• Title/Summary/Keyword: cathodic

Search Result 755, Processing Time 0.024 seconds

Effect of Cathodic Biofilm on the Performance of Air-Cathode Single Chamber Microbial Fuel Cells

  • Ahmed, Jalal;Kim, Sung-Hyun
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.10
    • /
    • pp.3726-3729
    • /
    • 2011
  • Biofilm formation is inevitable in a bioelectrochemical system in which microorganisms act as a sole biocatalyst. Cathodic biofilm (CBF) works as a double-edged sword in the performance of the air-cathode microbial fuel cells (MFCs). Proton and oxygen crossover through the CBF are limited by the robust structure of extracellular polymeric substances, composition of available constituents and environmental condition from which the biofilm is formed. The MFC performance in terms of power, current and coulombic efficiency is influenced by the nature and origin of CBF. Development of CBF from different ecological environment while keeping the same anode inoculums, contributes additional charge transfer resistance to the total internal resistance, with increase in coulombic efficiency at the expense of power reduction. This study demonstrates that MFC operation conditions need to be optimized on the choice of initial inoculum medium that leads to the biofilm formation on the air cathode.

The Method Effect of Reinforced Concrete by Applying Impressed Current Cathodic Protection (외부전원법을 적용한 철근콘크리트의 방식효과)

  • Lee, Hae-Seung;Cho, Gyu-Hwan;Park, Dong-Cheon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.60-61
    • /
    • 2013
  • For reinforced concrete structures located in a sea environment, the Impressed Current Cathodic Protection (ICCP) is mostly used as a signature method to prevent steel corrosion. For this research, specimens to which the ICCP is applied were manufactured under the assumption of two following cases the specimens are exposed to various salt damage environments (submerged zone, tidal zone), and deteriorative factors (crack) occur in concrete. For the specimens manufactured, an enhancement experiment for deterioration was conducted through regular cycle change under the temperature between 15 ~ 70℃ with 70 ~ 90% humidity. Afterwards, the method effect was verified through a half-cell method and application of the ICCP derived from salt damage environments was investigated.

  • PDF

Distribution of Cathodic Protection Potential for Concrete Slab Specimens at Diverse Environmental Conditions

  • Jin, Chung-Kuk;Jeong, Jin-A
    • International Journal of Ocean System Engineering
    • /
    • v.3 no.2
    • /
    • pp.90-94
    • /
    • 2013
  • This study represents the recent laboratory results from cathodic protection (CP) system with the use of sacrificial anodes at different environmental conditions (temperature of $10^{\circ}C$ and $40^{\circ}C$). Specimens were slab type with a dimension of $500mm{\times}50mm{\times}100mm$, and concrete cover thickness were 25mm. Zinc mesh and/or bulk type anodes were installed at the center of specimen to confirm the distance that CP system has influences on the specimen to distribute uniform CP current to rebar. Two different kinds of temperature condition were applied to verify the effect of temperature. Experiments were conducted for 60 days, and the distribution of potential and current that supplied from anode to rebar was measured. From the results, CP potential was varied with time, and temperature played an important role in CP potential variations. Current was also changed with time, and current distribution could be improved by installing additional bulk type anode.

Acute and Chronic Eosinophilic Pneumonia; Clinical and Laboratory Findings (급성 및 만성 호산구성 폐렴의 임상적 고찰)

  • Hyun, D.S.;Yeo, D.S.;Kim, J.W.;Lee, S.H.;Lee, S.Y.;Kim, S.C.;Seo, J.Y.;Song, S.H.;Kim, C.H.;Moon, H.S.;Song, J.S.;Park, S.H.
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.4
    • /
    • pp.795-804
    • /
    • 1998
  • Background: Chronic eosinophilic pneumonia(CEP) is interstitial lung disease characterized by multiple infiltration on radiographic study, accumulation of eosinophils in the alveolar space and interstitium of the lung, chronic persistent symptoms and possible relapse. Acute eosinophilic pneumonia(AEP) is a recently described illness, characterized by rapid clinical course, acute respiratory insufficiency and no relapse. Method : To better characterize acute and chronic eosinophilic pneumonia, we studied the clinical and laboratory features of 16 patients(AEP : 7 patients, CEP : 9 patients), which were clinico-pathohistologically diagnosed and not to be associated with organic disorders producing peripheral blood eosinophilia. Results: The mean age was higher for patients with CEP than for patients with AEP ($55.4{\pm}15.1$ vs. $24.6{\pm}7.9$ years, p<0.05). High fever(above $38^{\circ}C$) was presented in all patients of AEP and in one patient(11%) of CEP. All patients of AEP and eight patients (89%) of CEP showed bilateral pulmonary infiltrates, and 6 patients(86%) of AEP and 2 patients(22%) of CEP showed pleural effusion in chest radiograph. The mean white blood cell count of AEP and CEP were $17,186/mm^3$ and $12,867/mm^3$, respectively. The mean peripheral blood eosinophil count of AEP and CEP were $939/mm^3$ and $2,104/mm^3$, respectively. The mean eosinophil fraction of BAL fluid of AEP and CEP were 32.4% (range: 18~47%) and 35.8% (range: 15.3~88.2%), respectively. The mean $PaO_2$ was lower for patients with AEP than for patients with CEP ($44.1{\pm}15.5$ vs. $62.7{\pm}6.9$mmHg, p<0.05). All patients of AEP and CEP were initially treated with antibiotics. All patients of CEP and one patients of AEP were finally required systemic steroid therapy. 6 patients of AEP were improved without steroid therapy. Relapse was observed in 3 patients(33%) of CEP. Conclusion : Compair with of chronic eosinophilic pneumonia, acute eosinophilic pneumonia was characterized by relatively young age, acute onset, high fever, severe hypoxemia, diffuse pulmonary infiltrates with pleural effusion, steroid therapy is effective but spontaneous improvement with conservative therapy was frequent.

  • PDF

Study on the Control of Erosion-Corrosion in Bearing Alloy Meals by Cathodic Protection (음극방식에 의한 선박용 베어링 합금재의 침식-부식억제에 관한 연구)

  • 서현수;임우조;이진열
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1994.06a
    • /
    • pp.40-41
    • /
    • 1994
  • 본 연구에서는 윤활유에 해수가 혼입된 유화유중에서 음극방식에 의한 선박용 베어링 합금재의 침식-부식억제에 관한 연구를 위하여, 초음파 진동장치의 캐비네이션 발생장치에 의해 선박용 베어링 합금재의 캐비네이션 침식-부식방지를 위해 음극방식(Cathodic protection)실험을 실시하였다. 이실험을 토대로 하여 해수의 혼입에 따른 유화유중에서 음극방식에 의한 베어링 합금재의 침식-부식억제효과를 구명하고자 한다.

  • PDF

A Study on the Standardization for Cathodic Protection System and its Testing Method in Korea (국내 전기방식 시스템 및 시험 방법에 대한 표준화 연구)

  • Bae, Jeong-Hyo;Ha, Tae-Hyun;Lee, Hyun-Goo;Kim, Dae-Kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.663-665
    • /
    • 2001
  • Generally, the owners of the facilities adopt CP(Cathodic Protection) Systems to protect the corrosion accidents previously. The developed countries have secured the standard of CP systems and its test methods through the various researches and consolidation of the rules. So, we have been studying the international standards; JSEC, NACE Standard, ASTM, DNV, Australian Standard etc. and standardizing the systems and its test methods to apply in Korea.

  • PDF

Corrosion Fatigue Crack Propagation Behaviour of TMCP Steel Plate at Ballast Tank of Ship Structure under the Condition of Cathodic Overprotection (선체구조 Ballast Tank 고장력 TMCP강판의 과방식중 부식피로균열 전파거동)

  • Kim, Won-Beom
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.6
    • /
    • pp.2465-2471
    • /
    • 2012
  • For the steel structures those are used in harsh sea environments, corrosion fatigue is a challenging issue in connection with design life. In this research, in order to investigate the influence of cathodic overprotection on the corrosion fatigue crack propagation behavior, corrosion fatigue crack propagation test under the condition of -950mV vs SCE was conducted by using of high tensile TMCP steel plate and the relationships between da/dN-${\Delta}K$ were obtained. At this test, when ${\Delta}K$ is low, the crack propagation rates were accelerated compared to those of seawater condition, however, when ${\Delta}K$ is high, the crack propagation rates were lower than those of seawater condition. As the cause for the acceleration and deceleration of corrosion fatigue crack propagation rates under the condition of cathodic overprotection, the role of hydrogen and calcareous deposits are discussed.