• 제목/요약/키워드: calibrator

검색결과 107건 처리시간 0.029초

A Fully Differential RC Calibrator for Accurate Cut-off Frequency of a Programmable Channel Selection Filter

  • Nam, Ilku;Choi, Chihoon;Lee, Ockgoo;Moon, Hyunwon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제16권5호
    • /
    • pp.682-686
    • /
    • 2016
  • A fully differential RC calibrator for accurate cut-off frequency of a programmable channel selection filter is proposed. The proposed RC calibrator consists of an RC timer, clock generator, synchronous counter, digital comparator, and control block. To verify the proposed RC calibrator, a six-order Chebyshev programmable low-pass filter with adjustable 3 dB cut-off frequency, which is controlled by the proposed RC calibrator, was implemented in a $0.18-{\mu}m$ CMOS technology. The channel selection filter with the proposed RC calibrator draws 1.8 mA from a 1.8 V supply voltage and the measured 3 dB cut-off frequencies of the channel selection LPF is controlled accurately by the RC calibrator.

KVN phase Calibrator Survey (KVNCS) : flux estimation from Single Dish observation with KVN

  • 이정애;손봉원;변도영;이지원;박푸른;김민중;박송연;정태현
    • 천문학회보
    • /
    • 제36권2호
    • /
    • pp.133.2-133.2
    • /
    • 2011
  • KVN phase Calibrator Survey(KVNCS)는 VLBI 관측 시 대기의 불규칙한 수증기 분포로 인한 visibility 위상의 불규칙한 변화를 보정하기 위해 도입되는 phase-referencing 기법 등에서 필수요소인 위상보정 calibrator를 얻기 위한 연구이다. Phase-referencing 기법을 이용하여 위상을 보정하기 위해서는 대상 천체의 근접한 곳에 비교적 compact한 calibrator가 존재해야 한다. 또한 Asaki et al.(1996)에 의하면 대기의 coherence structure가 유지되기 위해서는 두 천체가 적어도 $5^{\circ}$ 이내의 분리각을 가져야 한다. 위상보정 calibrator에 대한 연구는 주로 2, 8GHz 대역에서 진행되어 왔고 최근에는 22GHz에서 VLBI 관측이 진행되고 있지만 천구상의 특정 영역에 국한되거나 calibrator들 간의 분리각이 여전히 크다. KVNCS는 천구상에서 calibrator의 분포를 좀 더 고르게 하고 더 많은 calibrator를 얻어 적어도 $5^{\circ}$ 이내의 분리각을 구현하고자 한다. 먼저, 단일경을 이용하여 KVNCS의 대상을 확보하기위하여 이들의 플럭스를 정확히 측정하였다. 2, 8GHz 대역에서 관측된 VLBA(Very Long Baseline Array) Calibrator Survey(VCS) 목록을 기초로 power-law를 가정하여 22GHz에서 100mJy 이상일 것으로 예상되는 천체 2503개를 KVNCS 단일경 연구의 후보로 선정하였다. KVN 연세와 울산 전파망원경경을 이용하여 2009년 12월부터 2011년 3월까지 2298개의 플럭스 측정 관측을 진행하여 22GHz에서 약 77%, 43GHz에서 약 23%의 검출률을 얻었다. 또한 이 천체들의 공간분포도 $5^{\circ}$의 분리각을 만족하는 것을 확인하였다. 앞으로 KVNCS 단일경 결과를 활용하여 KVN 각 사이트의 위치 정보를 비롯하여 22GHz KVN VLBI 관측을 통해 KVN 위상보정 calibrator를 확보 할 계획이다.

  • PDF

Setup of standard PD calibrator and its uncertainties

  • Kim, Kwang-Hwa;Yi, Sang-Hwa;Lee, Heun-Jin;Kang, Dong-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권5호
    • /
    • pp.677-683
    • /
    • 2011
  • The present paper describes the setup of standard partial discharge calibrator for measuring partial discharge and estimating uncertainties. The standard PD calibrator was designed and set up, consisting of a digital pulse generator, capacitor modules, and a digital oscilloscope controlled by software developed in the laboratory. Using this software, averages of charges and rising times and their standard deviations in the measured pulses can also be calculated. The standard PD calibrator generates five types of pulses: single, double, random, oscillating, and long-rising. The coefficient sensitivities to estimate the uncertainties of pulses were extracted in the model circuit of the standard PD calibrator. The uncertainties of charges and rising times in pulses of the standard PD calibrator were estimated with single pulses. These values were 0.3%-1.4% in charges and 1.9%-7.0% in rising time; however, these values are lower than the limit values in IEC 60270.

장비정도관리에 Calibrator[I-125] Set 적용 (The Application of New Calibrator[I-125]Set for Equipment Quality Management)

  • 김지나;안재석;원우재
    • 핵의학기술
    • /
    • 제19권2호
    • /
    • pp.108-111
    • /
    • 2015
  • Purpose Lately, in accordance with the increasing interest about Healthcare accreditation program and International laboratory accreditation scheme, requirements about the instrument quality management are gradually taking shape. In nuclear medicine In vitro laboratory, the most typical instruments are multi detector gamma counter and automatic dispensing system. Each laboratory continue with the quality control adequate for circumstances. The purpose of this study is to application and establish the new Calibrator[I-125]Set which is efficient at standardization of equipment quality management. Materials and Methods Deviation between detectors were measured with 12 solid samples of the Calibrator[I-125]Set. their activities differ from each other by less than 1%. Multi detector gamma counters are GAMMA-10;Shinjin medics. Inc, Goyansi, Korea(Gamma counter A), SR300;Stratec biomedical systems AG, Gewerbestr, Germany(Gamma counter B) and COBRA II; Packard Instrument Co. Inc, Meriden, USA(Gamma counter C). Evaluation of two automatic dispensing system used A, B liquid tracer of the Calibrator[I-125]Set. After dispensing and counting, calculated using the ratio of the measured value and proposed value. We used solution A for 20, 25ul and solution B for 50, 100ul. Method of data analysis and reference range was provided by kit documentation. Furthermore, we could calculate our counter efficiency indirectly. Results The CV(%) of measured values by Gamma counter A, B, C are 0.34, 0.70, 1.30. Calculated value are 1.05314, 2.10419, 4.08485. Provided reference range is less than 3. A dispensing system's calculated values are 0.986, 0.989, 1.023, 1.017 and B are 0.874, 0.725, 1.021, 0.904. Provided reference range is from 0.95 to 1.05. Also, counter's efficiency are 74.18, 72.79, 74.32% at counter A, B, C and efficiency of the one detector counter is 79.26%. Conclusion If using this Calibrator[I-125]Set after verifying whether quality assurance, is applicable to equipment quality management on behalf of the role of gold standard.

  • PDF

3D 프린터를 이용한 Dose Calibrator의 품질관리 (Quality Control of Dose Calibrator using 3D Printery)

  • 류찬주
    • 한국방사선학회논문지
    • /
    • 제15권3호
    • /
    • pp.307-312
    • /
    • 2021
  • 핵의학에서 Dose calibrator는 단일 핵종의 방사능을 측정하기 위해 사용하는 장비이다. 인체에 정확한 용량의 투여는 진단과 치료에 중요한 요인으로 작용하며, 투여 전 Dose calibrator를 통한 방사능 측정은 가장 중요한 요소이다. 이러한 Dose calibrator는 각 의료기관에서 설치 후 일상적인 정도 관리를 시행한다. 정도관리는 설치 후 품질관리를 보증하는 하나의 방편이며 진료의 질을 향상시키고 환자의 안전을 도모하는 데 필수적이다. 이에 정확하고 표준화된 성능 평가 방법을 구축해야 한다. 따라서 본 연구는 정도관리의 정확도와 기준성을 높여 품질 관리의 정량적 평가를 위해 3D 프린트를 이용하였다. 연구 방법은 정도관리를 위한 Q.C 표준선원이 중앙에 장착될 수 있는 3D 프린트를 이용한 보조기구를 재작하였다. 재현성 검사를 시행하였을 때 3D 프린트의 장착 유무에 따른 정도관리 선원의 오차율 값의 차이를 비교하였다. 연구 결과 표준선원의 정도관리 기댓값과 판독값의 오차 범위가 F-18 핵종에서는 0.302% 감소하였고, 99mTc-pertechneate 핵종에서는 0.09% 로 나타났다. 향후 정량적이고 표준화된 정도관리를 통해 장비의 노후화, 표준선원의 반감기에 따른 계산 오류 등 정도관리의 영향을 주는 요인을 감소시키고 정확한 방사성의약품을 투여할 수 있는 기본적인 요인으로 작용할 수 있을 것이라 사료된다.

KVN Calibrator Survey (KVNCS) : 플럭스 측정

  • 이정애;손봉원;변도영;이지원;박푸른;김민중;박송연;정태현
    • 천문학회보
    • /
    • 제35권2호
    • /
    • pp.60.2-60.2
    • /
    • 2010
  • 대기의 불규칙한 수증기 분포로 인해 VLBI 관측시 visibility 위상에 불규칙한 변화가 발생한다. 이를 보정하기 위해 phase-referencing 기법 등을 이용할 수 있다. KVN calibrator survey는 Phase-referencing 기법에 필수적인 위상보정 calibrator를 얻기 위한 연구이다. 2, 8GHz 대역에서 관측된 VLBA(Very Long Baseline Array) Calibrator Survey(VCS) 목록을 기초로 power-law를 가정하여 22GHz에서 100mJy 이상일 것으로 예상되는 천체 2503개를 KVN Calibrator Survey의 대상으로 선정하였다. 먼저 KVN 연세 전파망원경을 이용하여 2009년 12월부터 2010년 6월까지 22GHz에서 500mJy 이상으로 예상되는 천체 595개에 대한 플럭스 측정 관측을 진행하였고 22GHz에서 517개, 43GHz에서 226개의 천체를 검출하였다. 이어 200mJy 이상 500mJy 미만으로 예상되는 천체 983개에 대하여 추가 관측을 진행하고 있다. 그리고 플럭스가 측정된 천체들에 대하여 VLBI Exploration of Radio Astrometry(VERA)와 VLBA, 각각 K밴드에서 관측된 결과와 비교하여 중복되지 않은 천체들에 대해 VLBI 관측을 수행하여 천체의 위치와 구조에 대한 정보를 얻을 계획이다.

  • PDF

전기식 온도 교정기 교정기법 연구 (A Study on the Calibration Technique of an Electrical Temperature Calibrator)

  • 오광석;이왕헌
    • 제어로봇시스템학회논문지
    • /
    • 제22권11호
    • /
    • pp.944-951
    • /
    • 2016
  • Resistance temperature detectors (RTDs) and thermocouple sensors are broadly used to measure temperatures in the engineering and research fields. The contents of this standard calibration procedure (SCP) describe procedures related to the calculation of an electrical temperature calibrator and show different ways to indicate the calibration results, such as measurement uncertainty. As an SCP for the electrical temperature calibrator has not been developed yet, we studied the SCP and found a solution to this problem. In this paper, we present a mathematical model of the data and measurement variations with the calibration data results.

음향 챔버형 마이크로폰 검교정기의 검교정 주파수 한계와 모드 특성을 이용한 개선 방법에 관한 연구 (A study on calibration frequency limit of acoustic chamber type microphone calibrator and improvement method using mode shape)

  • 김차영;신금재;문원규
    • 한국음향학회지
    • /
    • 제41권1호
    • /
    • pp.1-8
    • /
    • 2022
  • 본 논문은 마이크로폰 검교정을 위한 음향 챔버형 검교정기의 고주파 검교정 한계가 나타나는 원인을 밝히고 이를 향상시키는 방법을 제시한다. 상용 유한요소 해석 프로그램을 활용하여 고유 주파수 해석과 주파수 영역 해석을 통해 음향 챔버형 검교정기의 검교정 주파수 한계를 분석하였고, 이를 바탕으로 약 2 Hz 부터 6.4 kHz 까지 1 dB 수준 이내로 정교하게 검교정할 수 있는 음향 챔버형 검교정기를 설계 및 제작하고 실험을 통해 그 성능을 검증하였다. 본 연구를 통해 제안된 음향 챔버형 검교정기는 넓은 주파수 범위에서 다수의 마이크로폰을 동시에 검교정 할 수 있는 이점을 가지고 있어 다수의 마이크로폰을 위한 간편한 검교정에 유용하게 사용될 수 있다.

온도교정기 RTD 저항 및 열전대 직류전압 교정기법 연구 (A Study on the Calibration Technique of RTD and Thermocouple System)

  • 오광석;이왕헌
    • 전기전자학회논문지
    • /
    • 제20권4호
    • /
    • pp.439-448
    • /
    • 2016
  • 온도 측정을 위해 RTD와 열전대 센서가 산업이나 연구 분야에 널리 사용되고 있다. RTD 및 열전대의 온도 교정기에 대한 표준교정절차는 측정에서 포함되는 불확도의 교정 결과를 나타내는 방법을 보여준다. 지금까지 이들에 대한 표준교정절차가 확립되지 않아 다소의 불편함과 표준교정 업무에 어려움이 있었다. 이러한 문제를 해결하기 위해 온도 교정기의 RTD 및 열전대에 대한 교정기법을 연구하게 되었다. 본 논문에서는 이들에 대한 수학적 모델과 교정결과 자료를 제시하였다.