• Title/Summary/Keyword: ceiling material

Search Result 97, Processing Time 0.02 seconds

Charcoal Properties and Temperature Change of a Kiln's Inner and Outer Walls in Carbonization Process Using an Improved Kiln (개량형탄화로를 이용한 제탄과정 중 탄화로 내·외벽 온도변화 및 목탄 특성)

  • Kwon, Gu-Joong;Kwon, Sung-Min;Jang, Jae-Hyuk;Hwang, Won-Joung;Kim, Nam-Hun
    • Journal of the Korean Wood Science and Technology
    • /
    • v.39 no.3
    • /
    • pp.230-237
    • /
    • 2011
  • The study was performed to investigate the characteristics of charcoal and temperature change of a kiln's inner and outer walls in carbonization process using improved kiln. In this kiln system, carbonization process was completed in eight days. In the kiln, the ignition temperature was kept about $720^{\circ}C$. And then the temperature were increased gradually prior to be refined. Finally, the temperature in refining process was reached to maximum point, $1,000^{\circ}C$. In the chimney, the temperature was increased gradually from $90^{\circ}C$ at ignition to $750^{\circ}C$ at refining. The temperature change of the kiln wall resembles a temperature change progress curve during a carbonization process. The highest temperature of the kiln wall that appeared by a carbonization process was around $500^{\circ}C$. As a result of having measured an inner wall and the outer wall of the kiln using an infrared thermography camera, it was judged with there being considerable latent heat on kiln wall and ceiling. Fixed carbon contented of charcoal was 85.9~89.9%. Refining degree of charcoal, hardness, calorific value and pH were l, 12, 7,047~7,456 kcal/kg, 9.0~9.9, respectively. The yield of wood charcoal was 13.8%, and compared to conventional kiln's yield increased 1.5%.

A Study on the Characteristics of Bonding Strength by Types of Repair Materials by Mechanical Pressurizing Equipment(MPE) (기계식 가압장비(MPE)에 의한 보수재 종류별 부착강도 특성에 관한 연구)

  • Yu, Hyeong-Sik;Chung, Jee-Seung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.2
    • /
    • pp.553-560
    • /
    • 2020
  • In the existing research paper, we developed Mechanical Pressurizing Equipment(MPE) that can apply a certain amount of pressure and found out about improving the bonding strength of repair materials constructed in the repair section, and if pressurized, the bonding strength could be increased. In this study, the pressure of Mechanical Pressurizing Equipment(MPE) was changed to 0, 10, 30, 50, and 80 kPa, and the test was conducted to select effective pressure by measuring the flexural, compressive, and bonding strength of the specimens and deformation of the pressure plate at the age of 3 and 28th days. As a result of the test, 30 kPa was the most efficient pressure for the MPE. After producing the specimen with three types of repair materials with different main components, the bonding strength was measured according to dry and wet conditions, construction site (ceiling, wall and floor), and whether or not pressurized, on the 3rd, 7th, 14th, and 28th, indicating that the repair materials mixed with cellulose fiber was most effective for the MPE.

Guidelines for dental clinic infection prevention during COVID-19 pandemic (코로나 바이러스 대유행에 따른 치과 의료 관리 가이드라인)

  • Kim, Jin
    • Journal of Korean Academy of Dental Administration
    • /
    • v.8 no.1
    • /
    • pp.1-7
    • /
    • 2020
  • Dental settings have unique characteristics that warrant specific infection control considerations, including (1) prioritizing the most critical dental services and provide care in a way that minimizes harm to patients due to delayed care, or harm to personnel from potential exposure to persons infected with the COVID-19 disease, and (2) proactively communicate to both personnel and patients the need for them to stay at home if sick. For health care, an interim infection prevention and control recommendation (COVID-19) is recommended for patients suspected of having coronavirus or those whose status has been confirmed. SARS-CoV-2, which is the virus that causes COVID-19, is thought to be spread primarily between people who are in close contact with one another (within 6 feet) through respiratory droplets that are produced when an infected person coughs, sneezes, or talks. Airborne transmission from person-to-person over long distances is unlikely. However, COVID-19 is a new disease, and there remain uncertainties about its mode of spreads and the severity of illness it causes. The virus has been shown to persist in aerosols for several hours, and on some surfaces for days under laboratory conditions. COVID-19 may also be spread by people who are asymptomatic. The practice of dentistry involves the use of rotary dental and surgical instruments, such as handpieces or ultrasonic scalers, and air-water syringes. These instruments create a visible spray that can contain particle droplets of water, saliva, blood, microorganisms, and other debris. While KF 94 masks protect the mucous membranes of the mouth and nose from droplet spatter, they do not provide complete protection against the inhalation of airborne infectious agents. If the patient is afebrile (temperature <100.4°F)* and otherwise without symptoms consistent with COVID-19, then dental care may be provided using appropriate engineering and administrative controls, work practices, and infection control considerations. It is necessary to provide supplies for respiratory hygiene and cough etiquette, including alcohol-based hand rub (ABHR) with 60%~95% alcohol, tissues, and no-touch receptacles for disposal, at healthcare facility entrances, waiting rooms, and patient check-ins. There is also the need to install physical barriers (e.g., glass or plastic windows) in reception areas to limit close contact between triage personnel and potentially infectious patients. Ideally, dental treatment should be provided in individual rooms whenever possible, with a spacing of at least 6 feet between the patient chairs. Further, the use of easy-to-clean floor-to-ceiling barriers will enhance the effectiveness of portable HEPA air filtration systems. Before and after all patient contact, contact with potentially infectious material, and before putting on and after removing personal protective equipment, including gloves, hand hygiene after removal is particularly important to remove any pathogens that may have been transferred to the bare hands during the removal process. ABHR with 60~95% alcohol is to be used, or hands should be washed with soap and water for at least 20 s.

Development of Real-Time Scheduling System for OHT Mission Planning (OHT 작업 계획을 위한 실시간 스케줄링 시스템 개발)

  • Lee, Bok-Ju;Park, Hee-Mun;Kwon, Yong-Hwan;Han, Kyung-Ah;Seo, Kyung-Min
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.10 no.7
    • /
    • pp.205-214
    • /
    • 2021
  • For smart manufacturing, most semiconductor sites utilize automated material handling systems(AMHS). As one of the AMHSs, the OHT control system(OCS) manages overhead hoist transports(OHT) that move along rails installed on the ceiling. This paper proposes a real-time scheduling system to efficiently allocate and control the OHTs in semiconductor logistics processes. The proposed system, as an independent subsystem within the OCS, is interconnected with the main subsystem of the OCS, so that it can be easily modified without the effect of other systems. To develop the system, we first identify the functional requirements of the semiconductor logistics process and classify several types of control scenarios of the OHTs. Next, based on SEMI(Semiconductor Equipment and Materials International) standard, we design sequence diagrams and interface messages between the subsystems. The developed system is interoperated with the OCS main subsystem and the database in real time and performs two major roles: 1) OHT dispatching and 2) pathfinding. Six integrated tests were carried out to verify the functions of the developed system. The system was normally operated on six basic scenarios and two exception scenarios and we proved that it is suitable for the mission planning of the OHTs.

A Study of Color Scheme on Coastal Passenger Ship Seafarer's Workspace (연안여객선 선원의 작업공간 색채계획에 관한 연구)

  • Jin Park
    • Journal of Navigation and Port Research
    • /
    • v.48 no.3
    • /
    • pp.221-231
    • /
    • 2024
  • The aim of this study was to enhance the safety and care of mental health for seafarer working in passenger ship workspaces. Brightness, color values, and color distribution were investigated with issues and improvement ways identified through seafarers' interviews. Firstly, previous studies, references, current policy, regulations, and accident case studies were reviewed. Color compositions of wheelhouse and engine room of M Ship were then surveyed in the field. Color values of each space were analyzed using a colorimeter. Colormeter analysis of brightness and color measurements in the wheelhouse and engine areas indicated that ceilings, walls, and floors were generally dark, with the engine area being very dark. Regarding color, green and blue were distributed in the ceiling of the wheelhouse and engine area, while red and blue were in the walls and floors of the wheelhouse and engine area. According to interviews with seafarers currently working at engine rooms, they responded about their experience of near miss incidents due to a decrepit indoor environment, a dark working environment, slippery and bright flooring, and stairs that were not suitable for domestic users. Thus, when installing lighting in the future, the brightness of the space should be improved by distinguishing between night and day. A lighting plan considering the location of lighting, level of shadow formation and contrast, reflectance of the facility, glare, color of light, floor color plan, and material selection is needed. A facility design suitable for domestic users is also needed.

External Exposure Due to Natural Radionuclides in Building Materials in Korean Dwellings (건축자재내 포함된 천연방사성핵종에 의한 실내 공간의 방사선량 평가)

  • Cho, Yoon Hae;Kim, Chang Jong;Yun, Ju Yong;Cho, Dae-Hyung;Kim, Kwang Pyo
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.4
    • /
    • pp.181-190
    • /
    • 2012
  • Naturally occurring radioactive materials (NORM) in building materials are main sources of external radiation exposure to the general public. The objective of this study was to assess external radiation dose in Korean dwellings due to NORM in concrete walls. Reference room model for dose assessment was made by analyzing room structure and housing scale of Korean dwellings. In addition, dose assessments were made for varying room sizes. Absorbed doses to air and effective dose rates were calculated using radiation transport code MCNPX. Assuming a reference room of $3{\times}4{\times}2.8m^3$, absorbed dose rates in air were 0.80, 0.97, 0.08 nGy $h^{-1}$ per Bq $kg^{-1}$ for uranium series, thorium series, and $^{40}K$, respectively. Effective dose rates were 0.57, 0.69, 0.058 nSv $h^{-1}$ per Bq $kg^{-1}$, respectively. Radiation dose resulting from concrete of ceiling and floor increased with room area while radiation dose from concrete of walls decreased with room area. Therefore, total radiation doses were almost the same for the varying room area from 5 to $30m^2$. Effective dose in Korean dwellings was calculated based on measurement data of NORM concentration in concrete and occupancy fraction of Korean population by location. Annual effective dose was 0.59 mSv assuming that indoor occupancy fraction was 0.89 and concentrations of uranium series, thorium series and $^{40}K$ were 26, 39, 596 Bq $kg^{-1}$, respectively. Finally, annual effective dose in Korean dwellings can be calculated by the following equation: Effective dose=indoor occupancy fraction${\times}8760\;h\;y^{-1}{\times}(0.57C_U+0.69C_{Th}+0.058C_K)$.

Field Survey on the Maintenance Status of Greenhouses in Korea (온실의 유지관리 실태조사 분석)

  • Choi, Man Kwon;Yun, Sung Wook;Kim, Hyeon Tae;Lee, Si Young;Yoon, Yong Cheol
    • Journal of Bio-Environment Control
    • /
    • v.23 no.2
    • /
    • pp.148-157
    • /
    • 2014
  • The purpose of this study was to investigate greenhouse maintenance by farms by looking into greenhouses across the nation for greenhouse specification, disaster-resistance greenhouse construction, types and degree of damage due to natural disasters, pre-inspection in case of typhoon or heavy snow forecast, and fire-fighting facilities to prevent a fire. The findings were summarized as follows: as for greenhouse specification, the highest proportion of them were 90 m or longer both in single- and multi-span greenhouses in terms of length; 8 m or wider and 7.0~7.9 m in single- and multi-span greenhouses, respectively, in terms of width; 1.5~1.9 m and 2.0~2.9 m in single-and multi-span greenhouses, respectively, in terms of height; and 3.0~3.9 m and 6 m in single- and multi-span greenhouses, respectively, in terms of diameter. As for disaster-resistance greenhouses, farmers were reluctant to install such greenhouses. The low distribution of disaster-resistance greenhouses was attributed to the greenhouses built dependent on the old practice, the greenhouses already completed, and relatively high construction costs. As for damage by natural disasters, greenhouses were subject to more damage by typhoons than heavy snow. They mainly inspected the ceiling and side windows, entrances, and fixation bands for covering materials in case of typhoon forecast and the heating devices in case of heavy snow forecast. As for repair methods for greenhouse pipe corrosion, they preferred partial replacement to painting and did not use stiffeners for structures to prevent a natural disaster in most cases. As for the maintenance of greenhouse covering materials, most farmers inspected their sealing property but did not clean the coverings for light transmission. The destruction of structural materials can be prevented by eliminating greenhouse covering materials during a typhoon, but they were not able to do so because of the covering material replacement costs and the crops they were growing. The study also examined whether greenhouse farms had fire-fighting facilities to prevent a fire and found that they lacked the perception of greenhouse fire prevention to a great degree.