A Study on the Continuing Education of Dental Technicians (치과기공사의 보수교육에 관한 연구(I) -보수교육 실태와 인식을 중심으로 -)

  • Moon, Je-Hyuk
    • Journal of Technologic Dentistry
    • /
    • v.22 no.1
    • /
    • pp.179-198
    • /
    • 2000
  • Since dental prosthesis is made possible only when dental technicians give themselves to the study of knowledge and the acquisition of updated skills, continuing education is of great importance in that it makes up for the efforts of dental technicians. Accordingly, continuing education relates to a system designed to contribute to the enhancement of the talents of dental technicians and the dental health of the nation. Specialized knowledge and information may work as the best weapon to preserve their jbs. This is true of this modern society where no one can expecth to survive without acquiring knowledge and information constantly for work is getting more classified and more divirsifide. This paper is dedicated to take a look at the current condition of the continuing education of dental technicians and to come up with measure to make general evaluation and to improve continuing education. This research resorts to 609 questionnaires among 6433 copies save unfaithfully responded 34 copos with 6.431 dental technicians as the subjects enrolled in the Dental technician Association. The collected questionnaires consist of 365 dental technicians living in Seoul and of 244 ones, Which account for 11.8 percent of dental technicians enrolled in the association. Because dental technicians live more in local areas than Seoul, the generalization of this survey leaves something to be desired. I have come up with the following findings. 1. 6,431 dental technicians, or 36.3 percent of an total of 14,956 licensed dental technicians, were admitted as numbers of the Dental Tachnician Association as of October 31, 1999. In the '98 continuing education. 4,141 dental technicians among 4,711 dental technicians got relevant training, and in the '99 continuing education, 4,075 technicians, or 75.9 percent of 5,365 technicians got relevant training while 1,290 technicians or 24.2 percent, fail to get relevant training. 2. The survey has it that 38.1 percent of dental technicians are ignorant of the laws on continuing education, and that technicians staying in local communities(146 persons, or 61.6%) take more part in education than those living in the capital of Korea(159 persons, or 146%), and that the older they are, the more money they earn, the more carrer they have, the higher position they hold, the more part they take in education 3. According to the survey, those who have the experience of getting training more than three times account for 52 persons(16.8%) in Seoul and 47 persons(22.4%) in local districts(p<0.01). In terms of sanctions in relation to continuing education, 26 dental technicians(4.6%) say that they have ever gotten sanctions, and 533 dental technicians(95.4%) say that they haven't. And those who were absent from continuing education(72 technicians : 13.51%) didn't get any sanction. 4. In terms of the degree of understanding continuing education, local technicians(46.8% : 110 persons) have a higher understanding of continuing education than their countparts staying in Seoul(36.0% : 130). Continuing education is not the ultimate goal itself. It should be changed to motivate those who get education to be willing to take part in contunuing education, and to help dental technicians in a practical and specific way. And the branch societies should be developde to engage in more specialized and classified expert fields. Of course, the curriculum should be so selected that the conceptions of dental technicians may be reflected to the maximum extent, and the ultimate effores should be made to effect diversity in the ways of educational methods and to perfect the preparation of continuing education on the part of instructors. Regulations should be established in relation to continuing education with a veiew to enhancing the participation of continuing education and its effectiveness. The supervision of the Ministry of Health and Welfare is of great importance in this context. The regulation of continuing education is not administrative regulation, but the expression of national will to guarantee the medical service of the nation at highest level. Therefore, it is necessary that the Ministry of Health and Welfare should change their understanding of the needs for the continuing education of dental experts, and that the expertise of government employees in charge of continuing education should be expanded. It goes without saying that the government should suppory continuing education in a financial way so as to supply the person in charge of public welfare and control the quality of national medicine.

  • PDF

Fate of Heavy Metals in Activated Sludge: Sorption of Heavy Metal ions by Nocardia amarae

  • Kim, Dong-wook
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 1998.10a
    • /
    • pp.2-4
    • /
    • 1998
  • Proliferation of Nocardia amarae cells in activated sludge has often been associated with the generation of nuisance foams. Despite intense research activities in recent years to examine the causes and control of Nocardia foaming in activated sludge, the foaming continued to persist throughout the activated sludge treatment plants in United States. In addition to causing various operational problems to treatment processes, the presence of Nocardia may have secondary effects on the fate of heavy metals that are not well known. For example, for treatment plants facing more stringent metal removal requirements, potential metal removal by Nocardia cells in foaming activated sludge would be a welcome secondary effect. In contrast, with new viosolid disposal regulations in place (Code o( Federal Regulation No. 503), higher concentration of metals in biosolids from foaming activated sludge could create management problems. The goal of this research was to investigate the metal sorption property of Nocardia amarae cells grown in batch reactors and in chemostat reactors. Specific surface area and metal sorption characteristics of N. amarae cells harvested at various growth stages were compared. Three metals examined in this study were copper, cadmium and nickel. Nocardia amarae strain (SRWTP isolate) used in this study was obtained from the University of California at Berkeley. The pure culture was grown in 4L batch reactor containing mineral salt medium with sodium acetate as the sole carbon source. In order to quantify the sorption of heavy metal ions to N amarae cell surfaces, cells from the batch reactor were harvested, washed, and suspended in 30mL centrifuge tubes. Metal sorption studies were conducted at pH 7.0 and ionlc strength of 10-2M. The sorption Isotherm showed that the cells harvested from the stationary and endogenous growth phase exhibited significantly higher metal sorption capacity than the cells from the exponential phase. The sequence of preferential uptake of metals by N. amarae cells was Cu>Cd>Ni. The specific surFace area of Nocardia cells was determined by a dye adsorption method. N.amarae cells growing at ewponential phase had significantly less specific surface area than that of stationary phase, indicating that the lower metal sorption capacity of Nocardia cells growing at exponential phase may be due to the lower specific surface area. The growth conditions of Nocardia cells in continuous culture affect their cell surface properties, thereby governing the adsorption capacity of heavy metal. The comparison of dye sorption isotherms for Nocardia cells growing at various growth rates revealed that the cell surface area increased with increasing sludge age, indicating that the cell surface area is highly dependent on the steady-state growth rate. The highest specific surface area of 199m21g was obtained from N.amarae cell harvested at 0.33 day-1 of growth rate. This result suggests that growth condition not only alters the structure of Nocardia cell wall but also affects the surface area, thus yielding more binding sites of metal removal. After reaching the steady-state condition at dilution rate, metal adsorption isotherms were used to determine the equilibrium distributions of metals between aqueous and Nocardia cell surfaces. The metal sorption capacity of Nocardia biomass harvested from 0.33 day-1 of growth rate was significantly higher than that of cells harvested from 0.5- and 1-day-1 operation, indicatng that N.amarae cells with a lower growth rate have higher sorpion capacity. This result was in close agreement with the trend observed from the batch study. To evaluate the effect of Nocardia cells on the metal binding capacity of activated sludge, specific surface area and metal sorption capacity of the mixture of Nocardia pure cultures and activated sludge biomass were determined by a series of batch experiments. The higher levels of Nocardia cells in the Nocardia-activated sludge samples resulted in the higher specific surface area, explaining the higher metal sorption sites by the mixed luquor samples containing greater amounts on Nocardia cells. The effect of Nocardia cells on the metal sorption capacity of activated sludge was evaluated by spiking an activated sludge sample with various amounts of pre culture Nocardia cells. The results of the Langmuir isotherm model fitted to the metal sorption by various mixtures of Nocardia and activated sludge indicated that the mixture containing higher Nocardia levels had higher metal adsorption capacity than the mixture containing lower Nocardia levels. At Nocardia levels above 100mg/g VSS, the metal sorption capacity of activate sludge increased proportionally with the amount of Noeardia cells present in the mixed liquor, indicating that the presence of Nocardia may increase the viosorption capacity of activated sludge.

  • PDF

Comparison Radiation Dose of Z-Axis Automatic Tube Current Modulation Technique with Fixed Tube Current Multi-Detector Row CT Scanning of Lower Extremity Venography (하지 정맥조영술 MDCT에서 고정 관전류 기법과 Z-축 자동 관전류 변동 제어에 의한 선량 비교)

  • Yoo, Beong-Gyu;Lee, Jong-Seok;Jang, Keun-Jo;Jeon, Sang-Hwan;Kim, Yong-Soo;Kweon, Dae-Cheol
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.3
    • /
    • pp.123-133
    • /
    • 2007
  • Z-axis automatic tube current modulation technique automatically adjusts tube current based on size of body region scanned. The purpose of the current study was to compare noise, and radiation dose of multi-detector row CT (MDCT) of lower extremity performed with Z-axis modulation technique of automatic tube current modulation with manual selection fixed tube current. Fifty consecutive underwent MDCT venography of lower extremity with use of a MDCT scanner fixed tube current and Z-axis automatic tube current modulation technique (10, 11 and 12 HU noise index, $70{\sim}450\;mA$). Scanning parameters included 120 kVp, 0.5 second gantry rotation time, 1.35:1 beam pitch, and 1 mm reconstructed section thickness. For each subject, images obtained with Z-axis modulation were compared with previous images obtained with fixed tube current (200, 250, 300 mA) and with other parameters identical. Images were compared for noise at five levels: iliac, femoral, popliteal, tibial, and peroneal vein of lower extremity. Tube current and gantry rotation time used for acquisitions at these levels were recorded. All CT examinations of study and control groups were diagnostically acceptable, though objective noise was significantly more with Z-axis automatic tube current modulation. Compared with fixed tube current, 2-axis modulation resulted in reduction of CTDIvol (range, $-6.5%{\sim}-35.6%$) and DLP (range, $-0.2%{\sim}-20.2%$). Compared with manually selected fixed tube current, 2-axis automatic tube current modulation resulted in reduced radiation dose at MDCT of lower extremity venography.

Physicochemical Characteristics of Sikhye (Korean Traditional Rice Beverage) with Specialty Rice Varieties (특수미 품종에 따른 식혜의 이화학적 특성)

  • Kim, Kee-Jong;Woo, Koan-Sik;Lee, Jin-Seok;Chun, A-Reum;Choi, Yoon-Hee;Song, Jin;Suh, Sae-Jung;Kim, Sun-Lim;Jeong, Heon-Sang
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.37 no.11
    • /
    • pp.1523-1528
    • /
    • 2008
  • This study was carried out to compare the physicochemical characteristics and sensory quality of Sikhye (a Korean traditional rice beverage) prepared with specialty rice varieties. The results showed that Ilpum had higher hulling recovery, milled/brown rice ratio, and milling recovery than Sulgaeng, Baegjinju, Baegjinju 1, and Dongjinchal. The alkali digestive value, protein content, and amylose contents of Sulgaeng were 6.3, 7.3% and 19.3%, respectively. The highest brix degree was $10.00^{\circ}Bx$ in Baegjinju Sikhye. The turbidity appeared at 0.4440, 0.4100, 0.3828, 0.3372, 0.1414 in Ilpum, Baegjinju, Baegjinju 1, Sulgaeng, and Dongjinchal Sikhye, respectively. There were no significant differences in pH and maltose contents among the groups. The highest L-value was 44.62 in Ilpum Sikhye. The a-value and b-value were $-1.66{\sim}-0.70$ and $-9.18{\sim}-5.19$, respectively. Finally, the sensory evaluation results indicated that there were no significant differences in appearance, aroma, and taste between the groups, and the Sulgaeng Sikhye showed higher overall quality than the Dongjinchal Sikhye as the control.

Analysis of radiation exposure in radiation worker in medical facility and student in clinical practice (의료기관 방사선작업종사자와 임상실습 학생의 피폭선량 분석)

  • Lee, Joo-Ah;Choi, Kwan-Woo;Min, Jung-Whan;Lim, Jong-Cheon;Son, Soon-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.8
    • /
    • pp.442-448
    • /
    • 2016
  • This study was conducted to determine the appropriateness of systemic radiation exposure control for students in clinical practice by comparing radiation exposure in radiography employees at different stations of a hospital with that of students conducting clinical practice using identical stations. Overall, 121 students who conducted clinical practice in the department of radiology area of C university hospital from July 2014 to August 2014 and 62 workers working in the same medical facility (47 in the department of radiology, 8 in the department of radiation oncology, 7 in the department of nuclear medicine) were investigated. The radiation exposure experienced by students was measured for 8 weeks, which is the duration of the clinical practice. Additionally, radiation exposure of workers were classified into 4 groups, department of radiology, department of radiation oncology, and department of nuclear medicine was compared. Dose was measured with OSLD and differences among groups were identified by ANOVA followed by Duncan's multiple range test. Among employees, those in the department of radiology, oncology and nuclear medicine were exposed depth doses of $0.127{\pm}0.331mSv$, $0.01{\pm}0.003mSv$, and $0.431{\pm}0.205mSv$, respectively, while students were exposed to $0.143{\pm}0.136mSv$. Additionally, workers in the department of radiology, oncology and nuclear medicine were exposed to surface doses of $0.131{\pm}0.331mSv$, $0.009{\pm}0.003mSv$, and $0.445{\pm}0.198mSv$, respectively, while students were exposed to $0.151{\pm}0.14mSv$, which was significantly different in both doses (p < 0.01). The average dose that students received is higher than that of the other groups (except for nuclear medicine workers), indicating that further improvements must be made in systemic controls for individual radiation exposure by including the students as subjects of management for protection from radiation.

A Five-year Epidemiologic Study of Childhood Leukemia in Busan City, 1996 to 2000 (최근 5년간(1996-2000) 부산지역 소아 백혈병 환자에 대한 역학적 연구)

  • Moon, Jae Hoon;Lee, Soon Yong;Sinn, Jong Beom;Park, Jae Sun;Lee, Young Ho;Lim, Young Tak;Park, Su Eun
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.10
    • /
    • pp.972-976
    • /
    • 2003
  • Purpose : For the control of childhood leukemia, of which the mortality is still high, the basic data for the incidence has a great importance. The authors analyzed the data from 133 new patients with childhood leukemia between 1996-2000 in Busan, Korea. Methods : The data were obtained from 133 new cases(87 males and 46 females from 0 to 15 years old) of childhood leukemia who were residents of Busan and who were admitted to the 4 university hospitals and 11 general hospitals from 1996 to 2000. Results : The total number of the new childhood leukemia patients was 133 between 1996-2000; the average annual number of new patients was 26.6. The age-and-sex adjusted annual incidence rate (/100,000) was in the range of 2.37-4.53(male 2.47-5.29, female 0.76-3.36) with an average of 3.29 (male 4.05, female 2.43). Age-specific annual incidence rate(/100,000) was 3.78 in the 0-4 year age group, 3.51 in the 5-9 year age group and 3.08 in the 10-14 year age group. Of the major types of childhood leukemia, the distribution of ALL was average 71.4%, of AML 23.3%, and of CML 4.5%. Of the major types of leukemia by age range, ALL showed highest in the 5-9 year age group, while AML in 0-4 and 10-14 year age groups. Sex-ratio(male to female) of major type of leukemia was 1.97 : 1 and 1.21 : 1, in ALL and AML groups, respectively, while all were male in CML. Conclusion : The average age-and-sex adjusted annual incidence rate(/100,000) of childhood leukemia in Busan from 1996 to 2000 was 3.29. Compared to data in related articles, this data suggests a steady increase in the incidence of childhood leukemia in the Busan area over the last 20 years since 1981.

Evaluation of Temperature and Humidity of a Thermo-Hygrostat of PET/CT Equipment using a Temperature and Humidity Sensor(BME 280) (온·습도센서(BME 280 센서)를 이용한 PET/CT 장비의 항온 항습기 온·습도 평가)

  • Ryu, Chan-Ju;Kim, Jeong-A;Kim, Jun-Su;Yun, Geun-Yeong;Heo, Seung-Hui;Hong, Seong-Jong
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.1
    • /
    • pp.15-22
    • /
    • 2020
  • PET(Positron Emission Tomography) devices are used as PET/CT or PET/MRI devices fused with the devices of CT or MRI for obtaining anatomical information. Therefore, the devices are constructed in circular ring-type structure whose length of gantry(the main part of filming) becomes wider and the interior depth becomes longer in comparison to other common medical equipments. scintillator, one of the components in PET devices, is inside the gantry, and as it is consisted of crystal which is sensitive to the change of temperature and humidity, large temperature change can cause the scintillator to be damaged. Though scintillator located inside the gantry maintains temperature and humidity with a thermo-hygrostat, changes in temperature and humidity are expected due to structural reasons. The output value was measured by dividing the inside of the gantry of the PET/CT device into six zones, each of which an Adafruit BME 280 temperature and humidity sensor was placed at. A thermo-hygrostat keeps the temperature and humidity constant in the PET/CT room. As the measured value of temperature and humidity of the sensor was obtained, the measured value of temperature and humidity appeared in the thermohygrostat was taken at the same time. Comparing the average measured values of temperature and humidity measured at each six zones with the average values of the thermo-hygrostat results in a difference of 2.71℃ in temperature and 21.5% in humidity. The measured temperature and humidity of PET Gantry is out of domestic quality control range. According to the results of the study, if there is continuous change in temperature and humidity in the future, the aging of the scintillator mounted in the PET Gantry is expected to be aging, so it is necessary to find a way to properly maintain the temperature and humidity inside the Gantry structure.

The Effects of Aprotinin Addition and Plastic Tube Usage for Glucagon Test Results (Glucagon 검사시 Aprotinin 첨가와 Plastic tube 사용이 미치는 영향)

  • Cho, Youn-Kyo;Choi, Sam-Kyu;Seo, So-Yeon;Shin, Yong-Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.117-120
    • /
    • 2011
  • Purpose: There are 3 warnings for Glucagon tests. First, EDTA tubes that already contain Aprotinin must be used for plasma collection. Second, for freezer storage of centrifuged plasma, glass tubes must be used. Last, glass tubes must be used for testing procedure. So we compared the glucagon results of next 3 situation to those of control group. First, We compared to results by tubes without Aprotinin and with aprotinin. Second, we compared to results by tubes(plastic vs glass) for plasma storage. Third, we compared to results by tubes(plastic vs glass) for testing. We tried to evaluate the results of the 3 different condition. Materials and Methods: 40 healthy adults were studied with normal results on the general medical check up and laboratory tests. We compared the results of 3 different condition belows: Blood were collected in EDTA tube containing aprotinin and plasma was stored in the glass tube for 3 days in a freezer and results were obtained by tests in the glass tubes. Results from EDTA plasma without aprotinin, results from platic tubes for freezer stroage, results from plastic tube when testing. Simple linear regression analysis and paired t-test using SPSS were done for statistical analysis. Commercial glucagon kit(RIA-method)which made by Siemens company were used. Results: Correlation coefficient between results of EDTA tubes with Aprotinin vs without Aprotinin was r=0.783 (p=0.064). Result of specimen in plastic tubes stored 3 days in a freezer showed lower value compared to those in glass tube(r=0.979, p=0.005). Also, results of testing in plastic tubes showed lower values than those testing in glass tubes. (r=0.754, p<0.001). Conclusion: It is recommended for glucagon determination to use EDTA tube with Aprotinin which is a inhibitor of protein breakdown enzyme. Results of plastic tube when storage and testing showed lower value than those of glass tubes, so it is recommended to store and test in glass tubes.

  • PDF

Intracullular Functions of the mas2+ Gene in the Fission Yeast, Schizosaccharomyces pombe (분열형 효모에서의 mas2+ 유전자의 세포 내 기능)

  • Sin, Sang-Min;Cha, Jae-Young;Ha, Se-Eun;Sim, Sun-Mi;Kim, Hyoung-Do;Lee, Jung-Sup;Park, Jong-Kun
    • Journal of Life Science
    • /
    • v.19 no.1
    • /
    • pp.101-110
    • /
    • 2009
  • The regulation of gene expression plays an important role in cell cycle controls. In this study, a novel $mas2^+$ (mitosis associated protein) gene, a homolog of human SMARCAD1 was isolated and characterized from a fission yeast Schizosaccharomyces pombe (S. pombe) using gene-specific polymerase chain reaction. The isolated gene contained a complete open reading frame capable of encoding 922 amino acid residues with a typical promoter, as judged by nucleotide sequence analysis. It was also found that an SNF2 domain is located, which is involved in the chromosome remodeling. The quantitative analysis of the $mas2^+$ transcript against $adh1^+$ showed that the expression level of $mas2^+$ is high before septum formation in S. pombe. When $mas2^+$ null mutant cells were grown at 27 and $35^{\circ}C$, the cytokinesis of $mas2^+$ null mutant was greatly delayed and a large number of multi-septate and mis-segregated cells were produced. In addition, the number of multi-septate cells significantly increased. When cells were cultured in YES rich medium to increase proliferation, the abnormal phenotypes $mas2^+$ null mutant dramatically increased. These phenotypes could be rescued by an over-expression of the mast gene. The Mas2 protein localized in the nuclei of S. pombe, as evidenced by Mas2-EGFP signals. These results suggest that the $mas2^+$ is homologous to human SMARCAD1 gene and involved in septum formation and chromosome remodeling control.

Anti-oxidative Activities of Commercial Edible Plant Extracts Distributed in Korea (국내 유통 중인 식용식물 추출물의 항산화효과)

  • Kim, Kyung-Bum;Yoo, Ki-Hwan;Park, Ha-Yan;Jeong, Jong-Moon
    • Applied Biological Chemistry
    • /
    • v.49 no.4
    • /
    • pp.328-333
    • /
    • 2006
  • Many plant extracts are known to have antioxidative effects. However, their activities can be reduced or disappeared during mass production process. The purpose of this study is to compare antioxidative effects of edible plant extracts distributed in Korea. forty three kinds of edible plant extracts commercially available in Korea were selected and investigated for their total phenolics contents and antioxidative potentials(DPPH radical and superoxide anion radical scavenging activities). In contents of total phenolics, the commercial plant extracts from Artemisia annua(whole plant), Ilex paraguariensis(leaf, Silybum marianum(fruit and leaf, Ulmus pumila(bark), Coliolus versicolor(fruit), and Curcuma longa(root and stem) contained over 70 mg/g of powder, DPPH radical scavenging activities($SC_{50}$, 50% scavenging concentration) of A. annua, I. paraguariensis, Pinus densiflora(leaf),S. marianum, U. pumila, and C. longa were $53.96{\pm}0.81\;ppm,\;24.61{\pm}2.12\;ppm,\;35.96{\pm}1.11\;ppm,\;57.46{\pm}2.13\;ppm,\;55.25{\pm}1.65\;ppm\;and\;12.99{\pm}1.67ppm$, respectively, while that of positive control(vitamin C) was $3.86{\pm}0.81\;ppm$. $SC_{50}$ values against superoxide anion radical of A. annua, Cinnamomum zeylanicum(bark), I. paraguariensis, Rubus coreanus(fruit and leaf), Morus alba(leaf), P. densiflora, S. marianum, U. pumila, C. versicolor, C. longa, Perilla frutescens var. acuta(leaf), and H. sabdariffa(leaf and newer) were $53.21{\pm}1.83ppm,\;50.12{\pm}2.12ppm,\;5.59{\pm}0.84ppm,\;41.60{\pm}8.93ppm,\;20.19{\pm}0.97ppm,\;15.19{\pm}1.66ppm,\;21.20{\pm}1.88ppm,\;15.71{\pm}0.91ppm,\;55.48{\pm}2.42ppm,\;52.12{\pm}2.44ppm,\;23.80{\pm}1.98ppm\;and\;11.14{\pm}0.51ppm$, respectively($SC_{50}$ value of vitamin C: $9.61{\pm}0.93ppm$). In particular, both 1 paraguariensis and P. densiflora had high content of phenolics as well as high scavenging activities of DPPH radical and superoxide anion radical. Consequently, above two commercial extracts may be useful as a source of antioxidative nutraceutics.