• Title/Summary/Keyword: camera

Search Result 10,557, Processing Time 0.05 seconds

Response of Structural, Biochemical, and Physiological Vegetation Indices Measured from Field-Spectrometer and Multi-Spectral Camera Under Crop Stress Caused by Herbicide (마늘의 제초제 약해에 대한 구조적, 생화학적, 생리적 계열 식생지수 반응: 지상분광계 및 다중분광카메라를 활용하여)

  • Ryu, Jae-Hyun;Moon, Hyun-Dong;Cho, Jaeil;Lee, Kyung-do;Ahn, Ho-yong;So, Kyu-ho;Na, Sang-il
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.6_1
    • /
    • pp.1559-1572
    • /
    • 2021
  • The response of vegetation under the crop stress condition was evaluated using structural, biochemical, and physiological vegetation indices based on unmanned aerial vehicle (UAV) images and field-spectrometer data. A high concentration of herbicide was sprayed at the different growth stages of garlic to process crop stress, the above ground dry matter of garlic at experimental area (EA) decreased about 46.2~84.5% compared to that at control area. The structural vegetation indices clearly responded to these crop damages. Spectral reflectance at near-infrared wavelength consistently decreased at EA. Most biochemical vegetation indices reflected the crop stress conditions, but the meaning of physiological vegetation indices is not clear due to the effect of vinyl mulching. The difference of the decreasing ratio of vegetation indices after the herbicide spray was 2.3% averagely in the case of structural vegetation indices and 1.3~4.1% in the case of normalization-based vegetation indices. These results meant that appropriate vegetation indices should be utilized depending on the types of crop stress and the cultivation environment and the normalization-based vegetation indices measured from the different spatial scale has the minimized difference.

A Study for Analysis of Image Quality Based on the CZT and NaI Detector according to Physical Change in Monte Carlo Simulation (CZT와 NaI 검출기 물질 기반 물리적 변화에 따른 영상의 질 분석에 관한 연구: 몬테카를로 시뮬레이션)

  • Ko, Hye-Rim;Yoo, Yu-Ri;Park, Chan-Rok
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.5
    • /
    • pp.741-748
    • /
    • 2021
  • In this study, we evaluated image quality by changing collimator length and detector thickness using the Geant4 Application for Tomographic Emission (GATE) simulation tool. The gamma camera based on the Cadimium Zinc Telluride (CZT) and NaI detectors is modeled. In addition the images were acquired by setting 1, 2, 3, 4, 5, and 6 cm collimator length and 1, 3, 5, and 7 mm detector thickness using point source and phantom, which is designed by each diameter (4.45, 3.80, 3.15, 2.55 mm) with 447, 382, 317, and 256 Bq. The sensitivity (cps/MBq) for point source, and signal to noise ratio (SNR) and profile for phantom at the 4.45 mm by drwan the region of interests were used for quantitative analysis. Based on the results, the sensitivity according to collimator length is 2.3 ~ 48.6 cps/MBq for CZT detector, and 1.8 ~ 43.9 cps/MBq for NaI detector. The SNR using phantom is 3.6~9.8 for CZT detector, and 2.9~9.5 for NaI detector. As the collimator length is increased, the image resolution is also improved according to profile results based on the CZT and NaI detector. In addition, the senistivity for detector thickness is 0.04 ~ 0.12 cps/MBq for CZT detector, and 0.03 ~ 0.11 cps/MBq. The SNR using phnatom is 7.3~9.8 count for CZT detector, and 5.9~9.5 for NaI detector. As the detector thickness is increased, the image resolution is decreased according to profile results based on the CZT and NaI detector due to scatter ray. In conclusion, we need to set the geometric material such as detector and collimator to acuquire suitable image quality in nuclear medicine.

Development of Deep Learning Structure to Improve Quality of Polygonal Containers (다각형 용기의 품질 향상을 위한 딥러닝 구조 개발)

  • Yoon, Suk-Moon;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.25 no.3
    • /
    • pp.493-500
    • /
    • 2021
  • In this paper, we propose the development of deep learning structure to improve quality of polygonal containers. The deep learning structure consists of a convolution layer, a bottleneck layer, a fully connect layer, and a softmax layer. The convolution layer is a layer that obtains a feature image by performing a convolution 3x3 operation on the input image or the feature image of the previous layer with several feature filters. The bottleneck layer selects only the optimal features among the features on the feature image extracted through the convolution layer, reduces the channel to a convolution 1x1 ReLU, and performs a convolution 3x3 ReLU. The global average pooling operation performed after going through the bottleneck layer reduces the size of the feature image by selecting only the optimal features among the features of the feature image extracted through the convolution layer. The fully connect layer outputs the output data through 6 fully connect layers. The softmax layer multiplies and multiplies the value between the value of the input layer node and the target node to be calculated, and converts it into a value between 0 and 1 through an activation function. After the learning is completed, the recognition process classifies non-circular glass bottles by performing image acquisition using a camera, measuring position detection, and non-circular glass bottle classification using deep learning as in the learning process. In order to evaluate the performance of the deep learning structure to improve quality of polygonal containers, as a result of an experiment at an authorized testing institute, it was calculated to be at the same level as the world's highest level with 99% good/defective discrimination accuracy. Inspection time averaged 1.7 seconds, which was calculated within the operating time standards of production processes using non-circular machine vision systems. Therefore, the effectiveness of the performance of the deep learning structure to improve quality of polygonal containers proposed in this paper was proven.

Comparison of the effect of removing artificial dental plaque depending on various interdental cleaning products on the interdental surface of zirconia crowns (치간 세정 용품에 따른 지르코니아 크라운 인접면의 인공 치면 세균막 제거 효과)

  • Kim, Hyun-Wook;Song, Ha-Kyung;Park, Eun-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.3
    • /
    • pp.291-298
    • /
    • 2021
  • Purpose. The purpose of this study is to compare five interdental cleansing products' effectiveness on removing artificial dental plaque on the interdental space of zirconia crowns. Materials and methods. A model with abutments on the right mandibular second premolar and first molar were prepared. 10 zirconia crowns for each abutment were fabricated. After applying artificial dental plaque between the zirconia crowns, a single clinician attempted to remove the plaque with five products: interdental toothbrush, end-tuft toothbrush, dental floss, Easypick, Water pik. They were conducted 10 times per group. The aspect and area of removed surfaces were analyzed using images taken with a digital camera. One factor analysis of variance was performed as a statistical analysis, and a post-hoc test was performed using the Scheffé method (P < .05). Results. There were differences in the area and the pattern according to the characteristics of the products. The largest area, including the marginal portion, was removed in the dental floss group. Interdental toothbrush group was the most effective in removing the dental plaque at the marginal portion. Easypick was less effective than the interdental toothbrush. The end-tuft toothbrush showed better results than other products in cleansing mesiobuccal and distobuccal area, but could not cleanse the area directly below the contact point. In Water pik group, artificial dental plaque was scarcely removed. The removal rate of artificial dental plaque was in the order of floss (69.47%), end-tuft toothbrush (49.36%), interdental toothbrush (44.20%), Easy pick (13.04%), and Water pik (0.59%). Conclusion. Dental floss showed the highest removal rate in the interdental space restored with zirconia crowns, while interdental toothbrush was the most effective in removing the dental plaque at the marginal portion.

3D Histology Using the Synchrotron Radiation Propagation Phase Contrast Cryo-microCT (방사광 전파위상대조 동결미세단층촬영법을 활용한 3차원 조직학)

  • Kim, Ju-Heon;Han, Sung-Mi;Song, Hyun-Ouk;Seo, Youn-Kyung;Moon, Young-Suk;Kim, Hong-Tae
    • Anatomy & Biological Anthropology
    • /
    • v.31 no.4
    • /
    • pp.133-142
    • /
    • 2018
  • 3D histology is a imaging system for the 3D structural information of cells or tissues. The synchrotron radiation propagation phase contrast micro-CT has been used in 3D imaging methods. However, the simple phase contrast micro-CT did not give sufficient micro-structural information when the specimen contains soft elements, as is the case with many biomedical tissue samples. The purpose of this study is to develop a new technique to enhance the phase contrast effect for soft tissue imaging. Experiments were performed at the imaging beam lines of Pohang Accelerator Laboratory (PAL). The biomedical tissue samples under frozen state was mounted on a computer-controlled precision stage and rotated in $0.18^{\circ}$ increments through $180^{\circ}$. An X-ray shadow of a specimen was converted into a visual image on the surface of a CdWO4 scintillator that was magnified using a microscopic objective lens(X5 or X20) before being captured with a digital CCD camera. 3-dimensional volume images of the specimen were obtained by applying a filtered back-projection algorithm to the projection images using a software package OCTOPUS. Surface reconstruction and volume segmentation and rendering were performed were performed using Amira software. In this study, We found that synchrotron phase contrast imaging of frozen tissue samples has higher contrast power for soft tissue than that of non-frozen samples. In conclusion, synchrotron radiation propagation phase contrast cryo-microCT imaging offers a promising tool for non-destructive high resolution 3D histology.

A study on the utilization of drones and aerial photographs for searching ruins with a focus on topographic analysis (유적탐색을 위한 드론과 항공사진의 활용방안 연구)

  • Heo, Ui-Haeng;Lee, Wal-Yeong
    • Korean Journal of Heritage: History & Science
    • /
    • v.51 no.2
    • /
    • pp.22-37
    • /
    • 2018
  • Unmanned aerial vehicles (UAV) have attracted considerable attention both at home and abroad. The UAV is equipped with a camera that shoots images, which is advantageous for access to areas where archaeological investigations are not possible. Moreover, it is possible to acquire three-dimensional spatial image information by modeling the terrain through aerial photographing, and it is possible to specify the interpretation of the terrain of the survey area. In addition, if we understand the change of the terrain through comparison with past aerial photographs, it will be very helpful to grasp the existence of the ruins. The terrain modeling for searching these remains can be divided into two parts. First, we acquire the aerial photographs of the current terrain using the drone. Then, using image registration and post-processing, we complete the image-joining and terrain-modeling using past aerial photographs. The completed modeled terrain can be used to derive several analytical results. In the present terrain modeling, terrain analysis such as DSM, DTM, and altitude analysis can be performed to roughly grasp the characteristics of the change in the form, quality, and micro-topography. Past terrain modeling of aerial photographs allows us to understand the shape of landforms and micro-topography in wetlands. When verified with actual findings and overlapping data on the modelling of each terrain, it is believed that changes in hill shapes and buried Microform can be identified as helpful when used in low-flying applications. Thus, modeling data using aerial photographs is useful for identifying the reasons for the inability to carry out archaeological surveys, the existence of terrain and ruins in a wide area, and to discuss the preservation process of the ruins. Furthermore, it is possible to provide various themes, such as cadastral maps and land use maps, through comparison of past and present topographical data. However, it is certain that it will function as a new investigation methodology for the exploration of ruins in order to discover archaeological cultural properties.

Quality Evaluation of UAV Images Using Resolution Target (해상도 타겟을 이용한 무인항공영상의 품질 평가)

  • LEE, Jae-One;SUNG, Sang-Min
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.22 no.1
    • /
    • pp.103-113
    • /
    • 2019
  • Spatial resolution is still one of the most important parameters for evaluating image quality. In this study, we propose an approach to evaluate spatial resolution and MTF(Modulation Transfer Function) using bar target and Siemens star chart as a part of quality evaluation for UAV images. To this end, images were taken with a fixed-wing eBee(Canon IXUS) at the flight height of 130m and 260m, and with a rotary-wing GD-800(SONY NEX-5N) at flight height of 130m, with a Phantom 4 pro(FC 6310) at flight height of 90m, respectively. Spatial resolution was measured on orthoimages produced from this data. Results show that the resolution measured on the Siemens star and bar target was accurately degraded in proportion to the flight height regardless of the cameras. In the words, the spatial resolution of images taken at the same altitude of 130m with the eBee(Canon IXUS) and the GD-800(SONY NEX-5N) equipped with different cameras was the same as 4.1cm, and that of the eBee(Canon IXUS) at 260m was 8.0cm. In addition, the resolution measured on the Siemens star was about 1~2cm lower than that of the bar target at every flight height. The general tendency was also found to be proportional to the flight height in the measurement of the ${\sigma}_{MTF}$ from MTF, which simultaneously represents the resolution and contrast information of the image. However, at the same altitude of 130m, the ${\sigma}_{MTF}$ of the GD-800(SONY NEX-5N) is 0.36 and the eBee(Canon IXUS) is 0.59, which shows that the GD-800(SONY NEX-5N) has better camera performance. It is expected that study results will contribute to the analysis of spatial resolution of UAV images and to improve the reliability of quality.

Long-Term Trend Analysis in Nuclear Medicine Examinations (핵의학 영상 검사의 중장기 추세 분석 - 서울 소재 일개 상급 종합병원을 중심으로 -)

  • Jung, Woo-Young;Shim, Dong-Oh;Choi, Jae-Min
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.15-28
    • /
    • 2019
  • Purpose Nuclear medicine was initially introduced in Korea in 1969 and widely applied to treat hyperthyroidism with $^{131}I$. Also, gamma camera was adopted in 1969 in the first place and its application has been growing continually in many ways. We analyzed long-term trend in nuclear medicine examinations for the last 2 decades. The purpose of this paper is to make predictions and to set both plans and directions on the development of nuclear medicine. Materials and Methods We analyzed the performance of nuclear medicine examinations and therapies performed in Asan Medical Center from 1998 to 2017. Results Results from the last 20 years regarding Bone scan, Renal scan, MUGA scan and $^{18}F$-FPCIT, Bone Mineral Density were on a increase. And Myocardium perfusion SPECT, Thyroid scan, Lung scan were on a decrease while $^{18}F-FDG$ PET maintained on a steady course. Until 2010 there was a positive performance with the therapy but after the excessive medical care in thyroid examination performance is at status quo. Key events such as a medical strike(2000), Middle-East Respiratory Syndrome (2015) influenced the overall performance of the therapy. Conclusion In order to promote a long-term growth in nuclear medicine examination and therapy, it is inevitable to respond to the changes in current medical environment. Furthermore, it is strongly suggested to put efforts to maintain and develop new examinations and clinical indicators.

Optimization of GFR value according to Kidney Depth Measurement Methods (신장 Depth 측정 방법에 따른 GFR 값의 최적화)

  • Kwon, Hyeong-Jin;Moon, Il-Sang;Noh, Gyeong Woon;Kang, Keon Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.2
    • /
    • pp.25-28
    • /
    • 2019
  • Purpose In patients with unusual kidney position after $^{99m}Tc-DTPA$ renal dynamic imaging study, the GFR(Glomerular Filtration Rate) values are significantly different according to the depth of the kidney. Thus, we tried to compare the difference of the GFR values between the depth measurement methods and in-vitro test. 30 adult patients who were subjected to renal study. 27 patients were in usual position and 3 patients were in unusual. $555{\pm}37MBq$ of $^{99m}Tc-DTPA$ was administrated to all patients. GE infinia gamma camera was used. GFR values were obtained in-vivo(gates method) and in-vitro(blood). The kidney depth in-vivo was calculated by three methods(tonnensen, manual, taylor). In-vitro, GFR was performed by blood test. Differences in the mean values of GFR and correlation between depth and GFR values were evaluated using the SPSS 12.0 statistical program. The GFR values for 27 patients with kidney in the usual position are as follows(1.tonnensen 2.manual 3.taylor 4.invitro); $69.3{\pm}4.2$, $88.2{\pm}5.6$, $77.8{\pm}4.3$, $82.2{\pm}5.8ml/min$. The three unusual cases are as follows, first(congenital renal anomaly): 66.4, 101.24, 69.07, 94.8 ml/min. second(transplantation kidney): 12.22, 29.99, 19.36, 23.5 ml/min. third(horseshoe kidney): 37.37, 93.54, 35.9, 92.5 ml/min. There was a difference between tonnensen and manual in the usual position of the kidney(p<0.05). There was no significant difference between the other methods. However, there was a significant difference in case of the unusual position of the kidneys. Correlation analysis between both kidney depth and GFR value shows person correlation as follows; Rt kidney: 0.298, Lt kidney: 0.322. When compared with the GFR values in-vitro test, it was useful to calculate the GFR value by measuring the kidney depth using a manual formula in the unusual position of the kidneys. GFR values and kidney depth were significantly related.

Analysis of esthetic factors and evaluation of esthetic perception for maxillary anteriors of dental students (치과대학생의 상악 전치부의 심미적 요소 분석 및 인식도 평가)

  • Kim, Seon-Kyung;Kim, Ok-Su
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.2
    • /
    • pp.118-126
    • /
    • 2019
  • Purpose: This research is to investigate factors that affect dental aesthetics and analyze whether individual perception affects and difference of genders affects the esthetic factors. Materials and methods: Seventy dental students of Chonnam University aged from 25 to 35 years old without periodontal problems were included. Maxillary dental cast for participants were made, and standardized photo was taken with a digital camera. Maximum visual width and the position of gingival zenith of maxillary anterior teeth and maximum height of the maxillary central incisors were measured by a measurement program and the shape of central incisor was categorized. Questionnaire was conducted to evaluate esthetic perception. SPSS program was used to perform statistical analysis. Results: The average visual width ratio of right maxillary anteriors was 1.38:1:0.78 and 1.41:1:0.81 for the left which differ from the golden ratio. The width to height ratio for right and left central incisor was 0.84 and 0.83 respectively. The gingival zenith position was determined to be: mostly, central incisors and canines were located in the distal side, lateral incisors were located in the center. The visual width ratio of right maxillary anterior teeth, ratio of width to height of central incisor, gingival zenith position, crown morphology and amounts of gingival exposure upon smiling were not significantly different between genders, and facial patterns and these dental esthetic factors were not related to aesthetic perception. Conclusion: Even though participants had the visual width ratio of maxillary anteriors or ideal width to ideal height of central incisors that did not agree with the golden ratio, they had high satisfaction for dental esthetics. Esthetic perception depends more on subjective judgements of participants than objective indices.