• Title/Summary/Keyword: center detection

Search Result 3,780, Processing Time 0.035 seconds

Embedment of structural monitoring algorithms in a wireless sensing unit

  • Lynch, Jerome Peter;Sundararajan, Arvind;Law, Kincho H.;Kiremidjian, Anne S.;Kenny, Thomas;Carryer, Ed
    • Structural Engineering and Mechanics
    • /
    • v.15 no.3
    • /
    • pp.285-297
    • /
    • 2003
  • Complementing recent advances made in the field of structural health monitoring and damage detection, the concept of a wireless sensing network with distributed computational power is proposed. The fundamental building block of the proposed sensing network is a wireless sensing unit capable of acquiring measurement data, interrogating the data and transmitting the data in real time. The computational core of a prototype wireless sensing unit can potentially be utilized for execution of embedded engineering analyses such as damage detection and system identification. To illustrate the computational capabilities of the proposed wireless sensing unit, the fast Fourier transform and auto-regressive time-series modeling are locally executed by the unit. Fast Fourier transforms and auto-regressive models are two important techniques that have been previously used for the identification of damage in structural systems. Their embedment illustrates the computational capabilities of the prototype wireless sensing unit and suggests strong potential for unit installation in automated structural health monitoring systems.

Osteoporosis and Osteoporotic Fractures in Gastrointestinal Disease

  • Oh, Hyun Jin;Ryu, Kum Hei;Park, Bum Joon;Yoon, Byung-Ho
    • Journal of Bone Metabolism
    • /
    • v.25 no.4
    • /
    • pp.213-217
    • /
    • 2018
  • Patients with gastrointestinal disease (GI) are at risk for osteopenia or osteoporosis, which can lead to fractures. Although these patients may be at risk from a young age, gastroenterologists often overlook this fact in practice. There are well-known GI diseases associated with osteopenia and osteoporosis, such as the post-gastrectomy state, inflammatory bowel disease (IBD), and celiac disease. As there is an increase in the prevalence of IBD patients, newly diagnosed celiac disease in adulthood, and gastric cancer survivors following gastrectomy, bone disease in these patients becomes an important issue. Here, we have discussed osteoporosis and fractures in GI disease, especially in the postgastrectomy state, IBD, and celiac disease. Although the pathogenesis of bone loss in each disease has not been fully identified, we have confirmed that the prevalence of osteoporosis and fractures in each of these diseases is high. There are scarce studies comparing the prevalence of osteoporosis or osteoporotic fractures in GI disease patients with studies in postmenopausal women, and specific guidelines for their management in each disease have not been established. Intensive surveillance and management are needed to ensure that these patients attain peak bone mass for age and sex to prevent fractures.

Fault Section Detection Scheme in Ungrounded Distribution System (비접지 배전계통에서 고장구간 검출 및 복구 알고리즘)

  • Yu, Fei;Choi, Myeon-Song;Lee, Seung-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.487-488
    • /
    • 2007
  • Fault section detection and service restoration is very important in ungrounded distribution system. Techniques currently used to track down faults are time consuming and cumbersome. A new scheme is developed based on communication technology, and the simulation result shows that the method can satisfy the requirement proposed.

  • PDF

Scene Change Detection Method using Color Histogram and Feature Detection Algorithm (색상 히스토그램과 특징점 추출 알고리즘을 활용한 장면 전환 검출 방법)

  • Hyunju Oh;Wanjin Ko;Jiyong Park
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2023.11a
    • /
    • pp.741-744
    • /
    • 2023
  • 장면 전환 검출에서 단일 특성을 사용하는 경우 발생 가능한 정확도 감소의 문제를 해결하기 위해 색상 히스토그램 분포 차 분석과 특징점 추출 알고리즘을 활용한 방법을 제안한다.

Adaptive Window-based Detection of Narcotics and Explosives using IMS Signals in Cargo Containers (화물 컨테이너 내 IMS 신호를 이용한 적응 윈도우 기반 마약 및 폭발물 검출)

  • Ju, Heesong;Kim, Donghyun;Cho, Sungyoon;Park, Kyungwon;Kim, Yangsub;Jeon, Wongi;Kwon, Kiwon
    • Journal of Internet Computing and Services
    • /
    • v.23 no.3
    • /
    • pp.57-65
    • /
    • 2022
  • International attempts to smuggle narcotics and explosives using ship or aircraft cargoes are on the rise. With the recent increase in the number of detection cases of narcotics and explosives in Korea, it is important to detect dangerous material (narcotics and explosives) through container searches at ports and airports, which are the main routes. This paper proposes a technique to detect dangerous material in cargo containers using the sampled output signal of ion mobility spectroscopy (IMS). The proposed technique estimates parameters such as a threshold, a window length, and a noise level for ion detection of the target dangerous material by using known materials in the initialization stage. The estimated parameters are used to detect the ions of the dangerous target material inside the containers. The proposed technique can be applied when the peak value of the IMS signal and the ion mobility are varying due to container environments.

Source and LVis based coincidence summing correction in HPGe gamma-ray spectrometry

  • Lee, Jieun;Kim, HyoJin;Kye, Yong Uk;Lee, Dong Yeon;Kim, Jeung Kee;Jo, Wol Soon;Kang, Yeong-Rok
    • Nuclear Engineering and Technology
    • /
    • v.54 no.5
    • /
    • pp.1754-1759
    • /
    • 2022
  • The activity of gamma-ray emitting nuclides is calculated assuming that each gamma-ray is detected individually; thus, the magnitude of the coincidence summing signal must be considered during activity calculations. Here, the correction factor for the coincidence summing effect was calculated, and the detection efficiencies of two HPGe detectors were compared. The CANBERRA Inc. GC4018 high-purity Ge detector provided an estimate for the peak-to-total ratio using a point source to determine the coincidence summing correction factor. The ORTEC Inc. GEM60 high-purity Ge detector uses EFFTRAN in LVis to obtain the parameters of the detector and source model and the gamma-gamma and gamma-X match estimates, in order to determine the coincidence summing correction factor. Nuclide analyses, radioactivity comparisons, and analyses of reference material samples were performed utilizing certified reference materials to accurately determine the detection efficiencies. For both Co-60 and Y-88, the detection efficiency for a point source increased by an average of at least 12-13%, whereas the detection efficiency determined using LVis increased by an average of at least 13-15%. The calculated radioactivity values of the certified reference material and reference material samples were accurate to within 3% and 6% of the measured values, respectively.

Multi-labeled Domain Detection Using CNN (CNN을 이용한 발화 주제 다중 분류)

  • Choi, Kyoungho;Kim, Kyungduk;Kim, Yonghe;Kang, Inho
    • Annual Conference on Human and Language Technology
    • /
    • 2017.10a
    • /
    • pp.56-59
    • /
    • 2017
  • CNN(Convolutional Neural Network)을 이용하여 발화 주제 다중 분류 task를 multi-labeling 방법과, cluster 방법을 이용하여 수행하고, 각 방법론에 MSE(Mean Square Error), softmax cross-entropy, sigmoid cross-entropy를 적용하여 성능을 평가하였다. Network는 음절 단위로 tokenize하고, 품사정보를 각 token의 추가한 sequence와, Naver DB를 통하여 얻은 named entity 정보를 입력으로 사용한다. 실험결과 cluster 방법으로 문제를 변형하고, sigmoid를 output layer의 activation function으로 사용하고 cross entropy cost function을 이용하여 network를 학습시켰을 때 F1 0.9873으로 가장 좋은 성능을 보였다.

  • PDF

Development and Characterization of Finger-type PIN Photodiode for Fluorescence Detection of RNA (RNA 형광 검출을 위한 Finger형 PIN 광다이오드의 제작 및 평가)

  • Kim, Ju-Hwan;Oh, Myung-Hwan;Ju, Byeong-Kwon
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.85-89
    • /
    • 2004
  • This paper represents the development of high sensitivity photo-sensor for the fluorescence detection in the integrated biological analysis system. The finger-type PIN photodiodes were fabricated as the photo-sensor, and had a high sensitivity ($I_{light}/I_{dark}$ = 8720). The interference filter consisted of $TiO_{2}$ and $SiO_{2}$ was directly deposited on the photodiodes. Deposited filter with 95.5% reflection under 532 nm and 98% transmission over 580 nm exceedingly decreased the magnitude of background signal in the detection. The PDMS micro-fluidic channels are bonded on the photodiode by $O_{2}$ plasma treatment. The detection current was proportional to two primary parameters (light intensity, concentration), and the on-chip detection system could detect fluorescence signals down to 100 nM concentration (LOD = Limit of detection of rhodamine).

Evaluation of Submucosal or Lymphovascular Invasion Detection Rates in Early Gastric Cancer Based on Pathology Section Interval

  • Kim, Young-Il;Kook, Myeong-Cherl;Choi, Jee Eun;Lee, Jong Yeul;Kim, Chan Gyoo;Eom, Bang Wool;Yoon, Hong Man;Ryu, Keun Won;Kim, Young-Woo;Choi, Il Ju
    • Journal of Gastric Cancer
    • /
    • v.20 no.2
    • /
    • pp.165-175
    • /
    • 2020
  • Purpose: The guidelines for pathological evaluation of early gastric cancer (EGC) recommend wider section intervals for surgical specimens (5-7 mm) than those for endoscopically resected specimens (2-3 mm). Studies in surgically resected EGC specimens showed not negligible lymph node metastasis risks in EGCs meeting the expanded criteria for endoscopic submucosal dissection (ESD). Materials and Methods: This retrospective study included 401 EGC lesions with an endoscopic size of ≤ 30 mm detected in 386 patients. Pathological specimens obtained by ESD or surgery were cut into 2-mm section intervals for reference. Submucosal or lymphovascular invasion (LVI) was evaluated arbitrarily in 4- or 6-mm section intervals. McNemar's tests compared the differences between submucosal and LVI. Results: Submucosal invasion was detected in 29.2% (117/401) and LVI in 9.5% (38/401) at 2-mm interval. The submucosal invasion detection rates in 4-mm intervals decreased to 88.0% or 90.6% (both P<0.001), while the LVI detection rates decreased to 86.8% or 57.9% (P=0.025 and P<0.001, respectively). In 6-mm intervals, the submucosal and LVI detection rates decreased further to 72.7-80.3% (P<0.001 for all three sets) and 55.3-63.2% (P<0.001 for all three sets), respectively. Among 150 out-of-indication cases at 2-mm interval, 4-10 (2.7%-6.7%) at 4-mm intervals, and 10-17 (6.7%-11.3%) at 6-mm intervals were misclassified as lesions meeting the curative resection criteria due to the underestimation of submucosal or LVI. Conclusions: After ESD, the 2-mm wide section interval was suitable for the pathological evaluation of focal submucosal or LVI. Thus, if an EGC lesion meets the expanded criteria for the ESD specimen pathological evaluation, it could be safely followed up.

A novel ceramic GEM used for neutron detection

  • Zhou, Jianrong;Zhou, Xiaojuan;Zhou, Jianjin;Jiang, Xingfen;Yang, Jianqing;Zhu, Lin;Yang, Wenqin;Yang, Tao;Xu, Hong;Xia, Yuanguang;Yang, Gui-an;Xie, Yuguang;Huang, Chaoqiang;Hu, Bitao;Sun, Zhijia;Chen, Yuanbo
    • Nuclear Engineering and Technology
    • /
    • v.52 no.6
    • /
    • pp.1277-1281
    • /
    • 2020
  • A novel ceramic Gas Electron Multiplier (GEM) has been developed to meet the demand of high counting rate for the neutron detection which is an alternative to 3He-based detector at China Spallation Neutron Source (CSNS). An experiment was performed to measure the neutron transmittance of ceramic-GEM and FR4-GEM at the small angle neutron scattering (SANS) instrument. The result showed the ceramic-GEM has higher transmittance and less self-scattering especially for cold neutrons. One single ceramic GEM could give a gain of 102-104 in the mixture gas of Ar and CO2 (90%:10%) and its energy resolution was about 27.7% by using 55Fe X ray of 5.9 keV. A prototype has been developed in order to investigate the performances of the ceramic GEM-based neutron detector. Several neutron beam tests, including detection efficiency, spatial resolution, two-dimensional imaging, and wavelength spectrum, were carried out at CSNS and China Mianyang Research Reactor (CMRR). The results show that the ceramic GEM-based neutron detector is a good candidate to measure the high intensity neutrons.