• Title/Summary/Keyword: capsule

Search Result 1,229, Processing Time 0.022 seconds

A Study on the Thermodynamic Performance of Plastic Bottle Ice Storage System (플라스틱병을 이용한 빙축시스템의 열역학적 성능에 관한 연구)

  • Lee, S.K.;Kim, H.Y.;Lee, Y.D.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.4
    • /
    • pp.484-496
    • /
    • 1996
  • This paper presents an anlaysis on the thermodynamic performance of ice storage system. The primary interest in this work is the exergetic efficiency of the system. The ice storage system considered here is the capsule type system with the waste plastic bottle being used as a capsule. To examine the characteristics of irreversibility production and exergetic efficiency in detail the ice storage system to be analyzed has been separated from the refrigerator in this analysis. The analysis is based on the lumped model with 3 uniform temperatures. The results indicate that 3 dimensionless parameters can describe the exergetic efficiency of the system, from which the characteristics of irreversibilities and the ranges of these parameters to ensure the reasonable performance of the system can be found. Experiments also have been performed to demonstrate the feasibility of such a system. This analysis only shows the performance of ice storage side, with the refrigeration side excluded. However, the results can be interpreted as a total performance if the refrigerator coupled with the ice storage system operatres reversibly.

  • PDF

The Development of transportation and handling device for spent nuclear fuel rod cuts (사용후핵연료 절단연료봉 운반/취급장치 개발)

  • Hong D.H.;Jin J.H.;Jung J.H.;Kim K.H.;Kim S.H.;Yoon J.S.;Ko B.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1715-1718
    • /
    • 2005
  • During demonstrations of a process conditioning spent nuclear fuels, it may be necessary to transport and handle Spent fuel road cuts from Post Irradiation Examination facility to Slitting device in The hot cell. It may be not easy to transport spent fuel rod cuts because rod cuts are high radioactive materials. For this purpose, we have developed a capsule for transporting and handling high radioactive materials. We have analyzed conditions of a hot cell and requirements of the device, designed and manufactured The prototype of the device, and done some performance tests. From the tests, it has been shown that transportation and handling without scattering nuclear material was smooth but the weight of capsule was heavy. These result will be reflected to a design of the improved transportation and handling device which will be used during demonstrations.

  • PDF

Consideration of Various Medial Capsulorrhaphy Methods in Hallux Valgus Surgery (무지 외반증의 수술 중 시행하는 내측 관절낭 봉합술의 방법에 대한 고찰)

  • Choi, Sung-Jong;Kim, Byung-Cheol;Eun, Il-Soo;Huh, Jung-Wook
    • Journal of Korean Foot and Ankle Society
    • /
    • v.12 no.1
    • /
    • pp.9-13
    • /
    • 2008
  • Purpose: Medial capsulorrhaphy is additional hallux reduction method following various hallux reduction procedures and we are going to report author's opinion about several methods of medial capsulorrhaphy. Materials and Methods: We performed three kinds of medial capsulotomy and imbricatory capsulorrhaphy in hallux valgus surgery. Through 8 cadavar study, we compared the easiness of sesamoid reduction and hallux valgus angle reduction. Also, we measured thickness of capsule in various portions. Results: Longitudinal capsule incision and imbrication was useful in sesamoid reduction and vertical procedures was useful in hallux valgus angle reduction. The capsule thickness was measured thickest in dorsal and distal portioin. Conclusion: The methods of medial capsulorrhaphy should be planned preoperatively considering individual hallux deformities. These selected medial capsulorrhaphy can help the reduction of hallux valgus deformity correction and its maintenance.

  • PDF

Understanding of Interactions Between Acanthamoeba and Escherichia coli on Cell-Based System

  • Jung, Suk-Yul
    • Biomedical Science Letters
    • /
    • v.17 no.3
    • /
    • pp.173-176
    • /
    • 2011
  • Free-living Acanthamoeba are eukaryotic protozoan organisms that are widely distributed in the air, water, etc such as environment. Acanthamoeba ingest the Escherichia coli which will replicate in cytoplasm of Acanthamoeba. Bacterial pathogenicity or virulence is one of important determinant factors to survive in free-living Acanthamoeba and otherwise Acanthamoebic pathogenicity is also an important factor for their interactions. Bacterial association with pathogenic strain of Acanthamoeba T1 and T4 was lower about two times than non-pathogenic T7. Bacterial invasion percentages into T1 were higher about three times than T7 but bacterial survival in T7 was increased as T1. The capsule-deletion mutant exhibited limited ability for invasion/uptake by and survival inside pathogenic Acanthamoeba T4. E. coli-outer membrane protein A (OmpA) decreased bacterial association with A. castellanii by about three times and it had higher effects than lipopolysaccharides (LPS). Under favorable conditions, the mutants were not survived in Acanthamoeba up to 24 h incubation. Therefore, this review will report pathogenic and non-pathogenic Acanthamoeba strains interactions with E. coli and its several mutants, i.e., capsule, OmpA and LPS.

An Analysis of Gravity-Assisted Melting of Subcooled Solid Filled Inside a Spherical Capsule (구형용기내 고상의 하강운동을 고려한 융해과정의 해석)

  • 서정세;김찬중;노승탁
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.10
    • /
    • pp.2601-2610
    • /
    • 1993
  • A numerical study on the melting process inside an isothermal spherical capsule is made. It is assumed that the phase change medium of its solid phase is heavier than the liquid phase and therefore the unmelted solid core is continuously moving downward on account of gravity forces. Such a gravity-assisted melting is commonly characterized by the existence of a thin liquid film below the solid core. The present study is motivated to present a full-equation-based analysis of the influences of the initial subcooling and the natural convection on the fluid flow and heat transfer characteristics associated with the gravity-assisted melting. In the light of the solution strategy, the present study is substantially distinguished from the existing works in that the complete set of governing equations in both the melted and unmelted regions are resolved without subdivision of the solution domains. For example, the liquid film region and the upper melted region are treated here as one domain and thus obviating laborious efforts to couple them. Numerical results are obtained by varying the Rayleigh numbers and the degree of subcooling. For the range of parameters examined, the presence of subcooling was found to impede the melting rate. The dropping velocity of the unmelted solid core was observed to affect the natural convection in the liquid significantly. When compared with the available experimental data, much improved prediction was achieved.

Enhancement of Nitrendipine Bioavailability in Rats by its Solid Dispersion with $Hydroxypropyl-{\beta}-Cyclodextrin$ after Oral Administration (흰쥐에 경구 투여시 히드록시프로필-베타-시클로덱스트린과 니트렌디핀 고체분산에 의한 생체이용률 증가)

  • Yong, Chul-Soon
    • Journal of Pharmaceutical Investigation
    • /
    • v.27 no.4
    • /
    • pp.295-301
    • /
    • 1997
  • Nitrendipine, a slightly soluble calcium channel blocking agent forms a solid dispersion system with $hydroxypropyl-{\beta}-cyclodextrin$, which exhibits better dissolution characteristics than the uncomplexed drug. The dissolution rate of nitrendipine was markedly increased in solid dispersion system in pharmacopeial disintegration media at pH 1.2 and pH 6.8. Four different dosage forms of nitrendipine were administered to rats: (a) nitrendipine in the solution of PEG 400; (b) nitrendipine solid dispersion system with $hydroxypropyl-{\beta}-cyclodextrin$ in a molar ratio of 1:2 by solvent evaporation method and administered in capsule form; (c) physical mixture of nitrendipine with $hydroxypropyl-{\beta}-cyclodextrin$ in a molar ratio of 1:2 and administered in capsule form; (d) nitrendipine alone administered in capsule form. Relative bioavailability after the oral administration of various dosage forms to rats with a dose of 10 mg/kg equivalent to nitrendipine was compared with that of nitrendipine in the solution of PEG 400. The AUC of solid dispersion was significantly bigger than that of nitrendipine powder. $T_{max}$ of solid dispersion was significantly shorter and $C_{max}$ was higher than that of nitrendipine powder. These results indicate that the bioavailability of nitrendipine could be improved markedly by inclusion complexation. An interesting correlation also appears to exist between the in vitro dissolution data and the area under the plasma concentration-time curves.

  • PDF

A Pneumococcal Conjugate Vaccine Formula Induces Protection in Mice Against Disseminated Disease due to Streptococcus pneumoniae (페렴구균 전신감염에 대한 협막. 표면단백질 접합백신의 효과)

  • Han , Yong-Moon;Lee , Jue-Hee
    • YAKHAK HOEJI
    • /
    • v.48 no.6
    • /
    • pp.345-351
    • /
    • 2004
  • ln the present work to determine effect of a Streptococcus pneumoniae conjugate vaccine, S.pneumoniae capsule attached to the surface protein (JY-Pol) was ex amined. This JY-Pol contained approximately 92% and 6% carbohydrate and protein, respectively. Gel electrophoresis revealed the presence of the surface protein in the JY-Pol. By the double immunodiffusion and isotyping ELISA analyses, administration of JY-Pol that was adsorbed to alum adjuvant (JY-Pol/Alum) into mice induced IgM, IgG, and IgA specific for the S.pneumoniae capsule. The ATCC capsular polysaccharide adsorbed to alum (ATCC-Pol/Alum) provoked only IgM in mice. In survival tests, mice that were immunized with the JY-Pol/Alum before intravenous challenge with live S.pneumoniae survived entire period of 46 day-observation, whereas all mice that received ATCC-Pol/Alum or only diluent instead of the vaccination died within 5 and 12 days, respectively. Results from footpad-edema test showed that JY-Pol/Alum formula provoked the cellular immunity as determined by swelling of the mouse footpad. These data indicate that the naturally conjugated JY- Pol enhances resistance of mice against disseminated pneumococcal disease due to S.pneumoniae by both humoral and cellular immune responses.

Bioequivalence of Hepaphil Soft Capsule to Nissel Tablet (닛셀정에 대한 헤파필연질캡슐의 생물학적 동등성 평가)

  • Ko, In-Ja;Chi, Sang-Cheol
    • YAKHAK HOEJI
    • /
    • v.48 no.6
    • /
    • pp.379-383
    • /
    • 2004
  • Biphenyl dimethyl dicarboxylate (DDB) has been used for the treatment of chronic viral hepatitis B and drug-induced hepatitis through the inhibition of lipid peroxidation and c ovalent binding of drug metabolites to lipids of microsomes. The bioequivalence of two DDB products was evaluated according to the guidelines of KFDA. The test product was Hepaphil soft capsule(R) made by KMS Pharm. Co. Containing 3 mg DDB and the reference product was Nissel tablet(R) made by Taerim Pharm. Co. Containing 25 mg DDB. Twenty healthy male subjects, 25.4(22~30) years old and 66.7(54~77)kg, were divided into two groups and a randomized $2{\times}2$ cross-over study was employed. After two tablets or two capsules were orally administered, blood was taken at predetermined time intervals and the concentration of DDB in plasma was determined using a validated HPLC method with UV detector. Two pharmacokinetic parameters, $AUC_t$ and $C_{max}$, were calculated and analyzed statistically for the evaluation of bioequivalence of the two products. Analysis of variance was carried out using logarithmically transformed parameter values. The 90% confidence intervals of $AUC_t$ and $C_{max}$ were log 0.91~log1.00 and log 1.05~log 1.15, respectively. These values were within the acceptable bioequivalence intervals of log 0.8 to log 1.25. Thus, the criteria of the KFDA guidelines for the bioequivalence was satisfied, indicating that Hepaphil soft capsule is bioequivalent to Nissel tablet.

Artificial Microparticle Diets for Culturing Rotifer, Brachionus plicatilis

  • Hwang Joo-Ae;Kim Sung-Koo
    • Fisheries and Aquatic Sciences
    • /
    • v.1 no.1
    • /
    • pp.30-34
    • /
    • 1998
  • Rotifer culture fed on five types of artificial microparticle diets were evaluated to substitute the natural diets such as Chlorella or w-yeast. These microparticle diets including solidified blood using squid oil (SBSO), solidified blood using soybean oil (SBSB), nylon protein walled particle (NPW) simple coacervation oil capsule (SCO), complex coacervation oil capsule(CCO), were tested for the evaluation of feeding efficiency. The prepared micro particle diets had diameters ranging from 3 to 30 Jim. Rotifer culturing experiments were carried out in 3-liter beakers for 13-16 days. The initial inoculum density of rotifers was 10 ind./ml. The rotifers fed on Chlorella or $\omega-yeast$ showed maximal densities of 2,000 ind./ml in 9 days or 500 ind./ml in 7 days, respectively. Those fed on SBSO, SBSB or NPW showed maximal densities of 1568 ind./ml, 586 ind./ml or 503 ind./ml, respectively and the reproductive rates for those diets were equivalent to or better than w-yeast. However, the coacervated oil capsule showed lower maximal densities of 400 ind./ml for SCO and less than 100 ind./ml for CCO due to the unbalanced diet formulation and indigestibility.

  • PDF

Pressure Monitoring System in Gastro-Intestinal Track (소화기관내의 압력 모니터링 시스템)

  • 김용인;박석호;김병규;박종오
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.10 no.11
    • /
    • pp.1089-1094
    • /
    • 2004
  • Diseases in the gastro-intestinal track are on an increasing trend. In order to diagnose a patient, the various signals of the digestive organ, such as temperature, pH, and pressure, can offer the helpful information. Among the above mentioned signals, we choose the pressure variation as a monitoring signal. The variation of a pressure signal of the gastro-intestinal track can offer the information of a digestive trouble or some clues of the diseases. In this paper, a pressure monitoring system for the digestive organs of a living pig is presented. This system concept is to transmit the measured biomedical signals from a transmitter in a living pig to wireless receiver that is positioned out of body. The integrated solution includes the following parts: (1) the swallow type pressure capsule, (2) the receiving set consisting of a receiver, decoder box, and PC. The merit of the proposed system if that the monitoring system can supply the precise and repeatable pressure in the gastro-intestinal track. In addition, the design of low power consumption enables it to keep sending reliable signals while the pressure capsule is working in the digestive organ. The subject of the study for the pressure monitoring system is in-vivo experiments for a living pig. We achieved the pressure tracings in digestive organs and verified the validity of system after several in-vivo tests using pressure monitoring system. As a result, we found each organ has its own characterized pressure fluctuation.