• Title/Summary/Keyword: caries detection

Search Result 90, Processing Time 0.025 seconds

The influence of different scan resolutions on the detection of proximal caries lesions

  • Ferreira, Liana Matos;Queiroz, Polyane Mazucatto;Santaella, Gustavo Machado;Wenzel, Ann;Groppo, Francisco Carlos;Haiter-Neto, Francisco
    • Imaging Science in Dentistry
    • /
    • v.49 no.2
    • /
    • pp.97-102
    • /
    • 2019
  • Purpose: This study was conducted to evaluate the effect of different spatial resolutions of a photostimulable phosphor plate (PSP) radiography system on the detection of proximal caries lesions. Materials and Methods: Forty-five extracted human permanent teeth were radiographed using a PSP system (VistaScan Perio Plus) and scanned at the 4 resolutions (10 lp/mm, 20 lp/mm, 25 lp/mm, and 40 lp/mm) available in the system. Three independent examiners scored the images for the presence and absence of proximal caries lesions using a 5-point scale. The presence or absence of caries was confirmed by histological sections of the examined teeth (defined as the gold standard). Intra- and inter-observer reproducibility was calculated by the weighted kappa test. One-way analysis of variance with the post hoc Tukey test was used to compare the area under the receiver operating characteristic curve for the classifications made with each resolution. Results: For the detection of enamel lesions, the spatial resolution of 10 lp/mm was significantly superior to the other resolutions. However, the spatial resolution did not affect the detection of caries lesions in dentin (P>0.05). Conclusion: Spatial resolution may influence the accuracy of the detection of incipient caries lesions in radiographs with PSP plates. Images with low spatial resolution seem to be more appropriate for this purpose.

Effect of changing the kilovoltage peak on radiographic caries assessment in digital and conventional radiography

  • Zayet, Mohamed Khalifa;Helaly, Yara Rabee;Eiid, Salma Belal
    • Imaging Science in Dentistry
    • /
    • v.44 no.3
    • /
    • pp.199-205
    • /
    • 2014
  • Purpose: This study aimed to investigate the effect of changing the kilovoltage peak (kVp) on the radiographic assessment of dental caries. Materials and Methods: Seventy-five extracted posterior teeth with proximal caries or apparently sound proximal surfaces were radiographed with conventional E-speed films and a photostimulable phosphor system using 60 kVp and 70 kVp for the caries assessment. The images were evaluated by three oral radiologists and compared with the results of the stereomicroscope analysis. Results: No statistically significant difference was found between 60 kVp and 70 kVp for the caries detection, determination of caries extension into dentin, and caries severity in either the conventional or the digital images. Good to very good inter-observer and intra-observer agreements were found for both kilovoltage values on the conventional and digital images. Conclusion: Changing the kilovoltage between 60 kVp and 70 kVp had no obvious effect on the detection of proximal caries or determination of its extension or severity.

Quantitative Light-Induced Fluorescence: A Potential Tool for Dental Hygiene Process (Quantitative Light-Induced Fluorescence의 이해와 치위생 과정에서의 활용방안)

  • Kim, Hee-Eun
    • Journal of dental hygiene science
    • /
    • v.13 no.2
    • /
    • pp.115-124
    • /
    • 2013
  • Recently, there have been improvements in diagnostic methods for the assessment of early caries lesions. The reason is that dental professionals are seeking methods to reliably detect incipient dental caries and to remineralize them. This review examines the literature on principles, theoretical background, and history of the Quantitative Light-Induced Fluorescence (QLF) system (Inspektor Research Systems BV, The Netherlands). Furthermore, this paper discusses the potential application of QLF system to clinical practice for educational purpose, enabling dental hygiene students to perform oral health assessment using the QLF system. In addition, the clinical application of QLF system can motivate patients by providing additional visual information about caries and bacterial activity. The evidences on validity and reliability of the QLF system for detection of longitudinal changes in de/remineralization and caries were examined. The QLF system is capable of monitoring and quantifying mineral changes in early caries lesions. Therefore, it can be used to assess the impacts of caries preventive measures on the remineralization and reversal of the caries process. And the QLF system is a very promising equipment to assess educational effectiveness for dental hygiene students in their learning process. In conclusion, the QLF system is the most effective technology for more sensitive staging of caries and treatment without surgical intervention.

HIDDEN CARIES: CASE REPORT (Hidden caries의 치험례)

  • Yoon, Hye-Jeong;Kim, Seong-Oh;Son, Heung-Kyu;Choi, Byung-Jai;Lee, Jae-Ho;Song, Je-Seon;Choi, Hyung-Jun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.37 no.4
    • /
    • pp.532-536
    • /
    • 2010
  • Hidden caries is a subtype of the occlusal pit and fissure caries type and is defined as a dentinal caries lesion near the occlusal surface of the tooth seen on a radiograph. In visual examination, the occlusal enamel is seen intact or is minimally perforated. Covert caries, Occlult caries or Fluoride syndrome are used as synonym. The percentage of occlusal dentin lesions that are clinically undetected ranges from 1.4-50%. Little is known about the mechanisms involved in the development of hidden caries. But it is thought that extensive use of topical fluoride or the special bacteriological profile has been a major factor. This case report is about detection and treatment of hidden caries of two children who visited the department of pediatric dentistry, Yonsei University Dental Hospital. The color of caries dentin found in hidden caries lesion is lighter than cavity forming caries, which makes it more difficult to detect caries by visual examination. Therefore diagnosis of hidden caries is often accomplished after clinical sign is recognized by patients. The use of advanced caries detection aids such as Diagnodent.. with periodic radiographic examination is seemed to be helpful for early detection of hidden caries.

Detection method of proximal caries using line profile in digital intra-oral radiography (디지털 구내방사선사진에서 라인 프로파일을 이용한 인접면우증식의 인지 방법)

  • Park, Jeong-Hoon;Choi, Yong-Suk;Kim, Gyu-Tae;Hwang, Eui-Hwan;Lee, Gi-Ja;Choi, Sam-Jin;Park, Hun-Kuk
    • Imaging Science in Dentistry
    • /
    • v.39 no.4
    • /
    • pp.185-189
    • /
    • 2009
  • Purpose : The purpose of this study was to investigate how to detect proximal caries using line profile and validate linear measurements of proximal caries lesions by basic digital manipulation of radiographic images. Materials and Methods : The X-ray images of control group (15) and caries teeth (15) from patients were used. For each image, the line profile at the proximal caries-susceptible zone was calculated. To evaluate the contrast as a function of line profile to detect proximal caries, a difference coefficient (D) that indicates the relative difference between caries and sound dentin or intact enamel was measured. Results : Mean values of D were $0.0354{\pm}0.0155$ in non-caries and $0.2632{\pm}0.0982$ in caries (p<0.001). Conclusion : The mean values of caries group were higher than non-caries group and there was correlation between proximal dental caries and D. It is demonstrated that the mean value of D from caries group was higher than that of control group. From the result, values of D possess great potentiality as a new detection parameter for proximal dental caries.

  • PDF

Clinical Application of DIAGNOcam (DIAGNOcam의 임상적 적용)

  • Kim, Jinhyock;Kim, Jongsoo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.43 no.4
    • /
    • pp.461-466
    • /
    • 2016
  • Dental caries is an important dental disease among children and adolescents that can continue for a lifetime. Early detection of dental caries in deciduous dentition is significant because it can influence the permanent teeth. It is also critical to prevent dental caries by performing fluoride treatment and pit-and-fissure sealant for high-risk children. Various methods have been developed for the early detection of dental caries; however, many studies are still seeking to discover more effective methods. In general, visual examination and radiographic images are used, but these techniques have several limitations such as errors and radiation exposure. In this study, clinical application of the newly developed DIAGNOcam caries identification device and its possible applications were examined. DIAGNOcam was applied to diagnose dental caries in the posterior teeth of patients in the Department of Pediatric Dentistry, and it was confirmed that it could be used to detect proximal caries, the margin of restoration, and the extent of dental caries lesions.

Computer-aided proximal caries diagnosis: correlation with clinical examination and histology

  • Kang Byung-Cheol;Scheetz James P;Farman Allan G
    • Imaging Science in Dentistry
    • /
    • v.32 no.4
    • /
    • pp.187-194
    • /
    • 2002
  • Purpose: To evaluate the performance of the LOGICON Caries Detector using RVG-4 and RVG-ui sensors, by comparing results of each detector to the results of clinical and histological examinations. Materials and Methods : Pairs of extracted teeth were radiographed, and a total of 57 proximal surfaces, which included both carious and non-carious situations, were analyzed. The RVG-4 produced 8-bit images, while the RVG-ui unit produced 12-bit images, which were taken in the high sensitivity mode. The images produced by the LOGICON were evaluated by a trained observer using both automated and manual caries detection software modes. Ground sections of the teeth established the actual absence or existence of caries. Results: LOGIC ON-aided caries detection and depth discrimination of the RVG-4 and RVG-ui sensors were equally inconsistent irrespective of whether the LOGIC ON software was set to the automated or manual mode. Sensitivity ranged from 50% to 57% for caries penetration of the enamel-dentin junction. Conclusion: Care needs to be taken when using LOGIC ON in conjunction with RVG images as an adjunct for treatment planning dental caries. Even when applied by a trained observer, substantial discrepancies exist between the results of the LOGIC ON software-guided evalutations using RVG images and histologic examination.

  • PDF

Detection of proximal caries using quantitative light-induced fluorescence-digital and laser fluorescence: a comparative study

  • Yoon, Hyung-In;Yoo, Min-Jeong;Park, Eun-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.6
    • /
    • pp.432-438
    • /
    • 2017
  • PURPOSE. The purpose of this study was to evaluate the in vitro validity of quantitative light-induced fluorescence-digital (QLF-D) and laser fluorescence (DIAGNOdent) for assessing proximal caries in extracted premolars, using digital radiography as reference method. MATERIALS AND METHODS. A total of 102 extracted premolars with similar lengths and shapes were used. A single operator conducted all the examinations using three different detection methods (bitewing radiography, QLF-D, and DIAGNOdent). The bitewing x-ray scale, QLF-D fluorescence loss (${\Delta}F$), and DIAGNOdent peak readings were compared and statistically analyzed. RESULTS. Each method showed an excellent reliability. The correlation coefficient between bitewing radiography and QLF-D, DIAGNOdent were -0.644 and 0.448, respectively, while the value between QLF-D and DIAGNOdent was -0.382. The kappa statistics for bitewing radiography and QLF-D had a higher diagnosis consensus than those for bitewing radiography and DIAGNOdent. The QLF-D was moderately to highly accurate (AUC = 0.753 - 0.908), while DIAGNOdent was moderately to less accurate (AUC = 0.622 - 0.784). All detection methods showed statistically significant correlation and high correlation between the bitewing radiography and QLF-D. CONCLUSION. QLF-D was found to be a valid and reliable alternative diagnostic method to digital bitewing radiography for in vitro detection of proximal caries.

Deep learning convolutional neural network algorithms for the early detection and diagnosis of dental caries on periapical radiographs: A systematic review

  • Musri, Nabilla;Christie, Brenda;Ichwan, Solachuddin Jauhari Arief;Cahyanto, Arief
    • Imaging Science in Dentistry
    • /
    • v.51 no.3
    • /
    • pp.237-242
    • /
    • 2021
  • Purpose: The aim of this study was to analyse and review deep learning convolutional neural networks for detecting and diagnosing early-stage dental caries on periapical radiographs. Materials and Methods: In order to conduct this review, the Preferred Reporting Items for Systematic Reviews and Meta-Analyses(PRISMA) guidelines were followed. Studies published from 2015 to 2021 under the keywords(deep convolutional neural network) AND (caries), (deep learning caries) AND (convolutional neural network) AND (caries) were systematically reviewed. Results: When dental caries is improperly diagnosed, the lesion may eventually invade the enamel, dentin, and pulp tissue, leading to loss of tooth function. Rapid and precise detection and diagnosis are vital for implementing appropriate prevention and treatment of dental caries. Radiography and intraoral images are considered to play a vital role in detecting dental caries; nevertheless, studies have shown that 20% of suspicious areas are mistakenly diagnosed as dental caries using this technique; hence, diagnosis via radiography alone without an objective assessment is inaccurate. Identifying caries with a deep convolutional neural network-based detector enables the operator to distinguish changes in the location and morphological features of dental caries lesions. Deep learning algorithms have broader and more profound layers and are continually being developed, remarkably enhancing their precision in detecting and segmenting objects. Conclusion: Clinical applications of deep learning convolutional neural networks in the dental field have shown significant accuracy in detecting and diagnosing dental caries, and these models hold promise in supporting dental practitioners to improve patient outcomes.

Effects of various cone-beam computed tomography settings on the detection of recurrent caries under restorations in extracted primary teeth

  • Kamburoglu, Kivanc;Sonmez, Gul;Berktas, Zeynep Serap;Kurt, Hakan;Ozen, Dogukan
    • Imaging Science in Dentistry
    • /
    • v.47 no.2
    • /
    • pp.109-115
    • /
    • 2017
  • Purpose: The aim of this study was to assess the ex vivo diagnostic ability of 9 different cone-beam computed tomography (CBCT) settings in the detection of recurrent caries under amalgam restorations in primary teeth. Materials and Methods: Fifty-two primary teeth were used. Twenty-six teeth had dentine caries and 26 teeth did not have dentine caries. Black class II cavities were prepared and restored with amalgam. In the 26 carious teeth, recurrent caries were left under restorations. The other 26 intact teeth that did not have caries served as controls. Teeth were imaged using a $100{\times}90-mm$ field of view and a 0.2-mm voxel size with 9 different CBCT settings. Four observers assessed the images using a 5-point scale. Kappa values were calculated to assess observer agreement. CBCT settings were compared with the gold standard using a receiver operating characteristic analysis. The area under the curve (AUC) values for each setting were compared using the chi-square test, with a significance level of ${\alpha}=.05$. Results: Intraobserver kappa values ranged from 0.366 to 0.664 for observer 1, from 0.311 to 0.447 for observer 2, from 0.597 to 1.000 for observer 3, and from 0.869 to 1 for observer 4. Furthermore, interobserver kappa values among the observers ranged from 0.133 to 0.814 for the first reading and from 0.197 to 0.805 for the second reading. The highest AUC values were found for setting 5 (0.5916) and setting 3 (0.5886), and were not found to be statistically significant(P>.05). Conclusion: Variations in tube voltage and tube current did not affect the detection of recurrent caries under amalgam restorations in primary teeth.