• 제목/요약/키워드: capillary design

검색결과 130건 처리시간 0.024초

마이크로 모세관 유동 해석을 위한 CFD-VOF 모텔 응용 (Application of CFD-VOF Model to Autonomous Microfluidic Capillary System)

  • 정자훈;임예훈;한상필;석지원;김영득
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2004년도 춘계 학술대회논문집
    • /
    • pp.224-229
    • /
    • 2004
  • The objective of this work is not only to perform feasibility studies on the CFD (computational fluid dynamics) analysis for the capillary system design but also to provide an enhanced understanding of the autonomous capillary flow. The capillary flow is evaluated by means of the commercial CFD software of FLUENT, which includes the VOF (volume-of-fluid) model for multiphase flow analysis. The effect of wall adhesion at fluid interfaces in contact with rigid boundaries is considered in terms of static contact angle. Feasibility studies are first performed, including mesh-resolution influence on pressure profile, which has a sudden increase at the liquid/gas interface. Then we perform both 2D and 3D simulations and examine the transient nature of the capillary flow. Analytical solutions are also derived for simple cases and compared with numerical results. Through this work, essential information on the capillary system design is brought out. Our efforts and initial success in numerical description of the microfluidic capillary flows enhance the fundamental understanding of the autonomous capillary flow and will eventually pave the road for full-scale, computer-aided design of microfluidic networks.

  • PDF

Continuous Viscosity Measurement of Non-Newtonian Fluids over a Range of Shear Rates Using a Mass-Detecting Capillary Viscometer

  • Sehyun Shin;Keum, Do-Young
    • Journal of Mechanical Science and Technology
    • /
    • 제16권2호
    • /
    • pp.255-261
    • /
    • 2002
  • A newly designed mass-detecting capillary viscometer uses a novel concept to continuously measure non-Newtonian fluids viscosity over a range of shear rates. A single measurement of liquid-mass variation with time replaces the now rate and pressure drop measurements that are usually required by capillary tube viscometers. Using a load cell and a capillary, we measured change in the mass flow rate through a capillary tube with respect to the time, m(t), from which viscosity and shear rate were mathematically calculated. For aqueous polymer solutions, excellent agreement was found between the results from the mass-detecting capillary viscometer and those from a commercially available rotating viscometer. This new method overcomes the drawbacks of conventional capillary viscometers meassuring non-Newtonian fluid viscosity. First, the mass-detecting capillary viscometer can accurately and consistently measure non -Newtonian viscosity over a wide range of shear rate extending as low as 1 s$\^$-1/. Second, this design provides simplicity (i. e., ease of operation, no moving parts), and low cost.

모세관 변경에 따른 가정용 소형 멀티 냉동시스템의 성능에 관한 연구 (A Study on the Performance of a Domestic Small Multi Refrigerator According to a Capillary Tube Change)

  • 김상욱;이무연
    • 대한기계학회논문집B
    • /
    • 제29권6호
    • /
    • pp.763-771
    • /
    • 2005
  • This paper is an experimental study on the performance according to a capillary tube diameter and length in a domestic small multi refrigerator[kimchi refrigerator]. Pressure drop in a capillary tube is predicted by theoretical analysis and experimental method as the reduction of capillary tube diameter from 0.74 to 0.6 mm. The differences between experimental results and analytical results are mainly caused by friction factor in a capillary tube. Because there are no adequate equations used to calculate pressure drop of capillary tube diameter under 1.0mm. The empirical equations necessary for interpretation of capillary tube were derived from capillary tube test results data using curve fitting method. This study shows that the optimized designs of system, which is capillary tube length and refrigerant charge amount, are 2000mm, 83g at the capillary tube diameter 0.6mm and 3000mm, 73g at the capillary tube diameter 0.74mm. And capillary design tools and system matching techniques necessary for development of the kimchi refrigerator were also developed through this study.

스크린메쉬윅 히트파이프에서 윅의 기공율변화에 따른 열수송한계의 이론적 고찰 (Theoretical Analysis of Heat Transportation Limitation by Porosity of Wick in Screen Mesh Wick Heat Pipe)

  • 이기우;박기호;전원표;이욱현
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.1-6
    • /
    • 2003
  • The purpose of the present study is to investigate the capillary heat transportation limitation in heat pipe according to the change of screen mesh wick porosity. Diameter of pipe was 6 mm, and mesh numbers are 100, 150, 200 and 250 and water was selected as a working fluid. According to the change of wick porosity and mesh number, the capillary pressure, pumping pressure, liquid friction coefficient in wick, vapor friction coefficient, and capillary heat transportation limitation are analyzed by theoretical design method of a heat pipe. As some results, the capillary heat transportation limitation in screen mesh wick heat pipe is largely affected by wick porosity and mesh number.

  • PDF

캐필러리 레오미터를 이용한 고분자의 PvT 측정 방법 (PvT measruement method of polymer using capillary rheometer)

  • 김선경;박재은
    • Design & Manufacturing
    • /
    • 제14권3호
    • /
    • pp.31-36
    • /
    • 2020
  • In injection molding processes, the property of molten resin should be characterized accurately. Among several properties, the PvT state is the most important one, since it affects the shrinkage, warpage, molded weight, and the part density. Thus, the PvT data is crucial to the simulation of the injection molding process. This work shows how such a measurement can be performed for a semi-crystalline and amorphous polymers. The PvT measurement has been conducted using a capillary rheometer using a suitable accessory that blocks the capillary. The results have shown that the PvT data can be obtained using such a rheometer and then the PvT coefficients of the Tait equation can be reached.

$CO_2$ 단열 모세관내 유동 특성 (Flow Characteristics in an Adiabatic Capillary Tube of Carbon Dioxide)

  • 노건상;손창효
    • 한국수소및신에너지학회논문집
    • /
    • 제19권6호
    • /
    • pp.537-544
    • /
    • 2008
  • In this paper, flow characteristics of an adiabatic capillary tube in a transcritical $CO_2$ have been investigated employing the homogeneous model. The model is based on fundamental equations of mass, energy and momentum which are solved simultaneously. Two friction factors(Churchill) and viscosity(McAdams) are comparatively used to investigate the flow characteristics. Supercritical and subcritical thermodynamic and transport properties of $CO_2$ are calculated employing EES property code. Flow characteristics analysis of $CO_2$ adiabatic capillary tube is presented to offer the basic design data for the operating parameters. The operating parameters considered in this study include inlet temperature and pressure of an adiabatic capillary tube, evaporating temperature and inner diameter tube. The main results were summarized as follows : inlet temperature and pressure of an adiabatic capillary tube, evaporating temperature, mass flowrate and inner diameter of $CO_2$ adiabatic capillary tube have an effect on length of an adiabatic capillary tube.

소형 모세관식 알카리 금속 열전변환소자의 사이클해석 (Cycle Analysis of an Alkali Metal Thermo-Electric Converter for Small Capillary Type)

  • 윤석구;구재현;이재근;전중 경
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.956-961
    • /
    • 2000
  • This paper describes the design of a small size Alkali Metal Thermal to Electric Converter (AMTEC) which employs a capillary structure for recirculating sodium working fluid. The cycle is based on the simple and small capillary type ${\beta}"$ -alumina and wick tube element. The proposed cell consists of the 37 conversion elements with capillary tube of $50{\mu}m$ in diameter and the sealed cylindrical vessel of 22mm in outer diameter. Results on the cycle analysis of sodium flow and heat transfer in the cell showed that the expected power output was 4.65W and the conversion efficiency was 19% for the source temperature of 900K.

  • PDF

점탄성유체의 Capillary Breakup 가시화 및 신장유변물성 측정 (Capillary Breakup of Viscoelastic Fluid and its Extensional Rheology)

  • 전현우;최찬혁;김병훈;박진수
    • 한국가시화정보학회지
    • /
    • 제19권1호
    • /
    • pp.81-87
    • /
    • 2021
  • Extensional flow of viscoelastic fluids is widely utilized in various industrial processes such as electrospinning, 3D printing and plastic injection molding. Extensional rheological properties, such as apparent viscosity and relaxation time, play an important role in the design and evaluation of the viscoelastic fluid-involved processes. In this work, we propose a lab-built capillary breakup extensional rheometer (CaBER) based on flow image processing to investigate the capillary breakup of polyethylene oxide (PEO) solution and its extensional rheological properties. We found that the apparent extensional viscosity and extensional relaxation time of the PEO solution are independent of the strike time. The proposed CaBER is expected to be applied to characterization of the extensional rheological properties of viscoelastic fluids at low cost with high precision.

모세유관 바닥복사 냉·난방 시스템의 성능평가 (Performance Evaluation of the Capillary Tube Radiant Floor Cooling & Heating System)

  • 서유진;김태연;이승복
    • KIEAE Journal
    • /
    • 제12권4호
    • /
    • pp.89-95
    • /
    • 2012
  • At present, many countries are trying to reduce green gas emissions to mitigate the effects of these gases on climate change. Year after year, there have been efforts to cut energy use for heating and cooling. Heating and cooling systems, common in all forms of housing, are increasing due to the constant supply of new housing resulting from improvements in economic growth and the quality of life. Thus, studies related to the design of cooling and heating systems to improve energy efficiency are expanding. Among the new designs, radiant floor cooling and heating systems which use capillary tubes are becoming viable means of reducing energy use. Radiant floor cooling and heating systems which use capillary tubes are creative and sustainable systems in which cool and hot water is circulated into capillary tube which has small diameter. In this study, the cooling and heating performance of this type of capillary tube system is investigated in an experimental study and a simulation using TRNSYS. The results of the experimental study show that under a peak load, a capillary tube radiant floor cooling system using geothermal energy can achieve desired indoor temperature without an additional heat source. The set room air temperature is maintained while the floor surface temperature, PMV and PPD remain within the comfort range. Also, this system is more economic than a packaged air conditioner system due to its higher COP. The results of the simulation show that the capillary tube radiant floor heating system maintains set temperature more stable than a PB pipe radiant floor heating system due to its lower supply temperature of hot water. In terms of energy consumption, the capillary tube radiant floor heating system is more efficient than the PB pipe radiant floor heating system.