• Title/Summary/Keyword: cavity volume

Search Result 328, Processing Time 0.026 seconds

Development of Die Design System for Turbine Blade Forging (터빈 블레이드의 형단조 금형설계의 자동화에 관한 연구)

  • 최병욱;조종래;왕지석;김동권;김동영
    • Transactions of Materials Processing
    • /
    • v.8 no.6
    • /
    • pp.569-575
    • /
    • 1999
  • Computer programs have been developed to design the forging dies of turbine and compressor blades. The design of forging dies is based the side force and the filling of die cavity. In this study, slab method has been applied to simulate forging processes numerically. the program composed of Visual Basic also provides the informations of mean stress, total forging load, distribution of temperature, position of neutral line, total volume and volume of flash in the final stage to users. The preform position is predicted by the reverse slab method. The program has been successfully applied to various types of turbine blades.

  • PDF

Computer Simulation on the Correlations between the Microwave Quality factor and the Pores inside the Dielectrics (마이크로파 유전체의 내부 기공과 마이크로파 품질계수의 상관관계에 대한 컴퓨터 시뮬레이션)

  • 박재환
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.4
    • /
    • pp.311-316
    • /
    • 2003
  • Effects of pores on the microwave properties in microwave dielectric ceramics were studied by a computer simulation. Scattering matrix S$\_$21/ obtained from the network analyzer was compared to the S$\_$21/ obtained from the simulation. From electric field distribution, the dominant resonant TE$\_$01$\delta$/ mode could be easily determined. The effects of the porosity and pore size inside the dielectrics on the microwave properties were investigated by the HFSS simulation. When the total pore volume remains constantly, the quality factor decreased as the pore size Increases. As the total pore volume of the dielectrics increased. quality factor decreased.

Analysis of Beam Quality of the Unsymmetric Nd : YAG Laser with Unstable Resonator (비대칭 구조로 이루어진 불안정 공진기형 Nd : YAG 레이저의 빔질 분석)

  • Kim, Hyun-Su
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.5
    • /
    • pp.456-461
    • /
    • 2005
  • We numerically investigate the characteristic of single Nd:YAG rod laser with the convex-plane resonator configuration in order to get the best condition for high efficient intra-cavity second harmonic generation(SHG). The beam quality is analyzed with ABCD matrixes including the thermal lensing characteristic of Nd:YAG rod. The analysis is focused on stability, M2, beam waist and mode-volume of laser beam inside the resonator. The best conditions for SHG is obtained when a laser rod is set near the curved laser mirror.

Inferior Blow-Out Fracture Reduction Using Two Urinary Balloon Catheters

  • Jo, Eun Jun;Kim, Jong Hwan;Yang, Ho Jik
    • Archives of Craniofacial Surgery
    • /
    • v.16 no.3
    • /
    • pp.114-118
    • /
    • 2015
  • Background: The reduction of orbital blowout fracture primarily aims to normalize the extra-ocular movement by returning the herniated orbital soft tissue into the original position, and to prevent enophthalmos by normalizing the orbital cavity volume. We introduce a balloon catheter-assisted orbital floor reduction technique. Methods: A retrospective review was performed for all patients with orbital floor fracture who underwent the technique described in the main body of this text. Medical records were reviewed for demographic data, clinical presentation and course, degree of enophthalmos, intraorbital volume on computed tomography scan, and postoperative outcomes. The enophthalmos and intraorbital volume of the injured site were compared to the uninjured eye and orbit. Results: The review identified 14 patients (11 male, 3 female). The mean preoperative difference in en-exopthalmos was 2.13 mm, while the mean orbital volume was 116%. The mean postoperative difference in en-exophthalmos had improved to 0.61 mm with a mean orbital volume of 101.85%. At the time of catheter removal at 10 days, three patients experienced diplopia (n=1), extra-ocular movement disorder (1), or enophthalmos (1). All of these had resolved by the 6-month follow-up visit. Conclusion: Balloon catheter-assisted reduction of the orbital floor fractures was associated with improvements in intraorbital volume and enopthalmos in the 14 patients. Notable complications included diplopia, enophthalmos, and limited extra-ocular movement, all of which were transient in the early postoperative period and had resolved by 6-month follow up.

Effects of vasopressin administration in the oral cavity on cardiac function and hemodynamics in rats

  • Fukami, Hayato;Sunada, Katsuhisa
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.22 no.1
    • /
    • pp.11-18
    • /
    • 2022
  • Background: The vasoconstrictive effect of epinephrine in local anesthetics affects the heart, which leads to hesitation among dentists in injecting local anesthetics into patients with cardiovascular disease. Due to its vasoconstrictive effects, the present study investigated the effects of vasopressin administration on cardiac function in rats. Methods: Experiment 1 aimed to determine the vasopressin concentration that could affect cardiac function. An arterial catheter was inserted into the male Wistar rats. Next, 0.03, 0.3, and 3.0 U/mL arginine vasopressin (AVP) (0.03V, 0.3V, and 3.0V) was injected into the tongue, and the blood pressure was measured. The control group received normal saline only. In Experiment 2, following anesthesia infiltration, a pressure-volume catheter was placed in the left ventricle. Baseline values of end-systolic elastance, end-diastolic volume, end-systolic pressure, stroke work, stroke volume, and end-systolic elastance were recorded. Next, normal saline and 3.0V AVP were injected into the tongue to measure their effect on hemodynamic and cardiac function. Results: After 3.0V administration, systolic blood pressures at 10 and 15 min were higher than those of the control group; they increased at 10 min compared with those at baseline. The diastolic blood pressures at 5-15 min were higher than those of the control group; they increased at 5 and 10 min compared with those at baseline. The preload decreased at 5 and 10 min compared to that at baseline. However, the afterload increased from 5 to 15 min compared with that of the control group; it increased at 10 min compared with that at baseline. Stroke volume decreased at 10 and 15 min compared with that of the control group; it decreased from 5 to 15 min compared with that at baseline. Stroke work decreased from 5 to 15 min compared with that of the control group; it decreased from 5 to 15 min compared with that at baseline. Conclusion: Our results showed that 3.0 U/mL concentration of vasopressin resulted in increased blood pressure, decreased stroke volume and stoke work, decreased preload and increased afterload, without any effect on myocardial contractility.

Effect of local anesthesia on pulpal blood flow in mechanically stimulated teeth (기계적으로 자극 받은 치아에서 국소마취가 치수혈류에 미치는 효과)

  • Chu Wan-Sik;Park Seung-Chu;Ahn Dong-Kuk;Kim Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.4
    • /
    • pp.257-262
    • /
    • 2006
  • The aims of the study were to evaluate the effect of epinephrine-containing local anesthetics on pulpal blood flow (PBF) and to investigate its effect on cavity preparation-induced PBF change. PBF was recorded using a laser Doppler flowmeter (Perimed Co., Sweden) from canines of nine cats under general anesthesia before and after injection of local anesthetics and after cavity preparation. 2% lidocaine hydrochloride with 1 : 100,000 epinephrine was administered by local infiltration given apical to the mandibular canine at the vestibular area and the same volume of isotonic saline was injected on the contralateral tooth as a control. A round carbide bur was operated at slow speed with isotonic saline flushing to grind spherical cavities with increasing depth through the enamel and into the dentin on both teeth. The obtained data was analyzed with paired t-test. Cavity preparation caused significant increase of PBF (n = 9, p < 0.05). Local infiltration of lidocaine with epinephrine resulted in decreases of PBF (n = 9, p < 0.05), whereas there was no significant change of PBF with the physiologic saline as a control. Cavity preparation on tooth anesthetized with lidocaine with epinephrine caused significantly less increase of PBF than in control tooth (p < 0.05). Therefore, the result of the present study demonstrates that local infiltration of 2% lidocaine with 1 : 100,000 epinephrine effectively reduces PBF increase caused by cavity preparation.

Studies on the Adsorbents for Cigarette Filter I. Effect of Pore Voume Distribution and Specific Area of Adsorbents on the Removal Efficiency of Smoke Components by Triple Filter (담배필터용 흡착제에 관한 연구 제1보. 흡착제의 종류와 동공특성이 담배연기성분 제거능에 미치는 영향)

  • 박태무;이영택;김성한;오영일
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.10 no.1
    • /
    • pp.75-82
    • /
    • 1988
  • Cigarettes were made using a triple filter with several porous materials in its cavity. The removal effect of the adsorbents on carbon monoxide and hydrogen cyanide in cigarette smoke was investigated with the variation of their surface area and pore volume distributions. Several attempts were made to activated coconut shell based char under the fixed steam purging rate. 1. The specific surface area increased in number of micropore. It was found for transitional pore to have a little effect on the total surface area. 2. A Small amount of the particulate matter adsorbed on the adsorbents with transitional pores, Zeolite showed a little effect on the carbon monoxide adsorption though its small pore volume, but there was no significant difference in the adsorption capacity zeolite and the others. 3. In the adsorption for hydrogen cyanide as a vapor phase in cigarette smoke, the adsorption effect of the adsorbents increased remarkably with increasing their surface area and number of micropore. It was considered that the adsorbents with small pore volume like molecular seive 4A, in which the capillary diffusion of adsorbates could not be able, would not be effective for the adsorption of hydrogen cyanide.

  • PDF

Regional Gray Matter Volume Reduction Associated with Major Depressive Disorder: A Voxel-Based Morphometry

  • Tae, Woo-Suk
    • Investigative Magnetic Resonance Imaging
    • /
    • v.19 no.1
    • /
    • pp.10-18
    • /
    • 2015
  • Background and Purpose: The association between the low emotional regulation and the brain structural change of major depressive disorder (MDD) has been proposed, but the voxel-based morphometry (VBM) studies on female MDD are rare. The purpose of the present study was to show the regional volume changes of gray matter (GM) in female patients with MDD by optimized VBM. Methods: To control subjects homogeneity, twenty female MDD patients and age, sex matched 21 normal controls were included for the VBM analysis. To identify the change of regional gray matter volume (GMV), the optimized VBM was performed with T1 MRIs. The amounts of gray/white matter and intracranial cavity volumes (ICV) were measured. The analysis of covariance (ANCOVA) and partial correlation analyses covariate with age and ICV were applied for VBM. Results: The age and ICV distributions were similar between the two groups. In the ANCOVA, the total GMV of MDD was smaller than that of normal controls. In the VBM, regional GMV was relatively decreased in the limbic system (amygdalae, ambient gyri, hippocampi heads, subiculum, posterior parahippocampal gyri, pulvinar nuclei, dorsal posterior cingulate gyri, and left pregenual cingulate gyrus). The lingual gyri, short insular gyri, right fusiform gyrus, and right inferior frontal gyrus were also showed decreased regional GMV. Conclusion: The results of this study indicate that the female MDD is mainly associated with the structural deficits of the limbic system and limbic system related cortices, which were known to the center of emotions.

Exogenous-Water-Induced Thermal and Mechanical Effects on Dental Hard Tissue by the Er:YAG Laser: Free-running Mode (외부의 물과 Er:YAG Laser의 작용에 의한 Dental Hard Tissue에서의 열과 역학적 효과: Free-running 방식)

  • Kwon, Y.H.;Frederickson, C.J.;Motamedi, M.;Rastegar, S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.380-384
    • /
    • 1997
  • This study was performed to understand the exogenous-water-drop induced thermomechanical effect on the tooth in the free-running Er:YAG laser mode for the proper use of water as a laser energy absorber and coolant in dentistry. The ree-running Er:YAG laser was used in the dental hard tissue ablation study. A Microjet system was employed to dispense precise water drops. Ablation rate, recoil momentum, and temperature rise in the pulp cavity were measured with and without an exogenous water drop on the tooth surface. Exogenous water enhanced ablation rate in the thick tooth in which the ablation rate on the dry surface does not increase linearly but shows plateau. Optimal exogenous water volume was shifted from 2 nl to 4 nl as the laser energy was increased from 48 mJ to 145 mJ. The magnitude of the recoil momentum was increased as the volume of exogenous water increased. The results of this study suggest that we must pay attention to the recoil momentum or recoil pressure study or the optimal and safe usage of water in the dental treatment because these mechanical effects depend on the volume of exogenous water on the tooth surface.

  • PDF

A Study on the Solar Distillation in a Cube with Tilted Angles (경사진 육면체에서의 태양열에 의한 증발 현상에 대한 연구)

  • Park, Yeong-Hoon;Kim, Byung-Chul
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1424-1429
    • /
    • 2004
  • Distillation is one of many processes that can be used for the purification of water. It requires an energy input such as heat and solar radiation is a possible source of energy. In this process, water is evaporated, thus separating water vapor from the solute. The vapor is then condensed to pure water. The temperature of the water, the cavity of the enclosure and the surface of the glass was measured everyday. Fifteen points were chosen for the temperature measure using a thermocouple. The inner wall and the bottom of each still was painted black for good absorption of heat. The enforced glass was used for the cover for the entering of solar energy. The size of all of the water baths was the same, but the glass of the rectangular form had a tilted angle. In the case of fine or general weather, the volume of condensed water produced by $45^{\circ}$ and $60^{\circ}$ is very irregular compared to that of $15^{\circ}$ and $30^{\circ}$, In case of a rainy day, the occurrence of the volume of condensed water was similar to that of $15^{\circ}$ and $30^{\circ}$, but the volume of condensed water produced by $30^{\circ}$ was the highest.

  • PDF