• Title/Summary/Keyword: cell monitoring

Search Result 724, Processing Time 0.033 seconds

Quantification of Half Cell Potential with Mix Properties in RC Member under Long-Term Chloride Exposure Conditions (장기 염해에 노출된 RC 부재의 배합 특성을 고려한 반 전위의 정량화)

  • Yoon, Yong-Sik;Jeong, Gi-Chan;Kwon, Seung-Jun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.10 no.3
    • /
    • pp.307-313
    • /
    • 2022
  • In this study, the correlation between Half Cell Potential(HCP) and the corrosion influencing factors was analyzed with considering three levels of water-cement ratio, the concentration of chloride solution, and cover depth. As a result of long-term corrosion monitoring, HCP behavior was close to the critical corrosion potential(-350 mV) in all water-cement ratios in the case of 3.5 % and 7.0 % chloride concentration. Regarding the passed charge test in 548 curing days, the passed charge results were improved to 'Moderate' grade. Multiple regression analysis was performed to evaluate the correlation between corrosion influencing factors and HCP, and it was evaluated that the effects of influencing factors to HCP were in the order of chloride concentration, water-cement ratio, and cover depth. In the case of the relationship between HCP and the passed charge, the coefficient of determination showed a high level of 0.9, which yielded a close correlation between the passed charge and HCP.

Immunocell Therapy for Lung Cancer: Dendritic Cell Based Adjuvant Therapy in Mouse Lung Cancer Model (폐암의 면역세포 치료: 동물 모델에서 수지상 세포를 이용한 Adjuvant Therapy 가능성 연구)

  • Lee, Seog-Jae;Kim, Myung-Joo;In, So-Hee;Baek, So-Young;Lee, Hyun-Ah
    • IMMUNE NETWORK
    • /
    • v.5 no.1
    • /
    • pp.36-44
    • /
    • 2005
  • Background: The anti-tumor therapeutic effect of autologous tumor cell lysate pulseddendritic cells (DCs) was studied for non-immunogenic and immune suppressive lung cancer model. To test the possibility as an adjuvant therapy, minimal residual disease model was considered in mouse in vivo experiments. Methods: Syngeneic 3LL lung cancer cells were inoculated intravenously into the C57BL/6 mouse. Autologous tumor cell (3LL) or allogeneic leukemia cell (WEHI-3) lysate pulsed-DCs were injected twice in two weeks. Intraperitoneal DC injection was started one day (MRD model) after tumor cell inoculation. Two weeks after the final DC injection, tumor formation in the lung and the tumor-specific systemic immunity were observed. Tumor-specific lymphocyte proliferation and the IFN-${\gamma}$ secretion were analyzed for the immune monitoring. Therapeutic DCs were cultured from the bone marrow myeloid lineage cells with GM-CSF and IL-4 for 7 days and pulsed with tumor cell lysate for 18 hrs. Results: Compared to the saline treated group, tumor formation was suppressed in 3LL tumor cell lysate pulsed-DC treated group, while 3LL-specific immune stimulation was minimum. WEHI-3-specific immune stimulation occurred in WEHI-3 lysate-pulsed DC treated group, which had no correlation with tumor regression. Conclusion: The data suggest the possible anti-tumor effect of cultured DCs as an adjuvant therapy for minimal residual disease state of lung cancer. The significance of immune modulation in DC therapy including the possible involvement of NK cell as well as antigen-specific cytotoxic T cell activity induction was discussed.

Performance Verification and Reliability Test of Load Cell Gauge in Korea (국내 하중계 성능검증과 신뢰성 시험 연구)

  • Kim, Yeong-Bae;Park, Yeong-Bae;Lee, Seong-Won;Lee, Kang-Il
    • Journal of the Korean Geotechnical Society
    • /
    • v.39 no.12
    • /
    • pp.103-114
    • /
    • 2023
  • Monitoring the site of an underground construction wall is crucial to confirm the stability of the supports and ground due to excavation. In particular, it is essential to maintain the accuracy of a load cell gauge, which identifies the load of the support transmitted from the excavated ground. However, research on verification methods and regulations that can identify the accuracy of load cell gauges at construction sites is inadequate, which is a problem as load cell gauges are installed without proper performance inspections. In this study, performance tests were conducted by a complete investigation of load cell gauges sold in Korea and comparing them with foreign products to determine defect causes. In addition, the criteria for selecting a load cell gauge were presented, and the results of this study were considered to help select a highly reliable load cell gauge.

CHARACTERISTIC ANALYSIS FOR GUARD LAMP USING SOLAR CELL (솔라셀을 적용한 보안등의 특성 분석에 관한 연구)

  • Kang, Byung-Bog;Ji, Woon-Seok;Lim, Jung-Yeol;Yu, Chang-Woo;Kim, Seok-Jong;Cha, In-Su
    • Proceedings of the KIEE Conference
    • /
    • 2004.04a
    • /
    • pp.196-200
    • /
    • 2004
  • A guard lamp system has been installed at the PV positive center, located at Gwangju in Korea. Digital environment that is represented to internet is displacing business way of industry and business achievement way with the fast speed being giving great change on life whole, improve existence business process utilizing internet and Web connection technology, information superhighway to tradition industrialist manufacture and e-transformation's propulsion that wish to maximize productivity and administration efficiency is spread vigorously. In this paper, we wish to accomplish generation equipment's heighten stability and believability through remote monitoring and control of guard lamp system. This paper describes the design of the monitoring system for the sensing data and indirect controlling of the guard lamp system. Most of the conventional monitoring systems depend on the special hardware and software. The essential design of monitoring system is to provide the convenience for the user and the portability for the system. In order for the system to fulfill its requirements, it was designed using Labview GUI facility based on the Windows 2000 environment of IBM PC compatible and Add-on card based on the TCP/IP protocol. Advantage of the monitoring system are a personnel expenses curtailment effect, of the place restriction and unmanned system of the generation plants, etc..

  • PDF

THE CHARACTERISTIC OF SOLAR CELL FOR GUARD LAMP (보안등에 적용하기 위한 태양전지의 특성 분석)

  • Kang Byung-Bog;Ji Woon-Seok;Lim Jung-Yeol;Kim Seok-Jong;Yu Chang-Woo;Cha In-Su
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1489-1491
    • /
    • 2004
  • A guard lamp system has been installed at the PV positive center, located at Gwangju in Korea. Digital environment that is represented to internet is displacing business way of industry and business achievement way with the fast speed being giving great change on life whole, improve existence business process utilizing internet and Web connection technology, information superhighway to tradition industrialist manufacture and e-transformation's propulsion that wish to maximize productivity and administration efficiency is spread vigorously. In this paper, we wish to accomplish generation equipment's heighten stability and believability through remote monitoring and control of guard lamp system. This paper describes the design of the monitoring system for the sensing data and indirect controlling of the guard lamp system. Most of the conventional monitoring systems depend on the special hardware and software. The essential design of monitoring system is to provide the convenience for the user and the portability for the system. In order for the system to fulfill its requirements, it was designed using Labview GUI facility based on the Windows 2000 environment of IBM PC compatible and Add-oncard based on the TCP/IP Protocol. Advantage of the monitoring system are a personnel expenses curtailment effect, of the place restriction and unmanned system of the generationplants, etc..

  • PDF

Response of Photobacterium phosphoreum to Heavy Metal (Photobacterium phosphoreum의 중금속에 대한 반응성)

  • 정계훈;김현숙;이은수;정성제;이정건;김은기;전억한
    • KSBB Journal
    • /
    • v.14 no.3
    • /
    • pp.342-350
    • /
    • 1999
  • Photobacterium phosphoreum was used in order to study response to heavy metal including $HgCl_2$, $CdCl_2$, $MnSO_4$ and $ZnSO_4$ in view of developing monitoring system for toxic substances. The concentrations of heavy metal causing 50% reduction($EC_{50}$) in bioluminescence intensity were determined with both free and immobilized P. phosphoreum. The bioluminescence responses were examined at various concentrations of heavy metal after 10, 20 and 30 min of exposure. The linear correlation between Gamma values and concentrations of heavy metal was obtained and $EC_{50}$ was calculated from the linear correlation. The significant inhibitory concentrations for bioluminescence emission were found to be 0.05mg/L for $HgCl_2$, 25mg/L for $CdCl_2$, 50mg/L for $MnSO_4$ and 12.5mg/L for $ZnSO_4$, respectively. The free cell and disc type were shown to be more sensitive to heavy metal than cells mixed with Na-alginate or immobilized on Sr-alginate. However, the linear regression curves were derived from the Sr-alginate immobilized cells indicating the immobilization method is a useful tool for monitoring of heavy metal under more stable condition of bioluminescence.

  • PDF

An Efficient Algorithm for Monitoring Continuous Top-k Queries (연속 Top-k 질의 모니터링을 위한 효율적인 알고리즘)

  • Jang, JaeHee;Jung, HaRim;Kim, YougHee;Kim, Ung-Mo
    • Journal of KIISE
    • /
    • v.43 no.5
    • /
    • pp.590-595
    • /
    • 2016
  • In this study, we propose an efficient method for monitoring continuous top-k queries. In contrast to the conventional top-k queries, the presented top-k query considers both spatial and non-spatial attributes. We proposed a novel main-memory based grid access method, called Bit-Vector Grid Index (BVGI). The proposed method quickly identifies whether the moving objects are included in some of the grid cell by encoding a non-spatial attribute value of the moving object to bit-vector. Experimental simulations demonstrate that the proposed method is several times faster than the previous method and uses considerably less memory.

A Study on Output Monitoring of Green Roof Integrated PV System through Surface Temperature Algorithm (표면온도 알고리즘을 통한 옥상녹화통합형 태양광시스템의 출력 모니터링 연구)

  • Kim, Tae-Han;Park, Sang-Yeon
    • KIEAE Journal
    • /
    • v.15 no.1
    • /
    • pp.89-95
    • /
    • 2015
  • The centralized power supply system and rainwater treatment system, which are major infrastructure in modern cities, are showing their limitations in accommodating environment load due to climate changes that has aggravated recently. As a result, complex issues such as shortage of reserve power and urban flooding have emerged. As a single solution, decentralized systems such as a model integrating photovoltaic system and rooftop greening system are suggested. When these two systems are integrated and applied together, the synergy effect is expected as the rooftop greening has an effect of preventing urban flooding by controlling peak outflow and also reduces ambient temperature and thus the surface temperature of solar cells is lowered and power generation efficiency is improved. This study aims to compare and analyze the monitoring results of four algorithms that define correlations between micro-climate variables around rooftop greening and the surface temperature of solar cells and generate their significance. By doing so, this study seeks to present an effective algorithm that can estimate the surface temperature of solar cell that has direct impact on the efficiency of photovoltaic power generation by observing climate variables.

Implementation and evaluation of the BCG measurement system for non-constrained health monitoring (무구속 건강모니터링을 위한 심탄도 계측 시스템 구현 및 평가)

  • Noh, Yun-Hong;Jeong, Do-Un
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.1
    • /
    • pp.8-16
    • /
    • 2010
  • This research proposes measuring of BCG(ballistocardiogram) to monitor heart activities in a non-constrained environment, at home or work. Unlike with ECG, measuring BCG does not require the attachment of leads on the subject's body and allows signal measuring in a non-constrained state. It enables effective long-term monitoring of cardiac conditions. In this study a chair type BCG measurement system to continuous monitor the activity of the heart is implemented. The instrument consists of upper petal and ready for press of chair load cell sensor is attached to measure the change of the object's weight. In order to extract the output ballistic signal from the weight and force sensor signals. Beside the signal processing circuit for the digital conversion, the ballistic signal is detected using DAQ equipment. Signal processing algorithm including wavelet transforms for noise cancellation, template matching for normalization and peak detection in BCG is developed. ECG and BCG were concurrently measured to evaluate the performance of the system, and comparing the characteristics of the two signals verified the possibility of the system in non-constrained and nonconscious health monitoring.

Lab-on-a-Chip for Monitoring the Quality of Raw Milk

  • Choi Jeong-Woo;Kim Young-Kee;Kim Hee-Joo;Lee Woo-Chang;Seong Gi-Hun
    • Journal of Microbiology and Biotechnology
    • /
    • v.16 no.8
    • /
    • pp.1229-1235
    • /
    • 2006
  • A lab-on-a-chip (LoC) was designed for simultaneous monitoring of microorganisms, antibiotic residues, somatic cells, and pH in raw milk. The LoC was fabricated from polydimethylsiloxane (PDMS) using microelectromechanical system (MEMS) technology, which consisted of two parts; a protein array and microchannel. The protein array was fabricated by immobilizing five types of antibodies corresponding to two microorganisms, two antibiotic residues, and somatic cells. A sol-gel film was deposited on a glass substrate to immobilize the antibodies. The target analytes in raw milk could be bound with the corresponding antibody by an immunoreaction, and the antigen-antibody complex was detected using fluorescence microscopy. SNARF-dextran was used as a pH indicator, and the SNARF-entrapped hydrogel was attached to the microchannel in the chip. After injecting the milk sample into the channel, the pH was measured by monitoring the change in fluorescence intensity by fluorescence microscopy. The on-chip simultaneous assay of two microorganisms (E. coli O157:H7 and Streptococcus agalactiae), two antibiotic residues (penicillin G and dihydrostreptomycin), and neutrophils was successfully accomplished using the proposed LoC system.