• Title/Summary/Keyword: calibration of transducer

Search Result 67, Processing Time 0.027 seconds

Respiratory air flow transducer calibration technique for forced vital capacity test (노력성 폐활량검사시 호흡기류센서의 보정기법)

  • Cha, Eun-Jong;Lee, In-Kwang;Jang, Jong-Chan;Kim, Seong-Sik;Lee, Su-Ok;Jung, Jae-Kwan;Park, Kyung-Soon;Kim, Kyung-Ah
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.5
    • /
    • pp.1082-1090
    • /
    • 2009
  • Peak expiratory flow rate(PEF) is a very important diagnostic parameter obtained from the forced vital capacity(FVC) test. The expiratory flow rate increases during the short initial time period and may cause measurement error in PEF particularly due to non-ideal dynamic characteristic of the transducer. The present study evaluated the initial rise slope($S_r$) on the flow rate signal to compensate the transducer output data. The 26 standard signals recommended by the American Thoracic Society(ATS) were generated and flown through the velocity-type respiratory air flow transducer with simultaneously acquiring the transducer output signal. Most PEF and the corresponding output($N_{PEF}$) were well fitted into a quadratic equation with a high enough correlation coefficient of 0.9997. But only two(ATS#2 and 26) signals resulted significant deviation of $N_{PEF}$ with relative errors>10%. The relationship between the relative error in $N_{PEF}$ and $S_r$ was found to be linear, based on which $N_{PEF}$ data were compensated. As a result, the 99% confidence interval of PEF error was turned out to be approximately 2.5%, which was less than a quarter of the upper limit of 10% recommended by ATS. Therefore, the present compensation technique was proved to be very accurate, complying the international standards of ATS, which would be useful to calibrate respiratory air flow transducers.

The Determination of Temperature and Humidity Sensitivity Coefficients of Torque Transducers using Seasonal Climatic Changes of Ambient Conditions in the Laboratory (계절에 따른 실험실 환경변화를 이용한 토크측정기의 온도 및 습도 감도계수 결정)

  • Derebew, Mulugeta;Kim, Min Seok;Park, Yon Kyu;Lee, Ho Young
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.32 no.2
    • /
    • pp.185-190
    • /
    • 2015
  • This paper presents a new method to determine sensitivity coefficients of temperature and humidity of torque transducers by using a natural and seasonal variation of ambient conditions at the laboratory. We had measured the sensitivities of the torque transducers over almost one year using the KRISS 2 kN m torque standard machine. The sensitivity data acquired at various ambient conditions were processed using our measurement model to extract the sensitivity coefficients of temperature and humidity simultaneously with high precision. A comparison with a previous method using an environmental control chamber was carried out to test the feasibility of using our new method. Two results agreed within the uncertainty. We revealed that the torque measuring errors could be 8 times higher than the measurement and calibration capability of KRISS torque standard machine if the sensitivity changes due to the temperature and humidity are not properly corrected during a calibration.

Development of a Real-time 3D Intraoral Scanner Based on Fringe-Projection Technique (프린지 투영법을 이용한 실시간 3D 구강 내 스캐너의 개발)

  • Ullah, Furqan;Lee, Gunn-Soo;Park, Kang
    • Korean Journal of Computational Design and Engineering
    • /
    • v.17 no.3
    • /
    • pp.156-163
    • /
    • 2012
  • Real-time three-dimensional shape measurement is becoming increasingly important in various fields, including medical sciences, high-technology industry, and microscale measurements. However, there are not so many 3D profile tools specially designed for specifically narrow space, for example, to scan the tooth shape of a human jaw. In this paper, a real-time 3D intraoral scanner is proposed for the measurement of tooth profile in the mouth cavity. The proposed system comprises a laser diode beam, a micro charge-coupled device, a graticule, a piezoelectric transducer, a set of optical lenses, and a polhemus device sensor. The phase-shifting technique is used along with an accurate calibration method for the measurement of the tooth profile. Experimental and theoretical inspection of the phase-to-coordinate relation is presented. In addition, a nonlinear system model is developed for collimating illumination that gives the more accurate mathematical representation of the system, thus improves the shape measurement accuracy. Experiment results are presented to verify the feasibility and performance of the developed system. The experimental results indicate that overall measurement error accuracy can be controlled within 0.4 mm with a variability of ${\pm}0.01$.

Calibration of Hydrographic Survey Multibeam System Using Terrestrial Laser Scanning and TS Surveying (지상 레이저 스캐닝과 TS 측량을 이용한 멀티빔 시스템의 검·보정)

  • Kim, Jin Soo
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.31 no.3
    • /
    • pp.199-207
    • /
    • 2013
  • In hydrographic survey, data surveyed with multibeam system includes various errors due to multiple factors. These are corrected by a calibration called patch test, and if existing method is used, the test needs to be conducted for about 8 times for precise system calibration. For more prompt and precise multibeam system calibration, the exact offset of a ship was determined using terrestrial laser scanning and TS surveying, which was used as the initial input for the patch test. In the result, the error of closure was 0.001 m or less for TS surveying and backsight error was 0.005 m or less for scanning. All the surveying data based on the same local coordinate was converted into vessel reference coordinate during which R-square for all rotation angles was 0.99 or higher and standard deviation was 0.008 m or less. Finally, in a patch test using calculated offset of sensors and motion sensor offset, the offset of MBES transducer satisfied manual on hydrography only with 1-time calibration. With these results, it is thought that terrestrial laser scanning and TS surveying can fully be utilized for multibeam system calibration.

원통형 커패시턴스 센서를 이용한 초정밀 공기 주축의 회전오차 측정

  • 김해일;박상신;한동철
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.04a
    • /
    • pp.637-642
    • /
    • 1995
  • For measuring the error motion of ultra-precision spindle, eliminating the geometric errors is a must. Unless it is achieved, geometric errors will be dominant in data. Here, the roundness error and alignment error between spindle and sensor are to be removed. That's because typical error range of such spindle is muchless than geometric one. A capacitive transducer of cylidricalshape was developed, which takes full advantage of the spatial-averaging effect by using large area compared tpo the geometric error. This idea was first proposed by Chapman and here it is modified for better performance with nomical gap of 50 .mu. m and with newly designed guards which encompass the respective sensor to rectify the electrical field distribution in good shape. The measurement system is made to get the orbit of Ultra-Precision Air Spindle which is supposed to have its runout under 1 .mu. m. The Calibration data of this sensor is presented and the spindle orbit from 2000rpm to 5500rpm is showed. It is quite reasonable to use this sensor in the range of 60 .mu. m with an accuracy of several tens of nm.

Development of Dynamic Pressure Calibrator with Positive Step Pressure (정방향 스텝 동압력 교정장치 개발)

  • 최주호;홍성수;우삼용;이경희;김창복
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.4 no.1
    • /
    • pp.155-169
    • /
    • 2001
  • In this paper, dynamic pressure is mainly generated in the closed chamber of gun when the propellant is fired and has exponential pressure motion. Dynamic pressure calibrator with positive step pressure was designed and manufactured to meet the calibration of piezoelectric high pressure transducers which are mainly used to measure dynamic pressure motion in the test of weapon systems. In addition, the results of Performance test and analysis of system uncertainty are provided.

  • PDF

Applications of Strain Gages to Farm Machine Elements (농업기계 요소의 스트레인 게이지 응용에 관한 연구)

  • 류관희;정창주;고학균;최재갑;유수남
    • Journal of Biosystems Engineering
    • /
    • v.5 no.2
    • /
    • pp.40-57
    • /
    • 1980
  • The aim of this study was to promote extensive use of strain gage for accurate measurement in the area of farm machinery research. The results are summarized as follows. 1. Although many strain gate transducers commercially available such as load-cells , accelerometers and pressure transducers have been used in the area of farm machinery research, many types of transducers had to be developed due to the inadaptability or high cost commercial transducers, in many instances. 2. A strain -gaged cantilever beam could be used as a good educational material to demonstrate the methods of Wheatstone bridge arrangement, calibration and theoreticval computation. A ring type load-cell and shaft torque transducer also could be used for the same purpose. 3. The torque and angular speed transducers for an auto-feed thresher and the displacement and pressure transducers for a rice whitener were made and gave satisfactory results. 4. Based on the above results, it is possible to develop simple and low-cost transducers to measure displacement, angular speed , torque and pressure of farm machine elements.

  • PDF

Study on the Development of Multi-Path Ultrasonic Gas Flowmeter (전달 시간차 방식 다회선 초음파 가스 유량계 개발)

  • 황원호;박상국;이치환;장경영
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1046-1050
    • /
    • 2003
  • In this paper, we describe study on the development or multi-path ultrasonic gas flowmeter using a transit time method. This system includes 5 pairs of ultrasonic transducers. ultrasonic signal processing unit using switch matrix method, computation algorithm of gas flow rate, spool piece type multi-path pipe unit. We have developed enhanced type of main ultrasonic signal processing unit using switch matrix method fer multi-path ultrasonic gas flowmeter. Also, we have developed the new transmitting & receiving method of ultrasonic waves and the new signal processing algorithm for the computation of ultrasonic transit time from received ultrasonic waves. In this study, we have designed more compact signal processing unit compared with the conventional hardware system of multi-path ultrasonic gas flowmeter. We have confirmed its reliability for multi-path ultrasonic gas flowmeter through the laboratory test using calibration system. In the future. we will perform the field test for the developed system in the POSCO gas line.

  • PDF

A Study on Development of Signal Conditioner for Test of Automatic Control Equipments in Hydro Power Plant (수력발전소 자동제어설비 시험용 신호변환장치 개발에 관한 연구)

  • Byun, Doo-Gyoon;Chang, Moon-Soung;Kim, Ju-Hyeon
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.169-171
    • /
    • 1995
  • Automatic control equipment in hydro power plant, such as turbine governor or automatic voltage regulator have to act promptly against for variation of power system, so it is necessary to check and test continuously. During last five years, the performance test of automatic control equipment was performed about 20 units of hydro turbine generator. In this process, because it has complex connection and before calibration, signal conditioner was developed as an auxiliary equipment for performance test. It includes function of signal amplifier, transducer, and meters. As a result of use this equipment for electric governor test at soyang-gang hydro power plant, it was possible to find output data equal to old one.

  • PDF

A Study on the Measurement System for Alignment of Cylindrical Forging Die (원통형 단조금형의 정렬을 위한 측정시스템에 관한 연구)

  • Youn, Jae-Woong
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.18 no.1
    • /
    • pp.83-89
    • /
    • 2009
  • In most multi-stage forging processes, the die spotting process or alignment of punch and die depends on the manual operation. It results a very tedious and inefficient procedure, thus the proper measurement system is needed to improve productivity and accuracy. This paper proposes a measurement system for alignment of die and punch which has a cylindrical holder, and describes the system concepts using 3 eddy-current displacement transducers and precise measurement jig. In order to apply this measurement system to real situations, the measuring procedures and system calibration method, etc. are proposed. Finally, the accuracy and productivity of this measurement system are investigated in this paper.