• 제목/요약/키워드: capacity design

검색결과 5,603건 처리시간 0.029초

전철용 직류변전소의 최적 위치 및 용량 설계에 관한 연구 (A Study on Design of Optimal Location and Capacity of DC Substation for Mass Transit System)

  • 김종구;이상동;백병산;이현두;이준엽
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 B
    • /
    • pp.398-401
    • /
    • 2000
  • This paper describes the design of optimal location and capacity of DC substation for Mass Transit System. Three factors are considered for the design i.e. substation arrangements, line configuration and substation power capacity. In this study, we considered all of them for capacity calculation of power supply system for MTS. At first, DC-fed-traction system is introduced on an outline, a characteristics of train and fed network, and design method of substation arrangements. Optimal design procedures are described, and program for capacity calculation of the system is presented. In addition, the computer simulated results are compared with the conventional simple calculation method.

  • PDF

이력형 감쇠장치를 이용한 내진보강 예비설계절차 (A Preliminary Design Procedure for Seismic Retrofit Using Hysteretic Dampers)

  • 정국기;유은종
    • 한국지진공학회논문집
    • /
    • 제26권2호
    • /
    • pp.59-69
    • /
    • 2022
  • The use of dampers is being considered a means to improve the seismic performance of buildings. It may take considerable time and effort to find an optimal design solution since repeated three-dimensional nonlinear time history analyses are required. Therefore, a preliminary design procedure for seismic retrofit using hysteretic dampers was proposed in this study. In the proposed procedure, the amount of retrofit (required number of dampers) is estimated from the capacity curve of the building before retrofit and allowable story drift of the building. In combining the capacity curves of the building and the dampers, the deformation demand for the dampers can be easily checked against their deformation capacity. The equations to transform the device displacement to roof displacement for the combination of capacity curves are developed. The proposed procedure was applied to the seismic retrofit design of sample buildings. The study found that the estimated capacity curve was very close to the actual capacity curve obtained from the pushover analysis, which can determine an appropriate configuration to meet the required seismic performance.

차두시간분포 분석을 통한 고속도로 설계용량 산정모형의 개발 (Freeway Design Capacity Estimation through the Analysis of Time Headway Distribution)

  • 김점산;박창호
    • 대한토목학회논문집
    • /
    • 제26권2D호
    • /
    • pp.251-258
    • /
    • 2006
  • 본 연구에서는 개별차량의 차두시간분포 분석을 통해 고속도로 설계용량 산정모형을 개발하였으며 연구결과를 요약하면 다음과 같다. 교통류 기본관계와 차두시간 분포특성을 분석한 결과, 1) 개별차량 자료로부터 작성한 속도-교통량 관계는 선형을 이루지 않고 상당한 편차가 있는 분포를 이루고 있었으며, 2) 속도별 차두시간의 통계적 분포는 Pearson type V 분포의 형태로 추정하였을 경우 통계적 검정값이 가장 우수하였다. 새로운 고속도로 설계용량 산정모형은 기존 미국 도로용량편람의 용량의 정의에 본 연구의 결과인 속도별 최소차두시간의 통계적 정의를 포함시킴으로써 개발하였다. 새로운 고속도로 설계용량 산정모형에 의해 설계속도별로 산정한 용량수준을 기존의 용량편람에서 제시한 용량과 비교한 결과, 본 연구에서 제시한 도로설계 시 기준용량은 설계속도 80km/h 이하에서는 기존 용량편람보다 낮게, 설계속도 106km/h 이상에서는 기존 용량편람보다 높게 평가되었다. 더불어 본 연구 결과와 기존 용량편람의 큰 차이점은 용량을 확률분포로 정의함으로써 도로 설계 시 용량수준을 유연하게 적용할 수 있다는 사실이다. 다시 말해 본 연구는 도로설계 시 차로수 산정에 있어 기존의 단 한대의 추가 수요가 발생하더라도 한 차로를 추가하여야 하는 비효용에 대한 이론적 반론을 제시하고 있다.

CAD에 의한 엑스카 베이터(excavator)의 굴삭능력 향상에 관한 연구 (A study on the improvement of the digging load capacity of an excavator by CAD technique)

  • 박찬기;이장무
    • 오토저널
    • /
    • 제4권2호
    • /
    • pp.24-34
    • /
    • 1982
  • In order to improve the digging load capacity of a domestic excavator model. computer aided design(CAD) technique was applied to the optimum design of the excavator boom. From this study, the digging load capacity of both the bucket cylinder and the dipperstick cylinder could be made about same and the overall digging load capacity could be increased by about 50%, also, the computer program package developed in this study can be flexibly applied to the design of other construction machines by changing and/or adding a few subprograms and the input data.

  • PDF

역량스펙트럼법에 의한 교량 구조물의 내진성능평가 (Seismic Capacity Evaluation of Bridge Structure using Capacity Spectrum Method)

  • 박연수;오백만;박철웅;서병철
    • 한국지진공학회논문집
    • /
    • 제7권5호
    • /
    • pp.67-73
    • /
    • 2003
  • 현 도로교의 내진해석은 구조물이 하중 이상의 강도를 갖도록 하는 하중기반해석법에 근거하고 있다. 본 연구에서는 이러한 하중기반해석의 대안책으로 구조물의 성능평가 대상을 변위로 하는 변위기반해석의 일종인 역량스펙트럼법을 제시하였다. 하중기반해석에서 내진설계가 수행되어진 기존 철근콘크리트 교각에 대하여 역량스펙트럼법에 의한 내진성능을 평가하였다. 그 결과, 역량스펙트럼법은 간편하고 신속하게 구조물의 비탄성 응답을 현실적으로 평가할 수 있었으며 비탄성 응답을 일으키는 다양한 지반운동 수준에 대해 구조물에 발생하는 변위를 평가할 수 있었고, 기존 구조물의 내진성능에 대한 평가나 신설구조물의 성능목표에 대한 설계검증에 효율적으로 적용 가능하였다.

에너지 소산능력을 고려한 전단벽의 내진설계 (Earthquake Design Method for Structural Walls Based on Energy Dissipation Capacity)

  • 박홍근;엄태성
    • 한국지진공학회논문집
    • /
    • 제7권6호
    • /
    • pp.25-34
    • /
    • 2003
  • 최근 능력스펙트럼법, 직접변위기초설계법 등과 같은 성능에 기초한 내진 평가/설계법이 개발되어 사용되고 있다. 이들 방법은 구조물의 비선형 주기거동에 의한 에너지 소산능력을 고려함에 있어 부정확한 경험식에 의존하는 한계를 보이고 있다. 한편, 최근 연구에서 휨지배 철근콘크리트 부재에 대하여 여러 설계변수의 영향을 고려하여 주기거동에 의한 에너지 소산능력을 정확히 평가할 수 있는 방법이 개발되었다. 본 연구에서는 에너지 소산능력을 고려한 내진설계법에 대한 기초적인 연구로서, 최근 연구에서 개발된 에너지 소산능력 산정법을 이용한 철근콘크리트 전단벽 구조의 내진설계법을 개발하여, 기존의 내진설계법과 비교하였다. 제안된 설계법에서는 단면의 크기 및 형상, 축력, 철근비, 배근형태, 연성도 등과 같은 다양한 설계변수에 따른 에너지 소산능력의 변화를 정확히 고려하여 설계할 수 있다.

Internal force monitoring design of long span bridges based on ultimate bearing capacity ratios of structural components

  • Hu, Ke;Xie, Zheng;Wang, Zuo-Cai;Ren, Wei-Xin;Chen, Lei-Ke
    • Structural Monitoring and Maintenance
    • /
    • 제5권1호
    • /
    • pp.93-110
    • /
    • 2018
  • In order to provide a novel strategy for long-span bridge health monitoring system design, this paper proposes a novel ultimate bearing capacity ratios based bridge internal force monitoring design method. The bridge ultimate bearing capacity analysis theories are briefly described. Then, based on the ultimate bearing capacity of the structural component, the component ultimate bearing capacity ratio, the uniformity of ultimate bearing capacity ratio, and the reference of component ultimate bearing capacity ratio are defined. Based on the defined indices, the high bearing components can then be found, and the internal force monitoring system can be designed. Finally, the proposed method is applied to the bridge health monitoring system design of the second highway bridge of Wuhu Yangtze river. Through the ultimate bearing capacity analysis of the bridge in eight load conditions, the high bearing components are found based on the proposed method. The bridge internal force monitoring system is then preliminary designed. The results show that the proposed method can provide quantitative criteria for sensors layout. The monitoring components based on the proposed method are consistent with the actual failure process of the bridge, and can reduce the monitoring of low bearing components. For the second highway bridge of Wuhu Yangtze river, only 59 components are designed to be monitored their internal forces. Therefore, the bridge internal force monitoring system based on the ultimate bearing capacity ratio can decrease the number of monitored components and the cost of the whole monitoring system.

철도노반 침하저감을 위한 토목섬유 감쌈 쇄석말뚝 설계방안 고찰 (A Study on Design Method of Geogrid Encased Stone Colum for Settlement Reduction in Railroad)

  • 이대영
    • 한국지반신소재학회논문집
    • /
    • 제13권3호
    • /
    • pp.31-38
    • /
    • 2014
  • 지오그리드 감쌈 쇄석말뚝 공법은 지오그리드의 인장구속효과로 인해 연약지반에 시공된 쇄석말뚝의 지지력을 증가시켜주는 공법이다. 본 연구에서는 토목섬유 감쌈 쇄석말뚝(GESC)공법의 설계에 적용할 수 있는 토목섬유 인장저항력과 극한지지력을 산정할 수 있는 합리적인 설계법을 제안하였다. 제안된 설계방법의 적적성을 평가하기 위해 부산 경전선 연약지반 시험시공 결과로부터 산출된 GESC의 극한지지력과 설계법에의해 산정된 극한지지력을 비교 검증하였다. 연구결과 GESC 설계법에 의해 산정된 지지력이 현장시험의 지지력 보다 크게 나타나는 것으로 검토되었다.

전철용 직류변전소의 최적용량설계에 관한 연구 (A Study on Optimal Design of DC Substation Capacity for Mass Transit System)

  • 김종구;이상동;백병산;이현두;이준엽
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.1405-1407
    • /
    • 2000
  • This paper is on optimal design for DC substation capacity for Mass Transit System. Three factors are considered for the design i.e. substation arrangements, line configuration and substation power capacity. In this study, we discussed substation power capacity only. At first, DC-fed-traction system is introduced on an outline, a characteristics of train and fed network. Optimal design procedures is described, and modelling for DC-fed-traction system are presented. The circuit-solution method is presented by matrix formula. In order to simulate DC substation power capacity more closely to actual situations, we proposed the program.

  • PDF

Experimental seismic behavior of RC special-shaped column to steel beam connections with steel jacket

  • Hao, Jiashu;Ren, Qingying;Li, Xingqian;Zhang, Xizhi;Ding, Yongjun;Zhang, Shaohua
    • Steel and Composite Structures
    • /
    • 제45권1호
    • /
    • pp.101-118
    • /
    • 2022
  • The seismic performance of the reinforced concrete (RC) special-shaped column to steel beam connections with steel jacket used in the RC column to steel beam fabricated frame structures was investigated in this study. The three full-scale specimens were subjected to cyclic loading. The failure mode, ultimate bearing capacity, shear strength capacity, stiffness degradation, energy dissipation capacity, and strain distribution of the specimens were studied by varying the steel jacket thickness parameters. Test results indicate that the RC special-shaped column to steel beam connection with steel jacket is reliable and has excellent seismic performance. The hysteresis curve is full and has excellent energy dissipation capacity. The thickness of the steel jacket is an important parameter affecting the seismic performance of the proposed connections, and the shear strength capacity, ductility, and initial stiffness of the specimens improve with the increase in the thickness of the steel jacket. The calculation formula for the shear strength capacity of RC special-shaped column to steel beam connections with steel jacket is proposed on the basis of the experimental results and numerical simulation analysis. The theoretical values of the formula are in good agreement with the experimental values.