• 제목/요약/키워드: carrier gas

검색결과 626건 처리시간 0.036초

A Study on Properties of RF-sputtered Al-doped ZnO Thin Films Prepared with Different Ar Gas Flow Rates

  • Han, Seung Ik;Kim, Hong Bae
    • Applied Science and Convergence Technology
    • /
    • 제25권6호
    • /
    • pp.145-148
    • /
    • 2016
  • This paper, Al-doped ZnO(AZO) thin films for application as transparent conducting oxide films were deposited on the Corning glass substrate by using RF magnetron sputtering system. The effects of various Argon gas flow rates on optical and electrical characteristics of AZO films were investigate sputtering method. The Carrier Concentration is enhanced as Ar gas rate increases, and also the oxygen vacancy concentration. The figure of merit obtained in this study means that AZO films which deposited Ar gas rate of 75 sccm have the highest Carrier concentration and Hall mobility, which have the highest photoelectrical performance that it could be used as transparent electrodes.

가스하이드레이트 생성조건 최적화에 관한 실험적 연구 (Experimental Study on Optimal Generation of Methane Hydrate)

  • 윤석호;이정호;이공훈;박상진
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1317-1321
    • /
    • 2009
  • Natural gas liquefaction plant and LNG carrier needs large capital investment. Therefore a lot of small or middle scale natural gas fields aren't developed due to poor profitability. If natural gas is made to gas hydrate instead of liquefaction, developing small-scale natural gas field can be profitable because building cost of gas hydrate plant and carrier are economical. Because the process of making gas hydrate consumes much energy, the gas hydrate formation process has to be optimized for energy consumption. In this study, gas hydrate formation process was investigated experimentally. Experimental apparatus consists of reactor, pressure regulator, chiller, and magnetic stirrer. 99.95% methane was used to make gas hydrate. Tests were conducted at variable pressure and temperature condition.

  • PDF

ZnO 막막 센서의 TMA 가스 검지 특성 분석 (The analysis on TMA gas-sensing characteristics of ZnO thin film sensors)

  • 류지열;박성현;최혁환;김진섭;이명교;권태하
    • 전자공학회논문지D
    • /
    • 제34D권12호
    • /
    • pp.46-53
    • /
    • 1997
  • The TMA gas sensors are fabricated with the ZnO-based thin films grown by a RF magnetron sputtering method. The hall effect measurement and AES analysis are carried out to investigate the effects of the sputtering gases and dopants which effect on the electrical resistivity and sensitivity to TMA gas. We measure the cfhanges of the surface carrier concentration, haall electron mobility, electrical resistivity, surface condition, and depth profile of the films. The ZnO-based thin film sensors sputtered in oxygen, or added with dopants showed a high sruface carrier concentration, film sensors sputtered in oxygen and doped with 4.0 wt.% $Al_{2}$O$_{3}$, 1.0 wt.% TiO$_{2}$, and 0.2 wt% v$_{2}$O$_{5}$ showed the highest surface carrier concentration of 5.952 * 10$^{20}$ cm$^{-3}$ , hall electron mobility of 176.7 cm$^{2}$/V.s, lowest electrical resistivity of 6*10$^{-5}$ .ohm.cm and highest sensitivity of 12. These results were measured at a working temperature of 300.deg. C to 8 ppm TMA gas.

  • PDF

Synthesis of Ceria Nanosphere by Ultrasonic Spray Pyrolysis

  • Kim, Jong-Young;Kim, Ung-Soo;Cho, Woo-Seok
    • 한국세라믹학회지
    • /
    • 제46권3호
    • /
    • pp.249-252
    • /
    • 2009
  • Nanocrystalline ceria particles were prepared by using the ultrasonic spray pyrolysis method. The prepared ceria particles were found to be spherical and non-agglomerated by the SEM and TEM analyses. It was found that carrier gas influences the size and morphology. It was found that the air stream of carrier gas results in porous agglomerated structure of ceria abrasives, whereas solid nano-sphere can be obtained in a more oxidizing atmosphere.

가스센서용 고순도 다공질 알루미나 담체의 제조 (Preparation of High-purity Porous Alumina Carrier for Gas Sensor)

  • 이창우;현성호;함영민
    • 한국화재소방학회논문지
    • /
    • 제11권3호
    • /
    • pp.15-23
    • /
    • 1997
  • In this study, the alumina for gas sensor was prepared by anodic oxidation. It was stable thermally and chemically, and pore diameter and pore distribution was uniform. And the shape of pore was cylinderical. The aluminum plate was carried out by the thermal oxidation, chemical polishing and electropolishing pretreatment. The pore diameter, pore size distribution, pore density and thickness of alumina was observed with the change of reaction temperature, electrolyte concentration and current density. As a results, It was able to use for carrier because alumina which was prepared by anodic oxidationhas uniform pore size distribution.

  • PDF

초음파 분무열분해에 의한 Bi-Pb-Sr-Ca-Cu-O의 미분체 제조 (Direct Preparation of fine Powders of Bi-Pb-Sr-Ca-Cu-O by Ultrasonic Spray Pyrolysis)

  • 주명희;박도순;김윤수
    • 한국세라믹학회지
    • /
    • 제28권5호
    • /
    • pp.353-358
    • /
    • 1991
  • Fine powders of the 2212 superconducting phase of bismuth system have been prepared directly from solution using ultrasonic spray pyrolysis. The fine superconducting powders produced by pyrolysis were characterized for the size, shape, and crystalline phase by SEM and XRD. The pyrolysis temperature, flow rate of the carrier gas, residence time of the droplets greatly influenced the size, shape, and crystalline phase. The optimum temperature and flow rate of the carrier gas for the preparation of fine powders of the 2212 superconduting phase were found to be 830$^{\circ}C$and 3ι/min, respectively.

  • PDF

가스추진 LNG 운반선의 가스 압축기실에 설치된 가스검출장치의 최적 배치에 관한 연구 (Optimal Gas Detection System in Cargo Compressor Room of Gas Fueled LNG Carrier)

  • 이상원;소예덕;이승훈;이진욱;정은석;강호근
    • 해양환경안전학회지
    • /
    • 제25권5호
    • /
    • pp.617-626
    • /
    • 2019
  • 본 연구는 가스추진 174K급 LNG 운반선의 가스 압축기실에서 발생하는 가스누출 모사를 통해 가스탐지기의 최적 위치를 분석하였으며, 새로 개정된 IGC 코드에 명시된 안전규정을 만족하는 합리적인 방법도 함께 제안하였다. 가스압축기실에서의 LNG 가스누출 수치해석을 위해, 실제 ME-GI 엔진이 장착된 174K급 LNG 운반선의 압축기실 형상과 장비, 배관의 배치와 같은 치수로 3D 설계되었다. 가스누설에 대한 시나리오는 305 bar의 높은 압력과 1 bar의 낮은 압력을 적용하여 진행하였다. 고압용 핀홀의 크기는 4.5, 5.0, 5.6 mm이고 저압용은 100, 140 mm이다. 해석 결과, 5.6 mm 핀홀(고압)과 100, 140 mm 핀홀(저압) 상태의 누출에 대한 환기평가에서 가연성 가스농도는 심각한 위험이 없음을 확인하였다. 그러나 개정된 IGC 코드에 따라 설치된 압축기실의 가스 감지 센서의 실제 위치는 다른 지점으로 이동해야 하고, 측정 지점이 현 규정에서 요구하는 것보다 더 추가되어야 함을 확인하였다.

Visualization and classification of hidden defects in triplex composites used in LNG carriers by active thermography

  • Hwang, Soonkyu;Jeon, Ikgeun;Han, Gayoung;Sohn, Hoon;Yun, Wonjun
    • Smart Structures and Systems
    • /
    • 제24권6호
    • /
    • pp.803-812
    • /
    • 2019
  • Triplex composite is an epoxy-bonded joint structure, which constitutes the secondary barrier in a liquefied natural gas (LNG) carrier. Defects in the triplex composite weaken its shear strength and may cause leakage of the LNG, thus compromising the structural integrity of the LNG carrier. This paper proposes an autonomous triplex composite inspection (ATCI) system for visualizing and classifying hidden defects in the triplex composite installed inside an LNG carrier. First, heat energy is generated on the surface of the triplex composite using halogen lamps, and the corresponding heat response is measured by an infrared (IR) camera. Next, the region of interest (ROI) is traced and noise components are removed to minimize false indications of defects. After a defect is identified, it is classified as internal void or uncured adhesive and its size and shape are quantified and visualized, respectively. The proposed ATCI system allows the fully automated and contactless detection, classification, and quantification of hidden defects inside the triplex composite. The effectiveness of the proposed ATCI system is validated using the data obtained from actual triplex composite installed in an LNG carrier membrane system.

글로우방전 가스크로마토그라프 검출기에서 방전가스의 영향 (Effect of Discharge Gas on the Electrical Characteristics of the Glow Discharge Plasma for the Gas Chromatographic Detector)

  • 박현미;강종성;김효진
    • 약학회지
    • /
    • 제39권5호
    • /
    • pp.480-486
    • /
    • 1995
  • The change in discharge current of a glow discharge has been shown the potential sensitive detector for gas chromatography. To investigate the effect of carrier gas on the electrical characteristics of the discharge and the peak response, the discharge pressure, gas flow rate, and discharge gap have been studied. The discharge gas included the Ar, He, and N$_{2}$. The gas flow rate has been found one of the important parameters to affect both the electrical characteristics and the peak response.

  • PDF

가스 크로마토그래픽 컬럼의 유동특성에 대한 수치적 연구 (A NUMERICAL STUDY ON THE FLOW CHARACTERISTICS OF GAS CHROMATOGRAPHIC COLUMN)

  • 김태안;김윤제
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2005년도 추계 학술대회논문집
    • /
    • pp.21-26
    • /
    • 2005
  • Gas Chromatography (GC) is a wisely technique used for the separation and analysis of liquid and gas sample. Separation of the sample vapors is achieved via their differential migration through a capillary column with an insert carrier gas. The identity and quantity of each vapor in the mixer can be determined from its retention time in the column and a particular property of the gas, such as thermal conductivity, which can be related to the concentration of sample vapor in the carrier gas. Therefore, the flow characteristics in the spiral gas chromatographic column are numerically investigated in this study. Especially, different pressure drop between the front and the rear of GC column with various flow rates is estimated the governing equations are derived from making using of three-dimensional Naver-Stokes equation with incompressible and laminar model due to the nature of low Reynolds number flow. Using a commercial code, FLUENT, the pressure and flow fields in GC column are calculated with various flow rates. The characteristics of thermal cycling which is one of the most important factors affecting the column efficiency and analysis time is also estimated. Furthermore, numerical analyses are also carried out by using commercial code, ANSYS, with various values of power, which is applied to the heating element located at lower GC column.

  • PDF