• Title/Summary/Keyword: calibration parameters

Search Result 912, Processing Time 0.028 seconds

Calibration of Hydrologic Parameters of HSPF Using HSPEXP Model Performance Criteria (HSPEXP 모형평가지표를 이용한 HSPF 모형의 수문매개변수 보정)

  • Kim, Sang-Min;Seong, Choung-Hyun;Park, Seung-Woo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.116-119
    • /
    • 2009
  • HSPF is a comprehensive, continuous, lumped parameter, watershed-scale model that simulates the movement of water, sediment, and a wide range of water quality constituents on pervious and impervious surfaces, in soil profiles, and within streams and well-mixed reservoirs. The hydrologic calibration of HSPF is performed manually using the decision-support software Expert System for the Calibration of HSPF (HSPEXP). The initial values for the HSPF hydrologic parameters were estimated based on guidance from BASINS Technical Note 6. Initial parameter values were adjusted for the study watershed during the calibration period within the recommended ranges for the parameters.

  • PDF

Effect of Grinding on Color and Chemical Composition of Pork Sausages by Near Infrared Spectrophotometric Analyses

  • Kang, J.O.;Park, J.Y.;Choy, Y.H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.14 no.6
    • /
    • pp.858-861
    • /
    • 2001
  • Near Infrared spectroscopy was applied to the samples of processed pork to see the effect of grinding on chemical components analyses. Data from conventional chemical analyses of moisture, fat, protein, NaCl were put into calibration model by NIR of reflectance mode. The other properties observed were pH and color parameters ($L^*,\;a^*,\;b^*$). Spectral ranges of 400~2500 nm and 400~1100 nm were compared for color parameters. Spectral ranges of 400~2500 nm and 1100~2500 nm were compared for chemical components and pH. Different spectral ranges caused little changes in the coefficients of determination or standard errors. $R^{2,}s$ of calibration models for color parameters were in the range of 0.97 to 1.00. $R^{2,}s$ of calibration models of intact sausages for moisture, protein, fat, NaCl and pH were 0.98, 0.89, 0.95, 0.73 and 0.77, respectively using spectra at 1100~2500 nm. $R^{2,}s$ of calibration models of ground sausages for moisture, protein, fat, NaCl and pH were 0.97, 0.91, 0.97, 0.42 and 0.56, respectively using spectra at 1100~2500 nm.

A Study of Progressive Parameter Calibrations for Rainfall-Runoff Models (강우-유출모형을 위한 매개변수 순차 보정기법 연구)

  • Kwak, Jae-Won;Kim, Duk-Gil;Hong, Il-Pyo;Kim, Hung-Soo
    • Journal of Wetlands Research
    • /
    • v.11 no.2
    • /
    • pp.107-121
    • /
    • 2009
  • Many rainfall-runoff models have been used for the flood forecasting. However, the determination of rainfall-runoff model parameters is very difficult. In this study, we investigated the efficiency of flood forecasting models by studying the optimization techniques for parameter calibration of SFM, Tank, and SSARR models. We analyzed the correlations between parameters in optimization techniques, then classified the parameters into parameter groups. For this we applied the sequential calibration method through the sensitivity analysis. As the results of the analysis, the parameter groups clibration method showed better result for peak flow and clibtation time.

  • PDF

Active Calibration of the Robot/camera Pose using Cylindrical Objects (원형 물체를 이용한 로봇/카메라 자세의 능동보정)

  • 한만용;김병화;김국헌;이장명
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.5 no.3
    • /
    • pp.314-323
    • /
    • 1999
  • This paper introduces a methodology of active calibration of a camera pose (orientation and position) using the images of cylindrical objects that are going to be manipulated. This active calibration method is different from the passive calibration where a specific pattern needs to be located at a certain position. In the active calibration, a camera attached on the robot captures images of objects that are going to be manipulated. That is, the prespecified position and orientation data of the cylindrical object are transformed into the camera pose through the two consecutive image frames. An ellipse can be extracted from each image frame, which is defined as a circular-feature matrix. Therefore, two circular-feature matrices and motion parameters between the two ellipses are enough for the active calibration process. This active calibration scheme is very effective for the precise control of a mobile/task robot that needs to be calibrated dynamically. To verify the effectiveness of active calibration, fundamental experiments are peformed.

  • PDF

Novel Calibration Method for the Multi-Camera Measurement System

  • Wang, Xinlei
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.6
    • /
    • pp.746-752
    • /
    • 2014
  • In a multi-camera measurement system, the determination of the external parameters is one of the vital tasks, referred to as the calibration of the system. In this paper, a new geometrical calibration method, which is based on the theory of the vanishing line, is proposed. Using a planar target with three equally spaced parallel lines, the normal vector of the target plane can be confirmed easily in every camera coordinate system of the measurement system. By moving the target into more than two different positions, the rotation matrix can be determined from related theory, i.e., the expression of the same vector in different coordinate systems. Moreover, the translation matrix can be derived from the known distance between the adjacent parallel lines. In this paper, the main factors effecting the calibration are analyzed. Simulations show that the proposed method achieves robustness and accuracy. Experimental results show that the calibration can reach 1.25 mm with the range about 0.5m. Furthermore, this calibration method also can be used for auto-calibration of the multi-camera mefasurement system as the feature of parallels exists widely.

Study on the Observability of a Calibration System for a Parallel Tilting Table with Measuerment Operator (측정연산자에 의한 병렬기구 틸팅 테이블의 관측성에 관한 연구)

  • Park Kun Woo;Lee Min Ki;Kim Tae Sung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.6 s.237
    • /
    • pp.795-803
    • /
    • 2005
  • This paper studies the observability of calibration system with a measurement operator. The calibration system needs a simple digital indicator to measure the mobile table movements with respect to the MC coordinate. However, it yields the concern about the poor parameter observability due to measuring only a part of the movements. We uses the QR-decomposition to find the optimal calibration configurations maximizing the linear independence of rows of an observation matrix. The number of identifiable parameter is examined by the rank of the observation matrix, which represents the parameter observability. The method is applied to a 6-axis MC with parallel tilting table and the calibration results are presented. These results verify that all necessary kinematic parameters are observable and the calibration system has robustness to the noise using optimal calibration configurations.

악조건하의 비동일평면 카메라 교정을 위한 알고리즘

  • Ahn, Taek-Jin;Lee, Moon-Kyu
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.7 no.12
    • /
    • pp.1001-1008
    • /
    • 2001
  • This paper presents a new camera calibration algorithm for ill-conditioned cases in which the camera plane is nearly parallel to a set of non-coplanar calibration boards. for the ill-conditioned case, most of existing calibration approaches such as Tsais radial-alignment-constraint method cannot be applied. Recently, for the ill-conditioned coplanar calibration Lee&Lee[16] proposed an iterative algorithm based on the least square method. The non-coplanar calibration algorithm presented in this paper is an iterative two-stage procedure with extends the previous coplanar calibration algorithm. Through the first stage, camera, position and orientation parameters as well as one radial distortion factor are determined optimally for a given data of the scale factor and the focal length. In the second stage, the scale factor and the focal length are locally optimized. This process is repeated until any improvement cannot be expected any more Computational results are provided to show the performance of the algorithm developed.

  • PDF

Development of Runoff and Sediment Auto-calibration Tool for HRSM4BMP Model (HRSM4BMP 모형 유출/유사 자동 보정 툴 개발)

  • Kum, Donghyuk;Ryu, Jichul;Choi, Jaewan;Kang, Hyunwoo;Jang, Chun Hwa;Shin, Dong Suk;Lee, Jae Kwan;Lim, Kyoung Jae
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.1
    • /
    • pp.29-35
    • /
    • 2013
  • Recently, various Best Management Practices (BMPs) have been applied at a field to reduce soil erosion. Hourly Runoff and Sediment Model for Best Management Practices (HRSM4BMP) model could be used to evaluate soil erosion reduction for various agricultural BMPs at fields. Runoff and sediment yield from source areas have to be predicted with greater accuracies to evaluate sediment reduction efficiently with BMPs. To achieve this, the best parameters related with runoff and sediment modules of the HRSM4BMP model should be identified with proper calibration processes. Although manual calibration is often utilized in calibrating runoff and sediment using the HRSM4BMP, objective calibration method would be recommended. The purpose of the study was to develop an automatic calibration tool of the HRSM4BMP model with PARASOL method. This automatic calibration tool was applied to Bangdongri, Chuncheon-si to evaluate its calibration performance. The $R^2$, NSE and RMSE value for runoff estimation were 0.92, 0.92, $0.3m^3$, and for sediment yield estimation were 0.94, 0.94, 0.0027 kg. As shown in this result, automatic calibration tool of HRSM4BMP model would be used to determine the best parameters and can be used to simulate runoff and sediment yield with acceptable accuracies.

Evaluation of Long-term Stability of Interior Orientation Parameters of a Non-metric Camera (비측량용 카메라 내부표정요소의 장기간 안정성 평가)

  • Jeong, Soo
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.29 no.3
    • /
    • pp.283-291
    • /
    • 2011
  • In case of metric cameras, not only fiducial marks but also various parameters related to camera lens are provided to users for the interior orientation process. The parameters have been acquired through precise camera calibration in laboratory by camera maker. But, in case of non-metric cameras, the interior orientation parameters should be determined in person by users through camera calibration with great number of control points. The interior orientation parameters of metric cameras are practically used for long time. But in case of non-metric cameras, the long-term stability of the interior orientation parameters have not been established. Generally, the interior orientation parameters of non-metric cameras are determined in every photogrammetric work. It's been an obstacle to use the non-metric camera in photogrammetric project because so many control points are required to get the interior orientation parameters. In this study, camera calibrations and photogrammetric observations using a non-metric camera have been implemented 25 times periodically for 6 months and the results have been analyzed. As a result, long-them stability of the interior orientation parameters of a non-metric camera is analyzed.

Development of Measurement Assurance Test Procedures between Calibrations (계기 검교정간의 보증시험 절차의 개발)

  • Yum, Bong-Jin;Cho, Jae-Gyeun;Lee, Dong-Wha
    • IE interfaces
    • /
    • v.6 no.1
    • /
    • pp.55-65
    • /
    • 1993
  • A nonstandard instrument used in the filed frequently becomes out-of-calibration due to environmental noise, misuse, aging, etc. A substantial amount of loss may result if such nonstandard instrument is used to check product quality and performance. Traditional periodic calibration at the calibration center is not capable of detecting out-of-calibration status while the instrument is in use, and therefore, statistical methods need to be developed to check the status of a nonstandard instrument in the field between calibrations. Developed in this paper is a unified measurement assurance model in which statistical calibration at the calibration center and measurement assurance test in the filed are combined. We developed statistical procedures to detect changes in precision and in the coefficients of the calibration equation. Futher, computational experiments are conducted to evaluate how the power of test varies with respect to the parameters involved. Based upon the computational results we suggest procedures for designing effective measurement assurance tests.

  • PDF