• Title/Summary/Keyword: cavity filling imbalance

Search Result 43, Processing Time 0.021 seconds

On the new mold structure with multi-point gate for filling-balance mold (사출성형시 불균형 충전에 관한 다구찌 실험계획법을 이용한 성형공정의 최적화)

  • Hong, Youn-Suk;Han, Dong-Hyup;Jeong, Yeong Deug
    • Design & Manufacturing
    • /
    • v.1 no.1
    • /
    • pp.13-16
    • /
    • 2007
  • Almost all injection molds have multi-cavity runner system for mass production, which are designed with geometrically balanced runner system in order to accomplish filling balance between cavity to cavity during processing. However, even though geometrically balanced runner is used, filling imbalance have been observed. Filling imbalance could be decreased by modifying processing conditions such as injections rate, mold temperature, injection pressure, melt temperature that are related to shear, viscosity. In this study, a series of experiment was conducted to investigate filling imbalance variation when modifying runner layout and polymer and to determine which processing condition influences as the primary cause of filling imbalance in geometrically balanced runner system.

  • PDF

Filling Imbalance in 3 Plate Type Injection Molds with Multi-Cavity (다수 캐비티를 갖는 3매 구성형 사출금형에서의 충전 불균형)

  • 제덕근;정영득
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.752-755
    • /
    • 2003
  • Injection molding is the one of the most important processes for mass production of plastic parts. Usually Injection molds for mass production are constituted to multi-cavity runner system to manufacture the more parts at a time. To uniformly fill to each cavity, multi-cavity molds are designed to geometrically balanced runner system. However. in practice this is not the case. The previous studies by Beaumount at.[2] reported that filling imbalance occurred by thermal unbalance on the mold and viscosity variation of resins and so on. In this study, we conducted experiments in order to know the causes or filling imbalance for 3 plate type mold with 8 cavities. We presented a new so called 4BF mold(4plate Type Balanced Filling Mold) to improve filling balance. We conducted a experimental injection molding to verify a efficiency of the 4BF mold. In the results of the experiment, We could confirmed the possibility of the 4BF mold.

  • PDF

Effects of processing Factors on Filling Imbalances in Multi-cavity Injection Mold. (다수 캐비티 사출금형에서 성형 인자가 충전 불균형에 미치는 영향)

  • Kang C. M.;Jeong Y. D.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2004.10a
    • /
    • pp.54-57
    • /
    • 2004
  • Almost all injection molds have multi-cavity runner for mass production, which are designed with geometrically balanced runner system in order to minimize filling imbalance between cavity to cavity during processing. However, even though geometrically balanced runner is used, filling imbalances have sometimes been observed. These filling imbalances have historically been considered as result of uneven mold temperature and mold deflection, but it actually results from non-symmetrically shear, pressure, temperature distribution within melt material as it flows through the runner system. Filling imbalance could be decreased by modifying processing conditions that are related to shear, pressure, temperature such as injection rate, mold temperature, injection pressure, melt temperature. In this study, a series of experiment was conducted using Taguchi method to determine which processing condition influence as the primary cause of filling imbalance in geometrically balanced runner system. As a result of experiments, this paper could present an optimal processing condition to minimize variable that brings about filling imbalance geometrically balanced runner system

  • PDF

Runner Design for Filling Balance in Multi-cavity Injection Mold (다수 캐비티 사출금형에서 충전 균형을 위한 런너의 설계)

  • Kang, M.A.;Lyu, M.Y.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2008.05a
    • /
    • pp.329-332
    • /
    • 2008
  • Flow imbalance among the cavities was often observed in multi-cavity mold. The flow imbalance affects on the dimensions and physical properties of melded articles. First of all, the origin of flow imbalance is geometrical imbalance of delivery system. However, even the geometry of delivery system is balanced the cavity imbalance is being developed. This comes from the temperature distribution in the cross-section of runner, which is affected by the operational conditions. In this study, experimental study of flow imbalance has been conducted for various injection speeds. This study also suggests new runner design to eliminate flow imbalance in multi-cavity injection mold. Simulation and experimental results showed suggested new designed runner could eliminate or reduce flow imbalance in multi-cavity injection mold.

  • PDF

The Filling Imbalance in Multi-Cavity Injection Molds with Unary Branch Type Runner Lay-out (편측 분기형 러너 배열을 가진 다수 캐비티 사출금형에서의 충전 불균형도)

  • 강철민;정영득
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2003.10a
    • /
    • pp.72-75
    • /
    • 2003
  • Almost all injection molds have multi-cavity runner system for productivity and are designed with geometrically balanced runner system in order to minimize filling imbalance between cavity to cavity during processing. However, filling imbalances have been observed though geometrically balanced runner lay-out are used. Generally, these filling imbalances are due to thermal unbalance, viscosity, characteristic of polymers and so on. These kinds of filling imbalances has already been reported by Beaumont[1] since 1997. In this study, we presented filling imbalaces in balanced runner that has unnary branch type lay-out through experimental tests. As a result of experiments, we could present the processing conditions for the balanced filling in geometrically balanced runner that has unnary branch type lay-out

  • PDF

A Closed-loop-control System for Filling Balance in the Hot Runner Mold with Multi-Cavities (다수 캐비티를 갖는 핫러너 금형에서의 균형충전을 위한 자동제어시스템)

  • Jang, Min-Kyu;Jo, Il-Kyu;Lee, Ok-Seong;Jeong, Yeong-Deug
    • Design & Manufacturing
    • /
    • v.9 no.1
    • /
    • pp.23-26
    • /
    • 2015
  • For mass production of plastics, injection molds have multi-cavities. However, filling imbalance between cavity to cavity always has occurred in multi-cavities mold, and this has caused low quality of plastics part. In this study, the closed-loop-control system which can control temperature of hot manifold and nozzle in hot runner mold for filling balance has been suggested, and a series of experiment about difference of filling time and weight in cavity-to-cavity was conducted. As a result of using closed-loop-control system, a remarkable improvement in reducing filling imbalance was confirmed.

  • PDF

Development of New Runner System for Filling Balance in Multi Cavity Injection Mold (다수 캐비티 사출금형에 적용되는 새로운 균형 충전용 러너 시스템 개발)

  • Jeong Y. D.
    • Transactions of Materials Processing
    • /
    • v.15 no.1 s.82
    • /
    • pp.42-46
    • /
    • 2006
  • For mass production, usually injection mold has multi-cavity which is filled through geometrical balanced runner system. Despite geometrical balanced runner system, filling imbalances between cavity to cavity have always been observed. These filling imbalances are one of the most significant factors to affect quality of plastic parts. Filling imbalances are results from non-symmetrical shear rate distribution within melt when it flows through tile runner system. It has been possible to decrease filling imbalance by optimizing processing conditions, but it has not completely eliminated this phenomenon during injection molding processing. This paper presents a solution for these filling imbalances by using Runner Core pin (RC pin). The Runner Core pin which is developed in this study creates a symmetrical shear distribution within runner. As a result of using Runner Core pin, a remarkable improvement in reducing filling imbalances was confirmed.

Degree of Filling Balance according to Runner Shapes in Injection Mold (사출금형의 러너시스템 형상에 따른 균형 충전도)

  • Han, Dong-Yeop;Jeong, Yeong-Deug
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.10
    • /
    • pp.144-149
    • /
    • 2008
  • Configuration of filling imbalance which is originated from imbalanced share rate of melt on runner is changed by runner layout, runner shape, material property, injection pressure, injection speed, melt temperature and mold temperature. In this paper, we conducted a study of runner layout and shape that are main factors of filling imbalance. Other factors such as the sharp corner effect and the groove corner effect are recently released were also considered. The results of study are showed that filling rate of between inside and outside cavity was influenced on shape of runner. Especially, this study suggests a new runner system for filling balance by adapting the two effects of unary branch type runner at multi cavity mold and theoretical investigated flow in the sharp corner type runner.

Degree of Filling Balance according to Runner Shapes in Injection Mold (사출금형의 러너시스템 형상에 따른 균형 충전도)

  • Han, Dong-Yeop;Jeong, Yeong-Deug
    • Design & Manufacturing
    • /
    • v.6 no.1
    • /
    • pp.52-57
    • /
    • 2012
  • Aspect of filling imbalance that is originated from imbalanced share rate in runner is changed by material property, runner layout that are factors of changing viscosity and by injection pressure, injection speed, melt temperature and mold temperature that are injection conditions. In this paper, we made a study of runner system that is one of factor of filling imbalance and Sharp Conner Effect and Groove Corner Effect that are recently released. The study are showed that filling rate of between inside and outside cavity was influenced on shape of runner. Also, we suggested runner system for filling imbalance by adapting the two effects at multi cavity of unary branch type and theoretical investigated flow in the Shrap Conner runner type.

  • PDF

A Study on the Filling Balance of Elastomer TPVs in Multi-Cavity Injection Mold (다수 캐비티 금형에서 엘라스토머 수지의 균형충전도 연구)

  • No B.S.;Han S.R.;Han D.Y.;Jeong Y.D.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.407-408
    • /
    • 2006
  • Almost all injection molds have multi-cavity, which are designed with geometrically balanced runner system in order to made filling balance between cavity to cavity during injection molding. However, filling imbalance has been existed in the geometrically balanced runner system. In this study, we made an experiment and surveyed that are filling balanced variation according to molding condition with thermoplastic vulcanizate (TPV). Also, we conducted experiments in order to know the influence of filling balance for runner core pin (RC pin).

  • PDF