• 제목/요약/키워드: cap bubble

검색결과 8건 처리시간 0.023초

Numerical Investigation of Bubble Characteristics in a Two-Dimensional Fluidized Bed

  • Kang, Kyung-Tae;Kook, Jeong-Jin;Park, Seung-Ho
    • 한국연소학회지
    • /
    • 제7권1호
    • /
    • pp.52-57
    • /
    • 2002
  • A numerical investigation using a commercial CFD program of the Inter-Phase Slip Algorithm has been carried out for detail characteristics of particle motions and bubble behaviors in a two dimensional fluidized bed. The bed simulated has been operated with three different distributor geometries, such as bubble cap, nozzle, and perforated plate types. Experiments using a slit-type two-dimensional fluidized bed and a cylinder-type fluidized bed have been performed in order to confirm the simulation model. In addition, the numerical results are compared with the wellknown correlation of bubble sizes and bubble rising velocities by Mori and Wen [1]. The simulation model that we applied is shown to be useful to understand the relation between bubble behaviors and distributor geometries.

  • PDF

Development of the Interfacial Area Concentration Measurement Method Using a Five Sensor Conductivity Probe

  • Euh, Dong-Jin;Yun, Byong-Jo;Song, Chul-Hwa;Kwon, Tae-Soon;Chung, Moon-Ki;Lee, Un-Chul
    • Nuclear Engineering and Technology
    • /
    • 제32권5호
    • /
    • pp.433-445
    • /
    • 2000
  • The interfacial area concentration (IAC) is one of the most important parameters in the two-fluid model for two-phase flow analysis. The IAC can be measured by a local conductivity probe method that uses the difference of conductivity between water and air/steam. The number of sensors in the conductivity probe may be differently chosen by considering the flow regime of two-phase flow. The four sensor conductivity probe method predicts the IAC without any assumptions of the bubble shape. The local IAC can be obtained by measuring the three dimensional velocity vector elements at the measuring point, and the directional cosines of the sensors. The five sensor conductivity probe method proposed in this study is based on the four sensor probe method. With the five sensor probe, the local IAC for a given referred measuring area of the probe can be predicted more exactly than the four sensor probe. In this paper, the mathematical approach of the five sensor probe method for measuring the IAC is described, and a numerical simulation is carried out for ideal cap bubbles of which the sizes and locations are determined by a random number generator.

  • PDF

Thickness-dependent magnetic domain structures of Co ultra-thin film investigated by scanning transmission X-ray microscopy

  • Yoon, Ji-Soo;Kim, Namdong;Moon, Kyoung-Woong;Lee, Joo In;Kim, Jae-Sung;Shin, Hyun-Joon;Kim, Wondong
    • Current Applied Physics
    • /
    • 제18권11호
    • /
    • pp.1185-1189
    • /
    • 2018
  • Thickness-dependent magnetic domain structure of ultrathin Co wedge films (0.3 nm-1.0 nm) sandwiched by Pt layers was investigated by scanning transmission x-ray microscopy (STXM) employing X-ray magnetic circular dichroism (XMCD), utilizing elliptically polarized soft x-rays and electromagnetic fields, with a spatial resolution of 50 nm. The magnetic domain images measured at the Co $L_3$ edge showed the evolution of the magnetic domain structures from maze-like form to the bubble-like form as the perpendicular magnetic field was applied. The asymmetric domain expansion of a 500 nm-scale bubble domain was also measured when the in-plane and perpendicular external magnetic field were applied simultaneously.

저온환경에서의 양생시트 변화에 따른 콘크리트의 온도이력 특성 (Temperature History of the Concrete Corresponding to Various Curing Sheets in the Low Temperature)

  • 백대현;홍석민;한민철;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 추계 학술발표회 제20권2호
    • /
    • pp.781-784
    • /
    • 2008
  • 본 연구에서는 저온 환경에서 단열양생시트 변화에 따른 콘크리트의 온도이력 및 강도특성을 검토하였다. 실험결과 -5$^{\circ}$C에서 노출과 air cap포장지의 경우 초기 24시간 이내로 콘크리트의 온도가 영하의 온도로 저하되어 초기동해가 발생되었다. 반면, 비닐+부직포의 경우 초기 24시간이내의 최저온도가 약 3$^{\circ}$C로 영상의 온도를 유지하였고 이중버블시트의 경우 약 7$^{\circ}$C로 나타나 양호한 단열 보온성능을 나타내었다. 코어압축강도를 측정한 결과 비닐+부직포와 이중버블시트로 양생한 시험체의 압축강도가 양생초기의 우수한 단열효과로 인해 다른 시험체의 압축강도보다 높게 나타났다.

  • PDF

Electric current control of creation and annihilation of sub-100 nm magnetic bubbles examined by full-field transmission soft X-ray microscopy

  • Je, Soong-Geun;Jung, Min-Seung;Im, Mi-Young;Hong, Jung-Il
    • Current Applied Physics
    • /
    • 제18권11호
    • /
    • pp.1201-1204
    • /
    • 2018
  • The effect of electric current pulses on a sub-100 nm magnetic bubble state in a symmetric Pt/Co multilayer was directly observed using a full-field transmission soft X-ray microscope (MTXM). Field-induced evolution of the magnetic stripe domains into isolated bubbles with their sizes down to 100 nm was imaged under varying external magnetic fields. Electric current pulses were then applied to the created magnetic bubbles, and it was observed that the bubbles could be either created or annihilated by the current pulse depending on the strength of applied magnetic field. The results suggest that the Joule heating plays a critical role in the formation and/or elimination of the bubbles and skyrmions. Finally, the schematic phase diagram for the creation and annihilation of bubbles is presented, suggesting an optimized scheme with the combination of magnetic field and electric current necessary to utilize skyrmions in the practical devices.

직접접촉식 LNG기화기 응용을 위한 칼럼 열교환기 기포특성에 관한 연구 (The Characteristics of Bubbles in a Column Heat Exchanger for the Application of Direct Contact LNG Evaporator)

  • 김성종;한승탁;김종보
    • 설비공학논문집
    • /
    • 제3권2호
    • /
    • pp.142-151
    • /
    • 1991
  • In the present investigation, it has been proposed to utilize a direct contact heat exchanger as an evaporator to solve the difficulties such as scaling, corrosion and law thermal efficiencies, associated with the conventional evaporator. Liquified nitrozen was utilized as a working fluid to investigate basic natures of bubble dynamics in the evaporator, and spray nozzles were adopted to inject liquified nitrozen into the spray column with varying flow rates of dispersed phase fluids. Experimentations were carried out in the range of $6.54{\times}10^{-4}kg/s$ - 0.030 kg/s for dispersed phase flow rates with one, three and five nozzle holes. Observing the bubble dynamics for the evaporator the feasibility of utilizing a direct contact heat exchanger as a LNG evaporator has been evaluated. The results show that no eruption phenomena was observed in the present investigation with $LN_2$ and the interface between $N_2$ bubbles and water was fully turbulent. It is believed that the high injection velocity of $LN_2$ through the spray nozzles provide good mixing effects for both heat and mass transfers between water and $N_2$ bubbles. Ice was formed on the surface of the spray nozzle for higher $LN_2$ flow rates. However, even in this case, it is observed that the ice was detached as soon as it was formed. Under the present experimental conditions, the shapes of $LN_2$ bubbles were in the spherical-cap region according to the Clift, Grace and Weber Graphs. The height of foam region caused by the breakup of larger bubbles keeps increasing with high injection velocities until it reaches it's maximum height.

  • PDF

수술적 처치가 필요했던 식도이물에 관한 임상적 고찰 (A Surgical Treatment of the Esophageal Foreign Body (10 cases report))

  • 황의두;황경환
    • Journal of Chest Surgery
    • /
    • 제30권11호
    • /
    • pp.1117-1120
    • /
    • 1997
  • 충남대학교병원에서 1980년7월부터 1995년 8월까지 경험한 식도이물 10례를 수술 치료하였다. 나이는 25 세에서 71세로, 평균 나이는 45.3세였고 남녀의 비는 6:4였다 가장 흔한 증상은 연하곤란, 발열, 이물감, 경부 동통이였다. 이물질은 생선뼈 3례였고, 거품 약포장지가 2례였고, 맥주병 마개,욕조 물마개, 깨진 사발 조각, 닭고기, 콩이 각각 1례였다. 진단은 수용성 식도 조영제와 식도 내시경을 이용하였다. 10례중 2례에서는 과거에 가성소다 섭취로 인해 식도 협착이 있었다. 1례에서는 정신과적 문제가 있었다. 식도이물은 모두 수술적 처치로 제거하였다 5례에서는 경부식도절게술을 시행하였고 1례는 우측 개흉술 을, 1례는 개복하여 위를 통해 위관을 역류성으로 통과 제거하였으며, 2례는 경부농양이 있어 절개후 배농하 였다. 3례는 수술 후 누출이 있었으나 수술치료없이 보존적 요법으로 호전되었으며,1례는 일시적인 애성이 있 었다. 1례는 외상성 기흉이 발생하여 폐쇄적 홉관 삽관술로 치료하였다. 수술 사망자는 없었다.

  • PDF