• 제목/요약/키워드: cements

검색결과 570건 처리시간 0.025초

The effect of resin cements and primer on retentive force of zirconia copings bonded to zirconia abutments with insufficient retention

  • Kim, Seung-Mi;Yoon, Ji-Young;Lee, Myung-Hyun;Oh, Nam-Sik
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권2호
    • /
    • pp.198-203
    • /
    • 2013
  • PURPOSE. The purpose of this study was to investigate the effect of resin cements and primer on the retentive force of zirconia copings bonded to zirconia abutments with insufficient retention. MATERIALS AND METHODS. Zirconia blocks (Lava, 3M ESPE, St. Paul, MN, USA) were obtained and forty sets of zirconia abutments and copings were fabricated using CAD/CAM technology. They were grouped into 4 categories as follows, depending on the types of resin cements used, and whether the primer is applied or not:Panavia F2.0 (P), Panavia F2.0 using Primer (PRIME Plus, Bisco Inc, Schaumburg, IL, USA) (PZ), Superbond C&B (S), and Superbond C&B using Primer (SZ). For each of the groups, the cementation was conducted. The specimens were kept in sterilized water ($37^{\circ}C$) for 24 hours. Retentive forces were tested and measured, and a statistical analysis was carried out. The nature of failure was recorded. RESULTS. The means and standard deviations of retentive force in Newton for each group were $265.15{\pm}35.04$ N (P), $318.21{\pm}22.24$ N (PZ), $445.13{\pm}78.54$ N (S) and $508.21{\pm}79.48$ N (SZ). Superbond C&B groups (S & SZ) showed significantly higher retentive force than Panavia F2.0 groups (P & PZ). In Panavia F2.0 groups, the use of primer was found to contribute to the increase of retentive force. On the other hand, in Superbond C&B groups, the use of primer did not influence the retention forces. Adhesive failure was observed in all groups. CONCLUSION. This study suggests that cementation of the zirconia abutments and zirconia copings with Superbond C&B have a higher retentive force than Panavia F2.0. When using Panavia F2.0, the use of primer increases the retentive force.

Effect of ultrasonic agitation on push-out bond strength and adaptation of root-end filling materials

  • Alcalde, Murilo Priori;Vivan, Rodrigo Ricci;Marciano, Marina Angelica;Duque, Jussaro Alves;Fernandes, Samuel Lucas;Rosseto, Mariana Bailo;Duarte, Marco Antonio Hungaro
    • Restorative Dentistry and Endodontics
    • /
    • 제43권2호
    • /
    • pp.23.1-23.9
    • /
    • 2018
  • Objectives: This study evaluated the effect of ultrasonic agitation of mineral trioxide aggregate (MTA), calcium silicate-based cement (CSC), and Sealer 26 (S26) on adaptation at the cement/dentin interface and push-out bond strength. Materials and Methods: Sixty maxillary canines were divided into 6 groups (n = 10): MTA, S26, and CSC, with or without ultrasonic activation (US). After obturation, the apical portions of the teeth were sectioned, and retrograde cavities were prepared and filled with cement by hand condensation. In the US groups, the cement was activated for 60 seconds: 30 seconds in the mesio-distal direction and 30 seconds in the buccal-lingual direction, using a mini Irrisonic insert coupled with the ultrasound transducer. After the materials set, 1.5-mm thick sections were obtained from the apexes. The presence of gaps and the bond between cement and dentin were analyzed using low-vacuum scanning electron microscopy. Push-out bond strength was measured using a universal testing machine. Results: Ultrasonic agitation increased the interfacial adaptation of the cements. The S26 US group showed a higher adaptation value than MTA (p < 0.05). US improved the push-out bond strength for all the cements (p < 0.05). Conclusions: The US of retrograde filling cements enhanced the bond to the dentin wall of the root-end filling materials tested.

글라스 아이오노머 시멘트와 불소함유 레진의 불소유리에 관한 연구 (IN VITRO STUDY ON THE FLUORIDE RELEASE FROM GLASS IONOMER CEMENTS AND A FLUORIDE-CONTAINING RESIN)

  • 김미경;이기수
    • 대한치과교정학회지
    • /
    • 제28권3호
    • /
    • pp.399-407
    • /
    • 1998
  • 불소를 유리하는 치과재료인 글라스 아이오노머 시멘트와 불소함유 레진을 대상으로 경화후의 시간경과에 따른 1일간 불소유리량을 측정하고, 이들의 경시적 변화추세를 비교 검토하기 위하여 광중합형 글라스 아이오노머 시멘트로서 치과교정용 브라켓 접착제($Orthobond^{\circledR}$)와 충전응(Fuji GC $LC^{\circledR}$), 자가중합형 글라스 아이오노머 시멘트로서 충전용 (Fuji GC $II^{\circledR}$)과 아말감 합금이 첨가된 충전용(Miracle-$Mix^{\circledR}$) 및 광중합형 불소함유 충전용 레진($Heliomolar^{\circledR}$)을 실험재료로 하여 중합 1일, 3일, 7일, 14일, 42일, 70일 경과후 각각 불소유리량을 측정하고, 변화추세를 비교 검토하여 다음의 결론을 얻었다. 1. 전 실험기간에 걸쳐 불소함유 레진의 1일간 불소유리량은 글라스 아이포노머 시멘트에 비해 현저히 적었다. 2. 중합 70일 경과후 1일간 불소유리 량은 Miracle-$Mix^{\circledR}$는 평균 $3.4{\mu}g/cm^2$, Fuji GC $II^{\circledR}$가 평균 $2.7{\mu}g/cm^2$, $Orthobond^{\circledR}$가 평균 $2.3{\mu}g/cm^2$, Fuji GC $LC^{\circledR}$이 평균 $1.4{\mu}g/cm^2$였고, 불소함유 레진인 $Heliomolar^{\circledR}$은 평균 $0.1{\mu}g/cm^2$이었다. 3. 1일간 불소유리량은 자가중합형 글라스 아이오노머 시멘트와 광중합형 글라스 아이오노머 시멘트사미에 차이를 발견할 수 없었고, 제조회사의 제품에 따라 유의한 차이가 있었다 아말감 합금이 첨가된 Miracle-$Mix^{\circledR}$은 아말감 합금이 첨가되지 않은 다른 시멘트에 비해 현저히 많은 양의 불소를 유리하였다. 4. 모든 실험재료의 1일간 불소유리 량은 중합 3일이전까지 현저한 감소를 보였고, 중합 3일경과이후 중합 14일 이전까지 완만한 감소를, 중합 14일이후부터 중합 70일경과까지 매우 완만한 감소추세를 보였다.

  • PDF

짧은 티타늄 지대주에 합착된 CAD/CAM 금속 코핑의 시멘트 종류에 따른 유지력 비교 (Retention of CAD/CAM Metal Copings Cemented on Short Titanium Abutments with Different Cements)

  • 김효정;송은영;윤지영;이시호;이용근;오남식
    • 구강회복응용과학지
    • /
    • 제28권2호
    • /
    • pp.119-126
    • /
    • 2012
  • 시멘트 유지 임플란트 지지 수복물은 치과 치료에 일상적으로 사용된다. 임플란트와 지대주 나사연결의 안정적인 견고함과 골유합 임플란트의 높은 생존율로 인해 높은 강도를 가진 시멘트의 사용이 점차 늘어나고 있다. 그러나 CAD/CAM을 이용하여 제작한 금속 코핑의 유지력에 대해 이용할 수 있는 임상 자료가 없다. 네 종류의 시멘트를 이용하여 티타늄 지대주와 CAD/CAM을 이용하여 제작한 금속 코핑의 유지력을 평가하는 것과 시멘트 유지력에 대한 sandblasting의 효과를 알아보고자 함이다. 40개의 티타늄 지대주 블록(Innovium, 세라젬바이오시스, 대한민국)을 제작하여 네 그룹으로 나누었다. 40개의 금속 코핑을 CAD/CAM을 이용하여 제작하고 금속 코핑의 교합면 상방부에 유지력 테스트를 위해 구멍을 형성하였다. 네 종류의 시멘트는 Fujicem(Fuji, Japan), Maxcem Elite(Kerr, USA), Panavia F2.0(Kurarary, Japan), Superbond C&B(Sunmedical, Japan)이다. 금속 코핑과 티타늄 지대주를 제조사의 지시대로 시멘트 혼합하여 합착하고 100% 습도 하에 37도에서 24시간 동안 보관 후 유지력 테스트하였다. 유지 실패가 발생하는 힘을 newton으로 기록하고 실패의 양상 또한 기록하였다. 유지력의 평균과 표준 편차를 ANOVA와 Paired t-test 로 통계분석하였다. Panavia F2.0이 Fujicem과 Maxcem Elite보다 통계적으로 유의하게 높은 유지력을 보였다(p<0.05). Sandblasting이 모든 시멘트에서 유의하게 유지력을 증가시켰다(p<0.05). 유지력 실패의 양상은 대부분의 시멘트가 금속 코핑 내부에 남아있는 접착성 실패였다. 본 연구의 한계 내에서 Panavia F2.0이 Fujicem이나 Maxcem Elite보다 통계적으로 유의하게 큰 유지력을 보였고(p<0.05), Fujicem과 Maxcem Elite는 유지력의 차이를 보이지 않았다. Sandblasting처리는 모든 실험군에서 유지력의 향상을 보였다. 따라서 임플란트 지대주에 합착된 금속 코핑의 유지력은 표면 거칠기와 시멘트의 종류에 영향을 받는다.

카복실레이트계 시멘트의 접착력에 관한 비교 연구 (COMPARATIVE STUDIES OF THE ADHESIVE QUALITIES OF POLYCARBOXYLATE CEMENTS)

  • 이한무
    • 대한치과보철학회지
    • /
    • 제17권1호
    • /
    • pp.23-34
    • /
    • 1979
  • In this study, the adhesive strength of three commercial polycarboxylate cements to ten types of dental casting alloys, such as gold, palladium, silver, indium, copper, nickel, chromium, and human enamel and dentine were measured and compared with that of a conventional zinc phosphate cement. The $8.0mm{\times}3.0mm$ cylindrical alloy specimens were made by casting. The enamel specimens were prepared from the labial surface of human upper incisor, and the dentine specimens were prepared from the occulusal surface of the human molar respectively. Sound extracted human teeth, which had been kept in a fresh condition since, extraction, were mounted in a wax box with a cold-curing acrylic resin to expose the flattened area. The mounted teeth were then placed in a Specimen Cutter (Technicut) and were cut down under a water spray, and then the flat area on the all specimens were ground by hand with 400 and 600 grit wet silicone carbide paper. Two such specimens were then cemented together face-to-face with freshly mixed cement, and moderate finger pressure was applied to squeeze the cement to a thin and uniform film. All cemented specimens were then kept in a thermostatic humidor cabinet regulated at $23{\pm}2^{\circ}C.$ and more than 95 per cent relative humidity and tested after 24 hours and 1 week. Link chain was attached to each alloy specimen to reduce the rigidity of the jig assembly, and then all the specimens were mounted in the grips of the Instron Universal Testing Machine, and a tensile load was delivered to the adhering surface at a cross head speed of 0.20 mm/min. The loads to which the specimens were subjected were recorded on a chart moving at 0.50 mm/min. The adhesive strength was determined by measuring the load when the specimen separated from the cement block and by dividing the load by the area. The test was performed in a room at $23{\pm}2^{\circ}C.$ and $50{\pm}10$ per cent relative humidity. A minimum of five specimens were tested each material and those which deviated more than 15 per cent from the mean were discarded and new specimens prepared. From the experiments, the following results were obtained. 1) It was found that the adhesive strength of the polycarboxylate cement to all alloys tested was considerably greater than that of the zinc phosphate cement. 2) The adhesive strength of the polycarboxylate cements was superior to the non precious alloys, such as the copper, indium, nickel and chromium alloys, but it was inferior to the precious gold, silver and palladium alloys. 3) Surface treatment of the alloy was found to be an important factor in achieving adhesion. It appears that a polycarboxylate cement will adhere better to a smooth surface than to a rough one. This contrasts with zinc phosphate cements, where a rough helps mechanical interlocking. 4) The adhesion of the polycarboxylate cement with enamel was found superior to its adhesion with dentine.

  • PDF

섬유강화형 복합레진전장관의 변연적합도 및 변연누출에 관한 연구 (MARGINAL FITNESS AND MARGINAL LEAKAGE OF FIBER-REINFORCED COMPOSITE CROWNS DEFENDING UPON LUTING CEMENTS)

  • 김선종;신상완;한중석;서규원
    • 대한치과보철학회지
    • /
    • 제38권5호
    • /
    • pp.618-630
    • /
    • 2000
  • As Fiber-reinforced composite restorations cannot be made without leaving a marginal gap, luting cements play a pivotal role in sealing the margins as a prevention against margnal leakage. A recently introduced adhesive resin cement system is claimed to adhere chemically, as well as mechanically, to tooth substances, dental alloys and porcelain. But when considering the clinical variation conventional cementation using Zinc Phosphate and Glass-Ionomer can be requested. A vitro study was undertaken to compare microleakage and marginal fitness of Fiber-reinforced composite crowns(Targis/Vectris) depending upon luting cements. Fifty non-carious human premolar teeth were randomly divided into five experimental groups of 10 teeth each and luted with five luting cements. ($Bistite\;II^(R),\;Super-bond^(R),\;Variolink\;II^(R)$), Zinc phosphate and Glass-Ionomer cement) After 24 hours of being luted, all specimens were thermocycled 300 times through water bath of $5^{\circ}C\;and\;55^{\circ}C$ in each bath, then the quality of the marginal fitness was measured by the Digital Microscope and marginal leakage was characterized using Dye Penetration technique and the Digital Microscope The results were as follows : 1. The mean values of marginal fit were Bistite II($46.78{\mu}m$), Variolink II($56.25{\mu}m$), Super-Bond($56.78{\mu}m$), Glass-Ionomer($99.21{\mu}m$), Zinc Phosphate($109.49{\mu}m$) indicated a statistically significant difference at p<0.001. 2. The mean microleakage values of tooth-cement interface, restoration-cement interface were increased in the order of Variolink II, Bistite II, Super-Bond, Glass-Ionomer, Zinc Phosphate 3. Crowns luted with resin cement (Bistite II, Super-Bond, Variolink II, etc) exhibited less marginal gap and marginal leakage than those luted with conventional Glass-Ionomer and Zinc Phosphate cement. 4. The results indicated that all five luting systems yielded comparable and acceptable marginal fit.

  • PDF

3종 시멘트로 접착한 소아용 기성 지르코니아 전장관과 유치 상아질의 전단결합강도 (Shear Bonding Strength of Three Cements Luted on Pediatric Zirconia Crowns and Dentin of Primary Teeth)

  • 이정은;박호원;이주현;서현우
    • 대한소아치과학회지
    • /
    • 제45권3호
    • /
    • pp.314-323
    • /
    • 2018
  • 이 연구의 목적은 3종 시멘트의 전단결합강도를 평가하고 열순환 시행이 전단결합강도에 미치는 영향을 알아보고자 한다. 소아치과에서 사용되는 소아용 기성 지르코니아 전장관($NuSmile^{(R)}$ ZR crown)의 내면과 유사한 디스크 형태의 지르코니아 시편(Zirconia discs)을 제작하였다. 소아용 기성 지르코니아 전장관의 내면과 지르코니아 시편의 표면이 동일하도록 같은 몰드를 이용하여 제작하였으며 주사전자현미경을 통해 유사함을 확인하였다. 60개의 지르코니아 시편과 60개의 유구치 상아질 시편을 3종의 시멘트 $Ketac^{TM}$ Cem Permanent Glass Ionomer Luting Cement(KGI), $RelyX^{TM}$ Luting Plus Cement(RLP), $RelyX^{TM}$ Unicem Self-Adhesive Universal Resin Cement(RUR)에 따라 20개씩 나누고, 열순환 시행 유무에 따라 다시 10개씩 2개의 하위그룹으로 나누었다. 하위그룹 A는 열순환을 시행하지 않았고 하위그룹 B는 5500회의 열순환을 시행하였다. 만능 재료 시험기를 이용하여 전단결합강도를 측정한 후 파절 양상을 주사전사현미경으로 관찰하였다. 지르코니아 시편 및 유구치 상아질 시편에 접착한 시멘트의 전단결합강도는 RUR이 KGI와 RLP보다 높았으며 통계적으로 유의한 차이가 관찰되었다(p < 0.05). RUR의 전단결합강도는 열순환 시행하지 않은 군과 열순환 시행한 군 사이에 통계적으로 유의한 차이가 없었다.

다양한 레진시멘트로 합착한 섬유포스트의 결합강도 비교 (COMPARISON OF BOND STRENGTH OF A FIBER POST CEMENTED WITH VARIOUS RESIN CEMENTS)

  • 이현아;조영곤
    • Restorative Dentistry and Endodontics
    • /
    • 제33권6호
    • /
    • pp.499-506
    • /
    • 2008
  • 이 연구는 다양한 접착시스템을 사용하는 6가지 레진시멘트를 이용하여 근관에 합착한 섬유포스트를 push-out 검사에 의해 포스트와 치근 상아질 간의 결합강도를 상호 비교하기 위하여 시행되었다. 발거된 하악 소구치의 치관부를 제거하고 치근부를 근관충전한 후 9mm의 포스트 룸을 형성하였다. 사용된 레진시멘트의 종류에 따라서 무작위로 6개씩 선택하여 Duo-Link 군, Variolink II 군, Panavia F 군, Multilink Automix 군, RelyX Unicem 군, Maxcem 군으로 분류하였다. 제조사의 지시에 따라서 각각의 레진시멘트를 Uni-dose needle tip을 이용하여 근단부에서부터 주입하여 광투과성 섬유 포스트인 no. 2 DT Light Post를 근관에 합착하였다. 증류수에 24시간동안 보관한 후, 주수 하에 저속의 Diamond Wheel Saw를 이용하여 각 치근을 횡단면으로 1mm 두께로 절단하여 연속적인 절편 6개를 얻었다. 각 군의 시편을 universal testing machine에 고정하고 push-out 검사를 시행하여 push-out 강도를 통계 분석한 결과, 서로 다른 접착시스템을 사용한 레진시멘트 군간의 push-out 강도는 유의한 차이가 나타나지 않았다 (p > 0.05).

Evaluation of shear bond strength between dual cure resin cement and zirconia ceramic after thermocycling treatment

  • Lee, Jung-Jin;Kang, Cheol-Kyun;Oh, Ju-Won;Seo, Jae-Min;Park, Ju-Mi
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권1호
    • /
    • pp.1-7
    • /
    • 2015
  • PURPOSE. This study was performed to evaluate shear bond strength (SBS) between three dual-cured resin cements and silica coated zirconia, before and after thermocycling treatment. MATERIALS AND METHODS. Sixty specimens were cut in $15{\times}2.75mm$ discs using zirconia. After air blasting of $50{\mu}m$ alumina, samples were prepared by tribochemical silica coating with $Rocatec^{TM}$ plus. The specimens were divided into three groups according to the dual-cure resin cement used: (1) Calibra silane+$Calibra^{(R)}$, (2) Monobond S+$Multilink^{(R)}$ N and (3) ESPN sil+$RelyX^{TM}$ Unicem Clicker. After the resin cement was bonded to the zirconia using a Teflon mold, photopolymerization was carried out. Only 10 specimens in each group were thermocycled 6,000 times. Depending on thermocycling treatment, each group was divided into two subgroups (n=10) and SBS was measured by applying force at the speed of 1 mm/min using a universal testing machine. To find out the differences in SBS according to the types of cements and thermocycling using the SPSS, two-way ANOVA was conducted and post-hoc analysis was performed by Turkey's test. RESULTS. In non-thermal aged groups, SBS of Multilink group (M1) was higher than that of Calibra (C1) and Unicem (U1) group (P<.05). Moreover, even after thermocycling treatment, SBS of Multilink group (M2) was higher than the other groups (C2 and U2). All three cements showed lower SBS after the thermocycling than before the treatments. But Multilink and Unicem had a significant difference (P<.05). CONCLUSION. In this experiment, Multilink showed the highest SBS before and after thermocycling. Also, bond strengths of all three cements decreased after thermocycling.

글라스 아이오노머 수복재의 불소 유리 및 재흡수 양상 (FLUORIDE RELEASE AND RECHARGE OF GLASS IONOMER CEMENTS)

  • 배익현;김재문;김신;정태성
    • 대한소아치과학회지
    • /
    • 제32권1호
    • /
    • pp.136-143
    • /
    • 2005
  • 이차 우식은 수복 실패의 주된 원인 중 하나로 지목되고 있으며, 이로 인해 빈번히 재수복을 하게 된다. 이차 우식은 항우식 작용이 있는 불소를 함유한 수복물을 사용하여 예방될 수 있다. 구강내에서 불소를 유리하는 것으로 알려진 글라스 아이오노머 수복재는 불소를 장기간 유리할 뿐 아니라 불소의 재충전 및 재유리 능력이 있어 불소의 저장소 역할을 할 수 있다. 따라서 본 연구는 통상의 글라스 아이오노머와 고점도 글라스 아이오노머 및 복합 레진을 대상으로 불소의 유리 양상과 불소도포를 통한 재흡수 후 유리 양상을 알아봄으로써 기존의 수복재와 새로운 수복재간의 임상적 유용성을 평가할 목적으로 시행하였다. 4종의 수복재를 대상으로 불소 유리량 및 2% NaF로 재충전 후 불소 유리량을 각각 측정하여 다음과 같은 결과를 얻었다. 1. 실험 대상의 모든 글라스 아이오노머 수복재는 초기에 다량의 불소를 유리하고 이후 점차 감소하는 경향을 보였다. 2. 2% NaF 용액을 통한 재충전 후의 유리량은 Fuji IX, Ketac Fil, Ketac Molar, Z-100의 순으로 나타났다. 3. Fuji IX을 제외한 모든 실험 대상의 수복재에서 수분의 영향으로 표면 경도는 유의하게 감소하였고 불소 재충전 후 유리량은 수분 흡수와 비례하였다(P<0.05). 4. Fuji IX이 초기 유리량에 비해 재충전 후 더 많은 불소를 유리였다(P<0.05).

  • PDF