• Title/Summary/Keyword: cancellous and cortical bone

Search Result 123, Processing Time 0.026 seconds

Stabilization of Recurrent Medial Shoulder Luxation by Use of Three Bone Anchors in a Dog (재발성 내측 어깨 탈구를 보이는 개에서 본 앵커를 이용한 외과적 치료 증례)

  • Yoon, Hun-Young;Roh, Mi-Young;Jeong, Soon-Wuk
    • Journal of Veterinary Clinics
    • /
    • v.30 no.1
    • /
    • pp.45-48
    • /
    • 2013
  • A 12-year-old male poodle weighing 2.0 kg presented for evaluation of right thoracic limb lameness. The owner reported that the dog showed recurrent bilateral shoulder joint luxation after a car accident for a year. Recently, the left shoulder joint appeared well maintained, but right shoulder joint luxation was exacerbated. On physical examination, the dog showed non-weight bearing lameness on the right thoracic limb. Craniocaudal radiographic views revealed medial displacement of the right humerus. Mediolateral radiographic views revealed overlap of the glenoid cavity and humeral head. Muscle atrophy of the right thoracic limb, reduced biceps brachii muscle tendon tone, a tear of the medial glenohumeral ligament, and a rupture of the subscapularis tendon were identified intraoperatively. Transposition of the biceps muscle tendon was performed. However, at 7 days, there was evidence of right shoulder reluxation on radiographs. The second surgery was performed with two $2mm{\times}6mm$ cortical bone anchors and a $4mm{\times}6mm$ cancellous bone anchor placed in the cortical bone of the distal scapula and the cancellous bone of the proximal humerus respectively. Two scapular bone anchors were then connected with a humeral bone anchor using heavy nylon suture to minimize shoulder abduction range of motion. On radiographs right after surgery and 6 weeks after surgery, the affected limb revealed no evidence of medial shoulder luxation. At 6 months, no evidence of lameness was noted on the right thoracic limb.

Extraction of Crude-BMP from Bovine Cortical Bone for Bone Grafts (골이식물로서의 소뼈 치밀골에서 Crude-BMP의 추출)

  • Choi Sung-jin;Park Chul;Heo Soo-young;Lee Jong-il;Jeong In-seong;Kim Nam-soo;Choi In-hyuk
    • Journal of Veterinary Clinics
    • /
    • v.22 no.4
    • /
    • pp.377-381
    • /
    • 2005
  • We tried to extract bone morphogenetic protein (BMP) from the freeze-dried bovine cortical bone (FBCB) for bone graft, which were defatted with chloroform-methanol for 20 days, freeze-dried at $-80^{\circ}C$ for 7 days and sterilized by ethylene oxide gas. Two kg of FBCB were pulverized in a wheel mill to $0.5-2.0mm^3$ cubic in size. The bone particles were demineralized in 0.6N HCI for 10 days at chloroform-methanol$4^{\circ}C$ and defatted with chloroform-methanol for 6 hours at room temperature, which was going to be defatting and demineralized cortical bone (DDM). For extracting BMP, DDM was agitated continuously through 72 hours with magnetic stirrer at $4^{\circ}C$ into 12 times of volume of 6 M guanidine hydrochloride (Gdn-HCl) solution containing proteinase inhibitors to protect BMP such as 2mM N-ethylaleimide, 1mM iodoacetic acid, 1mM phenylmethylsulfonyl fluoride and a sterilizer, 1mM sodium azide. The extraction procedure was repeated for three times. All extracted solution was centrifuged at 10,000 rpm for 30 min and then, the supernatant was dialyzed with 12 times of volume of deionized water at $4^{\circ}C$ for 24-72 hours, which cut off below 6,000-8,000 molecular weight. The dialyzed specimen contained crude-BMP was centrifuged, freeze-dried, and weighted. Through these processing, we could obtained $84.9\%$ as FBCB, $17.8\%$ as DDM and $0.71\%$ as crude-BMP from the wet cortical bone without cancellous bone, marrow and muscles. The crude-BMP were obtained $68.3\%$ from the first extraction, $29.6\%$ from secondary and $2.1\%$ from tertiary, respectively. It was suggested that high yield of crude-BMP migth be explained by three-time repetition of the extraction processing for crude-BMP with Gdn-Hcl sol.

Finite Element Analysis on the Supporting Bone according to the Connection Condition of Implant Prosthesis (임플란트 보철물의 연결 여부에 따른 유한요소응력분석)

  • Kang, Jae-Seok;Jeung, Jei-Ok;Lee, Seung-Hoon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.1
    • /
    • pp.31-42
    • /
    • 2007
  • The purpose of this study was to compare the stress distribution according to the splinting condition and non-splinting conditions on the finite element models of the two units implant prostheses. The finite element model was designed with the parallel placement of two fixtures ($4.0mm{\times}11.5mm$) on the mandibular 1st and 2nd molars. A cemented abutment and gold screw were used for superstructures. A FEA models assumed a state of optimal osseointegration, as the bone quality, inner cancellous bone and outer 2 mm compact bone was designed. This concluded that the cortical and trabecular bone were assumed to be perfectly bonded to the implant. Splinting condition had 2 mm contact surface and non-splinting condition had $8{\mu}m$ gap between two implant prosthesis. Two group (Splinting and non-splinting) were loaded with 200 N magnitude in vertical axis direction and were divided with subdivision group. Subdivision group was composed of three loading point; Center of central fossa, the 2 mm and 4 mm buccal offset point from the central fossa. Von Mises stress value were recorded and compared in the fixture-bone interface and bucco-lingual sections. The results were as follows; 1. In the vertical loading condition of central fossa, splinting condition had shown a different von Mises stress pattern compared to the non-splinting condition, while the maximum von Mises stress was similar. 2. Stresses around abutment screw were more concentrated in the splinting condition than the non-splinting condition. As the distance from central fossa increased, the stress concentration increased around abutment screw. 3. The magnitude of the stress in the cortical bone, fixture, abutment and gold screw were greater with the 4 mm buccal offset loading of the vertical axis than with the central loading.

Influence of diameter, length, and platform shape of implant fixture on the stress distribution in and around the screw type implant (나사형 임플란트 고정체의 길이, 직경, 플랫폼 형태에 따른 임플란트와 주위조직의 응력분포)

  • Kang, Ji-Eun;Chung, Hyun-Ju;Ku, Chul-Whoi;Yang, Hong-So
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.18 no.4
    • /
    • pp.277-288
    • /
    • 2002
  • Seven finite element models were constructed in mandible having single screw-type implant fixture connected to the premolar superstructure, in order to evaluate how the length, diameter and platform shape of a screw-type fixture influence the stress in the supporting tissue around fixtures. Each finite element model was varied in terms of length, diameter, and platform shape of the fixture. In each model, 250N of vertical load was placed on the central pit of an occlusal plane and 250N of oblique load placed on the buccal cusp. The stress distribution in the supporting tissue and the other components was analysed using 2-dimensional finite element analysis and the maximum von Mises stress in each reference area was compared. Under lateral loading, the stress was larger at the abutment/fixture interface, and in the crestal bone, compared to the stress pattern under vertical loading. The amount of stress at the superstructure was similar regardless of the length, diameter and platform shape of a fixture. Around the longer fixture, the stress was decreased at the bone crest and subjacent cancellous bone and increased in the cancellous bone area apical to the fixture. Around the wider fixture, the stress was decreased at the abutment/fixture interface, and the bone crest and increased in the cancellous bone area apical to the fixture. Around the fixture having wider platform, less stress was produced at the abutment/fixture interface and the upper part of the cortical bone, compared to the fixture having standard platform. In conclusion, the stress distribution of the supporting tissue was affected by length, diameter, and platform shape of a fixture, and the fixture which was larger in diameter and length could reduce the stress in the supporting tissues at the bone-fixture interface and bone crest area.

FINITE ELEMENT APPROACH TO INVESTIGATE THE INFLUENCE OF THE DESIGN CONFIGURATION OF THE ITI SOLID IMPLANT ON THE BONE STRESSES DURING THE OSSEOINTEGRATION PROCESS (유한요소해석을 통한 ITI Solid screw 임플랜트의 형상 특성이 골유착 단계에서 응력에 미치는 영향에 대한 연구)

  • Cha Sang-Bum;Lee Kyu-Bok;Jo Kwang-Hun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.2
    • /
    • pp.217-228
    • /
    • 2006
  • Statement of problem: Standard type of ITI solid implant model in the 6.2mm thick jaw bone was axisymmetrically modelled for finite element stress analyses. Purpose: Primary objective was to investigate the influences or the characteristic design configuration of the ITI solid implant model on the bone stress with the course of osseointegration process at the bone/implant interfaces. To simulate the characteristics of the osseointegration process, five different stages of the bone/implant interface model were implemented. As load conditions, vertical load of 50N was taken into consideration. Bone at the cervical region of implant was the areas of concern where the higher level of stress were likely to take place. Results: The results indicated that rather slightly different stress level could be obtained as a function of the osseointegration conditions. Conclusion: Under vertical load, the lower level of stress was observed at the cervical cortical bone in the initial and final stages of osseointegration. Relatively higher stress level, however, was observed during the transitional stages where the osseointegration at the cancellous bone interface were yet to fully develop.

INFLUENCE OF IMPLANT FIXTURE DESIGN ON IMPLANT PRIMARY STABILITY (임플랜트 고정체의 형태가 임플랜트 초기안정성에 미치는 영향)

  • Oh, Gap-Yong;Park, Sung-Hwa;Kim, Seok-Gyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.1
    • /
    • pp.98-106
    • /
    • 2007
  • Statement of problem: Current tendencies of the implant macrodesign are tapered shapes for improved primary stability, but there are lack of studies regarding the relationship between the implant macrodesign and primary stability. Purpose: The purpose is to investigate the effect of implant macrodesign on the implant primary stability by way of resonance frequency analysis in the bovine rib bones with different kinds of quality. Material and method: Fifty implants of 6 different kinds from two Korean implant systems were used for the test. Bovine rib bones were cut into one hundred pieces with the length of 5 cm. Among them forty pieces of rib bones with similar qualities were again selected. For the experimental group 1, the thickness of cortical part was measured and 20 pieces of rib bones with the mean thickness of 1.0mm were selected for implant placement. For the experimental group 2, the cortical parts of the remaining 20 pieces of rib bones were totally removed and then implants were placed on the pure cancellous bone according to the surgical manual. After placement of all implants, the implant stability quotient(ISQ) was measured by three times, and its statistical analysis was done. Results: There are statistically significant differences in ISQ values among 4 different kinds of Avana system implants in the experimental group 2. For the experimental group 1, Avana system implants showed significantly different ISQ values, but when differences in the thickness of cortical parts were statistically considered, did not show any significant differences in ISQ values. Among Oneplant system implants, there are no significant differences in ISQ values for the experimental group 2 as well as for the experimental group 1. Conclusion: Within the limits of this study, bone quality and implant design have some influences on the primary stability of implants. Especially in the bone of poor quality, tapered shape of implants are more favorable for the primary stability of implants.

Effect of Stem Design on Contact Pressure and Stress Distribution of End-of-stem in Revision TKR (슬관절 재전치환술용 경골 삽입물 형상이 주대 말단부의 접촉압력과 응력 분포에 미치는 영향)

  • Kim, Yoon-Hyuk;Kwon, Oh-Soo;Park, Si-Mon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.11 s.188
    • /
    • pp.126-134
    • /
    • 2006
  • In this study, the effect of stem-end design on contact pressure and stress distribution in revision TKR was investigated using finite element method. The finite element model of tibia, including the cortical bone, the cancellous bone and canal, was developed based on CT images. The implant models with various stem lengths, diameters, friction coefficients, and press-fit effects were considered. The results showed that the longer stem length, the stronger press-fit, the bigger stem diameter, and the higher friction coefficient increased both peak contact pressure and Von-Mises stress distributions. The results supported the clinical hypothesis that peak contact pressure and stress are related to the stem end pain. The results of this study will be useful to design the stem and reduce the end-of-stem pain in revision TKR.

Analysis of Partial Denture through Topology Optimization Design (위상최적설계를 통한 가공의치의 해석)

  • Lee, Jeong-Ick;Koh, Byung-Kab
    • Korean Journal of Computational Design and Engineering
    • /
    • v.11 no.5
    • /
    • pp.351-358
    • /
    • 2006
  • Recently, the development of new structural model in fixed partial denture system is required to be started from the conceptual design with low cost, high performance and quality. In this point, a FEM based design of partial denture is used to investigate stress distribution on the durable shape. In this paper, the structural performances of partial dentures were analyzed under three biting forces. The periodontal embedding model is introduced on behalf of the detailed supporting tissue, which is composed of dentin, cortical bone, cancellous bone and periodontal ligament. Using topology optimization, the optimal reinforcement layout of connector was obtained and the detail shape in the fixed partial denture was designed.

Analysis of Bone-Remodeling Process Using Quasi-molecular Dynamics (요추 추체의 골 -재형성에 대한 준분자 동력학적 접근 방법)

  • 김영은;최훈희
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.5
    • /
    • pp.447-451
    • /
    • 2003
  • A new method for analyzing the bone-remodeling process using quasi-molecular dynamics was proposed in this study. The effect of pressure due to bone marrow, which could not be considered in previous methods, was also considered in this method. Bone-remodeling response of the 2D vertebral body of lumbar spine to a uniaxial compressive displacement of 1.8564mm. corresponding to approximately 2kN of compressive load, was studied. Converged shape change of the cortical shell and rearrangement of cancellous bone structure matched well with a normal shape of the vertebral body. The calculated responses in the spinal elements also shows closed results compared with experimental results.

The Effects of Type of Rapid Palatal Expansion Appliance on the Circummaxillary Sutures : A 3D FEA study (급속 구개 확장 장치 종류가 상악골 주변 봉합에 미치는 영향에 대한 유한요소해석)

  • Kim, Yu-Wan;Moon, Yoon-Sik;Sung, Sang-Jin
    • Korean Journal of Cleft Lip And Palate
    • /
    • v.15 no.2
    • /
    • pp.51-60
    • /
    • 2012
  • Craniofacial sutures absorb the stress transferred to skull. It was reported the cells of craniofacial sutures respond to exogenetic factors to be involved in growth control mechanism. In this study, we constructed a finite element model composed of cortical bone, cancellous bone, suture, PDL, and teeth by using CT images of a growing patient, simulating maxillary expansion to evaluate the effects of the thickness of sutures and type of maxillary expansion appliance on stress distribution in circummaxillary sutures.

  • PDF