• Title/Summary/Keyword: capillary electrophoresis

Search Result 174, Processing Time 0.025 seconds

Determination of Water-Soluble Vitamins by Free Solution Capillary Electrophoresis (모세관전기영동을 이용한 수용성비타민의 분석)

  • Choi, One-Kyun;Jo, Jae-Sun
    • Korean Journal of Food Science and Technology
    • /
    • v.26 no.1
    • /
    • pp.18-22
    • /
    • 1994
  • This study was designed to investigate the method of the simultaneous determination of water-soluble vitamins (thiamine, ascorbic acid, riboflavin, folic acid, cyanocobalamine, pyridoxin, nicotinic acid) by free soloution capillary electrophoresis. Factors affecting on the separation were pH of the buffer, applied voltage and temperature. On-column detection at 254 nm allowed accurate and reproducible determination of these compounds. All these compounds were separated within ca. 8 min with fused silica capillary at 20 kV.

  • PDF

A proposal of new electronics device;micro-total analysis system for capillary electrophoresis

  • Oshige, Seisho;Aoyama, T.;Kambe, J.;Nagashima, U.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.579-581
    • /
    • 2004
  • We wish to develop micro-total analysis system (TAS) on a chip, and to make a trial approach to solve the important problem that is to detect ions separated by the electric field. We propose an idea, which is as for rotational motions of dipolar ions, which are affected by the ion atmosphere in outer regions. This is a new kind of the ion-sensitive field effect transistor (ISFET). We wish to develop the ISFET chips, and give more effective, fast and sensitive, capillary electrophoresis is designed in near future.

  • PDF

Analysis of Water-soluble Vitamins in Pharmaceutical Products by Capillary Electrophoresis (모세관 전기영동법을 이용한 제제중의 수용성 비타민 분석)

  • Lee, Jong-Jin;Moon, Dong-Cheul;Lee, Kong-Joo
    • YAKHAK HOEJI
    • /
    • v.38 no.1
    • /
    • pp.38-45
    • /
    • 1994
  • An analytical method using capillary electrophoresis (CE) was developed for quantitation of water soluble vitamin contents in various vitamin products. The method includes the optimization of separation of 11 water soluble vitamins changing the micellar concentration and pH of running buffer, applied voltage and sample preparation. Best resolution was obtained with 25 mM phosphate buffer (pH=8.0) containing 50 mM sodium dodecyl sulphate (SDS) as micellar phase. At optimum condition, water soluble vitamins were determined in orange juice and vitamin products such as vitamin C pulvis, vitamin injection, coated multivitamin tablet. The quantitative analysis of water soluble vitamins with CE was suitable for quality control of pharmaceutical products with sound reproducibility.

  • PDF

Analysis of Inorganic Anions in Various Drinking Waters by Capillary Electrophoresis

  • Choi, One-Kyun;Cho, Jae-Sun
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.835-841
    • /
    • 1995
  • The quantitation of inorganic anions in various drinking waters were investigated using capillary electrophoresis(CE) and the results were compared with ion chromatography(IC). With CE, in contrast to IC, was demonstrated rapid analysis, good efficiency, a low detection limit and the low comsumption of a solvent and samples. CE analysis was used 5 mM sodium chromate(pH 8.0) containing 20 mM tetraalkylammoniumbromide at -25kV applied voltage with indirect UV detection at 254 nm. This results in exceedingly short analysis time within 3 min. with efficiencies approaching 200,000 theoretical plates. The coefficients of variants of migration time are less than 0.8% and those of peak area are less than 2.3%. Detection limits for quantitative determination were 300 ppb-50 ppm level. These optimum conditions are applicable to various samples without pretreatment.

  • PDF

Determination of Stability Constants for $\beta$-Blocker and Carboxymethyl-$\beta$-cyclodextrin Complexes by Capillary Electrophoresis (모세관 전기영동법을 이용한 베타차단제-시클로덱스트린 포접화합물의 안정도상수 결정)

  • 박경래;임환미;뉴엔티퐁;김경호;강종성
    • YAKHAK HOEJI
    • /
    • v.47 no.4
    • /
    • pp.200-205
    • /
    • 2003
  • The stability constants for the inclusion complexes between carboxymethyl-$\beta$-cyclodextrin (CM-$\beta$-CD) and five $\beta$-blockers, such as atenolol (ATE), bisoprolol (BIS), metoprolol (MET), pindolol (PIN) and propranolol (PRO) were determined by capillary electrophoresis. The magnitude of stability was decreased as following order; PRO>MET>BIS>ATE>PIN. Among them PRO showed the highest affinity towards CM-$\beta$-CD with stability constants of 383 and 371 $M^{-l}$ for (R)- and (S)-enantiomer, respectively. PIN enantiomers showed the lowest stability towards CM-$\beta$-CD, while the selectivity between (R)- and (S)-enantiomer was higher than any other tested $\beta$-blocker.r.

PDMS/Glass Based DNA Microbiochip for Restriction Enzyme Reaction and Electrophoresis Detection (DNA의 제한효소 반응 및 전기영동 검출용 PDMS/유리 마이크로바이오칩)

  • Choi Joon-Young;Ahn Yoo Min;Hwang Seung-Yong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.1 s.244
    • /
    • pp.26-31
    • /
    • 2006
  • This paper reports low-cost PDMS/glass based DNA microbiochip for the restriction enzyme reaction and its products detection using the capillary electrophoresis. The microbiochip ($25mm{\times}75mm$) has the heater integrated reactor ($5{\mu}{\ell}$) for DNA restriction enzyme reaction at $37^{\circ}C$ and the microchannel ($80\;{\mu}m{\times}100\;{\mu}m{\times}58mm$) for the capillary electrophoresis detection. It is experimentally confirmed that the digestion of the plasmid ($pGEM^{(R)}-4Z$) by the enzyme (Hind III and Sca I) is performed for less than 10 min and its electrophoresis detection is able to sequentially on the fabricated microbiochip.

Analysis of cyanide free electroless Au plating solution by capillary elecrophoresis (캐피라리 전기 영동법에 의한 비시안 무전해 Au 도금액의 분석)

  • Han, Jaeho;Kim, DongHyun
    • Journal of the Korean institute of surface engineering
    • /
    • v.55 no.2
    • /
    • pp.120-132
    • /
    • 2022
  • In the non-cyanide-based electroless Au plating solution using thiomalic acid as a complexing agent and aminoethanethiol as a reducing agent, analysis of each component constituting the plating solution is essential for the analysis of the reaction mechanism. And component analysis in the plating solution is important for monitoring component changes in the plating process and optimizing the management method. Capillary Electrophoresis (CE) method is rapid, sensitive and quantitative and could be readily applied to analysis of Aun+ ion, complexing agent and reducing agent in electroless Au plating solution. In this study, the capillary electrophoresis method was used to analyze each component in the electroless Au plating solution in order to elucidate the complex bonding form and the plating mechanism of the non-cyanide-based electroless Au plating bath. The purpose of this study was to establish data for optimizing the monitoring and management method of plating solution components to improve the uniformity of precipitation and stability. As a result, it was confirmed that the analysis of thiomalic acid as a complexing agent and Aun+ ions and the analysis of aminoethanethiol as a reducing agent were possible by capillary electrophoresis. In the newly developed non-cyanide-based electroless Au plating solution, it was confirmed that Aun+ ions exist in the form of Au+ having a charge of +1, and that thiomalic acid and Au+ are combined in a molar ratio of 2 : 1. In addition, it was confirmed that aminoethanethiol can form a complex by combining with Au+ ions depending on conditions as well as acting as a reducing agent.

Determinaton of Chloride Ion Captured into Strong NaOH Solution from Chimney by Capillary Electrophoresis (모세관 전지영동법에 의한 굴뚝에서 포집된 NaOH 용액속의 염소이온의 측정)

  • 임인덕;성용익;김양선;임흥빈
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.3
    • /
    • pp.327-333
    • /
    • 1999
  • Determination of chloride ion in concentrated NaOH solution by capillary electrophoresis has been studied. The analysis was performed by indirect UV absorption detection using chromate buffer at 254nm. The matrix effect of the sample has been observed so that the sensitivity in strong NaOH solutaion has decreased up to 10% of that in distilled water. The pH effect of the sample on the sensitivity of CE peaks has been investigated. The method for increasing the sensitivity have been investigated and the optimum pH and concentration of the buffer were 7.5 and 10mM, respectively. A cationic surfactant cetyltrimethylammonium bromide(CTAB), was added to a buffer solution in order to reverse the electroosmotic flow(EOF) in the capillary. This results in a short analysis time and better peak shapes. Using this optimum condition, the determination of chloride ion in real environmental sample has been performed, which is captured in strong NaOH absorbent prepared for absorbing gas from chimney. The standard addition method has been applied for the quantitative analysis, and it was obtained the good reproducibility.

  • PDF

Capillary Electrophoresis of Single-stranded DNA

  • Choi, Hyun-Ju;Kim, Yong-Seong
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.7
    • /
    • pp.943-947
    • /
    • 2003
  • We have studied the migration behavior of single-stranded DNA using capillary gel electrophoresis under various conditions. It was found that optimum electric fields should be less than 150 V/cm for the good tradeoff between the separation time and the resolution. It seems that the gel matrix with the combination of different polymer average molecular weights is important to extend the maximum readable DNA bases. The total gel concentration less than 3.1% in the mixed gel system showed good separation efficiency up to 600 bases. The best result was obtained with the poy(ethylene)oxide (PEO) gel concentration of 1.2% of Mr 8,000,000 and 1.8% of Mr 600,000. We observed that the capillary length between 50 cm to 100 cm (effective length) should be employed for the optimization between the total DNA migration time and the maximum readable length. A trizma base-boric acid-ethlyenediaminetetraacetic acid (EDTA) (TBE) buffer was commonly used for DNA sequencing, but we found that 3-[tris(hydroxymethyl)methyl amino]-1-propane sulfonic acid (TAPS) buffer worked as well for the single-stranded DNA separation. Especially, TAPS buffer showed a good resolution for very short DNA bases (1 to 30 bases).

Determination of Pd(II) and Pt(II) Metal Cyano Complexes Using Capillary Electrophoresis

  • Lee, Hue-Jin;Lee, Sang-Ho;Chung, Koo-Soon;Lee, Kwang-Woo
    • Bulletin of the Korean Chemical Society
    • /
    • v.15 no.11
    • /
    • pp.945-949
    • /
    • 1994
  • Mixtures of cyano complexes of palladium(II) and platinum(II) were separated by capillary electrophoresis using a fused silica capillary as a separation column and 30 mM phosphate buffer (pH 7) containing 15 wt. % acetonitrile as a running buffer. By virtue of the high ionic mobilities of the negatively charged cyano complexes of Pd(II) and Pt(II), they were separated using a cathodic injection and anodic detection scheme. The metal complexes eluted through the capillary were detected by direct UV absorption at 214 nm. A linear relationship between peak area and concentration was obtained for both ions and the detection limit was lower than $10^{-14}$ mole. The proposed method was applied to real sample, e.g., anode slime obtained from an electrolytic copper refinary, as a method for the simultaneous determination of palladium and platinum.