• Title/Summary/Keyword: central electrode

Search Result 106, Processing Time 0.033 seconds

Automatic Extraction Techniques of Topic-relevant Visual Shots Using Realtime Brainwave Responses (실시간 뇌파반응을 이용한 주제관련 영상물 쇼트 자동추출기법 개발연구)

  • Kim, Yong Ho;Kim, Hyun Hee
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.8
    • /
    • pp.1260-1274
    • /
    • 2016
  • To obtain good summarization algorithms, we need first understand how people summarize videos. 'Semantic gap' refers to the gap between semantics implied in video summarization algorithms and what people actually infer from watching videos. We hypothesized that ERP responses to real time videos will show either N400 effects to topic-irrelevant shots in the 300∼500ms time-range after stimulus on-set or P600 effects to topic-relevant shots in the 500∼700ms time range. We recruited 32 participants in the EEG experiment, asking them to focus on the topic of short videos and to memorize relevant shots to the topic of the video. After analysing real time videos based on the participants' rating information, we obtained the following t-test result, showing N400 effects on PF1, F7, F3, C3, Cz, T7, and FT7 positions on the left and central hemisphere, and P600 effects on PF1, C3, Cz, and FCz on the left and central hemisphere and C4, FC4, P8, and TP8 on the right. A further 3-way MANOVA test with repeated measures of topic-relevance, hemisphere, and electrode positions showed significant interaction effects, implying that the left hemisphere at central, frontal, and pre-frontal positions were sensitive in detecting topic-relevant shots while watching real time videos.

Interstitial Hyperthermia by Radiofrequency Needle Electrode System : Phantom and Canine Brain Studies (8 MHz 라디오파를 이용한 자입식 온열치료 -조직등가물질을 통한 온도분포 및 개 뇌실질의 조직병리 변화에 관한 연구-)

  • Lee, Hyung-Sik;Chu, Sung-Sil;Sung, Jin-Sil;Suh, Chang-Ok;Kim, Gwi-Eon;Loh-John-Juhn-Kyu;Kim, Young-Soo;Kim, Sun-Ho;Chung, Song-Sup;Han, Eun-Kyung;Kim, Tae-Seung
    • Radiation Oncology Journal
    • /
    • v.9 no.1
    • /
    • pp.27-35
    • /
    • 1991
  • An interstitial radiofrequency needle electrode system was constructed for interstitial heating of brain tissue. Radiofrequency electrodes with Thermotron RF 8 were tested in an agar phantom and in a normal canine brain to determine how variations in physical factors affected temperature distributions. Temperature distributions were checked after heating with 1 mm diameter needle electrode implants on the corners of 1 and 2 cm squares in a phantom and plot isotherms for various electrodes arrangement. We observed that the 1 cm square array would heat a volume with a 1.25 cm radius circular field cross section to therapeutic temperatures ($90\%$ relative SAR using Tm) and the 2 cm square array with a 1.75 cm radius rectangular field with central inhomogeneity. With 2 cm long electrode implants, we observed that the 1 cm square array would heat a 3 cm long sagittal section to therapeutic temperature ($90\%$ relative SAR using Tm). We found that radiofrequency electrodes could be selected to match the length of the heating area without affecting its performance. The histopathological changes associated with RF heating of normal canine brains have been correlated with thermal distributions. RF needle electrode heating was applied for 50min to generate tissue temperatures of $43^{\circ}C$. We obtained a quarter of the heated tissue material immediately after heating and sacrificed at intervals from $7\sim30$days. The acute stage (immediately after heating) was demonstrated by liquefactive necrosis, pyknosis of neuronal element in the gray matter and by some polymer-phonuclear leukocytes infiltration. The appearance of lipid-laden macrophages surrounding the area of liquefaction necrosis was demonstrated in all three sacrificed dogs. Mild gliosis occurring around the necrosis was demonstrated in the last sacrificed (Days 30) canine brain.

  • PDF

A Study on the Detection Characteristics in Glucose and Fabrication of Bi-Enzyme Electrode using Electrochemical Method (전기화학적 방법을 이용한 다중 효소 전극 제작 및 글루코스 검출 특성에 관한 연구)

  • Han, Kyoung Ho;Shin, In Seong;Yoon, Do-Young
    • Journal of the Korean Electrochemical Society
    • /
    • v.23 no.3
    • /
    • pp.66-72
    • /
    • 2020
  • In this study, the development of biosensors capable of bi-enzyme reactions by including Horseradish peroxidase and glucose oxidase was carried out for detection of glucose. The sensors were manufactured using electro deposition method to reduce production time, and screen printed electrodes (SPE) were used to produce economical sensors. To check the bienzyme effect, the sensor was compared and analyzed with single enzyme biosensor. The characteristics of the sensor were evaluated using scanning electron microscopy(SEM), cyclic voltammetry(CV), electrochemical impedance spectroscopy(EIS), chronoamperometry(CA), and flow injection analysis(FIA). Analysis results from SEM, CV and EIS confirmed that the enzymes are well fixed to the electrode surface. In addition, it was confirmed that bi-enzyme biosensors manufactured from the CA method improved signal performance by 200% compared to single enzyme biosensors. From this results, we were able to explain that HRP and GOD react catalyzed to each other. And the results of FIA showed that the intensity of each current signal was constant when the same concentration of glucose was injected four times. In addition, by analyzing the intensity of current signals for glucose concentrations, the biosensors manufactured in this study showed excellent trends in signal sensitivity, reproducibility and stability.

Characteristics and Pathways of the Somatosensory Evoked Field Potentials in the Rat (흰쥐에서 체감각유발장전위의 기록부위별 특성과 경로분석)

  • Shin, Hyun Chul;Park, Yong Gou;Lee, Bae Hwan;Ryou, Jae Wook;Zhao, Chun Zhi;Chung, Sang Sup
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.7
    • /
    • pp.831-841
    • /
    • 2001
  • Objective : Somatosensory evoked potentials(SSEPs) have been used widely both experimentally and clinically to monitor the function of central nervous system and peripheral nervous system. Studies of SSEPs have reported the various recording techniques and patterns of SSEP. The previous SSEP studies used scalp recording electrodes, showed mean vector potentials which included relatively constant brainstem potentials(far-field potentials) and unstable thalamocortical pathway potentials(near-field potentials). Even in invasive SSEP recording methods, thalamocortical potentials were variable according to the kinds, depths, and distance of two electrodes. So they were regarded improper method for monitoring of upper level of brainstem. The present study was conducted to investigate the characteristics of somatosensory evoked field potentials(SSEFPs) of the cerebral cortex that evoked by hindlimb stimulation using ball electrode and the pathways of SSEFP by recording the potentials simultaneously in the cortex, VPL nucleus of thalamus, and nucleus gracilis. Methods : In the first experiment, a specially designed recording electrode was inserted into the cerebral cortex perpendicular to the cortical surface in order to recording the constant cortical field potentials and SSEFPs mapped from different areas of somatosensory cortex were analyzed. In the second experiment, SSEPs were recorded in the ipsilateral nucleus gracilis, the contralateral ventroposterolateral thalamic nucleus(VPL), and the cerebral cortex along the conduction pathway of somatosensory information. Results : In the first experiment, we could constantly obtain the SSEFPs in cerebral cortex following the transcutaneous electrical stimulation of the hind limb, and it revealed that the first large positive and following negative waves were largest at the 2mm posterior and 2mm lateral to the bregma in the contralateral somatosensory cortex. The second experiment showed that the SSEPs were conducted by way of posterior column somatosensory pathway and thalamocortical pathway and that specific patterns of the SSEPs were recorded from the nucleus gracilis, VPL, and cerebral cortex. Conclusion : The specially designed recording electrode was found to be very useful in recording the localized SSEFPs and the transcutaneous electrical stimulation using ball electrode was effective in evoking SSEPs. The characteristic shapes, latencies, and conduction velocities of each potentials are expected to be used the fundamental data for the future study of brain functions, including the hydrocephalus model, middle cerebral artery ischemia model, and so forth.

  • PDF

Studies of Electric Double Layer Capacitors Used For a Storage Battery of Dye Sensitized Solar Cell Energy

  • Kim Hee-Je;Jeon Jin-An;Sung Youl-Moon;Yun Mun-Soo;Choi Jin-Young
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.2
    • /
    • pp.251-256
    • /
    • 2006
  • To design the effective usage of electric double layer capacitors (EDLCs) used for a storage device of dye sensitized solar cell (DSC) energy, we first investigated the accumulation state of electrical charges and the charge behavior in the EDLCs. Based on the results, the voltage characteristics of EDLCs connected to DSC energy were evaluated. The results showed that the charge accumulation region concentrated on the central part of the carbonaceous electrode in EDLCs and the required times for charging and discharging were almost the same.

Effect of Electric Fields on the Propagation Speed of Tribrachial Flames in Coflow Jets (동축류 제트에서 삼지화염 전파의 전기장 효과에 대한 실험적 연구)

  • Won, Sang-Hee;Chung, Suk-Ho;Cha, Min-Suk
    • 한국연소학회:학술대회논문집
    • /
    • 2006.10a
    • /
    • pp.220-226
    • /
    • 2006
  • The effect of electric fields on the propagation speed of tribrachial flames has been investigated in a coflow jet by observing the transient flame propagation behavior after ignition. Without having electric fields, the propagation speed of tribrachial flame edges showed a typical behavior by having an inverse proportionality to the mixture fraction gradient at the flame edge. The behavior of flame propagation with the electric fields was investigated by applying high voltage to the central fuel nozzle and the enhancement of propagation speed has been observed by varying the applied voltage and frequency for AC electric fields. The propagation speed of tribrachial flame was also investigated by applying negative and positive DC voltages to the nozzle and similar improvements of the propagation speed were also observed. The propagation speeds of tribrachial flames in both the AC and DC electric fields were correlated well with the electric field intensity, defined by the electric voltage divided by the distance between the nozzle electrode and the edge of tribrachial flames.

  • PDF

A Study on the high frequency ozonizer according to vacuum of central electrode (중심전극의 진공도에 따른 고주파 오존발생기에 관한 연구)

  • Lee, C.H.;Chun, B.J.;Lee, S.K.;Woo, S.H.;Song, H.J.;Choi, S.T.;Lee, K.S.
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1811-1813
    • /
    • 2004
  • 본 논문에서는 2개의 유전체와 3개의 전극을 사용한 중첩방전형 오존발생기(Superposed Discharge Type Ozonizer, SDO)를 설계 제작한 후 중심전극 진공도 변화에 따른 고조파 오존발생기의 방전특성 및 오존생성특성을 연구하고, 방전 공간 내부에서 소비되는 에너지양을 측정하기 위하여 Lissajous법을 이용하였다.

  • PDF

Studies of electric double layer capacitors used for a storage battery of dye sensitized solar cell energy (염료감응형 태양전지의 축전지로 사용되는 전기이중층콘덴서에 대한 연구)

  • Choi, Jin-Young;Lee, Im-Geun;Hong, Ji-Tae;Kim, Hee-Je
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.11a
    • /
    • pp.673-676
    • /
    • 2005
  • To design the effective usage of electric double layer capacitors (EDLCs) used for a storage device of dye sensitized solar cell(DSC) energy, we first investigated the accumulation state of electrical charges and the charge behavior in the EDLCs. Based on the results. the voltage characteristics of EDLCs connected to DSC energy were evaluated. The results showed that the charge accumulation region concentrated on central part of the carbonaceous electrode in EDLCs and the required times for charging and discharging were almost the same.

  • PDF

Process Optimization Approached by Design of Experiment Method for Ga-doped ZnO Thin Films (DOE 법에 의한 Ga 첨가된 ZnO 박막의 공정조건 탐색)

  • Lee, Deuk-Hee;Kim, Sang-Sig;Lee, Sang-Yeol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.1
    • /
    • pp.108-112
    • /
    • 2010
  • Design of experiment (DOE) method is employed for a systematic and highly efficient optimization of Ga-doped ZnO thin films synthesized by pulsed laser deposition (PLD) process. We sequentially adopted fractional-factorial design (FD) and central composite design (CCD) of the DOE methods. In fractional-FD stage, significant factors to make conductive electrode are found to target-substrate (T-S) distance and oxygen partial pressure. Moreover, correlation among the process factors is elucidated using surface profile modeling. Electrical properties of the GZO films grown on a glass substrate had been optimized to find that the lowest electrical resistivity of about $1.8'10^{-4}Wcm$ which was acquired with the T-S distance and the oxygen pressure of 4 cm and 7 mTorr, respectively. During the DOE-fueled optimization process, the transparency of the GZO films is ensured higher than 85 %.

The Characteristics of Discharge and Ozone Concentration for plate type ozonizer with Discharge Area variation (평판형 오존발생기의 방전면적에 따른 방전 및 오존생성특성)

  • Lee, Chang-Ho;Lee, Sang-Keubn;Song, Hyun-Jig;Kim, Jong-Hyun;Youn, Byung-Han;Lee, Kwang-Sik
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.346-349
    • /
    • 2007
  • In this paper, the ozonizer is equipped with three electrodes ( two external electrodes, central electrode ), and AC high voltage which has 180[$180^{circ}C$] phase difference is applied to two H V. Ozone discharge and generation charactristics have been investigated in accordance with output voltage of power supply, flow-rate, discharge power. Ozone concentration, generation and yield were proportionally increased with increasing discharge area size.

  • PDF