• Title/Summary/Keyword: cass test

Search Result 21, Processing Time 0.019 seconds

Evaluation of the Corrosion Resistance of Plated Ni and Ni-Cr Layers on Fe Substrate by Using Salt Spray, CASS and EC Tests (철소지 위에 형성된 니켈 및 니켈-크롬 도금층의 염수분무, 캐스, 전해부식시험법을 이용한 내식성평가)

  • 신재호;이동훈;이재봉;신성호
    • Journal of the Korean institute of surface engineering
    • /
    • v.36 no.4
    • /
    • pp.307-316
    • /
    • 2003
  • Salt spray, CASS(copper accelerated acetic salt spray) and EC(electrolytic corrosion) tests were performed in order to evaluate the corrosion resistance of plated Ni and Ni-Cr layers on Fe substrate. Compared with the conventional methods such as salt spray and CASS, the electrochemical method such as EC test may be beneficial in terms of test time span and quantitative accuracy. Furthermore, EC test can also become the alternative method to evaluate the resistance to corrosion of coatings by measuring the corrosion potentials of the coated layers in the electrolyte during the off-time of EC cycles. Compared with the corrosion potentials of pure iron, nickel, chromium, those potentials of coated layers can be used to anticipate the extent of corrosion. Results showed that in terms of the test time span, EC test gave 14 times and 21 times faster results than the salt spray test in cases of $5\mu\textrm{m}$ Ni and $20\mu\textrm{m}$ Ni plated layers, respectively. In addition, EC test also offered the shorter test time span than CASS test in cases of $5 \mu\textrm{m}$ Ni + $0.5\mu\textrm{m}$ Cr, and $20\mu\textrm{m}$ Ni + $0.5\mu\textrm{m}$ Cr on Fe substrate by 78 times and 182 times, respectively. Therefore, EC test can be regarded as the better method to evaluate the resistance to corrosion of coated layers than the conventional methods such as salt spray and CASS.

Evaluation of the Corrosion Protective Property in Steel applying Spray Metal by using High-frequency Arc Metal Spray Method (고주파 아크 금속용사공법을 이용한 용사금속의 방식성능 평가)

  • Choe, Hong-Bok;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.94-95
    • /
    • 2014
  • The purpose of this study is to evaluate the corrosion protective property of Al-Mg high-freqeuncy arc metal spray method in comparison to Zn-Sn and Zn-Al alloys by electrochemical method and CASS test. As a result, it appeared that Al-Mg alloy had very higher corrosion protective property through the electrochemical characteristic and the CASS test comparing with the other alloys.

  • PDF

Evaluations of corrosion resistance of Ni-Cr plated and Zn-plated Fe Substrates Using an Electrolytic Corrosion Test (전해부식시험을 이용한 니켈-크롬도금강판 및 아연도금강판의 내식성 비교평가시험)

  • Lee, Jae-Bong;Kim, Kyung-Wook;Park, Min-Woo;Song, Tae-Jun;Lee, Chae-Seung;Lee, Eui-Jong;Kim, Sang-Yeol
    • Corrosion Science and Technology
    • /
    • v.12 no.1
    • /
    • pp.56-64
    • /
    • 2013
  • An Eectrolytic Corrosion(EC) test method was evaluated by the comparison with Copper Accelerated Acetic Salt Spray(CASS) and Neutral Salt Spray(SS) tests. Those methods were applied in order to evaluate corrosion resistance of Ni-Cr plated and Zn-plated Fe substrates. The correlations between results obtained by different test methods were investigated. Results showed that the electrochemical method such as the EC test method was superior to the conventional methods such as CASS and SS, in terms of the quantitative accuracy and the test-time span. Furthermore, the EC test method provided the useful means to estimate the initiation of corrosion of each layer by monitoring the rest potentials of the coated layers such as Ni, Cr, and Zn on Fe substrate. With regard to test time spans, the EC test provided the 78 times and 182 times faster results than the CASS test in cases of $Fe+5{\mu}m$ $Ni+0.5{\mu}m$ Cr and $Fe+20{\mu}m$ $Ni+0.5{\mu}m$ Cr respectively, while the EC test was 85 times faster results than the Salt Spray test in the case of $Fe+20g/m^2$ Zn. Therefore, the EC test can be the better method to evaluate the resistance to corrosion of coated layers than the conventional methods such as the SS test and the CASS.

Applicability of nonlinear ultrasonic technique to evaluation of thermally aged CF8M cast stainless steel

  • Kim, Jongbeom;Kim, Jin-Gyum;Kong, Byeongseo;Kim, Kyung-Mo;Jang, Changheui;Kang, Sung-Sik;Jhang, Kyung-Young
    • Nuclear Engineering and Technology
    • /
    • v.52 no.3
    • /
    • pp.621-625
    • /
    • 2020
  • Cast austenitic stainless steel (CASS) is used for fabricating different components of the primary reactor coolant system of pressurized water reactors. However, the thermal embrittlement of CASS resulting from long-term operation causes structural safety problems. Ultrasonic testing for flaw detection has been used to assess the thermal embrittlement of CASS; however, the high scattering and attenuation of the ultrasonic wave propagating through CASS make it difficult to accurately quantify the flaw size. In this paper, we present a different approach for evaluating the thermal embrittlement of CASS by assessing changes in the material properties of CASS using a nonlinear ultrasonic technique, which is a potential nondestructive method. For the evaluation, we prepared CF8M specimens that were thermally aged under four different heating conditions. Nonlinear ultrasonic measurements were performed using a contact piezoelectric method to obtain the relative ultrasonic nonlinearity parameter, and a mini-sized tensile test was performed to investigate the correlation of the parameter with material properties. Experimental results showed that the ultrasonic nonlinearity parameter had a correlation with tensile properties such as the tensile strength and elongation. Consequently, we could confirm the applicability of the nonlinear ultrasonic technique to the evaluation of the thermal embrittlement of CASS.

A PRELIMINARY STUDY FOR THE DEVELOPMENT OF THE ASSESSMENT SCALE FOR ADHD IN ADOLESCENTS:RELIABILITY AND VALIDITY FOR CASS(S) (청소년 ADHD 평가 도구 개발을 위한 예비연구-CASS(S)의 신뢰도 및 타당도 연구)

  • Shin, Min-Sup;Cho, Soo-Churl;Hong, Kang-E;Bahn, Geon-Ho
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.12 no.2
    • /
    • pp.218-224
    • /
    • 2001
  • Although Attention Deficit Hyperactivity Disorder(ADHD) has been considered as the disorder occurring during childhood, the prevalence is increasing among adolescents and adults. The prevalence rate varies from 2.0 to 14.3% due to the difference of diagnostic criteria, different assessment methods, or subjects' age difference. Therefore, it needs to make age specific(i.e., for children, for adolescents, and for adults) assessment tools. Authors translated Conners-Wells Adolescents Self-Report Scales(short form)[CASS(S)] in to Korean to get validity and reliability as a way of development of assessment tool for adolescent with ADHD in Korea. CASS(S) was translated and corrtected by three psychiatrists and one clinical psychologist. To examine the concurrent validity and test-retest validity, CASS(S) was applied with K-YSR on one class of each grade in a middle school in Seoul with two week interval(total 115:male 58, female 57). To test validity, authors analysed and got Cronbach's as internal consistency. Construct validity was done by principal axis factor analysis on 4,354 students. As a result, Cronbach's alpha for internal consistency was .88, Pearson coefficient for test-retest reliability .83, and coefficient for concurrent validity .65. And in the factor analysis to examine construct validity, three factors were revealed as cognition, hyperactivity, and conduct. These results shows that CASS(S) may be useful tool for adolescents with ADHD, although there was a limit not to be done the comparison with clinical groups.

  • PDF

Corrosion Protection of Steel by Applying a Zn-Sn Metal Spray System (Zn-Sn 합금을 이용한 강구조물의 금속용사공법 방식성능평가 연구)

  • Ryu, Hwa-Sung;Jeong, Dong-Geun;Lee, Han-Seung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.14 no.6
    • /
    • pp.505-513
    • /
    • 2014
  • The purpose of this study is to evaluate the corrosion protective properties of a Zn-Sn metal spray method according to the contents of Zn and Sn by a CASS test and the electrochemical theory. In the experiment, the CASS test and the electrochemical test were conducted to investigate the corrosion protective property of the Zn-Sn Metal Spray system, the Zinc galvanizing system, and the heavy duty coating system. As a result, it was confirmed that the Zn-Sn (65:35) Metal Spray system had very high corrosion protective property through the electrochemical characteristic as comparison with the other anti-corrosion systems and was very effective to prevent steel products from corrosion.

Fabrication of Chromium-based Double Layered Deposit (크롬계 이중도금층 제조 및 특성평가)

  • Park, Sang-Eon;Kim, Dong-Su;Kim, Man;Jang, Do-Yeon;Gwon, Sik-Cheol
    • 연구논문집
    • /
    • s.31
    • /
    • pp.127-133
    • /
    • 2001
  • In chromium electrodeposition, crack is inevitably accompanied by chromium layer. Behavior of crack formation and crack density were different from the plating conditions such as current density, temperature, waveform of applied current and so on. And cracks have an influence on the corrosion resistance of chromium deposit, because corrosion occurs through the network of cracks between deposit and substrate. Therefore, many researches have been achieved in order to remove the cracks in chromium deposit. Formation of double layers, Cr/Cr and Ni/Cr were investigated to increase corrosion resistance of chromium deposit in this study. As pretreatment prior to outer chromium coating, acid pickling and current control method were examined. Cracks in cross-section of each sample were observed with SEM and CASS(Copper modified acetic acid salt spray) test was performed to evaluate corrosion resistance. It was found that corrosion resistance of Cr/Cr and Ni/Cr double layers were superior to Cr or Ni single layer from the results of CASS test.

  • PDF

Vasovagal syncope with mild versus moderate autonomic dysfunction: a 13-year single-center experience

  • Lee, Han Eoul;Lee, Dong Won
    • Clinical and Experimental Pediatrics
    • /
    • v.65 no.1
    • /
    • pp.47-52
    • /
    • 2022
  • Background: An adequate large-scale pediatric cohort based on nationwide administrative data is lacking in Korea. Purpose: This study aimed to differentiate patients with VVS by autonomic dysfunction severity using the composite autonomic severity score (CASS) and compare the clinical manifestations and prognosis between patient subgroups. Methods: We retrospectively reviewed the medical records of 66 VVS patients divided into 3 groups by CASS. To compare the differences between these groups, we analyzed VVS type, triggers, prodromal symptoms, management of syncope, and prognosis between patients with mild versus moderate autonomic dysfunction. Results: Of our 66 patients with VVS, 41 had mild autonomic dysfunction (62.1%) and 25 had moderate autonomic dysfunction (37.9%). We found no significant intergroup differences in age, sex, inducible factor (P=0.172), prodromal symptoms, laboratory findings, head-up tilt test, type of syncope, or prognosis (P=0.154). Conclusion: We found no evidence that autonomic dysfunction degree is affected by VVS characteristics, test findings, parameters, or prognosis; therefore, no further evaluations are needed to classify autonomic dysfunction severity.

Experimental Study of The Corrosion Protection Performance of The Metal Spraying Process in accordance with ratio of Zn-Al (Zn-Al의 구성비율에 따른 금속용사 공법의 방식성능에 대한 실험적 연구)

  • Kim, Hae;Eom, Sung-Hyun;Jeong, Hyun-Gyu;Lee, Jeong-Bae;Kim, Seong-Soo;Ahn, Jae-Woo
    • Resources Recycling
    • /
    • v.26 no.2
    • /
    • pp.56-65
    • /
    • 2017
  • This study is an experimental study on the corrosion protection performance according to the configuration ratio of the Zn and Al. A metal spraying was used as the arc metal spraying method, a specimen was produced by varying the proportion ratio and coating thickness of the Zn and Al. Experimental methods visually observed to corrosion of the specimen for 1, 3, 7, 15 days was conducted in accordance with the CASS salt spray test. This study has confirmed that the performance of the corrosion protection improved against the increase in the Al content. Further, it was confirmed that excellent perfomance is exhibited when the coating thickness is secured over $80{\mu}m$. In addition, the SEM analysis was performed to observe the cross-sectional shape of the metal spraying specimen after CASS testing. The analysis result showed that the deterioration of the metal spraying coating layer was reduced as the Al content increases.