• Title/Summary/Keyword: capacitive sensor

Search Result 329, Processing Time 0.027 seconds

A Gap Sensor Design for Precision Stage (초정밀 스테이지용 변위 센서)

  • 김일해;김종혁;장동영
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.04a
    • /
    • pp.453-458
    • /
    • 2004
  • A capacitate sensor is a proper device for measuring high small displacement. General design parameters and procedure are discussed and a test sensor was built to have a measuring range of 100$\mu\textrm{m}$ and a sensitivity about 30nm. This sensor has too opposing electrode of comparably large area and has nominal gap distance about 150$\mu\textrm{m}$. So as to achieve a nano order displacement sensitivity, both sensor and target system have to be considered. This is important for the sensitivity can be achieved by minimizing a system total noise level in electronic type sensor application. Typical performance of the developed sensor is demonstrated in precision moving stage having 0.1$\mu\textrm{m}$ moving resolution.

  • PDF

An Inductive Position Sensor for Self-sensing Magnetic Suspension System (셀프센싱 자기 부상계를 위한 인덕턴스형 변위센서)

  • 윤형진;이상헌;백윤수
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1038-1041
    • /
    • 2003
  • The magnetic suspension system is used in many areas, because it has great advantages. such as no friction, no noise, no lubrication and so on, but it is a unstable system in natural. It must have a feedback control with the position is measured for a stable levitation. There are an eddy-current sensor, a capacitive sensor, an inductive sensor, and an optical sensor with a laser as the sensor which measures displacements without contact. Among them, an inductive sensor is made with lower price than others. And it has a good linearity. In this paper, a magnetic circuit leads a linear equation between an input as a displacement and an output as a voltage. Experiments establish that voltage change according to displacement is linear. This paper presents the preliminary study of an inductive position sensing for self-sensing magnetic suspension system.

  • PDF

Development of Capacitive Type Humidity Sensor using Polyimide as Sensing Layer (폴리이미드를 감지층으로 이용한 정전용량형 습도센서 개발)

  • Hong, Soung-Wook;Kim, Young-Min;Yoon, Young-Chul
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.12 no.4
    • /
    • pp.366-372
    • /
    • 2019
  • In this paper, we fabricated a capacitive humidity sensor with an IDT(Interdigitated) electrode using commercial polyimide containing fluorine, and its properties were measured and analyzed. First, in order to analyze the composition of commercial polyimide, EDS analysis was performed after patterning process on a silicon wafer. The area of the humidity sensor was $1.56{\times}1.66mm^2$, and the width of the electrode and the gap between the electrodes were $3{\mu}m$ each. The number of electrodes was 166 and the length of the electrode was 1.294mm for the sensitivity of the sensor. The fabricated sensor showed that the sensitivity was 24 fF/%RH, linearity <${\pm}2.5%RH$ and hysteresis <${\pm}4%RH$. As a result of measuring the capacitance value according to the frequency change, the capacitance vlaue decreased with increasing frequency. Capacitance deviations with 10kHz and 100kHz were measured as 0.3pF on average.

Implementation of Real-time Sedentary Posture Correction Cushion Using Capacitive Pressure Sensor Based on Conductive Textile

  • Kim, HoonKi;Park, HyungSoo;Oh, JiWon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.2
    • /
    • pp.153-161
    • /
    • 2022
  • Physical activities are decreasing and sitting time is increasing due to the automation, smartization, and intelligence of necessary household items throughout daily life. Recent healthcare studies have reported that the likelihood of obesity, diabetes, cardiovascular disease, and early death increases in proportion to sitting time. In this paper, we develop a sitting posture correction cushion in real time using capacitive pressure sensor based on conductive textile. It develops a pressure sensor using conductive textile, a key component of the posture correction cushion, and develops a low power-based pressure measurement circuit. It provides a function to transmit sensor values measured in real time to smartphones using BLE short-range wireless communication on the posture correction cushion, and develops a mobile application to check the condition of the sitting posture through these sensor values. In the mobile app, you can visualize your sitting posture and check it in real time, and if you keep it in the wrong posture for a certain period of time, you can notify it through an alarm. In addition, it is possible to visualize the sitting time and posture accuracy in a graph. Through the correction cushion in this paper, we experiment with how effective it is to correct the user's posture by recognizing the user's sitting posture, and present differentiation and excellence compared to other product.

RLSE Based Batteryless Telemetry Capacitive Sensor System

  • Lee, Joon-Tark;Kim, Kyung-Yup
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2003.09a
    • /
    • pp.318-321
    • /
    • 2003
  • In case, sensor system performs where it is difficult to access physically and it is in the poor environment, it is limited to communicate by using wire and installing power module in sensor system. In this paper, it suggests how information is obtained from telemetry sensor by means of inductive coupling without battery. Comparing with the telemetry sensor system of inductive coupling by the power supply, this system estimates the capacitance of sensor with high precision in using RLSE, not the process of modulation and demodulation. In order to activate this system, inductive model is used and in case of time variant parameter, telemetry sensor system which has got high rate in accuracy is implemented by using the forgetting factor.

  • PDF

A Study on Cutting Force Measurement Using Cylindrical Capacitance-Type Spindle Displacement Sensor (주축 변위 센서를 이용한 절삭력 측정에 관한 연구)

  • 김일해;박만진;장동영;한동철
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2001.04a
    • /
    • pp.89-94
    • /
    • 2001
  • A cylindrical capacitance-type spindle displacement sensor was designed and tested in the hard turning as a way to develop a sensor that can estimate cutting forces without using a tool dynamometer. The displacement sensor was installed between the face of spindle cover and the chucking element, and measured pure radial motion of the spindle. Ceramic inserts and tool steel workpieceof 65 Rc were used during the hard turning tests. The signals from the sensor showed the same pattern of cutting force variations as those from the tool dynamometer. The research results showed that the developed sensor could be utilized as an effective and cheap on-line sensing device to estimate cutting forces.

  • PDF

A Design of Multi-Channel Capacitive Touch Sensing ASIC for SoC Applications in 0.18 ${\mu}m$ CMOS Process (0.18 ${\mu}m$ CMOS 공정을 이용한 SoC용 정전 용량형 멀티 채널 터치 센싱 ASIC의 설계)

  • Nam, Chul;Pu, Young-Gun;Park, Joon-Sung;Hong, Seong-Hwa;Hur, Jeong;Lee, Kang-Yoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.4
    • /
    • pp.26-33
    • /
    • 2010
  • This paper presents a multi-channel capacitive touch sensing unit for SoC applications. This unit includes a simple common processing unit and switch array to detect the touch sensing input by capacitive-time(C-T) conversion method. This touch sensor ASIC is designed based on the Capacitive-Time(C-T) conversion method to have advantages of small current and chip area, and the minimum resolution of the unit is 41 fF per count with the built-in sensing oscillator, LDO regulator and $I^2C$ for no additional external components. This unit is implemented in 0.18 um CMOS process with dual supply voltage of 1.8 V and 3.3 V. The total power consumption of the unit is 60 uA and the area is 0.26 $mm^2$.

Signal Analysis According to the Position of the ECG Sensor Electrode in Healthcare Backpack (헬스케어 가방의 ECG 센서 전극 위치에 따른 신호 분석)

  • Lee, Hyeon-Seok;Chung, Wan-Young
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.6
    • /
    • pp.402-408
    • /
    • 2014
  • Heart rate is one of the most important signal to monitor the health condition of the patient or exerciser. Various wearable devices have been developed for the continuous monitoring of ECG signal from human body during exercise. Among these, ECG chest belt has been widely used. However wearing chest belt with ECG sensor is uncomfortable in normal life due to the electrode contact between metal electrodes of ECG sensor and skin of the human body. So we develop the royal healthcare backpack that can measure ECG signal without skin contact by using capacitor-type ECG sensor. The position of the measurement point is critical to collect a clear ECG signal in the capacitive ECG measurement from backpack. Various tests were conducted to find the optimal ECG measurement position which has less noise and could get strong and clear ECG signal during exercise, walking, hiking, mountain climbing and cycling.

A Compact Low-Power Shunt Proximity Touch Sensor and Readout for Haptic Function

  • Lee, Yong-Min;Lee, Kye-Shin;Jeong, Taikyeong
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.16 no.3
    • /
    • pp.380-386
    • /
    • 2016
  • This paper presents a compact and low-power on-chip touch sensor and readout circuit using shunt proximity touch sensor and its design scheme. In the proposed touch sensor readout circuit, the touch panel condition depending on the proximity of the finger is directly converted into the corresponding voltage level without additional signal conditioning procedures. Furthermore, the additional circuitry including the comparator and the flip-flop does not consume any static current, which leads to a low-power design scheme. A new prototype touch sensor readout integrated circuit was fabricated using complementally metal oxide silicon (CMOS) $0.18{\mu}m$ technology with core area of $0.032mm^2$ and total current of $125{\mu}A$. Our measurement result shows that an actual 10.4 inches capacitive type touch screen panel (TSP) can detect the finger size from 0 to 1.52 mm, sharply.

A Circuit Design of Fingerprint Authentication Sensor (지문인식센서용 회로설계)

  • 남진문;정승민;이문기
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.4A
    • /
    • pp.466-471
    • /
    • 2004
  • This paper proposes an advanced circuit for fingerprint sensor signal processing. We increased the voltage between ridge and valley by modifying the parasitic capacitance eliminating circuit of sensor plate. The analog comparator was designed for comparing the sensor signal voltage with the reference signal voltage. 1-Pixel Fingerprint sensor circuit was designed and simulated, and the layout was performed.