• 제목/요약/키워드: camera exposure

검색결과 166건 처리시간 0.023초

Optical Design of a Snapshot Nonmydriatic Fundus-imaging Spectrometer Based on the Eye Model

  • Zhao, Xuehui;Chang, Jun;Zhang, Wenchao;Wang, Dajiang;Chen, Weilin;Cao, Jiajing
    • Current Optics and Photonics
    • /
    • 제6권2호
    • /
    • pp.151-160
    • /
    • 2022
  • Fundus images can reflect ocular diseases and systemic diseases such as glaucoma, diabetes mellitus, and hypertension. Thus, research on fundus-detection equipment is of great importance. The fundus camera has been widely used as a kind of noninvasive detection equipment. Most existing devices can only obtain two-dimensional (2D) retinal-image information, yet the fundus of the human eye also has spectral characteristics. The fundus has many pigments, and their different distributions in the eye lead to dissimilar tissue penetration for light waves, which can reflect the corresponding fundus structure. To obtain more abundant information and improve the detection level of equipment, a snapshot nonmydriatic fundus imaging spectral system, including fundus-imaging spectrometer and illumination system, is studied in this paper. The system uses a microlens array to realize snapshot technology; information can be obtained from only a single exposure. The system does not need to dilate the pupil. Hence, the operation is simple, which reduces its influence on the detected object. The system works in the visible and near-infrared bands (550-800 nm), with a volume less than 400 mm × 120 mm × 75 mm and a spectral resolution better than 6 nm.

임상용 X-선관을 이용한 X-ray PIV시스템의 개발 (Development of X-ray PIV System Using a Medical X-ray Tube)

  • 임대현;김국배;김도일;이형구;이상준
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.403-406
    • /
    • 2006
  • A new medical X-ray PIV technique was developed using a conventional medical X-ray tube. To acquire images of micro-scale particles, the X-ray PIV system consists of an x-ray CCD camera with high spatial resolution, and a X-ray tube with small a focal spot. A new X-ray exposure control device was developed using a rotating disc shutter to make double pulses which are essential for PIV application. Synchronization methodology was also developed to apply the PIV technique to a conventional medical X-ray tube. In order to check the performance and usefulness of the developed X-ray PIV technique, it was applied to a glycerin flow in an opaque silicon tube. Tungsten particles which have high X-ray absorption coefficient were used as tracer particles. Through this preliminary test, the spatial resolution was found to be higher than ultrafast MRI techniques, and the temporal resolution was higher than conventional X-ray PIV techniques. By improving its performance further and developing more suitable tracers, this medical X-ray PIV technique will have strong potential in the fields of medical imaging or nondestructive inspection as well as diagnosis of practical thermo-fluid flows.

  • PDF

영상처리에 의한 위상잠금 열화상기법의 최적화 연구 (Optimization of Lock-in Thermography Technique using Phase Image Processing)

  • 조용진;한송이
    • 한국해양공학회지
    • /
    • 제26권5호
    • /
    • pp.25-30
    • /
    • 2012
  • This study examined the use of LIT (lock-in infrared thermography) to detect defects in the welded parts of ships and offshore structures. A quantitative analysis was used with the filtering and texture measurement of image processing techniques to find the optimized experimental condition. We verified the reliability of our methods by applying image processing techniques in order to normalize the evaluations of comparative images that showed a phase difference. In addition, it was found that a low to mid-range intensity of light exposure on the surface showed good results, whereas high exposure did not provide significant results. A lock-in frequency of around 0.1 Hz was satisfactory regardless of the intensity of the light source. In addition, making the integration time of the thermography camera inversely proportional to the intensity of the exposed light source during the experiment provided good results.

Comparison of Gold Biosensor Combined with Light Microscope Imaging System with ELISA for Detecting Salmonella in Chicken after Exposure to Simulated Chilling Condition

  • Mi-Kyung Park
    • Journal of Microbiology and Biotechnology
    • /
    • 제33권2호
    • /
    • pp.228-234
    • /
    • 2023
  • In this study, the performance of a gold biosensor combined with light microscope imaging system (GB-LMIS) was comparatively evaluated against enzyme-linked immunosorbent assay (ELISA) for detecting Salmonella under simulated chilling condition. The optimum concentration of antiSalmonella polyclonal antibodies (pAbs) was determined to be 12.5 and 100 ㎍/ml for ELISA and GBLMIS, respectively. GB-LMIS exhibited a sufficient and competitive specificity toward three tested Salmonella among only. To mimic a real-world situation, chicken was inoculated with Salmonella cocktail and stored under chilling condition for 48 h. The overall growth of Salmonella under chilling condition was significantly lower than that under non-exposure to the chilling condition (p < 0.05). No significant differences in bacterial growth were observed between brain heart infusion and brilliant green broth during the enrichment period (p > 0.05). Finally, both GB-LMIS and ELISA were employed to detect Salmonella at every 2-h interval. GB-LMIS detected Salmonella with a competitive specificity by the direct observation of bacteria on the sensor using a charge-coupled device camera within a detection time of ~2.5 h. GB-LMIS is a feasible, novel, and rapid method for detecting Salmonella in poultry facilities.

휴대용 단말 기반 의료용 무선 방사선 모니터링 시스템 개발 (Development of a Portable Device Based Wireless Medical Radiation Monitoring System)

  • 박혜민;홍현승;김정호;주관식
    • Journal of Radiation Protection and Research
    • /
    • 제39권3호
    • /
    • pp.150-158
    • /
    • 2014
  • 각 의료기관 내 방사선 관련 종사자나 방사선 치료환자들은 진단 및 치료 시 필연적으로 의료상 피폭을 수반하게 된다. 국제방사선방호위원회(ICRP) 권고나 국제원자력기구(IAEA)의 기준에 따라 기준선량 제약치를 적용 및 권고 받고 있지만 1차 피폭대상자인 종사자나 환자들의 피폭최적관리를 위해서는 잠재적인 피폭대상자들에게 기존의 피폭관리 시스템보다 직접적이고 가용성이 높은 측정 및 분석 방법이 필요하다. 따라서 본 연구에서는 기존에 구비된 휴대용 단말과 연동하여 원거리에서 실시간으로 방사선 모니터링이 가능한 시스템을 개발하였다. 모니터링 시스템은 검출부, 영상부, 통신부 세 부분으로 구성되었다. 검출부는 시스템의 소형화를 위해 실리콘 광증배소자(silicon photomultiplier) 기반 섬광검출기를 설계하였으며, 영상부는 무선 CCD (charge-coupled device)카메라 모듈을 사용하여 검출부와 함께 Bluetooth 통신모듈을 통해 휴대용 단말로 측정된 방사선 정보와 영상이 전송된다. 제작된 시스템은 성능 평가를 위해 진단용 X-ray 발생장치와 $^{137}Cs$, $^{22}Na$, $^{60}Co$, $^{204}Tl$, $^{90}Sr$ 선원을 사용하였다. 측정결과를 통해 개발된 시스템은 gamma, beta, X-ray에 대해서 검출 반응성을 확인하였고, 방사선 세기에 따른 응답 선형성과 MCNPX 전산코드를 이용한 측정 거리에 따른 시스템의 검출 정확도 평가 시 3% 내외의 오차범위를 확인하였다. 본 연구의 결과는 방사선 검출 시스템 구성의 비용절감 효과와 개인피폭정도관리에 기여할 것으로 기대한다.

소프트 프루핑에서 최적의 Profiling을 이용한 컬러 관리에 관한 연구 (A Study on Color Management using Optimum Profiling in Soft Proofing)

  • 차재영;조가람;구철회
    • 한국인쇄학회지
    • /
    • 제27권1호
    • /
    • pp.1-14
    • /
    • 2009
  • The color reproduction of digital still camera does not, in general, match those of the final output device. Because color gamut of these devices is different, it is therefore necessary to take account of a way to match. The way uses the optimized profile to output device an image. This paper proposed a way to create the input profile of digital still camera for standardization soft proofing process. The results of proposed way showed that for input profiles equivalent, good results relatively. In this paper, an experiment was done where the illumination sources used as the standard illumination 5200K and illuminated at a $45^{\circ}$ angle in the best illumination efficiently. The white balance was in mode 'custom' : aperture F11, exposure time 1/60s, ISO50, focal length 80mm. The images were exported and saved as 16bit RGB TIFF(AdobeRGB, sRGB, ProphotoRGB) images. To do the test, the RGB values of the RGB TIFF images are processed through the ICC input profile to arrive at processed $CIEL^*a^*b^*$ values. A profiling tool such as ProfileMaker 5.0 and Monacoprofile 4.8 are used to do this. The processed $CIEL^*a^*b^*$ values are compared to the reference $CIEL^*a^*b^*$ values and these two values are used to calculate a ${\Delta}E{^*}_{ab}$.

  • PDF

광량 변화에 강건한 가중치 국부 기술자 기반의 스테레오 정합 (Robust Stereo Matching under Radiometric Change based on Weighted Local Descriptor)

  • 구자민;김용호;이상근
    • 전자공학회논문지
    • /
    • 제52권4호
    • /
    • pp.164-174
    • /
    • 2015
  • 기하학적 특성이 주어진 두 개 이상의 카메라를 사용하거나 한 개의 카메라를 이동시켜가면서 스테레오 영상을 얻을 때에, 카메라 설정 값의 차이, 조명의 변화 등으로 인해 광량의 변화가 발생한다. 하지만 색상 유사도를 기반으로 한 기존의 스테레오 정합 방법들은 정확한 대응점을 추정하지 못한다. 본 논문에서는 광량 변화에 강건하기 위한 방법으로 스테레오 영상에서 픽셀의 밝기 정보와 그라디언트 정보 및 텍스쳐 정보를 국부 기술자로 구성하는 새로운 방법을 제안하고, 엔트로피에 기반한 적응적 가중치를 국부 기술자에 부여하여 광량 변화에도 정확한 대응점을 추정할 수 있도록 한다. 제안하는 방법은 조명의 변화, 노출 시간의 차이로 인해 광량 변화가 발생된 Middlebury의 실험 영상을 통해 실험되었으며, 광량 변화에 강건한 최근의 방법들과 비교하였다. 그 결과, 제안하는 방법은 전체 영역에서의 오정합 비율이 약 5 % 정도로 비교하는 방법들보다 낮게 발생하여 가장 좋은 성능을 보여주었다.

의료기관 핵의학 종사자의 직무 별 개인피폭선량에 관한 연구 (A Study on the Individual Radiation Exposure of Medical Facility Nuclear Workers by Job)

  • 강천구;오기백;박훈희;오신현;박민수;김정열;이진규;나수경;김재삼;이창호
    • 핵의학기술
    • /
    • 제14권2호
    • /
    • pp.9-16
    • /
    • 2010
  • 본 연구는 방사성동위원소의 의학적 이용도가 증가함에 따라 의료기관 핵의학과 방사선 관계종사자의 직무 별 방사선 이용에 대한 개인 방사선 피폭선량의 실태를 파악하여, 방사선 위험에 대해 경각심을 고취시키고, 방사선 관계종사자들에게 안전관리와 합리적인 피폭선량 관리에 도움을 주고자 분석하였다. 2007년 1월 1일부터 2009년 12월 31일까지 의료기관에서 근무하는 핵의학 방사선 관계종사자로 분류되어 개인 방사선피폭선량 측정을 정기적, 연속적으로 3년 간 조사 관리된 40명의 종사자를 대상으로 직종 별, 영상실 별, 연령 별, 선량구간 별, 직무 별 관련업무를 파악하여 심부선량에 대하여 연간평균피폭선량을 각각 분석하였다. 분석법으로는 빈도분석과 ANOVA를 시행하였다. 3년 간 영상실 별 연간피폭선량은 PET 및 PET/CT 영상실이 11.06~12.62 mSv로 가장 높은 피폭선량을 보였고, 감마카메라 주사실이 11.72 mSv로 높았으며, 직종 별 연간평균피폭선량은 임상병리사가 8.92 mSv로 가장 높았고, 방사선사 7.50 mSv, 간호사 2.61 mSv, 연구원 0.69 mSv, 접수 0.48 mSv, 의사 0.35 mSv 순으로 나타났으며, 세부업무에 따른 직무별 연간평균피폭선량은 PET 및 PET/CT 업무가 12.09 mSv로 가장 높은 피폭선량을 보였으며, 감마카메라 주사실이 11.72 mSv, 싸이크로트론 관련 합성 업무 8.92 mSv, 감마카메라 영상업무 4.92 mSv, 치료 및 안전관리 2.98 mSv, 간호사 업무 2.96 mSv, 관리 업무 1.72 mSv, 영상분석 업무 0.92 mSv, 판독업무 0.54 mSv, 접수업무 0.51 mSv, 연구업무 0.29 mSv 순으로 나타났다. 선량구간 별 연간평균피폭선량은 연구대상자의 15명(37.5%)이 1 mSv이하의 선량분포와 5명(12.5%)이 1.01~5.0 mSv이하의 선량분포를 가지고 있었고, 5.01~10.0mSv에서 14명(35.0%), 10.01~20.0 mSv에서 6명(15.0%)의 분포로 분석되었다. 연령에 따른 연간평균피폭선량은 방사선사 직종에서는 25~34세 종사자가 8.69 mSv로 가장 높은 평균선량을 보였고, 근무기간에 따른 연간평균피폭선량은 방사선사 직종에서 5~9년 종사자가 9.5 mSv로 가장 높은 평균선량을 나타냈다. 고용형태에 따른 연간평균피폭선량은 정규직 임상병리사 8.92 mSv, 방사선사 7.82 mSv, 계약직 방사선사 7.55 mSv, 인턴직 방사선사 5.62 mSv, 계약직 간호사 2.61 mSv, 정규직 연구원 0.69 mSv, 접수 0.55 mSv, 의사 0.35mSv 순으로 피폭을 받는 것으로 나타났다. 이와 같은 결과로 볼 때 의료기관에서 근무하는 핵의학 방사선 관계종사자의 대부분이 현재의 방사선 안전관리가 실효성 있게 이루어지고 있었으며, 직무특성에 따라 많은 차이가 있는 것을 알게 되었다. 그러나 방사선 피폭을 최소화시키는 노력이 필요하며, 이를 위해서 체계적 교육과 합리적 피폭량 관리를 위한 체계가 필요하다고 사료된다.

  • PDF

감마영상과 실사영상의 Fusion (Fusion of Gamma and Realistic Imaging)

  • 김윤철;유연욱;서영덕;문종운;김영석;원우재;김석기
    • 핵의학기술
    • /
    • 제14권1호
    • /
    • pp.78-82
    • /
    • 2010
  • 현재 우리나라 암발생률을 보면 유방암과 갑상샘암이 매년 빠르게 증가하고 있는 추세이다. 따라서 I-131 scan과 전초림프절 검사인 lymphoscintigraphy가 많이 시행되고 있다. 그러나 이러한 검사는 전통적인 핵의학 영상 검사들과 마찬가지로 병리생태를 영상화하는 데에는 탁월하나 해부학적 정보는 많지 않다. 따라서 트랜스미션 스캔을 실시하여 해부학적 위치를 찾는 데 도움을 주는 등 여러 방법을 사용하고 있으나 만족스럽지 못하다. 이에 착안하여 감마실사영상의 fusion으로 좀 더 해부학적 정보가 많은 영상을 구현하고자 한다. 2009년 4월부터 7월까지 본과를 내원하고 SIEMENS사의 Symbia Gamma Camera를 이용하여 lymphoscintigraphy를 시행한 환자와 I-131 추가 검사를 시행한 환자를 대상으로 하였다. 먼저 감마카메라로 촬영한 후 촬영실 천정에 설치한 hyVISION사의 소형카메라(R-2000)로 동일 위치를 촬영하여 감마영상과 소형카메라의 실사영상을 자체개발한 Gamma Ray Tool Fusion 프로그램을 이용하여 fusion하여 일치도를 평가 하였으며, 환자 및 술자의 피폭선량을 평가하였다. 술자와 환자의 피폭선량은 트랜스미션 스캔을 적용하기 위한 플러드 선원의 제작과정과 실제 트랜스미션 스캔이 적용될 때 방사선피폭이 발생되며 술자의 방사선피폭은 평균 14.1743 ${\mu}Sv$이며, 환자의 방사선피폭은 평균 0.9037 ${\mu}Sv$이다. 또한 fusion 영상에서 감마마커와 실사마커가 일치하였고 플러드 선원에 의한 피폭은 없었다. 본원에서 구축한 감마영상과 실사영상의 fusion 프로그램으로 보다 많은 해부학적 정보를 포함하고 있는 영상을 임상의 및 판독의에게 제공할 수 있고, 업무프로세스가 감소되어 편리한 조작이 가능하게 되었다. 또한 플러드 선원에 의한 피폭을 줄일 수 있어서, 다른 핵의학 검사에도 사용이 가능할 것으로 생각되어진다. 하지만 환자의 사생활이 존중되어야 하기 때문에 검사시행 전, 검사진행 과정과 장점 등을 자세하게 설명한 후 환자가 동의할 경우 검사를 실시하여야 할 것이다.

  • PDF

디지털방사선촬영술을 이용한 인접면 치아우식증 진단에 관한 실험적 연구 (A STUDY ON THE ARTIFICIAL INTERPROXIMAL CARIES DETECTION WITH THE DIGITAL RADIOGRAPHY)

  • 권기정;황의환;이상래
    • 치과방사선
    • /
    • 제24권1호
    • /
    • pp.85-94
    • /
    • 1994
  • The purposes of this study were clinical comparison and evaluation between digital radiography and conventional radiography for the detection of artificial interproximal caries. Four freshly extracted, unrestored posterior teeth were obtained and caries was simulated by drilling semicircled defects with variable size at the interproximal surface of each tooth. The experiments were performed with IBM-PC/32 bit-DX compatible, video camera(VM-S8200, Hitachi Co., Japan), and color monitor(Multisync 3D, NEC, Japan). Sylvia Image Capture Board for the ADC(analog to digital converter) was used, and spatial resolution was 512 × 480 with 256 gray levels. The obtained results were as follows: 1. At the condition of under exposure, the radiographs were superior to the digital images in readability. Also, as the size of the artificial lesion was increased, readability of the radiographs was elevated. 2. The digital images were superior to the radiographs in readability especially under over exsposure. 3. As the exposure time and size of lesion was increased, the gray level of region of interest of the digital image was decreased proportionally. 4. As the F-value of average gray level of region of interest at individual exposure time and size of lesion, gray level of the all lesion sizes was decreased in comparison with that of the normal enamel.

  • PDF