• Title/Summary/Keyword: center point

Search Result 5,026, Processing Time 0.038 seconds

A Study on the Effect that Rehabilitation Education Influence on the Knowledge Attitude and Practice of Public Health Nurse (재활교육이 보건간호사의 재활에 대한 지식, 태도, 실천에 미치는 효과 연구)

  • Jo, Kye-Suk;You, In-Ja;Bae, Jung-Hee;Lee, Young-Ja
    • The Korean Nurse
    • /
    • v.36 no.5
    • /
    • pp.63-73
    • /
    • 1998
  • The home visiting health nurses are important man-power who can serve various and persistent rehabilitation care to disabled person in community. The Community Based Rehabilition project(CBR) of national rehabilition center have been carried out from 1995. As a part of that project national health center performed rehabilition education program for home visiting health nurses. The purpose of this study is to analysis the effect of this education. In the first stage all of those groups were educated for two weeks in national rehabilitation center. But only two group nurses, one is in a urban and the other in a rural community, have been educated continually in the field through discussing rehabilitation care case study. The data in this study were gathered from three group healh nurses and analysed by SAS computer program. The results about knowledge, attitude and practice changes of the three group nurses were as follows. 1. In the pre education state the mean point of all nurses' attitude for rehabilition was 59, but in the post education state that was 90. The difference between pre and post attitude is very significant(t=-14.1. p<0.0001l). 2. In the pre education state the mean point of all nurses' knowledge for rehabilition was 45, but in the post education state that was 78. The difference between pre and post knowledge is very significant(t=-12.7, p<0.000l). 3. In the pre education state the mean point of all nurses' practice for rehabilition care was 37, but in the post education state that was 62. The difference between pre and post practice is very significant(t=-7.3, p<0.000l). 4. In practice point, the two group nurses who have been educated continuously were superior to the other(t=-3.9. p<0.00l). 5. All points between the urban and rural nurses were no significant differences(p>0.l). 6. All changes of the attitude, knowledge and practice did not affected by age(F=0.58, p>0.l). professional career(F=O.61, p>0.l), educational background(F=0.97, p>0.l).

  • PDF

A Study on the Discharged Characteristics of the Pollutants using the Empirical Equation and Factor Analysis - Case Study of the Upper and Lower Watershed of South Han River (경험식과 요인분석을 통한 오염물질 유출 특성 연구 - 남한강 상·하류 수계 주요 하천을 중심으로)

  • Park, Ji Hyoung;Sohn, Su Min;Rhew, Doug Hee
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.6
    • /
    • pp.905-913
    • /
    • 2011
  • This study was conducted to characterize the discharge feature of pollutant load from the upper and lower watershed influencing on the water quality of South Han River using the empirical equation and Factor Analysis. The results of regression analysis between flow rate and pollutant load were as follows. In the streams of the upper watershed of South Han river, $BOD_5$ and $COD_{Mn}$ were increased as the flow rate was increased. Also, steep increases in SS and TP were observed with positive correlation with the flow rate while change in TN was slightly shown. On the other hand, in the streams of the lower watershed of South Han river, $BOD_5$ was negatively correlated with the flow rate, being decreased with the increase in the flow rate. However, changes in $COD_{Mn}$, TN, SS, and TP showed a similar trend with those observed in the upper watershed. With Factor Analysis of the water quality and various components, it was appeared that the flow rate, SS, and TP were significantly correlated each other and they were indicated as the principal component influencing on water quality in the streams of the upper watershed. In contrast, $BOD_5$, $COD_{Mn}$ and TOC were significantly correlated each other and they were included as the principal pollution component of the streams in the lower watershed. From these results, it was conclusive that the upper watershed of South Han River was mainly affected by non point source pollutants while the lower watershed was influenced by point source pollutants from the developed areas.

A study on coil temperature bariation in 75% hydrogen batch annealing furnace (75% 수소 BATCH 소둔시에서의 코일 온도변화에 관한 연구)

  • Jeon, Eon-Chan;Kim, Soon-Kyung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.11 no.2
    • /
    • pp.173-181
    • /
    • 1994
  • A Cold spot temperature control system for the batch annealing furnace has been estabilished in order to reduce energy consumption to improve productivity and stabilize the propertics of products. Therefore we confirmed a relation between annealing cycle time and atmospheric gas, variation of coil cold spot temperature with time during heating and actual temperature measurements at mid-width of each coil during heating and actual temperature measurements at mid-width of each coil during soaking. The results of the tempaeature variation effect on the batch annealing are as follows. 1) Heating time is reduced to one half with increasing atmospheric gas flow rate and changing of atmospheric gas component from HNx to Ax gas, and annealing cycle time is reduced to 2.7 times. 2) In case of short time healing, the slowest heating part is the center of B coil, in case of long time heating, the low temperature point moves from the center of coil to inside coil. And the temperature in this part is higher than other parts when cooling. When finished heating, the cold spot is located 1/3 of coil inside in case of HNx atmospheric gas. But center of coil in case of Ax atmospheric gas. 3) The outside of top coil is the highest temperature point when heating, which becomes the lowest temperature point when cooling. So, this point becomes high temperature zone at heating and low temperature zone at cooling, It has relation according to atmospheric gas component and flow rate. 4) Soaking time at batch annealing cycle determination is made a decision by the input coil width, and soaking time for quality homogenization of 1214mm width coil must be 2.5 hours longer than that of 914mm width coil for the same ciol weight. 5) Annealing cycle time with Ax atmospheric gas is extended 1 hour in of slow cooling during 5 hours in order to avoid rapid cooling.

  • PDF

Comparative study of pulse point using hemodynamics (혈류역학을 이용한 촌구와 인영의 특성비교)

  • Shin, Sang-hoon;Park, Dae-hun;Park, Young-jae;Park, Young-bae
    • Journal of Acupuncture Research
    • /
    • v.21 no.5
    • /
    • pp.241-248
    • /
    • 2004
  • Objectives : The purpose of this study is to examine the hemodynamic characteristics of pulse point. Methods : The computational analysis algorithms of arterial tree system was derived. In order to investigate the effect of internal organ on the pulse point, the diameter of celiac artery was reduced by half. Results : The sensitivity of flow change at the Inyoung(Renying) is better than that of the Chongu(Cunkou). but the Inyoung was worse than the Chongu in the point of the left and right symmetry. The pressure changes at the Inyoung and the Chongu were in the similar range. Conclusions : It was found from the result that the Chongu shows the more symmetrical hemodynamic characteristics than the Inyoung.

  • PDF

An Efficient Approach to Circular Curve Fitting of Articulated Manipulators Using Least Squares (최소자승법을 이용한 수직다관절 Manipulator의 원호보간에 관한 효과적인 방법)

  • 김대영;최은재;정원지;서영교;홍형표
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.570-575
    • /
    • 2002
  • This paper presents a new circular curve fitting approach of articulated manipulators, based on pseudoinverses. The paper aims at gaining the interpolation of circle from n data points, under the condition that the fitted circle should pass both a start point and an end point. In this paper, two algorithms of circular interpolation are presented. Prior to circular interpolation, are a spherical fitting should be performed, using least squares. In the first algorithm, the relationship between point data and normal vector on the sphere is used. In the second algorithm. the equation of plane which can be obtained from 3 points, i.e., a start point, an end point, and center of a sphere. The proposed algorithms are show to be efficient by using MATLAB-based simulation.

  • PDF

A Study on Constant Power Generation Algorithms for a Whole Range Power Point Tracking in Photovoltaic Systems (태양광 시스템의 전 범위 전력점 추종을 위한 CPG 알고리즘에 관한 연구)

  • Yang, Hyoung-Kyu;Bang, Taeho;Bae, Sunho;Park, Jung-Wook
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.2
    • /
    • pp.111-119
    • /
    • 2019
  • In this study, constant power generation (CPG) algorithms are introduced for whole range power point tracking in photovoltaic systems. Currently, maximum power point tracking (MPPT) algorithm is widely used for high-power photovoltaic systems. However, MPPT algorithm cannot flexibly control such systems according to changing grid conditions. Maintaining grid stability has become important as the capacity of grid-connected photovoltaic systems is increased. CPG algorithms are required to generate the desired power depending on grid conditions. A grid-connected photovoltaic system is configured, and CPG algorithms are implemented. The performances of the implemented algorithms are compared and analyzed by experimental results.

Dense Thermal 3D Point Cloud Generation of Building Envelope by Drone-based Photogrammetry

  • Jo, Hyeon Jeong;Jang, Yeong Jae;Lee, Jae Wang;Oh, Jae Hong
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.39 no.2
    • /
    • pp.73-79
    • /
    • 2021
  • Recently there are growing interests on the energy conservation and emission reduction. In the fields of architecture and civil engineering, the energy monitoring of structures is required to response the energy issues. In perspective of thermal monitoring, thermal images gains popularity for their rich visual information. With the rapid development of the drone platform, aerial thermal images acquired using drone can be used to monitor not only a part of structure, but wider coverage. In addition, the stereo photogrammetric process is expected to generate 3D point cloud with thermal information. However thermal images show very poor in resolution with narrow field of view that limit the use of drone-based thermal photogrammety. In the study, we aimed to generate 3D thermal point cloud using visible and thermal images. The visible images show high spatial resolution being able to generate precise and dense point clouds. Then we extract thermal information from thermal images to assign them onto the point clouds by precisely establishing photogrammetric collinearity between the point clouds and thermal images. From the experiment, we successfully generate dense 3D thermal point cloud showing 3D thermal distribution over the building structure.

Continuous Separation of Lysozyme from Egg White by Ion Exchange Column Chromatography (이온교환 칼럼 크로마토그래피를 이용한 난백에서 Lysozyme의 연속추출)

  • Park, Seong-Joon;Kim, Hyeon-Seok;Kim, Hyean-Wee;Ahn, Tae-Hoe;Park, Ki-Moon;Choi, Chun-Un
    • Korean Journal of Food Science and Technology
    • /
    • v.22 no.6
    • /
    • pp.711-715
    • /
    • 1990
  • Continuous column chromatographic separation of lysozyme from egg white was investigated. A weak acid type cation exchange resin, Duolite C-464, was used because of high lysozyme recovery and ease of column operation in this experiment. The resin was equilibrated at $pH\;7.9{\pm}0.1$ in Na+form. Continuous lysozyme separation was processed by repeating cycles(one cycle : resin equilibration, flow egg white, rinse, lysozyme elution) in automated preparative Liquid Chromatography(LC) system(column size ; i.d. 50 mm, resin bed volumn ; 1020 ml). At comparison of UV levels in rinse end point and elution end point of every cycle, the UV levels of rinse end point are maintained below 30% for 19 cycles and that of elution end point are also maintained below 30% for 17 cycles, stably, but was increased above 50% after 18 cycle. That indicated the eluting ability of lysozyme was reduced conspicuously after 18 cycle in continuous cycling process. The recovery of lysozyme was maintained above 90% from one to 17 cycle, but was decreased to 72% and 65% in 18 cycle and 19 cycle, respectively.

  • PDF