• Title/Summary/Keyword: cascade multilevel inverter

Search Result 29, Processing Time 0.039 seconds

A New Scheme for Maintaining Balanced DC Voltages in Static Var Compensator(SVC) Using Cascade Multilevel Inverter

  • Min, Wan-Ki;Min, Joon-Ki;Choi, Jae-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.561-565
    • /
    • 2001
  • This paper proposes a new switching scheme of a static var compensator(SVC) with cascade multilevel inverter which employs H-bridge inverter(HBI). To improve the un­balanced problem of the DC capacitor voltages, the rotated switching scheme of fundamental frequency is newly used. The optimized fundamental switching pattern with low switching frequency is adapted to be suitable for high application. The selective harmonic elimination method(SHEM) allows to keep the total harmonic distortion(THD) low in the output voltage of multilevel inverter. The SVC system is modeled using the d-q transform which calculates the instantaneous reactive power. This model is used to design a controller and analyze the SVC system. Simulated and experimental results are also presented and discussed to validate the proposed schemes.

  • PDF

A New Control Scheme for Maintaining Balanced DC Voltages in Static Var Compensator(SVC) Using Cascade Multilevel Inverter (직렬형 멀티레벨 인버터를 사용한 무효전력보상장치의 직류전압평형을 위한 새로운 제어기법)

  • Min, Wan-Ki;Min, Joon-Ki;Choi, Jae-Ho
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.54 no.4
    • /
    • pp.179-184
    • /
    • 2005
  • This paper examines the application of high voltage static var compensator(SVC) with cascade multilevel inverter which employs H-bridge inverter(HBI). A new switching scheme is developed for the SVC system. To improve the unbalanced problem of the DC capacitor voltages, the rotated switching scheme of fundamental frequency is newly used. The optimized fundamental switching pattern with low switching frequency is adapted to be suitable for high application. The selective harmonic elimination method(SHEM) allows to keep the total harmonic distortion(THD) low in the output voltage of multilevel inverter. The SVC system is modeled using the d-q transform which calculates the instantaneous reactive power. This model is used to design a controller and analyze the SVC system. Simulated and experimental results are also presented and discussed to validate the proposed schemes.

Control of Static Var Compensator Using A Cascade Typed Multilevel Voltage Source Inverter (멀티레벨 직렬 전압형 인버터를 이용한 무효전력보상기(SVC)의 제어)

  • Min, Wan-Ki;Park, Yong-Bae;Kim, Yeong-Han;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.332-335
    • /
    • 1996
  • Multilevel voltage source inverters are emerging as a new breed of power inverter options for high power applications. This paper presents a cascade typed multilevel voltage source inverter which has separate de sources for high voltage. This inverter is proposed for flexible ac transmission systems (FACTS) including static var compensator(SVC), series compensation and phase shifting. It can solve the problems of conventional transformer-based multipulse inverters and the problems of multilevel diode-clamped inverters. To show the superiority of multilevel cascaded inverter, simulation results are discussed in detail.

  • PDF

Control of The D-STATCON Using Multilevel Voltage Source Inverters (MULTILEVEL 전압형 인버터들을 사용한 D-STATCON의 제어)

  • Min, Wan-Ki;Min, Jun-Ki;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.1925-1927
    • /
    • 1998
  • D-STATCON using the multilevel voltage source inverters is presented for voltage regulation and reactive power compensation in distribution system. This cascade M-level inverter consists of (M-1)/2 single phase full bridge inverter(FBI). This multilevel inverter is a natural fit to the flexible ac transmission systems(FACTS) including STATCON, SVC, series compensation and phase shifting, It can solve the problems of conventional transformer-based multipulse inverters and multilevel diode-clamped inverters. From the simulation results, the superiority of D-STATCON with cascade multilevel inverter is shown for high power application.

  • PDF

Design of Advanced Static Var Compensator(ASVC) for Distribution Line (배전선로 적용을 위한 새로운 무효전력보상치(ASVC)의 설계)

  • Min, Wan-Ki;Lee, Sang-Hun;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1997.07f
    • /
    • pp.2010-2012
    • /
    • 1997
  • A cascade multilevel voltage source inverter is introduced to apply the advanced static var compensator(ASVC) for large scale power application. This cascade M-level inverter consists of (M-1)/2 single-phase full bridges. This inverter is suitable to the flexible ac transmission systems(FACTS) including SVC, series compensation and phase shifting. It can solve the problems of conventional transformer -based multipulse inverters and multilevel diode-clamped inverters. From the simulation results, the validity of ASVC with cascade multilevel inverter is shown for high power application.

  • PDF

Novel Control of STATCOM Using Cascade Multilevel Inverter for High Power Application (대전력용 직렬형 멀티레벨 인버터 이용한 STATCOM의 새로운 제어기법)

  • Min, Wan-Ki;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2000.07e
    • /
    • pp.136-141
    • /
    • 2000
  • This paper proposes the novel control of a static synchronous compensator (STATCOM). This STATCOM system consists of cascade multilevel inverter which employs H-bridge inverter(HBI) The STATCOM system is modeled in the d-q transform matrix. This model is used to design a controller. The selective harmonic elimination method(SHEM) allows to keep the total harmonic distortion (THD) low in the output voltage. The switching method produces the staircase type waveform in cascade multilevel inverter. To balance the DC voltages in HBIs capacitor, the rotated switching scheme is newly proposed in this paper. The proposed control scheme is verified in the simulated results.

  • PDF

Design of Parameters for High Power Static Var Compensator Used Cascade Multilevel Inverter (직렬형 멀티레벨 인버터를 사용한 대용량 무효전력 보상장치의 파라메타 설계)

  • Min, Wan-Ki;Choi, Jae-Ho
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.52 no.4
    • /
    • pp.172-178
    • /
    • 2003
  • This paper examines the application of high voltage static var compensator(SVC) with cascade multilevel inverter which employs H-bridge inverter(HBI). This method has the primary advantage that the number of voltage levels can be increased for a given number of semiconductor devices when compared to the conventional control methods. The SVC system is modeled using the d-q transform which calculates the instantaneous reactive power. This model is used to design a controller and analyze the SVC system. From the mathematical model of the system, the design procedures of the circuit parameters L and C are presented in this thesis. To meet the specific total harmonic distortion(THD) and ripple factor of the capacitor voltage, the circuit parameters L and C are designed. Simulated and experimental results are also presented and discussed to validate the proposed schemes.

Modeling and Analysis of Static Var Compensator Using Hybrid Cascade Multilevel Inverter (하이브리드 Cascade 멀티레벨 인버터를 이용한 무효전력보상기의 모델링 및 해석)

  • Choi Nam-Sup
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.618-621
    • /
    • 2002
  • This paper proposes a static vu compensator using hybrid cascade 5-level PWM inverter, Circuit DQ transformation is used for modeling and analysis of the system, and it reveals the important characteristics and related equations of the system. Also, a multilevel PWM technique suitable to hybrid structure Is proposed for less harmonics in the input currents of the system. Finally, the validity of tile characteristics analysis is shown through PSIM simulations.

  • PDF

Multi-modulating Pattern - A Unified Carrier based PWM method In Multi-level Inverter - Part 2

  • Nho Nguyen Van;Youn Myung Joong
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.625-629
    • /
    • 2004
  • This paper presents a systematical approach to study carrier based PWM techniques (CPWM) in diode-clamped and cascade multilevel inverters by using a proposed named multi-modulating pattern method. This method is based on the vector correlation between CPWM and the space vector PWM (SVPWM) and applicable to both multilevel inverter topologies. A CPWM technique can be described in a general mathematical equation, and obtain the same outputs similarly as of the corresponding SVPWM. Control of the fundamental voltage, vector redundancies and phase redundancies in multilevel inverter can be formulated separately in the CPWM equation. The deduced CPWM can obtain the full vector redundancy control, and fully utilize phase redundancy in a cascade inverter In this continued part, it will be deduced correlation between CPWM equations in multi-carrier system and single carrier system, present the mathematical model of voltage source inverter related to the common mode voltage and propose a general algorithm for multi-modulating modulator. The obtained theory will be demonstrated by simulation results.

  • PDF

Novel Switching Strategy of 1MVar STATCON using Cascade Multilevel Voltage Source Inverter for FACTS Application (FACTS 적용을 위한 직렬형 멀티레벨 전압형 인버터를 사용한 1MVar STATCON의 새로운 스위칭기법)

  • Min, Wan-Gi;Min, Jun-Gi;Choe, Jae-Ho
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.12
    • /
    • pp.691-700
    • /
    • 1999
  • This paper proposes a novel switching strategy of 1Mvar STATCON using cascade multilevel H-bridge inverter(HBI) for FACTS application. To control the reactive power instantaneously, the d-q dynamic system model is described and analyzed. A single pulse pattern based on the SHEM(Selective Harmonic Elimination Method) technique is determined from the look-up table to reduce the line current harmonics and a rotating fundamental frequency switching scheme is presented to adjust the DC voltage of each inverter capacitor at the same value. So the voltage unbalance problem between separately DC bus voltage is improved by using the proposed switching scheme. As a result, the presented inverter configuration not only reduces the system complexity by eliminating the isolation at the AC input side transformer but also improves the dynamic response to the step change of reactive power.

  • PDF