• 제목/요약/키워드: center detection

검색결과 3,807건 처리시간 0.037초

Janus - Multi Source Event Detection and Collection System for Effective Surveillance of Criminal Activity

  • Shahabi, Cyrus;Kim, Seon Ho;Nocera, Luciano;Constantinou, Giorgos;Lu, Ying;Cai, Yinghao;Medioni, Gerard;Nevatia, Ramakant;Banaei-Kashani, Farnoush
    • Journal of Information Processing Systems
    • /
    • 제10권1호
    • /
    • pp.1-22
    • /
    • 2014
  • Recent technological advances provide the opportunity to use large amounts of multimedia data from a multitude of sensors with different modalities (e.g., video, text) for the detection and characterization of criminal activity. Their integration can compensate for sensor and modality deficiencies by using data from other available sensors and modalities. However, building such an integrated system at the scale of neighborhood and cities is challenging due to the large amount of data to be considered and the need to ensure a short response time to potential criminal activity. In this paper, we present a system that enables multi-modal data collection at scale and automates the detection of events of interest for the surveillance and reconnaissance of criminal activity. The proposed system showcases novel analytical tools that fuse multimedia data streams to automatically detect and identify specific criminal events and activities. More specifically, the system detects and analyzes series of incidents (an incident is an occurrence or artifact relevant to a criminal activity extracted from a single media stream) in the spatiotemporal domain to extract events (actual instances of criminal events) while cross-referencing multimodal media streams and incidents in time and space to provide a comprehensive view to a human operator while avoiding information overload. We present several case studies that demonstrate how the proposed system can provide law enforcement personnel with forensic and real time tools to identify and track potential criminal activity.

Rhodamine Cyclen-based Fluorescent Chemosensor for the Detection of Cd2+

  • Shim, So-Young;Tae, Jin-Sung
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권spc8호
    • /
    • pp.2928-2932
    • /
    • 2011
  • A chemosensor based on a rhodamine-hydroxamate platform containing a pyridine and a cyclen binding units has been developed for the detection of $Cd^{2+}$ in aqueous solutions. The probe responds selectively toward $Cd^{2+}$ over other biologically relevant metal ions. The fluorescent probe shows 1:1 binding stoichiometry and the detection limit for $Cd^{2+}$ in water proved to be as low as 25 nM.

단일 클래스 분류기를 이용한 위조 홍채 검출 방법 (A Fake-Iris Detection Method using SVDD)

  • 이성주;김재희
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2007년도 하계종합학술대회 논문집
    • /
    • pp.287-288
    • /
    • 2007
  • In this paper, we propose a fake-iris detection method. In order to detect the fake-iris, we measure physiological features which are the reflectance ratio of the iris to the sclera at 750 nm and that at 850nm. In order to classify live and fake iris features, we use support vector data description (SVDD). From our experimental results, it is clear that our fake-iris detection method achieves high performance when distinguishing between a live-iris and a fake-iris.

  • PDF

Fast Holographic Image Reconstruction Using Phase-Shifting Assisted Depth Detection Scheme for Optical Scanning Holography

  • Lee, Munseob;Min, Gihyeon;Kim, Nac-Woo;Lee, Byung Tak;Song, Je-Ho
    • ETRI Journal
    • /
    • 제38권4호
    • /
    • pp.599-605
    • /
    • 2016
  • For the implementation of a real-time holographic camera, fast and automatic holographic image reconstruction is an essential technology. In this paper, we propose a new automatic depth-detection algorithm for fast holography reconstruction, which is particularly useful for optical scanning holography. The proposed algorithm is based on the inherent phase difference information in the heterodyne signals, and operates without any additional optical or electrical components. An optical scanning holography setup was created using a heterodyne frequency of 4 MHz with a 500-mm distance and 5-mm depth resolution. The reconstruction processing time was measured to be 0.76 s, showing a 62% time reduction compared to a recent study.

Nanoscale-NMR with Nitrogen Vacancy center spins in diamond

  • Lee, Junghyun
    • 한국자기공명학회논문지
    • /
    • 제24권2호
    • /
    • pp.59-65
    • /
    • 2020
  • Nitrogen-Vacancy (NV) center in diamond has been an emerging versatile tool for quantum sensing applications. Amongst various applications, nano-scale nuclear magnetic resonance (NMR) using a single or ensemble NV centers has demonstrated promising results, opening possibility of a single molecule NMR for its chemical structural studies or multi-nuclear spin spectroscopy for quantum information science. However, there is a key challenge, which limited the spectral resolution of NMR detection using NV centers; the interrogation duration for NV-NMR detection technique has been limited by the NV sensor spin lifetime (T1 ~ 3ms), which is orders of magnitude shorter than the coherence times of nuclear spins in bulk liquid samples (T2 ~ 1s) or intrinsic 13C nuclear spins in diamond. Recent studies have shown that quantum memory technique or synchronized readout detection technique can further narrow down the spectral linewidth of NMR signal. In this short review paper, we overview basic concepts of nanoscale NMR using NV centers, and introduce further developments in high spectral resolution NV NMR studies.

분산전원의 Anti-islanding용 수정된 zero-crossing 방식 주파수 검출기법 (A frequency measurement based on modified zero-crossing method for anti-islanding detection of distributed generation)

  • 배병열;백승택;이진희;서인영
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.634-636
    • /
    • 2008
  • This paper proposes a frequency detection method based on an advanced zero-crossing technique. Zero-crossing method for detecting frequency is one of the most widely used methods today. Although it is simple to apply, it requires extra hardware in implementation due to its limitations in accuracy. The proposed method models the error generated during zero crossing linearization and compensated for it in real time which makes it simple and accurate. The validity of the method and its applicability in anti-islanding detection of distributed generators was confirmed through simulation.

  • PDF

하나의 경로를 가진 항공기 탑재형 Bistatic Spotlight SAR 영상형성을 위한 Range Migration Algorithm의 확장 (Extension of Range Migration Algorithm for Airborne Single Track Bistatic Spotlight SAR Imaging)

  • 신희섭;전재한;임종태
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2008년도 하계종합학술대회
    • /
    • pp.165-166
    • /
    • 2008
  • Bistatic spotlight synthetic aperture radar(BSSAR) with single track configuration uses the transmitter and the receiver which travel along the single track such as the leader-follower. For the BSSAR imaging, we modify the range migration algorithm. In time domain, we make the monostatic SAR using shifting of path, Then, in frequency domain, we compensate the separated distance between the scene center and the flight path using the principle of the stationary phase (PSP).

  • PDF

공조 시뮬레이터를 이용한 고장진단 실험 연구 (An Experimental Study on Fault Detection in the HVAC Simulator)

  • 태춘섭;양훈철;조수;장철용
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.807-813
    • /
    • 2006
  • The objective of this study is to develop a rule-based fault detection algorithm and an experimental verification using an artificial air handling unit. To develop an analytical algorithm which precisely detects a tendency of faulty component, energy equations at each control volume of AHU were applied. An experimental verification was conducted on the HVAC simulator. The rule based FDD algorithm isolated a faulted sensor from HVAC components in summer and winter conditions.

  • PDF

Rapid and Sensitive Detection of Hepatitis C Virus in Clinical Blood Samples Using Reverse Transcriptase Polymerase Spiral Reaction

  • Sun, Wenying;Du, Ying;Li, Xingku;Du, Bo
    • Journal of Microbiology and Biotechnology
    • /
    • 제30권3호
    • /
    • pp.459-468
    • /
    • 2020
  • This study established a new polymerase spiral reaction (PSR) that combines with reverse transcription reactions for HCV detection targeting 5'UTR gene. To avoid cross-contamination of aerosols, an isothermal amplification tube (IAT), as a separate containment control, was used to judge the result. After optimizing the RT-PSR reaction system, its effectiveness and specificity were tested against 15 different virus strains which included 8 that were HCV positive and 7 as non-HCV controls. The results showed that the RT-PSR assay effectively detected all 8 HCV strains, and no false positives were found among the 7 non-HCV strains. The detection limit of our RT-PSR assay is comparable to the real-time RT-PCR, but is more sensitive than the RT-LAMP. The established RT-PSR assay was further evaluated for detection of HCV in clinical blood samples, and the resulting 80.25% detection rate demonstrated better or similar effectiveness compared to the RT-LAMP (79.63%) and real-time RT-PCR (80.25%). Overall, the results showed that the RT-PSR assay offers high specificity and sensitivity for HCV detection with great potential for screening HCV in clinical blood samples.

Screening for down syndrome using trophoblast retrieval and isolation of the cervix: preliminary study

  • Lee, Min Jin;Kim, Soo Hyun;Park, Hee Jin;Shim, Sung Han;Jang, Hee Yeon;Cha, Dong Hyun
    • Journal of Genetic Medicine
    • /
    • 제17권2호
    • /
    • pp.68-72
    • /
    • 2020
  • Purpose: Trisomy 21, the cause of Down syndrome (DS) with various medical problems, is the most common aneuploidy during the fetal period. For diagnosis, a non-invasive screening test using maternal blood, which cannot be confirmed and invasive confirmation test with a risk of miscarriage, may be performed. The trophoblast retrieval and isolation of the cervix (TRIC) have been proposed by some researchers as an alternative to overcome the limitations of current tests. We experimented using TRIC to identify the possibility of trisomy 21 for the first time in Asia. Materials and Methods: Three cases of DS were analyzed confirmed by invasive tests (chorionic villus sampling, amniocentesis). All samples of trophoblasts immediately were immersed in phosphate-buffered saline and processed with formalin for fixation. The trophoblasts were isolated using an anti-human leukocyte antigen-G antibody coupled to magnetic nanoparticles. β-human chorionic gonadotropin (hCG)-expressing cells were considered as trophoblast cells, and the detection rate calculated. DS was confirmed by fluorescence in situ hybridization (FISH). Results: The mean trophoblast detection rate using β-hCG was 78.1%, and the detection rate using FISH was 22.2%. In all cases, the trisomy of chromosome 21 was identified. Conclusion: Trophoblast can be obtained from the five weeks of gestation and has a high detection rate, so it is noted that it can replace the current prenatal genetic test. To realize the clinical application as a prenatal genetic test, we will need additional efforts to identify trisomy 21 as well as other chromosomal abnormalities in future large-scale studies.