• Title/Summary/Keyword: capsule

Search Result 1,229, Processing Time 0.022 seconds

The Effects of PCM Capsule Sizes on the Properties of Acrylic Coatings (PCM 캡슐의 크기가 아크릴 코팅의 물성에 미치는 영향)

  • Hur, Soon-Ryoung;Lee, Sung-Goo;Choi, Kil-Yeong;Lee, Jae Heung;Hong, Geun-Hye;Kim, Hyung-Joong
    • Journal of Adhesion and Interface
    • /
    • v.6 no.1
    • /
    • pp.11-18
    • /
    • 2005
  • The capsules were prepared from a phase change material (PCM) of octadecane as a core material and melamine formaldehyde resin as a shell material. The PCM capsule size was varied in the range of $3{\sim}25{\mu}m$. The core contents and sizes of the PCM capsule, were determined by DSC and SEM, respectively. An acrylic coating material which contains butyl acrylate (BA), methyl metacrylate (MMA) and acrylic acid (AA) were synthesized by emulsion polymerization. The films were prepared from the acrylic emulsion and PCM capsules which have various capsule sizes. From the results of SEM experiment, it was observed that the PCM capsules were well dispersed inside the film and the surface of the film became less rough when the PCM capsule size was small. The swelling ratio of the films were not significantly affected by the PCM capsule size. However, the tensile strength and elongation of the films were greatly decreased with increasing the PCM capsule size.

  • PDF

Clinical Characteristics of Papillary Thyroid Microcarcinoma Involving Posterior Thyroidal Capsule (갑상선 후방 피막을 침범하는 갑상선미세유두암의 임상양상에 대한 고찰)

  • Jang, Seong Uk;Oh, Jung Ho;Kim, Seo Bin;Kim, Sung Won;Lee, Hyoung Shin;Noh, Woong Jae;Lee, Kang Dae
    • Korean Journal of Head & Neck Oncology
    • /
    • v.31 no.2
    • /
    • pp.6-10
    • /
    • 2015
  • Background and Objective : Papillary thyroid microcarcinoma(PTMC) is known as slow growing cancer with good prognosis. However, extrathyroidal extension may increase the risk of cervical lymph node metastasis and local invasion to surrounding structures. The aim of this study was to assess the characteristic features of the tumor invading the posterior thyroid capsule. Material and Methods : We made a retrospective review of 123 PTMC patients with thyroid capsule invasion, pathologically staged as T3 or T4. 74 patients (60.2%) had invasion to posterior thyroid capsule (group A) while 49 patients (39.8%) had invasion to-anterior thyroid capsule or anterior wall of trachea (group B). We assessed the clinicopathologic factors of the patients according to the location of capsular invasion of PTMC. Results : There was no difference regarding age, gender, T and N classification and incidence of lymph node metastasis between two groups. Local invasion rate to recurrent laryngeal nerve was 6.8% in patients with posterior thyroid capsule invasion, while the incidence was zero in those with capsular invasion to other locations Conclusion : Increased risk of local invasion to the recurrent laryngeal nerve should be considered in patients with PTMC presenting invasion of the posterior capsule.

  • PDF

Design and Implementation of the RF Systems for Bi-directional Wireless Capsule Endoscopes

  • Moon, Yeon-Kwan;Lee, Jyung-Hyun;Park, Hee-Joon;Lee, Ju-Gab;Ryu, Jae-Jong;Lee, Wu-Seong;Woo, Sang-Hyo;Won, Chul-Ho;Cho, Jin-Ho;Choi, Hyun-Chul
    • Journal of Korea Multimedia Society
    • /
    • v.9 no.12
    • /
    • pp.1669-1680
    • /
    • 2006
  • This paper explains that the RF systems for hi-directional wireless capsule endoscopes were designed and implemented. The designed RF systems for a capsule endoscope can transmit the images of intestines from the inside to the outside of a body and the behavior of the capsules can be controlled by an external controller simultaneously. The hi-directional wireless capsule endoscope consists of a CMOS image sensor, FPGA, LED, battery, DC to DC Converter, transmitter, receiver, and antennas. The transmitter and receiver which were used in the hi-directional capsule endoscope, were designed and fabricated with $10mm(diameter){\times}3.2mm(thickness)$ dimensions taking into the MPE, power consumption, system size, signal to noise ratio and modulation method. The RF systems designed and implemented for the hi-directional wireless capsule endoscopes system were verified by in-vivo experiments. As a result, the RF systems for the hi-directional wireless capsule endoscopes satisfied the design specifications.

  • PDF

Characteristics of Multi-embryo Egg Capsule and Larvae of Mottled Skate Raja pulchra from Korea (한국산 참홍어(Raja pulchra)의 다배성 난각 특징과 자어의 형태)

  • Jo, Hyun-Su;Kang, Eon-Jong;Cho, Yeong-Rok;Seo, Hyung-Chul;Im, Yang-Jae;Hwang, Hak-Jin
    • Korean Journal of Ichthyology
    • /
    • v.22 no.4
    • /
    • pp.217-224
    • /
    • 2010
  • An investigation was carried out to obtain basic information needed to develop methods for artificial propagation and conservation of the mottled skate Raja pulchra, an important food resource in western Korea that has declined from overfishing. In this paper we provide evidence of multiple spawning and describe properties of the ovary, and morphology of the egg capsule and the fully-formed offspring. The vitellogenic follicles in the ovary was $179.8{\pm}57.1$ (54~247) and can be classified into five size groups, which the last group of ova are considered as the moving to the capsule gland where fertilization and encapsulation of ova take place. The morphology of the egg capsule of R. pulchra is unique among the species of the family Rajidae and showed multi-embryo characteristics, having two to six yolks in each capsule. The adaptive morphological changes of larvae developing inside the egg capsule are described based on specimens extracted from the capsule.

Relationship between electrical stimulus strength and contraction force from the inside of small intestine (전기 자극 강도에 따른 소장 내부에서의 수축력 관계)

  • Woo, S.H.;Kim, T.W.;Lee, J.H.;Park, H.J.;Moon, Y.K.;Won, C.H.;Lee, S.H.;Park, I.Y.;Cho, Jin-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.1-8
    • /
    • 2008
  • Recently, capsule endoscope was developed to observe small intestine in human body. However, the capsule does not have any locomotive ability, which reduces the benefit of the capsule endoscope. Many researches have done to give locomotion to the capsule, still it consumes too much power to generate the motion by small battery. One of the moving method is electrical stimulus that consumes less power than many methods. The electrical stimulus method causes contraction in the small intestine, and it moves the capsule. Some of papers showed it is possible to guide the capsule by electrical stimulus, however the relationship between electrical stimulus at the mucous and contraction force in the small intestine is not reported, yet. In this paper, the mucous in the small intestine was stimulated, and measured the contraction force in the small intestine is shown. The result shows, the relationship between electrical stimulus parameters (voltage, duration) and contraction force. Also, equation between electrical stimulus parameters and contraction force is roughly induced.

Pressure Drop and Vibration Characteristics of the Capsule with the Modification of Bottom Structures (캡슐 하단부 구조변경에 따른 압력강하 및 진동특성)

  • Choi, M.H.;Choo, K.N.;Cho, M.S.;Kim, B.G.
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.12 s.105
    • /
    • pp.1370-1377
    • /
    • 2005
  • The bottom structure of an instrumented capsule is a part which is joined at the receptacle of the flow tube in the reactor in-core. A geometrical change of the bottom structure has an effect on the pressure drop and the vibration of the capsule. The out-pile test to evaluate the structural integrity of the material capsule called 04M-17U was performed by using a single channel and a half core test loop. From the pressure drop test, the optimized diameter of the cone shape's bottom structure which satisfies HANARO's flow requirement (19.6 kg/s) is 71 mm. The maximum displacement of the capsule measured at the half core test loop is lower than 1.0 mm. From the analysis results, it is found that the test hole will not be interfered with near the flow tubes because its displacement due to the cooling water is very small at 0.072 mm. The fundamental frequency of the capsule under water is 9.64 Hz. It is expected that the resonance between the capsule and the fluid flow due to the cooling water in HANARO's in-core will not occur. Also, the new bottom structure of a solid cone shape with 71 mm in diameter will be applicable to the material and special capsules in the future.

Technical Characteristics and Trends of Capsule Endoscope (캡슐 내시경의 기술적 특징과 동향)

  • Kim, Ki-Yun;Won, Kyung-Hoon;Choi, Hyung-Jin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.4C
    • /
    • pp.329-337
    • /
    • 2012
  • Capsule Endoscope(CE) is a capsule-shaped electronic device which can examine the lesions in digestive tract of human body. Recently the medical procedure using capsule endoscope is receiving great attention to both doctors and patients, since the conventional push-typed endoscope using cables brings great pain and fear to the patients. The technique was firstly available in 2000 and is based on a convergence techniques among BT(Bio Technology), IT(Information Technology), and NT(Nano Technology). The device consists of an optical parts including LEDs(Light Emitting Diodes), an image sensor, a communication module and a power module. Capsule endoscope is the embodiment of the state-of-the art technology and requires key technologies in the various engineering fields. Therefore, in this paper, we introduce the composition of the capsule endoscope system, and compare the communication method between RF(Radio Frequency) communication and HBC(Human Body Communication), which are typically used for data transmission in the capsule endoscope. Furthermore, we analyze the specification of commercialized capsule endoscopes and present the future developments and technical challenges.

Pressure Drop and Vibration Characteristics of the Capsule with the Modification of Bottom Structures (캡슐 하단부 구조변경에 따른 압력강하 및 진동특성)

  • Choi, M.H.;Choo, K.N.;Cho, M.S.;Lee, K.H.;Kim, B.G.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.782-787
    • /
    • 2005
  • The bottom structure of an instrumented capsule is a part which is joined at the receptacle of the flow tube in the reactor in-core. A geometrical change or the bottom structure has an effect on the pressure drop and the vibration of the capsule. The out-pile test to evaluate the structural Integrity of the material capsule called 04M-l7U was performed by using a single channel and a half core test loop. From the pressure drop test, the optimized diameter of the cone shape's bottom structure which satisfies HANARO's flow requirement (19 6 kg/s) is 71 mm. The maximum displacement of the capsule measured at the half core test loop is lower than 1.0 mm. From the analysis results, it is found that the test hole will not be interfered with near the flow tubes because its displacement due to the cooling water is very small at 0.072 mm. The fundamental frequency of the capsule under water is 9.64 Hz. It is expected that the resonance between the capsule and the fluid flow due to the cooling water in HANARO's In-core will not occur. Also, the new bottom structure of a solid cone shape with 71 mm in diameter will be applicable to the material and special capsules in the future.

  • PDF

Influence of the Mars atmosphere model on aerodynamics of an entry capsule

  • Zuppardi, Gennaro
    • Advances in aircraft and spacecraft science
    • /
    • v.6 no.3
    • /
    • pp.239-256
    • /
    • 2019
  • This study develops a dual purpose: i) evaluating the effects of two different Mars atmosphere models (NASA Glenn and GRAM-2001) on aerodynamics of a capsule (Pathfinder) entering the Mars atmosphere, ii) verifying the feasibility of evaluating the ambient density and pressure by means of the methods by McLaughlin and Cassanto, respectively and therefore to re-build the values provided by the models. The method by McLaughlin relies on the evaluation of the capsule drag coefficient, the method by Cassanto relies on the measurement of pressure at a point on the capsule surface in aerodynamic shadow. The study has been carried out computationally by means of: i) a code integrating the equations of dynamics of the capsule for the computation of the entry trajectory, ii) a DSMC code for the solution of the flow field around the capsule in the altitude interval 50-100 km. The models show consistent differences at altitudes higher than about 40 km. It seems that the GRAM-2001 model is more reliable than the NASA Glenn model. In fact, the NASA Glenn model produces, at high altitude, temperatures that seem to be too low compared with those from the GRAM-2001 model and correspondingly very different aerodynamic conditions in terms of Mach, Reynolds and Knudsen numbers. This produces pretty different capsule drag coefficients by the two models as well as pressure on its surface, making not feasible neither the method by McLaughlin nor that by Cassanto, until a single, reliable model of the Mars atmosphere is not established. The present study verified that the implementation of the Cassanto method in Mars atmosphere should rely (such as it is currently) on pressure obtained experimentally in ground facilities.

Controlled Release of Propranolol.HCI from Hollow Type Suppositories Inserted Polyvinyl Alcohol Hydrogel Capsule (폴리비닐알코올 하이드로겔 캅셀을 삽입한 중공좌제로부터 염산프로프라놀롤의 조절 방출)

  • 진선경;문이렌;구영순
    • YAKHAK HOEJI
    • /
    • v.43 no.2
    • /
    • pp.150-159
    • /
    • 1999
  • Hollow type suppositories inserted polyvinyl alcohol (PVA) hydrogel capsule containing propranolol·HCI (PPH) were prepared using different bases, polyethylene glycol (PEG), Witepsol H-15 (WH-15) and Witepsol W-35 (WW-35) to improve the controlled release of PPH. The release of PPH from the hollow type suppository inserted PVA hydrogel capsule was retarded than that from PEG, WH-15, or WW-35 hollow type suppositories in rat rectal cavity. When the suppositories were administered to rats, the controlled release of PPH was proved by the plasma concentration-time-profiles of PPH. No significant difference (p〈0.05) among the three different hollow type suppositories was observed in terms of AUC and MRT of PPH. WH-15 hollow type suppository inserted 12% of PVA hydrogel capsule caused irritation to rat rectal mucosa. However, the WH-15 hollow type suppository inserted PVA hydrogel capsule caused no severe irritation on rectal mucosa. The application of the hollow type suppositories using PVA in sustained rectal delivery of drugs might be feasible.

  • PDF