• 제목/요약/키워드: camera coordinate transform

검색결과 31건 처리시간 0.021초

A method for image processing by use of inertial data of camera

  • Kaba, K.;Kashiwagi, H.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1998년도 제13차 학술회의논문집
    • /
    • pp.221-225
    • /
    • 1998
  • This paper is to present a method for recognizing an image of a tracking object by processing the image from a camera, whose attitude is controlled in inertial space with inertial co-ordinate system. In order to recognize an object, a pseudo-random M-array is attached on the object and it is observed by the camera which is controlled on inertial coordinate basis by inertial stabilization unit. When the attitude of the camera is changed, the observed image of M-array is transformed by use of affine transformation to the image in inertial coordinate system. Taking the cross-correlation function between the affine-transformed image and the original image, we can recognize the object. As parameters of the attitude of the camera, we used the azimuth angle of camera, which is de-fected by gyroscope of an inertial sensor, and elevation an91e of camera which is calculated from the gravitational acceleration detected by servo accelerometer.

  • PDF

전자내시경 순차영상을 이용한 위에서의 카메라 위치 추정 (Camera Position Estimation in Castor Using Electroendoscopic Image Sequence)

  • 이상경;민병구
    • 대한의용생체공학회:의공학회지
    • /
    • 제12권1호
    • /
    • pp.49-56
    • /
    • 1991
  • In this paper, a method for camera position estimation in gasher using elechoendoscopic image sequence is proposed. In orders to obtain proper image sequences, the gasser in divided into three sections. It Is presented thats camera position modeling for 3D information extvac lion and image distortion due to the endoscopic lenses is corrected. The feature points are represented with respect to the reference coordinate system below 10 percents error rate. The faster distortion correction algorithm is proposed in this paper. This algorithm uses error table which is faster than coordinate transform method using n -th order polynomials.

  • PDF

폐기물 매립위치의 검출을 위한 매립차량 궤적 추적 계산 및 카메라 좌표변환 (Calculation of Dumping Vehicle Trajectory and Camera Coordinate Transform for Detection of Waste Dumping Position)

  • 이동규;이영대;조성윤
    • 한국인터넷방송통신학회논문지
    • /
    • 제13권1호
    • /
    • pp.243-249
    • /
    • 2013
  • 폐기물 환경 시설에서 폐기물 운반 차량의 폐기물 매립장 내 이동 경로와 폐기물 투척 위치를 추적하여 기록함으로써 향 후 폐기물 매립지 재사용을 위한 이력관리를 효율적으로 진행할 수 있다. 이들 폐기물 매립 위치 정보들을 3D 로 매핑하고 위치를 추출하여 최종 매립위치와 매립물 기록을 추출하기 위한 새로운 연구 방법이 다양한 실험조건하에서 구현되었다. 본 연구에서는 쓰레기 매립장 내에서의 차량의 이동경로와 매립시점을 판단할 수 있는 방법을 제시한다. 현재의 영상과 배경영상의 차를 구하여 차량의 이동경로를 추적하고 이동경로의 형태로부터 정차 여부를 판단할 수 있으며, 정차시의 영상과 배출구의 개방영상과의 비교를 통해 폐기물의 매립시점을 검출할 수 있도록 한다. 감시 카메라의 설치정보를 이용하며 매립지 평면상의 좌표와 화면좌표를 변환할 수 있는 방법을 제시한다.

듀얼 모드(고정형+PTZ 카메라) 감시 카메라를 이용한 효과적인 화상 감시 시스템에 관한 연구 (Study on Effective Visual Surveillance System using Dual-mode(Fixed+Pan/Tilt/Zoom) Camera)

  • 김기석;이삭;박종섭;조재수
    • 제어로봇시스템학회논문지
    • /
    • 제18권7호
    • /
    • pp.650-657
    • /
    • 2012
  • An effective dual-mode camera system(a passive wide-angle camera and a pan-tilt-zoom camera) is proposed in order to improve the performance of visual surveillance. The fixed wide-angle camera is used to monitor large open areas, but the moving objects on the images are too small to view in detail. And, the PTZ camera is capable of increasing the monitoring area and enhancing the image quality by tracking and zooming in on a specific moving target. However, its FOV (Field of View) is limited when zooming in on a specific target. Therefore, the cooperation of wide-angle and PTZ cameras is complementary. In this paper, we propose an automatic initial set-up algorithm and coordinate transform method from the wide-angle camera coordinate to the PTZ one, which are necessary to achieve the cooperation. The automatic initial set-up algorithm is able to synchronize the views of two cameras. When a moving object appears on the image plane of a wide-angle camera after the initial set-up positioning, the obtained values of the wide-angle camera should be transformed to the PTZ values based on the coordinate transform method. We also develope the PTZ control method. Various in-door and out-door experiments show that the proposed dual-camera system is feasible for the effective visual surveillance.

Multiple crack evaluation on concrete using a line laser thermography scanning system

  • Jang, Keunyoung;An, Yun-Kyu
    • Smart Structures and Systems
    • /
    • 제22권2호
    • /
    • pp.201-207
    • /
    • 2018
  • This paper proposes a line laser thermography scanning (LLTS) system for multiple crack evaluation on a concrete structure, as the core technology for unmanned aerial vehicle-mounted crack inspection. The LLTS system consists of a line shape continuous-wave laser source, an infrared (IR) camera, a control computer and a scanning jig. The line laser generates thermal waves on a target concrete structure, and the IR camera simultaneously measures the corresponding thermal responses. By spatially scanning the LLTS system along a target concrete structure, multiple cracks even in a large scale concrete structure can be effectively visualized and evaluated. Since raw IR data obtained by scanning the LLTS system, however, includes timely- and spatially-varying IR images due to the limited field of view (FOV) of the LLTS system, a novel time-spatial-integrated (TSI) coordinate transform algorithm is developed for precise crack evaluation in a static condition. The proposed system has the following technical advantages: (1) the thermal wave propagation is effectively induced on a concrete structure with low thermal conductivity of approximately 0.8 W/m K; (2) the limited FOV issues can be solved by the TSI coordinate transform; and (3) multiple cracks are able to be visualized and evaluated by normalizing the responses based on phase mapping and spatial derivative processes. The proposed LLTS system is experimentally validated using a concrete specimen with various cracks. The experimental results reveal that the LLTS system successfully visualizes and evaluates multiple cracks without false alarms.

종합병원관리 전산화 System-MEDIOS

  • 이승훈
    • 대한의용생체공학회:의공학회지
    • /
    • 제3권1호
    • /
    • pp.55-58
    • /
    • 1982
  • In this paper, a method for camera position estimation in gaster using elechoendoscopic image sequence is proposed. In order to obtain proper image sequences, the gaster in divided into three sections. It is presented that camera position modeling for 3D information extraction and image distortion due to the endoscopic lenses is corrected.The feature points are represented with respect to the reference coordinate system belpw 10 percents error rate. The faster distortion correction algorithm is proposed in this paper. This algorithm uses error table which is faster than coordinate transform method using n-th order polynomials.

  • PDF

스테레오 영상을 이용한 3차원 표면좌표 추출 알고리즘 (Extraction of the three-dimensional surface coordinate from a stereo image)

  • 원성혁;김민기;김병우;이기식;김헌배
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 하계종합학술대회 논문집(4)
    • /
    • pp.210-213
    • /
    • 2000
  • In the closed range space, the parallel two CCD cameras are used to acquire a pair of stereo image. The acquired stereo image are computed with Wavelet Transform repeatedly and including the low frequency component, the image size of those are reduced. It is the pyramid structure. The optimum matching point is searched to the pixel. Then appling the optimum matching point to DLT, it extract the three - dimensional surface coordinate from a stereo image. The direct linear transformation(DLT) method is used to calibrate the stereo camera compute the coordinate on a three dimensional space. To find the parameters for the DLT method, 30 control points which marked on the cylinder type object are used. To improve the matching algorithm, the paper select the pyramid structure for Wavelet Transform. The acquired disparity information is used to represent the really three-dimensional surface coordinate.

  • PDF

호모지니어스 좌표계를 이용한 3차원 스테레오 PIV 알고리듬의 개발 (Development of 3-D Stereo PIV by Homogeneous Coordinate System)

  • 김미영;최장운;남구만;이영호
    • 대한기계학회논문집B
    • /
    • 제27권6호
    • /
    • pp.736-743
    • /
    • 2003
  • A process of 3-D particle image velocimetry, called here, as '3-D stereo PIV' was developed for the measurement of an illuminated slied section field of 3-D complex flows. The present method includes modeling of camera by a calibrator based on the homogeneous coordinate system, transfromation of the oblique-angled image to the right-angled image, identification of 2-D velocity vectors by 2-D cross-correlation equation, stereo matching of 2-D velocity vectors of two cameras, accurate calculation of 3-D velocity vectors by homogeneous coordinate system, removal of error vectors by a statistical method followed by a continuity equation criterior, and finally 3-D animation as the post processing. An experimental system was also used for the application of the proposed method. Three analog CCD cameras and an Argon-Ion Laser(300mW) for illumination were adopted to capture the wake flow behind a bluff obstacle.

다층퍼셉트론의 정합 근사화에 의한 2차원 영상의 카메라 오차보정 (A 2-D Image Camera Calibration using a Mapping Approximation of Multi-Layer Perceptrons)

  • 이문규;이정화
    • 제어로봇시스템학회논문지
    • /
    • 제4권4호
    • /
    • pp.487-493
    • /
    • 1998
  • Camera calibration is the process of determining the coordinate relationship between a camera image and its real world space. Accurate calibration of a camera is necessary for the applications that involve quantitative measurement of camera images. However, if the camera plane is parallel or near parallel to the calibration board on which 2 dimensional objects are defined(this is called "ill-conditioned"), existing solution procedures are not well applied. In this paper, we propose a neural network-based approach to camera calibration for 2D images formed by a mono-camera or a pair of cameras. Multi-layer perceptrons are developed to transform the coordinates of each image point to the world coordinates. The validity of the approach is tested with data points which cover the whole 2D space concerned. Experimental results for both mono-camera and stereo-camera cases indicate that the proposed approach is comparable to Tsai's method[8]. Especially for the stereo camera case, the approach works better than the Tsai's method as the angle between the camera optical axis and the Z-axis increases. Therefore, we believe the approach could be an alternative solution procedure for the ill -conditioned camera calibration.libration.

  • PDF

3차원 스테레오 PIV 개발 (Development of 3-D Stereo PIV)

  • 김미영;최장운;남구만;이영호
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2002년도 추계학술대회 논문집
    • /
    • pp.19-22
    • /
    • 2002
  • A process of 3-D particle image velocimetry, called here, as '3-D stereo PIV' was developed for the measurement of a section field of 3-D complex flows. The present method includes modeling of camera by a calibrator based on the homogeneous coordinate system, transfromation of oblique-angled image to transformed image, identification of 2-D velocity vectors by 2-D cross-correlation equation, stereo matching of 2-D velocity vectors of two cameras, accurate calculation of 3-D velocity vectors by homogeneous coordinate system and finally 3-D animation as the post processing. In principle, as two frame images only are necessary for the single instantaneous analysis of a section field of 3-D flow, more effective vectors are obtainable contrary to the previous multi-frame vector algorithm. An experimental system was also used for the application of the proposed method. Three analog CCD cameras and an Argon-Ion Laser(300mW) for illumination were adopted to capture the wake flow behind a bluff obstacle.

  • PDF