• 제목/요약/키워드: camera vibration

검색결과 239건 처리시간 0.038초

카메라 영상을 이용한 진동 변위 측정 시 카메라 흔들림 보정 방법 (Correction of Error due to Camera Shaking when Vibration Measurement by Using Camera Image)

  • 전형섭;손기성;한순우;박종원
    • 한국소음진동공학회논문집
    • /
    • 제24권10호
    • /
    • pp.817-824
    • /
    • 2014
  • Accelerometer and laser vibrometers are widely used to measure vibration of structures like a building or piping. Recently, the research measuring vibration by using camera image is introduced. However, this method has a disadvantage. If camera moves by the vibration cannot measure the vibration displacement of structure. We proposed the enhanced technique for measuring vibration using camera. This paper took the experiment for correction of error due to camera shaking. We verified through an experiment. And the accuracy of the method measuring the vibration displacement by using the camera images was analyzed.

카메라를 이용한 진동 측정 시 주요인자 분석 (Parameter Studies for Measuring Vibration by Using Camera)

  • 전형섭;최영철;박진호;박종원
    • 한국소음진동공학회논문집
    • /
    • 제20권11호
    • /
    • pp.1033-1037
    • /
    • 2010
  • Accelerometer and laser vibrometers are widely used to measure vibration of structures like a building or piping. Recently, the research measuring vibration by using camera image is introduced. This method can measure multi-points simultaneously. Also, it is possible to measure in the long distance. When we measure the vibration using a camera, the parameter analysis is needed. Therefore, this paper took the experiment for the camera lens selection. An error by the camera images characteristic was theoretically analyzed and we verified through an experiment. And the accuracy of the method measuring the vibration displacement by using the camera images was analyzed.

영상 신호에서 커브 피팅을 이용한 구조물 진동 측정 (Measuring Structural Vibration from Video Signal Using Curve Fitting)

  • 전형섭;최영철;박종원
    • 한국소음진동공학회논문집
    • /
    • 제19권9호
    • /
    • pp.943-949
    • /
    • 2009
  • Many studies for measuring vibration using image signal are suggested. These methods can measure vibration of multi-points simultaneously. However, it has the disadvantage that is very sensitive to an environment. If the measured environment is not good, image signals can be measured including much background noise. So, it is difficult to obtain accurate vibration from the measured image signals. Another problem is that camera imaging has a resolution limit. Because the resolution of the camera image is relatively much lower than that of a data acquisition system, accurate measuring vibration cannot be performed. In this paper, we proposed the enhanced technique for measuring vibration using camera signal. The key word of this paper is a curve fitting. The curve fitting can exactly detect the measurement line of interested object. So, we can measure the vibration in noisy environment. Also, it can overcome the resolution limit.

카메라 영상을 이용한 진동변위 측정 (A Technique for Measuring Vibration Displacement Using Camera Image)

  • 손기성;전형섭;박진호;박종원
    • 한국소음진동공학회논문집
    • /
    • 제23권9호
    • /
    • pp.789-796
    • /
    • 2013
  • Vibration measurements using image processing have been studied by many researchers as it can remotely measure vibration displacements at multiple points simultaneously. It is difficult, however, to obtain accurate displacement from the measured image signals because the resolution of image data is dependent on camera performance and normally lower than that of vibration transducer directly measured. This paper suggests the enhanced technique for vibration displacement measurement by applying the expected value of edge probability distribution to the varying pixel points in the image. The method can both increase the resolution limit of camera image and decrease the measurement errors. The working performance of the proposed technique is verified applying to the vibration measurement of a rotating machine.

무인항공기 임무장비용 압전 마운트 시스템의 진동 제어 성능 평가 (Evaluation of Vibration Control Performance of Camera Mount System for UAV)

  • 오종석;손정우;최승복
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 추계학술대회 논문집
    • /
    • pp.407-412
    • /
    • 2009
  • In the present work, vibration control performance of active camera mount system for unmanned aero vehicle (UAV) is evaluated. An active mount featuring inertia type of piezostack actuator is designed and manufactured. Then, vibration control performances are experimentally evaluated. A camera mount system with four active mounts is constructed and mechanical model is established. The governing equation for the camera mount system is obtained and control model is constructed in state space model. Sliding mode controller which has inherent robustness to external disturbance is designed and implemented to the system. Vibration control performances are evaluated at each mount and center of gravity point. Effective vibration performances are obtained and presented in time and frequency domains.

  • PDF

카메라 영상을 이용한 회전축 진동 측정 및 진원도 평가 방법 (A Technique for Vibration Measurement and Roundness Assessment of Rotating-axis using Camera Image)

  • 손기성;전형섭;박진호;박종원
    • 한국소음진동공학회논문집
    • /
    • 제24권2호
    • /
    • pp.131-138
    • /
    • 2014
  • Vibration measurement of rotating shafts by installing sensors such as accelerometers or displacement sensors is costly and dangerous in some cases. As an alternative method, vibration measurement using camera images has been researched because sensor installation is not needed and displacement of a rotating shaft can be directly evaluated. This paper also suggests the enhanced technique applicable to the measurement of vibration of a large-scale rotating shaft. The concurrent methods based on camera images use marks, which are hardly applicable to rotating shafts. The proposed method measures vibration without any marks by evaluating shape errors. The working principle of the method is described and verified by a series of experiments.

무인항공기 임무장비용 압전 마운트 시스템의 진동 제어 성능 평가 (Evaluation of Vibration Control Performance of Camera Mount System for UAV)

  • 오종석;손정우;최승복
    • 한국소음진동공학회논문집
    • /
    • 제19권12호
    • /
    • pp.1315-1321
    • /
    • 2009
  • In the present work, vibration control performance of active camera mount system for unmanned aero vehicle(UAV) is evaluated. An active mount featuring inertia type of piezostack actuator is designed and manufactured. Then, vibration control performances are experimentally evaluated. A camera mount system with four active mounts is constructed and mechanical model is established. The governing equation for the camera mount system is obtained and control model is constructed in state space model. Sliding mode controller which has inherent robustness to external disturbance is designed and implemented to the system. Vibration control performances are evaluated at each mount and center of gravity point. Effective vibration performances are obtained and presented in time and frequency domains.

방진을 고려한 항공 정찰용 카메라 모듈부의 진동특성에 관한 연구 (A Study on the Vibration Characteristics of Camera Module for Aerial Reconnaissance Considering Vibration Isolator)

  • 이상은;이태원
    • 한국정밀공학회지
    • /
    • 제29권5호
    • /
    • pp.545-553
    • /
    • 2012
  • A Gimbal structure system in observation reconnaissance aircraft is made up of camera module and stabilization drive device supporting camera module. During flight for image recording, the aircraft undergoes serious accelerations with wide frequencies due to several factors. Though base excitation of stabilization drive device induces vibration of camera module, it must get the stable and clean images. To achieve this aim, acceleration of camera module must be reduced. Hence, vibration isolators were installed to stabilization drive device. Considering isolators and bearings in the stabilization drive device, vibration characteristics of gimbal structure system were analyzed by finite element method. For three translational direction, acceleration transmissibility of camera module was calculated by harmonic responses analysis in the frequency range of 5 ~ 500 Hz. In addition to, sine-sweep experiment were performed to prove correctness of present analysis.

EO/IR 카메라에 적용된 볼 베어링의 3축 스프링 요소 모델 및 EO/IR 카메라의 구조 응답해석 (Three-axis Spring Element Modeling of Ball Bearing Applied to EO/IR Camera and Structural Response Analysis of EO/IR Camera)

  • 조희근;이주훈;이준호
    • 한국항공우주학회지
    • /
    • 제39권12호
    • /
    • pp.1160-1165
    • /
    • 2011
  • 본 연구는 무인항공기 및 헬리콥터 등에 장착되어 운용되는 고정밀 관측 다축 구동 EO/IR 카메라의 진동해석에 관한 것이며, 카메라에 적용된 볼 베어링을 모델링 하는데 있어서 3축 스프링요소를 적용하는 방법을 제시하였고, 이것에 의한 유한요소모델의 진동 응답 결과를 얻었다. 볼 베어링을 3축 스프링 요소로 모델링한 진동해석결과는 시험결과와 비교 되었으며, 잘 일치함을 알 수 있었다. 또한, 랜덤진동 시간이력해석을 통하여 다축 구동 EO/IR 카메라의 진동 응답 특성을 해석하고 분석하였다. 이의 연구결과는 우주용 카메라들에 사용되는 볼 베어링의 유한요소모델링 기법에 응용될 수 있다.

디지털 카메라를 이용한 구조물의 동특성 추출 (Modal Parameter Extraction Using a Digital Camera)

  • 김병화
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 추계학술대회논문집
    • /
    • pp.61-68
    • /
    • 2008
  • A set of modal parameters of a stay-cable have been extracted from a moving picture captured by a digital camera supported by shaking hands. It is hard to identify the center of targets attached on the cable surface from the blurred cable motion image, because of the high speed motion of cable, low sampling frequency of camera, and the shaking effect of camera. This study proposes a multi-template matching algorithm to resolve such difficulties. In addition, a sensitivity-based system identification algorithm is introduced to extract the natural frequencies and damping ratios from the ambient cable vibration data. Three sets of vibration tests are conducted to examine the validity of the proposed algorithms. The results show that the proposed technique is pretty feasible for extracting modal parameters from the severely shaking motion pictures.

  • PDF