• Title/Summary/Keyword: cell alignment

Search Result 321, Processing Time 0.028 seconds

A Study on Electro-optical Characteristics of the UV Aligned FFS Cell on the Organic Layer

  • Han, Jeong-Min;Ok, Chul-Ho;Hwang, Jeoung-Yeon;Kim, Byoung-Yong;Kang, Dong-Hun;Kim, Jong-Hwan;Kim, Young-Hwan;Han, Jin-Woo;Lee, Sang-Keuk;Seo, Dae-Shik
    • Transactions on Electrical and Electronic Materials
    • /
    • v.8 no.3
    • /
    • pp.135-138
    • /
    • 2007
  • In this study, we investigated the electro-optical (EO) characteristic of fringe-field switching (FFS) mode cell by the two kinds of ultraviolet (UV) alignment method on the organic thin film (polyimide: PI). The suitable organic layers for FFS cell and the aligning capabilities of nematic liquid crystal (NLC) using the in-situ photoalignment method were studied; Disclination is observed after conventional photoalignment method for 1h, and in-situ photoalignment method for 1h. Monodomain alignment of the NLC can be observed via insitu photo alignment method for 2 h and 3 h. It is considered that NLC alignment is due to photo-depolymerization of the polymer with oblique non-polarized UV irradiation on PI surface. An unstable V-T curve of UV-aligned FFS-LCD with conventional photoalignment method can be achieved. However, a stable V-T curve of UV-aligned FFS-LCD with in-situ photoalignment method (1 h), and V-T curve of UV-aligned FFS-LCD with in-situ photo alignment method was much stable comparing with that of other UV-aligned FFSLCD's. As a result, more stable EO performance of UV-aligned FFS-LCD with in-situ photoalignment method for 3h is obtained than that of the other UV-aligned FFS-LCD's.

Reflective Liquid Crystal Cell Parameters Measurement

  • Valyukh, S.;Valyukh, I.;Adas, C.;Chigrinov, V.;Skarp, K.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.479-482
    • /
    • 2004
  • We report a method for simultaneous measurements of cell gap, twist angle, birefringence dispersion of liquid crystal (LC) material and alignment directions in filled reflective LC cells. The method is based on spectral measurements of the LC cell reflectivity for three orientations ($0^{\circ},45^{\circ},90^{\circ}$) of the exit polarizer and may be applied for LC cells with low and high gaps.

  • PDF

Birefringence effect of two directionally rubbed liquid crystal cells

  • Huang, Chi Yen;Huang, Yao Sheng;Tian, Jing Rui
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.446-449
    • /
    • 2005
  • The alignment property of liquid crystals on the two-easy axes substrate is investigated. The two-easy axes substrate frustrates the orientation of the LCs next to the substrate, and hence influences the birefringence of the LC cell. Experimental findings reveal that the ratio of the rubbing strengths in the different rubbing directions and the cell thickness substantially influence the birefringence of the LC cell. The surface anchoring energetic competition between the different rubbing directions contributes to the observed results.

  • PDF

Photoalignment of Liquid Crystal on Silicon Microdisplay

  • Zhang, Baolong;Li, K. K.;Huang, H. C.;Chigrinov, V.;Kwok, H. S.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.295-298
    • /
    • 2003
  • Reflective mode liquid crystal on silicon (LCoS) microdisplay is the major technology that can produce extremely high-resolution displays. A very large number of pixels can be packed onto the CMOS circuit with integrated drivers that can be projected to any size screen. Large size direct-view thin film transistor (TFT) LCDs becomes very difficult to make and to drive as the information content increases. However, the existing LC alignment technology for the LCoS cell fabrication is still the mechanical rubbing method, which is prone to have minor defects that are not visible normally but can be detrimental if projected to a large screen. In this paper, application of photo-alignment to LCoS fabrication is presented. The alignment is done by three-step exposure process. A MTN $90^{\circ}$ mode is chose as to evaluate the performance of this technique. The comparison with rubbing mode shows the performance of photo-alignment is comparable and even better in some aspect, such as sharper RVC curve and higher contrast ratio.

  • PDF

Fabrication and characterization of aligned crossply PHBV fibrous mat

  • Kim, Yang-Hee;Yang, Hun-Mo;Song, Ho-Yeon;Lee, Byong-Taek
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2010.05a
    • /
    • pp.44.1-44.1
    • /
    • 2010
  • poly(3-hydroxybutyrate-co-3-hydroxyvalerate) (PHBV) is a bacterially derived copolymer produced by fermentation. PHBV has been attractive because of its potential environmental, pharmaceutical and biomedical applications. Recently, the electrospinning technique has been used to fabricate fibrous mat for biomedical applications such as artificial blood vessel, drug release and scaffolds, because this method is simple and easy to get ultrafine polymer fibers. Depending on speed of rotation drum collector, fiber structure was different. In this work, PHBV fiber was aligned by electrospinnning machine. Furthermore, alignment of PHBV fiber mats was given angle such as $45^{\circ}$, $60^{\circ}$ and $90^{\circ}$. The morphology of each aligned PHBV fiber mat was observed by SEM technique. The mechanical property was evaluated depending on alignment angle. Especially, cell attachment ability depending on alignment of PHBV fiber mats was carried out using MG- 63 osteoblast like cells.

  • PDF

Study on the LC Alignment on Vertical Alignment Polymer Surface using the AFM (AFM을 이용한 수직배향막 폴리머 표면위의 액정배향에 관한 연구)

  • 김완철;송선애;전일철;이종문;이승희
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.6
    • /
    • pp.510-514
    • /
    • 2003
  • We have studied the alignment of liquid crystals (LCs) on homeotropic polymeric surface that is scanned using an atomic force microscope (AFM) tip by optical polarizing microscopy and computer simulation. The scanned areas on one substrate are 5 $\mu\textrm{m}$ ${\times}$ 5 $\mu\textrm{m}$, 10 $\mu\textrm{m}$ ${\times}$ 10 $\mu\textrm{m}$, and 20 $\mu\textrm{m}$ ${\times}$ 20 $\mu\textrm{m}$ and this substrate is assembled to another substrate coated. with homeotropic polymer. The fabricated micro-LC cell using two substrates does not show any hysteresis and disclination lines inside the nano-rubbing areas, while changing voltage up and down. This indicates that the pretilt angle exists in the areas, thereby forming a hybrid LC configuration. From the experimental and computer simulation results, we can understand that the AFM rubbing clearly changes surface status of homeotropic alignment layer and causes the pretilt angle to an initial scanning direction.

Alignment of Microbeads Using Spinning Helical Minichannel Cartridge (회전하는 나선형 미니채널 카트리지를 이용한 미세입자 정렬)

  • Kim, Subin;Prasad, Bibin;Kim, Jung Kyung
    • Journal of the Korean Society of Visualization
    • /
    • v.14 no.3
    • /
    • pp.38-45
    • /
    • 2016
  • Separation of particles based on different sizes, detection of pathogenic bacteria and isolation of leukocytes from whole blood are typical applications of spiral or helical microchannels. The present study focuses on developing a CD4+ T-cell counting device for monitoring HIV/AIDS patients with the aid of a helical minichannel used for a sample cartridge. For the experiment, $10{\mu}m$ sized microbeads were used for visualization with a fluorescence imaging system. Alignment of microbeads was investigated in a stationary and spinning sample cartridge filled with glycerol-water mixtures of different densities. The helical minichannel was spun using a DC motor controlled by an Arduino board with a Bluetooth shield. It was found that when the sample cartridge was made stationary, no bead alignment was achieved for a medium with density (0% and 20% glycerol) lower than that of the beads, but when it was spun at 2000-3000 rpm for 1-4 min, an alignment was obtained at the top of the channel facilitating optical detection and enumeration of those microbeads. Since an alignment of microbeads was achieved for a medium with density as that of blood plasma, the same approach can be applied for aligning and counting CD4+ T-lymphocytes in whole blood samples collected from patients.

Liquid Crystal Alignment Stability of Polyvinylcinnamate Photonslignment Layer (Polyvinylcinnamate 광배향막의 액정 배향 안정성)

  • Lim Ji-Chul;Choi Sie-Hyung;Kim Whanki;Kim Sung Soo;Song Kigook
    • Polymer(Korea)
    • /
    • v.29 no.4
    • /
    • pp.413-417
    • /
    • 2005
  • Orientations of liquid crystal molecules on a surface of a film of photoreactive polyvinylcinnamate were investigated in order to apply as an alignment layer of LCD. When the polyvinylcinnamate film was exposed to linearly polarized W light, optical anisotropy was induced in the film through a selective photoreaction. Liquid crystal molecules on a surface of the film was aligned along the oriented polymer chain direction through intermolecular interactions. Thermal and light stability of the photoaligned LC cell were studied by investigating LC alignment changes after the alignment layer was treated with heat and W light. When the film was exposed with linearly polarized UV several times, the LC alignment was induced only along the final UV exposure direction.

The effect of pretilt angle on viewing angle in In-Plane switching mode LCD

  • Kang, Dong-Jin;Gwag, Jin-Seog;Park, Kyoung-Ho;Yoon, Tae-Hoon;Kim, Jae-Chang;Lee, Gi-Dong;Kim, Hee;Cho, Seong-Jin
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.559-562
    • /
    • 2003
  • The effect of pretilt angle on viewing characteristics of an IPS cell is discussed. We calculated optical viewing angle in the IPS cell as function of pretilt angle from $0.5^{\circ}$ to $4^{\circ}$, so that we could confirm that low pretilt angle was profitable for wider viewing property. In order to verify the calculation, we made an IPS cell with very low pretilt angle by the alignment method using ion beam exposure. In the experiment, we confirmed that wider viewing characteristics can be achieved if lower pretilt angle was applied in IPS mode. And Ion beam alignment method was useful for low pretilt creation.

  • PDF

An improved electrode structure of the Patterned Vertical Aligned Liquid Crystal Cell for high transmittance (새로운 전극구조를 통한 수직배향 액정 셀의 투과특성 향상)

  • Choi, Yong-Hyun;Son, Jung-Hee;Lee, Gi-Dong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.9
    • /
    • pp.1724-1728
    • /
    • 2007
  • In this paper we propose a novel electrode structure for high transmittance in the Patterned Vertical Alignment (PVA) LC cell. We use the 'TechWiz LCD' for calculation of the director configuration and optical characteristics. We studied the area decreasing the transmittance through the electrode structure for wide viewing angle and proposed new electrode design to change LC director configuration in the area. We show the comparison of the calculated optical transmittance between the conventional PVA mode and the proposed PVA mode. From the results, we confirm that the optical transmittance of the proposed structure of the PVA cell becomes higher.