F were bonded respectively. For IPS Empress 2 group (control group), Variolink II was bonded after sandblasting, acid etching, silanization and for In-Ceram ALUMINA group (control group), Panavia F was bonded after sandblasting. After storing specimens in distilled water for 24 hours, the shear bond strength was measured by the universal testing machine. Results and conclusion: 1. Zi-Ceram group with Superbond C&B cement showed higher bond strength than with Panavia F cement regardless to the surface treatments (p<0.05). 2. In Zi-Ceram group with Superbond C&B cement, sandblasting treatment group (12.1MPa) showed higher bond strength than diamond bur treatment group (7.7MPa) (p<0.05). In Zi-Ceram group with Panavia F cement, there were no significant differences in the bond strength according to the surface treatments (p>0.05). 3. Zi-Ceram group with sandblasting and Superbond C&B cement (12.1MPa) showed the highest bond strength. The bond strength of this group was not significantly different from In-Ceram ALUMINA group (10.4MPa) (p>0.05) and lower than IPS Empress 2 group (15.9MPa) (p<0.05).

A STUDY ON BlOCOMPATABILITY OF RESIN CEMENTS FOR ALL-CERAMIC CROWN (전부도재관용 레진시멘트의 생체적합성에 관한 연구)

  • Kim Kwang-Jun;Kim Sung-Hoon;Jin Tai-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.2
    • /
    • pp.111-127
    • /
    • 2003
  • Statement of problem : Resin cements were used widely on all ceramic crowns, but the influence of resin cements on biocells was not understood clearly. Purpose : This study was investigated to evaluate the biocompatibility of resin cements for all-ceramic crowns. Material and Method : The resin cements used in this study were Panavia F (Kuraray Co., Ltd. Japan), Variolink II (Vivadent Ets., Schann / Liechtenstein), and Bistite II (Bistite dual cure resin cement-clear Tokuyama Soda Co. Japan). The viability of normal human oral keratocytes, gingival fibroblast, and gingival fibroblast immortalized by Human Papilloma virus 16 was measured in vitro for evaluation of cytotoxicity on resin cements, and the response of pulp tissue was analyzed and evaluated with light microscope after application of cements at cutting edge of incisors. Results : The normal human oral keratocytes was the most sensitive to toxicity of resin cement, and toxicity of cements was higher in Bistite II than in Variolink II. The cell viability of immortalized gingival fibroblast did not affected by type of cement and cultivation period, but there was a tendency that cytotoxicity in Bistite II was higher than in Variolink II. The cell viability of gingival fibroblast was similar to that of immortalized gingival fibroblast regardless of cement type, but Bistite II showed more toxic than others after 5 days cultivation. The responses of pulp tissue according to cement type were similar after 2 days cultivation, but revealed high toxicity in Bistite II after 10 days cultivation. Conclusion : Variolink II was more biocompatible than any other resin cements used in this study.

High Pressure Curing of Phenol Resin for High Quality Coating of Glassy Carbon (고품질 유리질 카본 코팅을 위한 페놀 수지의 고압 경화)

  • Hong, Seok-Gi;Cho, Kwang-Youn;Kwon, Oh-Hyeon;Cho, Yong-Soo;Jang, Seung-Jo
    • Journal of the Korean Ceramic Society
    • /
    • v.48 no.2
    • /
    • pp.141-146
    • /
    • 2011
  • Successful coating of high quality glassy carbon is introduced by applying high pressure during the curing process of dip-coated phenol resin on graphite. The dependence of the applied pressure on the quality of the glassy carbon layer has not been reported so far. Pressure was changed from 0 to 400 psi during curing at $200^{\circ}C$. After carbonized at $1100^{\circ}C$ in inert atmosphere for the 400 psicured sample, as a promising result, a thick (~ 3 mm) and smooth glassy carbon layer could be obtained without any breakage, and the yield of carbonization was remarkably increased. It is believed that the cross-linking of resins results in decreasing volatile contents and, thus, increasing the yield of the glassy carbon. The origin of the improvement is discussed on the basis of several analytical results including FE-SEM, FT-IT and Raman spectrum.

A Study on the Applicability of 3D Ceramic Printing Technology for Restoration of the Missing Part of Damaged Ceramics (훼손 도자기 결실부 복원을 위한 3D 세라믹 프린팅 기술의 기초 적용성 연구)

  • Oh, Seung-Jun;Wi, Koang-Chul
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.11
    • /
    • pp.165-173
    • /
    • 2020
  • ABS and PLA are applied for restoring missing part of damaged ceramics, but are not similar to the material of ceramics, so this study conducted a research on the properties and applicability of ceramic resin. This study conducted actual restoration of ABS and ceramic resin as well as cast restoration method with experiment of properties. Results show that manufacturing of restored part showed higher precision than existing materials, which enables printing of tiny shapes showing excellent surface texture and gloss than L30 and ABS resin. As a result of measuring properties, the material showed excellent durability than existing materials with no contraction and deformation and compressive strength, but value of specific gravity and hardness can lower processability after manufacturing. Long-term monitoring, evaluation of reliability of ceramic resin applied in this study, additional researches on the restorability of the original shape when printing too thin or long restored part are needed.

Shear bond strength of a new self-adhering flowable composite resin for lithium disilicate-reinforced CAD/CAM ceramic material

  • Erdemir, Ugur;Sancakli, Hande Sar;Sancakli, Erkan;Eren, Meltem Mert;Ozel, Sevda;Yucel, Taner;Yildiz, Esra
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.6
    • /
    • pp.434-443
    • /
    • 2014
  • PURPOSE. The purpose of this study was to evaluate and compare the effects of different surface pretreatment techniques on the surface roughness and shear bond strength of a new self-adhering flowable composite resin for use with lithium disilicate-reinforced CAD/CAM ceramic material. MATERIALS AND METHODS. A total of one hundred thirty lithium disilicate CAD/CAM ceramic plates with dimensions of $6mm{\times}4mm$ and 3 mm thick were prepared. Specimens were then assigned into five groups (n=26) as follows: untreated control, coating with $30{\mu}m$ silica oxide particles ($Cojet^{TM}$ Sand), 9.6% hydrofluoric acid etching, Er:YAG laser irradiation, and grinding with a high-speed fine diamond bur. A self-adhering flowable composite resin (Vertise Flow) was applied onto the pre-treated ceramic plates using the Ultradent shear bond Teflon mold system. Surface roughness was measured by atomic force microscopy. Shear bond strength test were performed using a universal testing machine at a crosshead speed of 1 mm/min. Surface roughness data were analyzed by one-way ANOVA and the Tukey HSD tests. Shear bond strength test values were analyzed by Kruskal-Wallis and Mann-Whitney U tests at ${\alpha}=.05$. RESULTS. Hydrofluoric acid etching and grinding with high-speed fine diamond bur produced significantly higher surface roughness than the other pretreatment groups (P<.05). Hydrofluoric acid etching and silica coating yielded the highest shear bond strength values (P<.001). CONCLUSION. Self-adhering flowable composite resin used as repair composite resin exhibited very low bond strength irrespective of the surface pretreatments used.

THE STUDY ON THE COLOR STABILITY OF RESIN CEMENT USED IN ALL CERAMIC CROWN (전부도재관에 사용되는 레진시멘트의 색안정성에 관한 연구)

  • Lee Tae-Hee;Lee Young-Soo;Park Won-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.1
    • /
    • pp.41-48
    • /
    • 2004
  • Statement of problem : The Cement as well as restoration required esthetics for making natural color restoration. Purpose : The purpose of this research is to evaluate color stability of restoration intermediated by resin cement which is used for cementation of all ceramic crown. Material and method : After making Empress 2 ingot into the size of $10mm{\times}10mm{\times}1mm$ according to indication, it glazed and made 48 Empress 2 blocks. Three kinds of resin cement(Rely-X, Variolink 2, Choice) having same shade cemented between Empress 2 blocks and Ivory shade tiles and made 48 specimens in the thickness of $30{\mu}m$ and $80{\mu}m$. After measureing color difference using spectorphotomenter, the result of this study were as follows. Results : The color difference of resin cement used in experiment increased in the order Rely-X, Variolink 2. As the thickness of cement increases, the color difference of all kinds of cement found statistically sifnificant difference but, this result is clinically acceptable. Conclusion : More resarch would have to be done in order to decrease the color difference as cement's thickness.

Effec of different zirconia primers on shear bond strengths of composite resin to bonded zirconia (지르코니아 프라이머 종류에 따른 복합레진-지르코니아의 전단결합강도)

  • Shi, Hong-Bing;Kim, Tae-Seok;Ahn, Jae-Seok;Lee, Jung-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.38 no.3
    • /
    • pp.135-142
    • /
    • 2016
  • Purpose: The aim of this research was to evaluate the influence of different surface treatments on the shear bond strength of zirconia ceramic to composite resin. Methods: Seventy two cylinder-shape (diameter: 5 mm; height: 12 mm) blocks of experimental industrially manufactured Y-TZP ceramic were abraded with $125{\mu}m\;Al_2O_3$ particles and randomly divided into 4 groups. All the materials were categorized as group Gc(control group - composite resin veneering on zirconia surface), Gr - composite resin veneering after surface treatment of Rocatec system (3M ESPE, Seefeld, Germany) group; Gz - composite resin veneering after surface treatment of Zirconia primer (Z-primer, Bisco, U.S.A) group; Gm - composite resin veneering after surface treatment of zirconia primer (Monobond plus, ivoclar vivadent AG, Liechtenstein) group. Two different zirconia primers and Rocatec system were used to zirconia cylinders (n=16) onto the zirconia surface. Zirconia specimens, polished and roughened, were pretreated and composite bilayer cylinders bonded using conventional adhesive techniques. Results: Shear bond strengths were analyzed using single-factor ANOVA(p<0.05). Bond strength values achieved after airbone particle abrasion and zirconia surface pre-treatments(p<0.05). Conclusion: Shear bond strength tests denmonstrated that zirconia primer is a viable method to improved bond strength between zirconia ceramic core and veneering composites.

Effect of surface treatments on the bond strength of indirect resin composite to resin matrix ceramics

  • Celik, Ersan;Sahin, Sezgi Cinel;Dede, Dogu Omur
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.4
    • /
    • pp.223-231
    • /
    • 2019
  • PURPOSE. The purpose of this study was to evaluate the shear bond strength (SBS) of an indirect resin composite (IRC) to the various resin matrix ceramic (RMC) blocks using different surface treatments. MATERIALS AND METHODS. Ninety-nine cubic RMC specimens consisting of a resin nanoceramic (RNC), a polymer-infiltrated hybrid ceramic (PIHC), and a flexible hybrid ceramic (FHC) were divided randomly into three surface treatment subgroups (n = 11). In the experimental groups, untreated (Cnt), tribochemical silica coating (Tbc), and Neodymium-Doped Yttrium Aluminum Garnet (Nd:YAG) laser irradiation (Lsr) with 3 W (150 mJ/pulse, 20 Hz for 20 sec.) were used as surface treatments. An indirect composite resin (IRC) was layered with a disc-shape mold ($2{\times}3mm$) onto the treated-ceramic surfaces and the specimens submitted to thermal cycling (6000 cycles, $5-55^{\circ}C$). The SBS test of specimens was performed using a universal testing machine and the specimens were examined with a scanning electron microscope to determine the failure mode. Data were statistically analyzed with two-way analysis of variance (ANOVA) and Tukey HSD test (${\alpha}=.05$). RESULTS. According to the two-way ANOVA, only the surface treatment parameter was statistically significant (P<.05) on the SBS of IRC to RMC. The SBS values of Lsr-applied RMC groups were significantly higher than Cnt groups for each RMC material, (P<.05). Significant differences were also determined between Tbc surface treatment applied and untreated (Cnt) PIHC materials (P=.039). CONCLUSION. For promoting a reliable bond strength during characterization of RMC with IRC, Nd:YAG laser or Tbc surface treatment technique should be used, putting in consideration the microstructure and composition of RMC materials and appropriate parameters for each material.