• 제목/요약/키워드: cavitation.

Search Result 1,229, Processing Time 0.032 seconds

An Experimental Analysis of Ultrasonic Cavitation Effect on Ondol Pipeline Management (온돌 파이프라인 관리를 위한 초음파 캐비테이션 효과에 대한 실험적 분석)

  • Lee, Ung-Kyun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.24 no.1
    • /
    • pp.67-75
    • /
    • 2024
  • In the context of Korean residential heating systems, Ondol pipelines are a prevalent choice. However, the maintenance of these pipelines becomes a complex task once they are embedded within concrete structures. As time progresses, the accumulation of sludge, corrosive oxides, and microorganisms on the inner surfaces of these pipelines diminishes their heating efficiency. In extreme scenarios, this accumulation can induce corrosion and scale formation, compromising the system's integrity. Consequently, this research introduces an ultrasonic generation system tailored for the upkeep of Ondol pipelines, with the objective of empirically assessing its practicality. This investigation delineates three variants of ultrasonic generating apparatuses: those employing surface vibration, external generation, and internal generation techniques. To emulate the presence of contaminants within the pipelines, substances in powder, slurry, and liquid forms were employed. The efficacy of the cleaning process post-ultrasonic wave application was scrutinized over time, with image analysis methodologies being utilized to evaluate the outcomes. The findings indicate that ultrasonic waves, whether generated externally or internally, exert a beneficial effect on the cleanliness of the pipelines. Given the inherent characteristics of Ondol pipelines, external generation proves impractical, thereby rendering internal generation a more viable solution for pipeline maintenance. It is anticipated that future endeavors will pave the way for innovative maintenance strategies for Ondol pipelines, particularly through the advancement of internal generation technologies for pipeline applications.

Chemistry of mist deposition of organic polymer PEDOT:PSS on crystalline Si

  • Shirai, Hajime;Ohki, Tatsuya;Liu, Qiming;Ichikawa, Koki
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.388-388
    • /
    • 2016
  • Chemical mist deposition (CMD) of poly(3,4-ethylenedioxythiophene):poly(styrene sulfonate) (PEDOT:PSS) was investigated with cavitation frequency f, solvent, flow rate of nitrogen, substrate temperature $T_s$, and substrate dc bias $V_s$ as variables for efficient PEDOT:PSS/crystalline (c-)Si heterojunction solar cells (Fig. 1). The high-speed camera and differential mobility analysis characterizations revealed that average size and flux of PEDOT:PSS mist depend on f, solvent, and $V_s$. The size distribution of mist particles including EG/DI water cosolvent is also shown at three different $V_s$ of 0, 1.5, and 5 kV for a f of 3 MHz (Fig. 2). The size distribution of EG/DI water mist without PEDOT:PSS is also shown at the bottom. A peak maximum shifted from 300-350 to 20-30 nm with a narrow band width of ~150 nm for PEDOT:PSS solution, whose maximum number density increased significantly up to 8000/cc with increasing $V_s$. On the other hand, for EG/water cosolvent mist alone, the peak maximum was observed at a 72.3 nm with a number density of ~700/cc and a band width of ~160 nm and it decreased markedly with increasing $V_s$. These findings were not observed for PEDOT:PSS/EG/DI water mist. In addition, the Mie scattering image of PEDOT:PSS mist under white bias light was not observed at $V_s$ above 5 kV, because the average size of mist became smaller. These results imply that most of solvent is solvated in PEDOT:PSS molecule and/or solvent is vaporized. Thus, higher f and $V_s$ generate preferentially fine mist particle with a narrower band width. Film deposition occurred when $V_s$ was impressed on positive to a c-Si substrate at a Ts of $30-40^{\circ}C$, whereas no deposition of films occurred on negative, implying that negatively charged mist mainly provide the film deposition. The uniform deposition of PEDOT:PSS films occurred on textured c-Si(100) substrate by adjusting $T_s$ and $V_s$. The adhesion of CMD PEDOT:PSS to c-Si enhanced by $V_s$ conspicuously compared to that of spin-coated film. The CMD PEDOT:PSS/c-Si solar cell devices on textured c-Si(100) exhibited a ${\eta}$ of 11.0% with the better uniformity of the solar cell parameters. Furthermore, ${\eta}$ increased to 12.5% with a $J_{sc}$ of $35.6mA/cm^2$, a $V_{oc}$ of 0.53 V, and a FF of 0.67 with an antireflection (AR) coating layer of 20-nm-thick CMD molybdenum oxide $MoO_x$ (n= 2.1) using negatively charged mist of 0.1 wt% 12 Molybdo (VI) phosphoric acid n-Hydrate) $H_3(PMo_{12}O_40){\cdot}nH_2O$ in methanol. CMD. These findings suggest that the CMD with negatively charged mist has a great potential for the uniform deposition of organic and inorganic on textured c-Si substrate by adjusting $T_s$ and $V_s$.

  • PDF

A COMPARISON OF DECISIONS FOR PRIMARY ANTERIOR TEETH BETWEEN PEDIATRIC DENTISTS AND GENERAL DENTISTS (유전치 우식에 대한 치과의사들의 치료 선택 현황 조사)

  • Kim, Seong-Hee;Kim, Young-Jong;Kim, Shin;Jeong, Tae-Sung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.39 no.3
    • /
    • pp.242-248
    • /
    • 2012
  • Children usually have varying degree of caries in primary anterior teeth, and treatment planning for each case prescribed by each dentist can also be varied. This survey was conducted to compare the preferred treatment method and restorative materials between general dentists and pediatric dentists in regard to the treatment of primary incisors. The questionnaires, composed of 18 questions were sent to 45 general dentists and 50 pediatric dentists. Among which 30 and 31 questionnaires were retrieved respectively. The collected data were analyzed by rate and the results were as follows: 1. For the teeth with initial caries without cavitation, general dentists showed the tendency to prefer restorative treatment(30%) or observation without any treatment(42%), whereas pediatric dentists prefer preventive treatment(76%). 2. The primary factor in choosing restorative materials by both groups was its manipulativeness. 3. For anterior esthetic restoration, general dentists seldom use the full-coverage restoration(13%) but resin restoration(75%), whereas pediatric dentists frequently used full-coverage crow(64%). 4. In the treatment of dentinal caries, pediatric dentist did not perform the treatment lesser than 2.0 years before the exfoliation (compared to 1.2 years of general dentist). 5. In the treatment of 1 year children, both pediatric and general dentists tend to select preventive procedure as first choice of treatment(84%, 52%). When treating primary incisor caries, it is shown that pediatric dentists are more interested in restorative/preventive treatment than general dentists are.

Clinical Manifestations of Pulmonary Infection Due to Rapidly Growing Nontuberculous Mycobacteria (신속발육 비결핵항산균에 의한 폐감염의 임상상)

  • Kim, Eun Kyung;Shim, Tae Sun;Lim, Chae-Man;Lee, Sang Do;Koh, Younsuck;Kim, Woo Sung;Kim, Won Dong;Kim, Dong Soon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.54 no.3
    • /
    • pp.283-294
    • /
    • 2003
  • Introduction : Rapidly growing nontuberculous mycobacteria (RGM) can produce numerous types of manifestations including a pulmonary infection. Managing a pulmonary infection due to RGM is unusually difficult to treat because the organism is invariably resistant to traditional antituberculous drugs and has a varying susceptibility to other antibiotics. The experiences of treatments for a RGM pulmonary infection with various antibiotics are also limited. This study evaluated the clinical manifestations, treatment, and the therapeutic outcomes of a RGM pulmonary infection. Subjects and method : Fifty-four cases with RGM from respiratory specimens were identified between November of 1996 and September of 2002 in the Asan medical center. The medical records and radiographic findings in 20 patients who fulfilled the diagnostic criteria of nontuberculous mycobacteria (NTM) pulmonary disease by ATS guidelines. The clinical, laboratory, and radiological parameters between subgroups. Results : Of the 20 patients, 15 were female. The mean age was 57.7 yrs (${\pm}7.5$), and all of the patients had a history of pulmonary tuberculosis. Most (90%) had an underlying lung disease. The majority of the isolates (80%) were M. abscessus. Chest radiography showed bilateral involvement in 80% of the patients. Bronchiectasis and multiple nodules were the main findings. Cavitation was present in 35% of the patients. Even though 70 % of the patients received antituberculous drugs prior to the correct diagnosis, all of the patients eventually received antibiotics. A mean of 3.5 antibiotics were given for an average of 439 days(${\pm}168$). After completing treatment, nine patients showed improvement after a mean 591(${\pm}311$) days of treatment, whereas the antibiotic treatment was unsuccessful in 2 patients. Conclusion : Many patients with a RGM pulmonary infection show an atypical pattern of radiological findings (bronchiectasis and multiple centrilobular nodules). It is very important to differentiate between M. tuberculosis and NTM and to identify the causative organisms among the NTM because a misdiagnosis can lead to an inappropriate and prolonged treatment. Combined antibiotic treatment yielded promising results, and is recommended for treating patients with a RGM pulmonary infection.

Clinical Review of Pulmonary Tuberculosis in Teenagers According to the Involved Lung (소아청소년기 폐결핵의 방사선상 침범위치에 따른 배양 양성률과 임상양상에 대한 연구)

  • Im, Bong Chil;Kim, Young;Kim, Kyoung Sim;Kim, Yong Wook;Kim, Eun Young;You, Eun Jung;You, Ju Hee;Cho, Hyoung Min
    • Pediatric Infection and Vaccine
    • /
    • v.17 no.2
    • /
    • pp.148-155
    • /
    • 2010
  • Purpose : The purpose of this study was to investigate clinical features and culture-positive rates according to the involved lung in adolescent pulmonary tuberculosis (TB). Methods : We retrospectively reviewed the medical records of adolescents who ranged in age from 10 to 20 years and who had been hospitalized with a diagnosis of TB at Kwangju Christian Hospital from 2000 to 2008. Results : Sixty-six patients were identified with pulmonary TB: median age 16.82 years; 48.5% males. Among them, 90.9% of patients were between 15 and 20 years of age. Most patients presented with multiple symptoms, and the most common included cough (74.2%), sputum (60.6%), fever (39.5%), and night sweating (18.2%). Sputum samples were smear-positive in 28 (42.4%), culture-positive in 40 (60.6%), and PCR-positive in 46 (69.7%). The most common radiological patterns included cavitation in 18 (27.3%), pleural effusion in 18 (27.3%), lymphadenopathy in 10 (15.2%), and tuberculoma in 5 (7.6%). The prevalence of smear, culture, and PCR positive rates increased as the number of involved lobes increased (P<0.05, P<0.01, P<0.05). The median treatment duration was 7 months. Twelve patients (18.2%) had lower lung field TB (Group A) and forty-four patients (66.7%) had other areas involving TB, except for Group A (Group B), and ten patients (15.1%) had only TB pleurisy (Group C). The difference of clinical characteristics and culture rates between group A and group B was not significant. Conclusion : Pulmonary TB toward late adolescence is increasing. We need to pay more attention to lower lung field TB, which is difficult to detect with specific radiographic findings.

Experimental Studies on Lead Toxicity in Domestic II. Histopathology (고양이의 납중독에 관한 실험적 연구 2. 조직병리학적 소견)

  • Hong Soon-Ho;Han Hong Ryul
    • Journal of Veterinary Clinics
    • /
    • v.11 no.1
    • /
    • pp.485-505
    • /
    • 1994
  • Lead toxicity was evaluated in forty-five cats on a balanced diet, treated with 0(control), 10, 100(low), 1, 000, 2, 000 and 4, 000(high)ppm of lead acetate orally on a body weight basis. The objectives were to describe the gross and histopathologic changes and to demonstrate what tissue lead concentrations correlate with the known dosages of lead. In subclinical lead toxicity, greater than 80% of the absorbed lead was deposited in the bone, whereas in more acute lead toxicity, 42% of absorbed lead was deposited in the bone and 36% and 20% of absorbed lead was deposited in the kidneys and in the liver, respectively. No gross lesions were found in the nervous system. Yellow-brown colored livers appear to be associated with lead toxicity. Neuronal necrosis in the cerebrum was the most predominant histopathologic finding. Astrocytic proliferation in the cerebral gray matter was observed in 1 high dose cat. Gliosis was noted in the cerebral cortex of 6 high dose cats. Two high dose cats had demyelination in the deepest layer of the cortical gray matter of the cerebrum. Extravasation of red cells and cavitation around the vessels were found in the cerebrum of 1 high dose cat. Six high dose cats had degeneration of Purkinje cells in the cerebellum. The microscopic findings in the peripheral nerves were ambiguous. In more acute toxicity, the cats had lead inclusions in the epithelial cells of proximal tubules of the kidneys of 7 cats and hepatocytes of the liver of S cats. These inclusions could be seen wlth H&E, but were more prominent with orcein staining. Two high dose cats had granulomas and connective tissue hyperplasia between tubules of the kidneys. Periportal hepatocyte vacuolization was observed in the liver of 22 cats. Vacuolization of seminiferous tubules and a reduced number of spermatogonia(indicative of reduced spermatogenesis) were found in the testis of 5 treated cats. Cystic ovaries were observed in 3 high dose cats and poor development of oogonia was found in 2 cats. The diagnosis of lead toxicity in cats can be suspected on the basis of the histopathologic lesions described, and can be of value in contributing to a diagnosis. A reliable diagnosis of lead poisoning can be helped utilizing tissue lead analysis(post molten)

  • PDF

The Correlation between Bronchoscopic Morphology and Pathologic Type in Bronchogenic Carcinoma (폐암의 기관지 내시경 소견과 세포형의 연관성에 관한 연구)

  • Lee, Hyuk-Pyo;Yoo, Chul-Gyu;Kim, Young-Whan;Han, Sung-Koo;Shim, Young-Soo;Kim, Keun-Youl;Han, Yong-Chol
    • Tuberculosis and Respiratory Diseases
    • /
    • v.41 no.4
    • /
    • pp.389-396
    • /
    • 1994
  • Background : The two most important purposes of fiberoptic bronchoscopy in lung cancer patients are obtaining tissue diagnosis and staging. The direct sign of lung cancer on FOB includes visible tumor, with smooth or nodular surface, with or without necrosis and infiltration. Variant cell types of lung cancer have their characteristic biological behaviors respectively. For example, squamous cell carcinoma grows slowly, invades locally and has easy necrosis resulting in cavitation, whereas adenocarcinoma shows early metastasis, small cell carcinoma shows rapid growth and higher early metastasis rate. Based on this, it could be hypothesized that each cell type may have characteristic bronchoscopic finding. Method : To answer this question, we reviewed 106 cases which were diagnosed as primary lung cancer and had bronchoscopically visible specific cancerous lesions. Results : The results were as follows. 1) Squamous cell carcinoma accounted for 66 cases(62.2%), adenocarcinoma 15 cases(14.2%), large cell carcinoma 3 cases(2.8%). 2) The endobronchial tumor lesion was arbitrarily classified into 5 types according to gross characteristics. Type A, multilobulating mass with necrosis, accounted for 24.5%, type B, multilobulating mass without necrosis, 25.5%, type C, round beefy mass, 9.4%, type D, infiltration with mucosal irregularity, 6.6%, and type E, infiltration without mucosal irregularity, 34%. 3) The analysis of correlation between endobronchial tumor pattern and specific cell type revealed that squamous cell carcinoma had relation with the morphologic type B and small cell carcinoma had relation with the morphologic type E, but adenocarcinoma had no preponderance in morphologic type. The gross appearance had influence on the diagnostic yields of biopsies and the diagnostic yields of lobulating mass types(type A, B) were higher than those of other types. Conclusion : From the above observations, it could be concluded that squamous cell carcinoma and small cell carcinoma have relations with specific types of bronchoscopic morphology, but not the case in adenocarcinoma.

  • PDF

On Vortex Reduction Characteristics of Pump Sump Circulating Water Intake Basin of Power Plant Using Hydraulic Experiment (수리실험을 이용한 발전소의 순환수 취수부 흡입수조의 와류저감에 관한 연구)

  • Eom, Junghyun;Lee, Du Han;Kim, Hung Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.6
    • /
    • pp.815-824
    • /
    • 2022
  • Among the main facilities of the power plant, the circulating water used for cooling the power generation system is supplied through the Circulation Water Intake Basin (CWIB). The vortexes of various types generated in the Pump Sump (PS) of CWIB adversely affect the Circulation Water Pump (CWP) and pipelines. In particular, the free surface vortex accompanied by air intake brings about vibration, noise, cavitation etc. and these are the causes of degradation of CWP performance, damage to pipelines. Then power generation is interrupted by the causes. Therefore, it is necessary to investigate the hydraulic characteristics of CWIB through the hydraulic model experiment and apply an appropriate Anti Vortex Device (AVD) that can control the vortex to enable smooth operation of the power plant. In general, free surface vortex is controlled by Curtain Wall (CW) and the submerged vortex is by the anti vortex device of the curtain wall. The detailed specifications are described in the American National Standard for Pump Intake Design. In this study, the circulating water intake part of the Tripoli West 4×350 MW power plant in Libya was targeted, the actual operating conditions were applied, and the vortex reduction effect of the anti vortex device generated in the suction tank among the circulating water intake part was analyzed through a hydraulic model experiment. In addition, a floor splitter was basically applied to control the submerged vortex, and a new type of column curtain wall was additionally applied to control the vortex generated on the free surface to confirm the effect. As a result of analyzing the hydraulic characteristics by additionally applying the newly developed Column Curtain Wall (CCW) to the existing curtain wall, we have found that the vortex was controlled by forming a uniform flow. In addition, the vortex angle generated in the circulating water pump pipeline was 5° or less, which is the design standard of ANSI/HI 9.8, confirming the stability of the flow.

Experimental Study of Flip-Bucket Type Hydraulic Energy Dissipator on Steep slope Channel (긴구배수로 감세공의 Filp Bucket형 이용연구)

  • 김영배
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.13 no.1
    • /
    • pp.2206-2217
    • /
    • 1971
  • Spillway and discharge channel of reservoirs require the Control of Large volume of water under high pressure. The energies at the downstream end of spillway or discharge channel are tremendous. Therefore, Some means of expending the energy of the high-velocity flow is required to prevent scour of the riverbed, minimize erosion, and prevent undermining structures or dam it self. This may be accomplished by Constructing an energy dissipator at the downstream end of spillway or discharge channel disigned to dissipated the excessive energy and establish safe flow Condition in the outlet channel. There are many types of energy dissipators, stilling basins are the most familar energy dissipator. In the stilling basin, most energies are dissipated by hydraulic jump. stilling basins have some length to cover hydraulic jump length. So stilling basins require much concrete works and high construction cost. Flip bucket type energy dissipators require less construction cost. If the streambed is composed of firm rock and it is certain that the scour will not progress upstream to the extent that the safety of the structure might be endangered, flip backet type energy dissipators are the most recommendable one. Following items are tested and studied with bucket radius, $R=7h_2$,(medium of $4h_2{\geqq}R{\geqq}10h_2$). 1. Allowable upstream channel slop of bucket. 2. Adequate bucket lip angle for good performance of flip bucket. Also followings are reviwed. 1. Scour by jet flow. 2. Negative pressure distribution and air movement below nappe flow. From the test and study, following results were obtained. 1. Upstream channel slope of bucket (S=H/L) should be 0.25<H/L<0.75 for good performance of flip bucket. 2. Adequated lip angle $30^{\circ}{\sim}40^{\circ}$ are more reliable than $20^{\circ}{\sim}30^{\circ}$ for the safety of structures.

  • PDF